DP8570A DP8570A Timer Clock Peripheral (TCP) Literature Number: SNAS557 DP8570A Timer Clock Peripheral (TCP) General Description The DP8570A is intended for use in microprocessor based systems where information is required for multi-tasking, data logging or general time of day/date information. This device is implemented in low voltage silicon gate microCMOS technology to provide low standby power in battery back-up environments. The circuit's architecture is such that it looks like a contiguous block of memory or I/O ports. The address space is organized as 2 software selectable pages of 32 bytes. This includes the Control Registers, the Clock Counters, the Alarm Compare RAM, the Timers and their data RAM, and the Time Save RAM. Any of the RAM locations that are not being used for their intended purpose may be used as general purpose CMOS RAM. Time and date are maintained from 1/100 of a second to year and leap year in a BCD format, 12 or 24 hour modes. Day of week, day of month and day of year counters are provided. Time is controlled by an on-chip crystal oscillator requiring only the addition of the crystal and two capacitors. The choice of crystal frequency is program selectable. Two independent multifunction 10 MHz 16-bit timers are provided. These timers operate in four modes. Each has its own prescaler and can select any of 8 possible clock inputs. Thus, by programming the input clocks and the timer counter values a very wide range of timing durations can be achieved. The range is from about 400 ns (4.915 MHz oscillator) to 65,535 seconds (18 hrs., 12 min.). Power failure logic and control functions have been integrated on chip. This logic is used by the TCP to issue a power fail interrupt, and lock out the mp interface. The time power fails may be logged into RAM automatically when VBB l VCC. Additionally, two supply pins are provided. When VBB l VCC, internal circuitry will automatically switch from the main supply to the battery supply. Status bits are provided to indicate initial application of battery power, system power, and low battery detect. (Continued) Features Y Y Y Y Y Y Full function real time clock/calendar 12/24 hour mode timekeeping Day of week and day of years counters Four selectable oscillator frequencies Parallel Resonant Oscillator Two 16-bit timers 10 MHz external clock frequency Programmable multi-function output Flexible re-trigger facilities Power fail features Internal power supply switch to external battery Power Supply Bus glitch protection Automatic log of time into RAM at power failure On-chip interrupt structure Periodic, alarm, timer and power fail interrupts Up to 44 bytes of CMOS RAM INTR/MFO/T1 pins programmable High/Low and pushpull or open drain Block Diagram TL/F/8638 - 1 FIGURE 1 TRI-STATEE is a registered trademark of National Semiconductor Corporation. C1995 National Semiconductor Corporation TL/F/8638 RRD-B30M75/Printed in U. S. A. DP8570A Timer Clock Peripheral (TCP) May 1993 Absolute Maximum Ratings (Notes 1 & 2) Operation Conditions If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/Distributors for availability and specifications. Supply Voltage (VCC) (Note 3) Min 4.5 2.2 Max Unit 5.5 V VCCb0.4 V Supply Voltage (VBB) (Note 3) DC Input or Output Voltage V 0.0 VCC (VIN, VOUT) b 40 a 85 Operation Temperature (TA) C Electr-Static Discharge Rating TBD 1 kV Transistor Count 15,200 Typical Values iJA DIP Board e 45 C/W Socket e 50 C/W iJA PLCC Board e 77 C/W Socket e 85 C/W b 0.5V to a 7.0V Supply Voltage (VCC) b 0.5V to VCC a 0.5V DC Input Voltage (VIN) b 0.5V to VCC a 0.5V DC Output Voltage (VOUT) b 65 C to a 150 C Storage Temperature Range Power Dissipation (PD) 500 mW Lead Temperature (Soldering, 10 sec.) 260 C DC Electrical Characteristics VCC e 5V g 10%, VBB e 3V, VPFAIL l VIH, CL e 100 pF (unless otherwise specified) Symbol Parameter Conditions Min VIH High Level Input Voltage Any Inputs Except OSC IN, 2.0 (Note 4) OSC IN with External Clock VBB b0.1 VIL Low Level Input Voltage All Inputs Except OSC IN OSC IN with External Clock VOH High Level Output Voltage (Excluding OSC OUT) VOL Low Level Output Voltage (Excluding OSC OUT) IIN IOZ ILKG Input Current (Except OSC IN) Output TRI-STATEE Current Output High Leakage Current T1, MFO, INTR Pins Quiescent Supply Current (Note 7) IOUT e b20 mA IOUT e b4.0 mA IOUT e 20 mA IOUT e 4.0 mA VIN e VCC or GND VOUT e VCC or GND VOUT e VCC or GND Outputs Open Drain FOSC e 32.768 kHz VIN e VCC or GND (Note 5) VIN e VCC or GND (Note 6) VIN e VIH or VIL (Note 6) FOSC e 4.194304 MHz or 4.9152 MHz VIN e VCC or GND (Note 6) VIN e VIH or VIL (Note 6) VBB e GND VIN e VCC or GND FOSC e 32.768 kHz FOSC e 4.9152 MHz or 4.194304 MHz ICC ICC IBB IBLK Quiescent Supply Current (Single Supply Mode) (Note 7) Standby Mode Battery Supply Current (Note 8) Battery Supply Leakage Max 0.8 0.1 Units V V V V 0.1 0.25 g 1.0 g 5.0 V V V V mA mA g 5.0 mA 260 1.0 12.0 mA mA mA 8 20 mA mA 80 7.5 mA mA 10 400 mA mA 1.5 mA mA VCC b0.1 3.5 VCC e GND OSC OUT e Open Circuit, Other Pins e GND FOSC e 32.768 kHz FOSC e 4.9152 MHz or 4.194304 MHz 2.2V s VBB s 4.0V Other Pins at GND VCC e GND, VBB e 4.0V VCC e 5.5V, VBB e 2.2V b5 Note 1: Absolute Maximum Ratings are those values beyond which damage to the device may occur. Note 2: Unless otherwise specified all voltages are referenced to ground. Note 3: For FOSC e 4.194304 or 4.9152 MHz, VBB minimum e 2.8V. In battery backed mode, VBB s VCC b 0.4V. Single Supply Mode: Data retention voltage is 2.2V min. In single Supply Mode (Power connected to VCC pin) 4.5V s VCC s 5.5V. Note 4: This parameter (VIH) is not tested on all pins at the same time. Note 5: This specification tests ICC with all power fail circuitry disabled, by setting D7 of Interrupt Control Register 1 to 0. Note 6: This specification tests ICC with all power fail circuitry enabled, by setting D7 of Interrupt Control Register 1 to 1. Note 7: This specification is tested with both the timers and OSC IN driven by a signal generator. Contents of the Test Register e 00(H), the MFO pin is not configured as buffered oscillator out and MFO, T1, INTR, are configured as open drain. Note 8: This specification is tested with both the timers off, and only OSC IN is driven by a signal generator. Contents of the Test Register e 00(H) and the MFO pin is not configured as buffered oscillator out. 2 AC Electrical Characteristics VCC e 5V g 10%, VBB e 3V, VPFAIL l VIH, CL e 100 pF (unless otherwise specified) Symbol Parameter Min Max Units READ TIMING tAR Address Valid Prior to Read Strobe 20 ns tRW Read Strobe Width (Note 9) 80 ns tCD Chip Select to Data Valid Time tRAH Address Hold after Read (Note 10) tRD Read Strobe to Valid Data tDZ Read or Chip Select to TRI-STATE tRCH Chip Select Hold after Read Strobe 0 ns tDS Minimum Inactive Time between Read or Write Accesses 50 ns tAW Address Valid before Write Strobe 20 ns tWAH Address Hold after Write Strobe (Note 10) 3 ns tCW Chip Select to End of Write Strobe 90 ns tWW Write Strobe Width (Note 11) 80 ns tDW Data Valid to End of Write Strobe 50 ns tWDH Data Hold after Write Strobe (Note 10) 3 ns tWCH Chip Select Hold after Write Strobe 0 ns 80 ns 70 ns 60 ns 3 ns WRITE TIMING TIMER 0/TIMER 1 TIMING FTCK Input Frequency Range 10 MHz tCK Propagation Delay Clock to Output DC 120 ns tGO Propagation Delay G0 to G1 to Timer Output (Note 12) O 100 ns tPGW Pulse Width G0 or G1 E (Note 12) 25 ns tGS Setup Time, G0, G1 to TCK (Note 13) 100 ns INTERRUPT TIMING tROLL Clock Rollover to INTR Out is Typically 16.5 ms Note 9: Read Strobe width as used in the read timing table is defined as the period when both chip select and read inputs are low. Hence read commences when both signals are low and terminates when either signal returns high. Note 10: Hold time is guaranteed by design but not production tested. This limit is not used to calculate outgoing quality levels. Note 11: Write Strobe width as used in the write timing table is defined as the period when both chip select and write inputs are low. Hence write commences when both signals are low and terminates when either signal returns high. Note 12: Timers in Mode 3. Note 13: Guaranteed by design, not production tested. This limit is not used to calculate outgoing quality levels. AC Test Conditions Input Pulse Levels Input Rise and Fall Times Input and Output Reference Levels TRI-STATE Reference Levels (Note 15) GND to 3.0V 6 ns (10%-90%) 1.3V Active High a 0.5V Active Low b0.5V Note 14: CL e 100 pF, includes jig and scope capacitance. Note 15: S1 e VCC for active low to high impedance measurements. S1 e GND for active high to high impedance measurements. S1 e open for all other timing measurements. Capacitance (TA e 25 C, f e 1 MHz) Symbol Parameter (Note 16) Typ Units CIN Input Capacitance 5 pF COUT Output Capacitance 7 pF TL/F/8638 - 23 Note 16: This parameter is not 100% tested. Note 17: Output rise and fall times 25 ns max (10%-90%) with 100 pF load. 3 Timing Waveforms Read Timing Diagram TL/F/8638 - 24 Write Timing Diagram TL/F/8638 - 25 4 used then this pin must be tied to ground, the TCP programmed for single power supply only, and power applied to the VCC pin. General Description (Continued) The DP8570A's interrupt structure provides four basic types of interrupts: Periodic, Alarm/Compare, Timer, and Power Fail. Interrupt mask and status registers enable the masking and easy determination of each interrupt. One dedicated general purpose interrupt output is provided. A second interrupt output is available on the Multiple Function Output (MFO) pin. Each of these may be selected to generate an interrupt from any source. Additionally, the MFO pin may be programmed to be either as oscillator output or Timer 0's output. TCK, G1, G0, (Inputs), T1 (Output): TCK is the clock input to both timers when they have an external clock selected. In modes 0, 1, and 2, G0 and G1 are active low enable inputs for timers 0 and 1 respectively. In mode 3, G0 and G1 are positive edge triggers to the timers. T1 is dedicated to the timer 1 output. The T1 output can be programmed active high or low, push-pull or open drain. Timer 0 output is available through MFO pin if desired. If in battery backed mode and a pull-up resistor is attached to T1, it should be connected to a voltage no greater than VBB. The T1 pin is configured open drain during battery operation (VBB l VCC). VCC: This is the main system power pin. Pin Description CS, RD, WR (Inputs): These pins interface to mP control lines. The CS pin is an active low enable for the read and write operations. Read and Write pins are also active low and enable reading or writing to the TCP. All three pins are disabled when power failure is detected. However, if a read or write is in progress at this time, it will be allowed to complete its cycle. A0 - A4 (Inputs): These 5 pins are for register selection. They individually control which location is to be accessed. These inputs are disabled when power failure is detected. OSC IN (Input): OSC OUT (Output): These two pins are used to connect the crystal to the internal parallel resonant oscillator. The oscillator is always running when power is applied to VBB and VCC, and the correct crystal select bits in the Real Time Mode Register have been set. MFO (Output): The multi-function output can be used as a second interrupt output for interrupting the mP. This pin can also provide an output for the oscillator or the internal Timer 0. The MFO output can be programmed active high or low, open drain or push-pull. If in battery backed mode and a pull-up resistor is attached, it should be connected to a voltage no greater than VBB. This pin is configured open drain during battery operation (VBB l VCC). INTR (Output): The interrupt output is used to interrupt the processor when a timing event or power fail has occurred and the respective interrupt has been enabled. The INTR output can be programmed active high or low, push-pull or open drain. If in battery backed mode and a pull-up resistor is attached, it should be connected to a voltage no greater than VBB. This pin is configured open drain during battery operation (VBB l VCC). The output is a DC voltage level. To clear the INTR, write a 1 to the appropriate bit(s) in the Main Status Register. D0 - D7 (Input/Output): These 8 bidirectional pins connect to the host mP's data bus and are used to read from and write to the TCP. When the PFAIL pin goes low and a write is not in progress, these pins are at TRI-STATE. PFAIL (Input): In battery backed mode, this pin can have a digital signal applied to it via some external power detection logic. When PFAIL e logic 0 the TCP goes into a lockout mode, in a minimum of 30 ms or a maximum of 63 ms unless lockout delay is programmed. In the single power supply mode, this pin is not useable as an input and should be tied to VCC. Refer to section on Power Fail Functional Description. VBB (Battery Power Pin): This pin is connected to a backup power supply. This power supply is switched to the internal circuitry when the VCC becomes lower than VBB. Utilizing this pin eliminates the need for external logic to switch in and out the back-up power supply. If this feature is not to be GND: This is the common ground power pin for both VBB and VCC. Connection Diagrams Dual-In-Line TL/F/8638 - 5 Top View Order Number DP8570AN See NS Package Number N28B Plastic Chip Carrier TL/F/8638 - 6 Top View Order Number DP8570AV See NS Package Number V28A 5 Functional Description The DP8570A contains a fast access real time clock, two 10 MHz 16-bit timers, interrupt control logic, power fail detect logic, and CMOS RAM. All functions of the TCP are controlled by a set of nine registers. A simplified block diagram that shows the major functional blocks is given in Figure 1 . The blocks are described in the following sections: 1. Real Time Clock 2. Oscillator Prescaler 3. Interrupt Logic 4. Power Failure Logic 5. Additional Supply Management 6. Timers The memory map of the TCP is shown in the memory addressing table. The memory map consists of two 31 byte pages with a main status register that is common to both pages. A control bit in the Main Status Register is used to select either page. Figure 2 shows the basic concept. Page 0 contains all the clock timer functions, while page 1 has scratch pad RAM. The control registers are split into two separate blocks to allow page 1 to be used entirely as scratch pad RAM. Again a control bit in the Main Status Register is used to select either control register block. TL/F/8638 - 4 FIGURE 2. DP8570A Internal Memory Map 6 Functional Description (Continued) INITIAL POWER-ON of BOTH VBB and VCC VBB and VCC may be applied in any sequence. In order for the power fail circuitry to function correctly, whenever power is off, the VCC pin must see a path to ground through a maximum of 1 MX. The user should be aware that the control registers will contain random data. The first task to be carried out in an initialization routine is to start the oscillator by writing to the crystal select bits in the Real Time Mode Register. If the DP8570A is configured for single supply mode, an extra 50 mA may be consumed until the crystal select bits are programmed. The user should also ensure that the TCP is not in test mode (see register descriptions). Save Enable bit (D7) of the Interrupt Routing Register, and then to write a zero. Writing a one into this bit will enable the clock contents to be duplicated in the Time Save RAM. Changing the bit from a one to a zero will freeze and store the contents of the clock in Time Save RAM. The time then can be read without concern for clock rollover, since internal logic takes care of synchronization of the clock. Because only the bits used by the clock counters will be latched, the Time Save RAM should be cleared prior to use to ensure that random data stored in the unused bits do not confuse the host microprocessor. This bit can also provide time save at power failure, see the Additional Supply Management Functions section. With the Time Save Enable bit at a logical 0, the Time Save RAM may be used as RAM if the latched read function is not necessary. REAL TIME CLOCK FUNCTIONAL DESCRIPTION As shown in Figure 2 , the clock has 10 bytes of counters, which count from 1/100 of a second to years. Each counter counts in BCD and is synchronously clocked. The count sequence of the individual byte counters within the clock is shown later in Table VII. Note that the day of week, day of month, day of year, and month counters all roll over to 1. The hours counter in 12 hour mode rolls over to 1 and the AM/PM bit toggles when the hours rolls over to 12 (AM e 0, PM e 1). The AM/PM bit is bit D7 in the hours counter. All other counters roll over to 0. Also note that the day of year counter is 12 bits long and occupies two addresses. Upon initial application of power the counters will contain random information. INITIALIZING AND WRITING TO THE CALENDAR-CLOCK Upon initial application of power to the TCP or when making time corrections, the time must be written into the clock. To correctly write the time to the counters, the clock would normally be stopped by writing the Start/Stop bit in the Real Time Mode Register to a zero. This stops the clock from counting and disables the carry circuitry. When initializing the clock's Real Time Mode Register, it is recommended that first the various mode bits be written while maintaining the Start/Stop bit reset, and then writing to the register a second time with the Start/Stop bit set. The above method is useful when the entire clock is being corrected. If one location is being updated the clock need not be stopped since this will reset the prescaler, and time will be lost. An ideal example of this is correcting the hours for daylight savings time. To write to the clock ``on the fly'' the best method is to wait for the 1/100 of a second periodic interrupt. Then wait an additional 16 ms, and then write the data to the clock. READING THE CLOCK: VALIDATED READ Since clocking of the counter occurs asynchronously to reading of the counter, it is possible to read the counter while it is being incremented (rollover). This may result in an incorrect time reading. Thus to ensure a correct reading of the entire contents of the clock (or that part of interest), it must be read without a clock rollover occurring. In general this can be done by checking a rollover bit. On this chip the periodic interrupt status bits can serve this function. The following program steps can be used to accomplish this. 1. Initialize program for reading clock. 2. Dummy read of periodic status bit to clear it. 3. Read counter bytes and store. 4. Read rollover bit, and test it. 5. If rollover occured go to 3. 6. If no rollover, done. To detect the rollover, individual periodic status bits can be polled. The periodic bit chosen should be equal to the highest frequency counter register to be read. That is if only SECONDS through HOURS counters are read, then the SECONDS periodic bit should be used. PRESCALER/OSCILLATOR FUNCTIONAL DESCRIPTION Feeding the counter chain is a programmable prescaler which divides the crystal oscillator frequency to 32 kHz and further to 100 Hz for the counter chain (see Figure 3 ). The crystal frequency that can be selected are: 32 kHz, 32.768 kHz, 4.9152 MHz, and 4.194304 MHz. Once 32 kHz is generated it feeds both timers and the clock. The clock and timer prescalers can be independently enabled by controlling the timer or clock Start/Stop bits. READING THE CLOCK: INTERRUPT DRIVEN Enabling the periodic interrupt mask bits cause interrupts just as the clock rolls over. Enabling the desired update rate and providing an interrupt service routine that executes in less than 10 ms enables clock reading without checking for a rollover. READING THE CLOCK: LATCHED READ Another method to read the clock that does not require checking the rollover bit is to write a one into the Time TL/F/8638 - 2 FIGURE 3. Programmable Clock Prescaler Block 7 Functional Description (Continued) The interrupts are enabled by writing a one to the appropriate bits in Interrupt Control Register 0 and/or 1. Any of the interrupts can be routed to either the INTR pin or the MFO pin, depending on how the Interrupt Routing register is programmed. This, for example, enables the user to dedicate the MFO as a non-maskable interrupt pin to the CPU for power failure detection and enable all other interrupts to appear on the INTR pin. The polarity for the active interrupt can be programmed in the Output Mode Register for either active high or low, and open drain or push pull outputs. The oscillator is programmed via the Real Time Mode Register to operate at various frequencies. The crystal oscillator is designed to offer optimum performance at each frequency. Thus, at 32.768 kHz the oscillator is configured as a low frequency and low power oscillator. At the higher frequencies the oscillator inverter is reconfigured. In addition to the inverter, the oscillator feedback bias resistor is included on chip, as shown in Figure 4 . The oscillator input may be driven from an external source if desired. Refer to test mode application note for details. The oscillator stability is enhanced through the use of an on chip regulated power supply. The typical range of trimmer capacitor (as shown in Oscillator Circuit Diagram Figure 4 , and in the typical application) at the oscillator input pin is suggested only to allow accurate tuning of the oscillator. This range is based on a typical printed circuit board layout and may have to be changed depending on the parasitic capacitance of the printed circuit board or fixture being used. In all cases, the load capacitance specified by the crystal manufacturer (nominal value 11 pF for the 32.768 crystal) is what determines proper oscillation. This load capcitance is the series combination of capacitance on each side of the crystal (with respect to ground). TABLE I. Registers that are Applicable to Interrupt Control Register Name Main Status Register Periodic Flag Register Interrupt Routing Register Interrupt Control Register 0 Interrupt Control Register 1 Output Mode Register TL/F/8638-3 Co Ct Page Select Address X 0 X 0 00H 03H 0 0 04H 1 0 03H 1 0 04H 1 0 02H The Interrupt Status Flag D0, in the Main Status Register, indicates the state of INTR and MFO outputs. It is set when either output becomes active and is cleared when all TCP interrupts have been cleared and no further interrupts are pending (i.e., both INTR and MFO are returned to their inactive state). This flag enables the TCP to be rapidly polled by the mP to determine the source of an interrupt in a wired OR interrupt system. Note that the Interrupt Status Flag will only monitor the state of the MFO output if it has been configured as an interrupt output (see Output Mode Register description). This is true, regardless of the state of the Interrupt Routing Register. Thus the Interrupt Status Flag provides a true reflection of all conditions routed to the external pins. Status for the interrupts are provided by the Main Status Register and the Periodic Flag Register. Bits D1 - D5 of the Main Status Register are the main interrupt bits. These register bits will be set when their associated timing events occur. Enabled Alarm or Timer interrupts that occur will set its Main Status Register bit to a one. However, an external interrupt will only be generated if the appropriate Alarm or Timer interrupt enable bits are set (see Figure 5 ). Disabling the periodic bits will mask the Main Status Register periodic bit, but not the Periodic Flag Register bits. The Power Fail Interrupt bit is set when the interrupt is enabled and a power fail event has occurred, and is not reset until the power is restored. If all interrupt enable bits are 0 no interrupt will be asserted. However, status still can be read from the Main Status Register in a polled fashion (see Figure 5 ). To clear a flag in bits D2 - D5 of the Main Status Register a 1 must be written back into the bit location that is to be cleared. For the Periodic Flag Register reading the status will reset all the periodic flags. FIGURE 4. Oscillator Circuit Diagram XTAL Register Select ROUT (Switched Internally) 32/32.768 kHz 47 pF 2 pF-22 pF 150 kX to 350 kX 4.194304 MHz 68 pF 0 pF-80 pF 500X to 900X 4.9152 MHz 68 pF 29 pF-49 pF 500X to 900X INTERRUPT LOGIC FUNCTIONAL DESCRIPTION The TCP has the ability to coordinate processor timing activities. To enhance this, an interrupt structure has been implemented which enables several types of events to cause interrupts. Interrupts are controlled via two Control Registers in block 1 and two Status Registers in block 0. (See Register Description for notes on paging and also Figure 5 and Table I.) 8 Functional Description (Continued) To generate periodic interrupts at the desired rate, the associated Periodic Interrupt Enable bit in Interrupt Control Register 0 must be set. Any combination of periodic interrupts may be enabled to operate simultaneously. Enabled periodic interrupts will now affect the Periodic Interrupt Flag in the Main Status Register. The Periodic Route bit in the Interrupt Routing Register is used to route the periodic interrupt events to either the INTR output or the MFO output. When a periodic event occurs, the Periodic Interrupt Flag in the Main Status Register is set, causing an interrupt to be generated. The mP clears both flag and interrupt by writing a ``1'' to the Periodic Interrupt Flag. The individual flags in the periodic Interrupt Flag Register do not require clearing to cancel the interrupt. If all periodic interrupts are disabled and a periodic interrupt is left pending (i.e., the Periodic Interrupt Flag is still set), the Periodic Interrupt Flag will still be required to be cleared to cancel the pending interrupt. Interrupts Fall Into Four Categories: 1. The Timer Interrupts: For description see Timer Section. 2. The Alarm Compare Interrupt: Issued when the value in the time compared RAM equals the counter. 3. The Periodic Interrupts: These are issued at every increment of the specific clock counter signal. Thus, an interrupt is issued every minute, second, etc. Each of these interrupts occurs at the roll-over of the specific counter. 4. The Power Fail Interrupt: Issued upon recognition of a power fail condition by the internal sensing logic. The power failed condition is determined by the signal on the PFAIL pin. The internal power fail signal is gated with the chip select signal to ensure that the power fail interrupt does not lock the chip out during a read or write. ALARM COMPARE INTERRUPT DESCRIPTON The alarm/time comparison interrupt is a special interrupt similar to an alarm clock wake up buzzer. This interrupt is generated when the clock time is equal to a value programmed into the alarm compare registers. Up to six bytes can be enabled to perform alarm time comparisons on the counter chain. These six bytes, or some subset thereof, would be loaded with the future time at which the interrupt will occur. Next, the appropriate bits in the Interrupt Control Register 1 are enabled or disabled (refer to detailed description of Interrupt Control Register 1). The TCP then compares these bytes with the clock time. When all the enabled compare registers equal the clock time an alarm interrupt is issued, but only if the alarm compare interrupt is enabled can the interrupt be generated externally. Each alarm compare bit in the Control Register will enable a specific byte for comparison to the clock. Disabling a compare byte is the same as setting its associated counter comparator to an ``always equal'' state. For example, to generate an interrupt at 3:15 AM of every day, load the hours compare with 0 3 (BCD), the minutes compare with 1 5 (BCD) and the faster counters with 0 0 (BCD), and then disable all other compare registers. So every day when the time rolls over from 3:14:59.99, an interrupt is issued. This bit may be reset by writing a one to bit D3 in the Main Status Register at any time after the alarm has been generated. If time comparison for an individual byte counter is disabled, that corresponding RAM location can then be used as general purpose storage. POWER FAIL INTERRUPTS DESCRIPTION The Power Fail Status Flag in the Main Status Register monitors the state of the internal power fail signal. This flag may be interrogated by the mP, but it cannot be cleared; it is cleared automatically by the TCP when system power is restored. To generate an interrupt when the power fails, the Power Fail Interrupt Enable bit in Interrupt Control Register 1 is set. The Power Fail Route bit determines which output the interrupt will appear on. Although this interrupt may not be cleared, it may be masked by clearing the Power Fail Interrupt Enable bit. POWER FAILURE CIRCUITRY FUNCTIONAL DESCRIPTION Since the clock must be operated from a battery when the main system supply has been turned off, the DP8570A provides circuitry to simplify design in battery backed systems. This circuitry switches over to the back up supply, and isolates the DP8570A from the host system. Figure 6 shows a simplified block diagram of this circuitry, which consists of three major sections; 1) power loss logic: 2) battery switch over logic: and 3) isolation logic. Detection of power loss occurs when PFAIL is low. Debounce logic provides a 30 ms-63 ms debounce time, which will prevent noise on the PFAIL pin from being interpreted as a system failure. After 30 ms-63 ms the debounce logic times out and a signal is generated indicating that system power is marginal and is failing. The Power Fail Interrupt will then be generated. PERIODIC INTERRUPTS DESCRIPTION The Periodic Flag Register contains six flags which are set by real-time generated ``ticks'' at various time intervals, see Figure 5 . These flags constantly sense the periodic signals and may be used whether or not interrupts are enabled. These flags are cleared by any read or write operation performed on this register. 9 FIGURE 5. Interrupt Control Logic Overview TL/F/8638 - 7 Functional Description (Continued) 10 Functional Description (Continued) TL/F/8638 - 8 FIGURE 6. System-Battery Switchover (Upper Left), Power Fail and Lock-Out Circuits (Lower Right) After the generation of a lock-out signal, and eventual switch in of the battery supply, the pins of the TCP will be configured as shown in Table II. Outputs that have a pull-up resistor should be connected to a voltage no greater than VBB. The user may choose to have this power failed signal lockout the TCP's data bus within 30 ms min/63 ms max or to delay the lock-out to enable mP access after power failure is detected. This delay is enabled by setting the delay enable bit in the Routing Register. Also, if the lock-out delay was not enabled the TCP will disconnect itself from the bus within 30 ms min x 63 ms max. If chip select is low when a power failure is detected, a safety circuit will ensure that if a read or write is held active continuously for greater than 30 ms after the power fail signal is asserted, the lock-out will be forced. If a lock-out delay is enabled, the DP8570A will remain active for 480 ms after power fail is detected. This will enable the mP to perform last minute bookkeeping before total system collapse. When the host CPU is finished accessing the TCP it may force the bus lock-out before 480 ms has elapsed by resetting the delay enable bit. The battery switch over circuitry is completely independent of the PFAIL pin. A separate circuit compares VCC to the VBB voltage. As the main supply fails, the TCP will continue to operate from the VCC pin until VCC falls below the VBB voltage. At this time, the battery supply is switched in, VCC is disconnected, and the device is now in the standby mode. If indeterminate operation of the battery switch over circuit is to be avoided, then the voltage at the VCC pin must not be allowed to equal the voltage at the VBB pin. TABLE II. Pin Isolation during a Power Failure Pin CS, RD, WR A0 - A4 D0 - D7 Oscillator TCK, G0, G1 PFAIL INTR, MFO T1 PFAIL e Logic 0 Standby Mode VBB l VCC Locked Out Locked Out Locked Out Not Isolated Not Isolated Not Isolated Locked Out Locked Out Locked Out Not Isolated Locked Out Not Isolated Not Isolated Open Drain The Timer and Interrupt Power Fail Operation bits in the Real-Time Mode Register determine whether or not the timers and interrupts will continue to function after a power fail event. As power returns to the system, the battery switch over circuit will switch back to VCC power as soon as it becomes greater than the battery voltage. The chip will remain in the locked out state as long as PFAIL e 0. When PFAIL e 1 11 Functional Description (Continued) the chip is unlocked, but only after another 30 ms min x 63 ms max debounce time. The system designer must ensure that his system is stable when power has returned. The power fail circuitry contains active linear circuitry that draws supply current from VCC. In some cases this may be undesirable, so this circuit can be disabled by masking the power fail interrupt. The power fail input can perform all lock-out functions previously mentioned, except that no external interrupt will be issued. Note that the linear power fail circuitry is switched off automatically when using VBB in standby mode. TIMER FUNCTIONAL DESCRIPTION The DP8570A contains 2 independent multi-mode timers. Each timer is composed of a 16-bit negative edge triggered binary down counter and associated control. The operation is similar to existing mP peripheral timers except that several features have been enhanced. The timers can operate in four modes, and in addition, the input clock frequency can be selected from a prescaler over a wide range of frequencies. Furthermore, these timers are capable of generating interrupts as well as hardware output signals, and both the interrupt and timer outputs are fully programmable active high, or low, open drain, or push-pull. LOW BATTERY, INITIAL POWER ON DETECT, AND POWER FAIL TIME SAVE There are three other functions provided on the DP8570A to ease power supply control. These are an initial Power On detect circuit, which also can be used as a time keeping failure detect, a low battery detect circuit, and a time save on power failure. On initial power up the Oscillator Fail Flag will be set to a one and the real time clock start bit reset to a zero. This indicates that an oscillator fail event has occurred, and time keeping has failed. The Oscillator Fail flag will not be reset until the real-time clock is started. This allows the system to discriminate between an initial power-up and recovery from a power failure. If the battery backed mode is selected, then bit D6 of the Periodic Flag Register must be written low. This will not affect the contents of the Oscillator Fail Flag. Another status bit is the low battery detect. This bit is set only when the clock is operating under the VCC pin, and when the battery voltage is determined to be less than 2.1V (typical). When the power fail interrupt enable bit is low, it disables the power fail circuit and will also shut off the low battery voltage detection circuit as well. To relieve CPU overhead for saving time upon power failure, the Time Save Enable bit is provided to do this automatically. (See also Reading the Clock: Latched Read.) The Time Save Enable bit, when set, causes the Time Save RAM to follow the contents of the clock. This bit can be reset by software, but if set before a power failure occurs, it will automatically be reset when the clock switches to the battery supply (not when a power failure is detected by the PFAIL pin). Thus, writing a one to the Time Save bit enables both a software write or power fail write. Figure 7 shows the functional block diagram of one of the timers. The timer consists of a 16-bit counter, two 8-bit input registers, two 8-bit output registers, clock prescaler, mode control logic, and output control logic. The timer and the data registers are organized as two bytes for each timer. Under normal operations a read/write to the timer locations will read or write to the data input register. The timer contents can be read by setting the counter Read bit (RD) in the timer control register. TIMER INITIALIZATION The timer's operation is controlled by a set of registers, as listed in Table III. These consist of 2 data input registers and one control register per timer. The data input registers contain the timers count down value. The Timer Control Register is used to set up the mode of operation and the input clock rate. The timer related interrupts can be controlled by programming the Interrupt Routing Register and Interrupt Control Register 0. The timer outputs are configured by the Output Mode Register. TABLE III. Timer Associated Registers SINGLE POWER SUPPLY APPLICATIONS The DP8570A can be used in a single power supply application. To achieve this, the VBB pin must be connected to ground, and the power connected to VCC and PFAIL pins. The Oscillator Failed/Single Supply bit in the Periodic Flag Register should be set to a logic 1, which will disable the oscillator battery reference circuit. The power fail interrupt should also be disabled. This will turn off the linear power fail detection circuits, and will eliminate any quiescent power drawn through these circuits. Until the crystal select bits are initialized, the DP8570A may consume about 50 mA due to arbitrary oscillator selection at power on. (This extra 50 mA is not consumed if the battery backed mode is selected). Register Name Register Select Page Select Address Timer 0 Data MSB Timer 0 Data LSB Timer 0 Control Register Timer 1 Data MSB Timer 1 Data LSB Timer 1 Control Register Interrupt Routing Register Interrupt Control Reg. 0 Output Mode Register X X 0 X X 0 0 1 1 0 0 0 0 0 0 0 0 0 10H 0FH 01H 12H 11H 02H 04H 03H 02H All these registers must be initialized prior to starting the timer(s). The Timer Control Register should first be set to select the timer mode with the timer start/stop bit reset. Then when the timer is to be started the control register should be rewritten identically but with the start/stop bit set. TIMER OPERATION Each timer is capable of operation in one of four modes. As mentioned, these modes are programmed in each timer's Control Register which is described later. All four modes operate in a similar manner. They operate on the two 8-bit data words stored into the Data Input Register. At the beginning of a counting cycle the 2 bytes are loaded into the timer and the timer commences counting down towards zero. The exact action taken when zero is reached depends on the mode selected, but in general, the timer output will change state, and an interrupt will be generated if the timer interrupts are unmasked. 12 Functional Description (Continued) together, so that when either is high the timers are suspended. Suspending the timer causes the same synchronization error that starting the timer does. The range of errors is specified in Table V. INPUT CLOCK SELECTION The input frequency to the timers may be selected. Each timer has a prescaler that gives a wide selection of clocking rates. In addition, the DP8570A has a single external clock input pin that can be selected for either of the timers. Table IV shows the range of programmable clocks available and the corresponding setting in the Timer Control Register. TABLE V. Maximum Synchronization Errors Clock Selected External Crystal Crystal/4 10.7 kHz 1 kHz 100 Hz 10 Hz 1 Hz TABLE IV. Programmable Timer Input Clocks C2 C1 C0 Selected Clock 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 External Crystal Oscillator (Crystal Oscillator)/4 93.5 ms (10.7 kHz) 1 ms (1 kHz) 10 ms (100 Hz) 1/10 Second (10 Hz) 1 Second (1 Hz) Error a Ext. Clock Period a 1 Crystal Clock Period a 1 Crystal Clock Period a 32 ms a 32 ms a 32 ms a 32 ms a 32 ms MODES OF OPERATION Bits M0 and M1 in the Timer Control Registers are used to specify the modes of operation. The mode selection is described in Table VI. Note that the second and third selections are not fixed frequencies, but depend on the crystal oscillator frequency chosen. Since the input clock frequencies are usually running asynchronously to the timer Start/Stop control bit, a 1 clock cycle error may result. This error results when the Start/Stop occurs just after the clock edge (max error). To minimize this error on all clocks an independent prescaler is used for each timer and is designed so that its Start/Stop error is less than 1 clock cycle. The count hold/gate bit in the Timer Control Register and the external enable pins, G0/G1, can be used to suspend the timer operation in modes 0, 1, and 2 (in mode 3 it is the trigger input). The external pin and the register bit are OR'ed TABLE VI. Programmable Timer Modes of Operation M1 M0 Function Modes 0 0 1 1 0 1 0 1 Single Pulse Generator Rate Generator, Pulse Output Square Wave Output Retriggerable One Shot Mode 0 Mode 1 Mode 2 Mode 3 MODE 0: SINGLE PULSE GENERATOR When the timer is in this mode the output will be initially low if the Timer Start/Stop bit is low (stopped). When this mode is initiated the timer output will go high on the next falling edge of the prescaler's input clock, the contents TL/F/8638 - 9 FIGURE 7. DP8570A Timer Block Diagram 13 Functional Description (Continued) for one clock period of the timer clock. Then on the next clock the counter is reloaded automatically and the countdown repeats itself. The output, shown in Figure 9 , is a waveform whose pulse width and period is determined by N, the input register value, and the input clock period: Period e (N a 1) (Clock Period) of the input data registers are loaded into the timer. The output will stay high until the counter reaches zero. At zero the output is reset. The result is an output pulse whose duration is equal to the input clock period times the count value (N) loaded into the input data register. This is shown in Figure 8 . Pulse Width e Clock Period c N An interrupt is generated when the zero count is reached. This can be used for one-time interrupts that are set to occur a certain amount of time in the future. In this mode the Timer Start/Stop bit (TSS) is automatically reset upon zero detection. This removes the need to reset TSS before starting another operation. The count down operation may be temporarily suspended either under software control by setting the Count Hold/ Gate bit in the timer register high, or in hardware by setting the G0 or G1 pin high. The above discussion assumes that the timer outputs were programmed to be non-inverting outputs (active high). If the polarity of the output waveform is wrong for the application the polarity can be reversed by configuring the Output Mode Register. The drive configuration can also be programmed to be push pull or open drain. Pulse Width e Clock Period The G0 or G1 pin and the count hold/gate bit can be used to suspend the appropriate timer countdown when either is high. Again, the output polarity is controllable as in mode 0. If enabled, an interrupt is generated whenever the zero count is reached. This can be used to generate a periodic interrupt. MODE 2: SQUARE WAVE GENERATOR This mode is also cyclic but in this case a square wave rather than a pulse is generated. The output square wave period is determined by the value loaded into the timer input register. This period and the duty cycle are: Period e 2(N a 1) (Clock Period) Duty Cycle e 0.5 When the timer is stopped the output will be low, and when the Start/Stop bit is set high the timer's counter will be loaded on the next clock falling transition and the output will be set high. The output will be toggled after the zero count is detected and the counter will then be reloaded, and the cycle will continue. Thus, every N a 1 counts the output gets toggled, as shown in Figure 10 . Like the other modes the timer operation can be suspended either by software setting the count hold/gate bit (CHG) in the Timer Control Register or by using the gate pins. An interrupt will be generated every falling edge of the timer output, if enabled. MODE 1: RATE GENERATOR When operating in this mode the timer will operate continuously. Before the timer is started its output is low. When the timer is started the input data register contents are loaded into the counter on the negative clock edge and the output is set high (again assuming the Output Mode Register is programmed active high). The timer will then count down to zero. Once the zero count is reached the output goes low TL/F/8638 - 10 FIGURE 8. Typical Waveforms for Timer Mode 0 (Timer Output Programmed Active High) TL/F/8638 - 11 FIGURE 9. Timing Waveforms for Timer Mode 1 (Timer Output Programmed Active High) 14 Functional Description (Continued) read. Experimental results indicate that the typical error rate Is approximately one per 29,000 under the following conditions: Timer clock frequency of 5 MHz. Computer: 386/33 MHz PC/AT Program: Microsoft ``C'' 6.0, reading and saving timer contents in a continuous loop. Those users who find the error rate unacceptable may reduce the problem effectively to zero by employing a hardware work-around that synchronizes the writing of the read bit to the timer control register with respect to the decrementing clock. Refer to Figure 1 in Appendix A, for a suggested hardware work-around. A software work-around can reduce the errors but not as substantial as a hardware work-around. Software workarounds are based on observations that the read following a bad read appeared to be valid. This problem concerns statistical probability and is similar to metastability issues. For more information on metastability, refer to 1991 IEEE transactions on Custom Integrated Circuits Conference. paper by T.J. Gabara of AT&T Bell Laboratories, page 29.4.1. Normally reading the timer data register addresses, 0FH and 10H for Timer 0 and 11H and 12H for Timer 1 will result in reading the input data register which contains the preset value for the timers. To read the contents of a timer, the mP first sets the timer read bit in the appropriate Timer Control Register high. This will cause the counters contents to be latched to 2-bit - 8-bit output registers, and will enable these registers to be read if the mP reads the timers input data register addresses. On reading the LSB byte the timer read bit is internally reset and subsequent reads of the timer locations will return the input register values. TL/F/8638 - 12 FIGURE 10. Timing Waveforms for Timer Mode 2 (Timer Output Programmed Active High) MODE 3: RETRIGGERABLE ONE SHOT This mode is different from the previous three modes in that this is the only mode which uses the external gate to trigger the output. Once the timer Start/Stop bit is set the output stays inactive, and nothing happens until a positive transition is received on the G1 or G0 pins, or the Count Hold/ Gate (CHG) bit is set in the timer control register. When a transition ocurs the one shot output is set active immediately; the counter is loaded with the value in the input register on the next transition of the input clock and the countdown begins. If a retrigger occurs, regardless of the current counter value, the counters will be reloaded with the value in the input register and the counter will be restarted without changing the output state. See Figure 11 . A trigger count can occur at any time during the count cycle and can be a hardware or software signal (G0, G1 or CHG). In this mode the timer will output a single pulse whose width is determined by the value in the input data register (N) and the input clock period. Pulse Width e Clock Period c N Before entering mode 3, if a spurious edge has occurred on G0/G1 or the CHG bit is set to logic 1, then a pulse will appear at MFO or T1 or INTR output pin when the timer is started. To ensure this does not happen, do the following steps before entering mode 3: Configure the timer for mode 0, load a count of zero, then start the timer. The timer will generate an interrupt only when it reaches a count of zero. This timer mode is useful for continuous ``watch dog'' timing, line frequency power failure detection, etc. DETAILED REGISTER DESCRIPTION There are 5 external address bits: Thus, the host microprocessor has access to 32 locations at one time. An internal switching scheme provides a total of 67 locations. This complete address space is organized into two pages. Page 0 contains two blocks of control registers, timers, real time clock counters, and special purpose RAM, while page 1 contains general purpose RAM. Using two blocks enables the 9 control registers to be mapped into 5 locations. The only register that does not get switched is the Main Status Register. It contains the page select bit and the register select bit as well as status information. A memory map is shown in Figure 2 and register addressing in Table VII. They show the name, address and page locations for the DP8570A. READING THE TIMERS National has discovered that some users may encounter unacceptable error rates for their applications when reading the timers on the fly asynchronously. When doing asynchronous reads of the timers, an error may occur. The error is that a successive read may be larger than the previous TL/F/8638 - 13 FIGURE 11. Timing Waveforms for Timer Mode 3, Output Programmed Active High 15 Functional Description (Continued) MAIN STATUS REGISTER TABLE VII. Register/Counter/RAM Addressing for DP8570A A0-4 PS RS (Note 1) (Note 2) Description CONTROL REGISTERS 00 01 02 03 04 01 02 03 04 X 0 0 0 0 0 0 0 0 X 0 0 0 0 1 1 1 1 Main Status Register Timer 0 Control Register Timer 1 Control Register Periodic Flag Register Interrupt Routing Register Real Time Mode Register Output Mode Register Interrupt Control Register 0 Interrupt Control Register 1 TL/F/8638 - 14 COUNTERS (CLOCK CALENDAR) 05 06 07 08 09 0 0 0 0 0 X X X X X 0A 0B 0C 0D 0E 0 0 0 0 0 X X X X X The Main Status Register is always located at address 0 regardless of the register block or the page selected. D0: This read only bit is a general interrupt status bit that is taken directly from the interrupt pins. The bit is a one when an interrupt is pending on either the INTR pin or the MFO pin (when configured as an interrupt). This is unlike D3 - D5 which can be set by an internal event but may not cause an interrupt. This bit is reset when the interrupt status bits in the Main Status Register are cleared. D1 - D5: These five bits of the Main Status Register are the main interrupt status bits. Any bit may be a one when any of the interrupts are pending. Once an interrupt is asserted the mP will read this register to determine the cause. These interrupt status bits are not reset when read. Except for D1, to reset an interrupt a one is written back to the corresponding bit that is being tested. D1 is reset whenever the PFAIL pin e logic 1. This prevents loss of interrupt status when reading the register in a polled mode. D1, D3 - D5 are set regardless of whether these interrupts are masked or not by bits D6 and D7 of Interrupt Control Registers 0 and 1. D6 and D7: These bits are Read/Write bits that control which register block or RAM page is to be selected. Bit D6 controls the register block to be accessed (see memory map). The memory map of the clock is further divided into two memory pages. One page is the registers, clock and timers, and the second page contains 31 bytes of general purpose RAM. The page selection is determined by bit D7. 1/100, 1/10 Seconds (0 - 99) Seconds (0 - 59) Minutes (0 - 59) Hours (1 - 12, 0 - 23) Days of Month (1 - 28/29/30/31) Months (1 - 12) Years (0 - 99) Julian Date (LSB) (0 - 99) (Note 3) Julian Date (0 - 3) Day of Week (1 - 7) TIMER DATA REGISTERS 0F 10 11 12 0 0 0 0 X X X X Timer 0 LSB Timer 0 MSB Timer 1 LSB Timer 1 MSB TIME COMPARE RAM 13 14 15 0 0 0 X X X 16 0 X 17 0 X 18 0 X Sec Compare RAM Min Compare RAM Hours Compare RAM DOM Compare RAM Months Compare RAM DOW Compare RAM (0 - 59) (0 - 59) (1 - 12, 0 - 23) (1 - 28/29/30/31) (1 - 12) (1 - 7) TIME SAVE RAM 19 1A 1B 1C 1D 0 0 0 0 0 X X X X X Seconds Time Save RAM Minutes Time Save RAM Hours Time Save RAM Day of Month Time Save RAM Months Time Save RAM 1E 1F 0 0 1 X RAM RAM/Test Mode Register 01 - 1F 1 X 2nd Page General Purpose RAM Note 1: PSPage Select (Bit D7 of Main Status Register) Note 2: RSRegister Select (Bit D6 of Main Status Register) Note 3: The LSB counters count 0-99 until the hundreds of days counter reaches 3. Then the LSB counters count to 65 or 66 (if a leap year). The rollover is from 365/366 to 1. 16 Functional Description (Continued) D0 - D5: These bits are set by the real time rollover events: (Time Change e 1). The bits are reset when the register is read and can be used as selective data change flags. D6: This bit performs a dual function. When this bit is read, a one indicates that an oscillator failure has occurred and the time information may have been lost. Some of the ways an oscillator failure may be caused are: failure of the crystal; shorting OSC IN or OSC OUT to GND or VCC; removal of crystal; removal of battery when in the battery backed mode (when a `0' is written to D6); lowering the voltage at the VBB pin to a value less than 2.2V when in the battery backed mode. Bit D6 is automatically set to 1 on initial power-up or an oscillator fail event. The oscillator fail flag is reset by writing a one to the clock start/stop bit in the Real Time Mode Register, with the crystal oscillating. When D6 is written to, it defines whether the TCP is being used in battery backed (normal) or in a single supply mode application. When set to a one this bit configures the TCP for single power supply applications. This bit is automatically set on initial power-up or an oscillator fail event. When set, D6 disables the oscillator reference circuit. The result is that the oscillator is referenced to VCC. When a zero is written to D6 the oscillator reference is enabled, thus the oscillator is referenced to VBB. This allows operation in standard battery standby applications. At initial power on, if the DP8570A is going to be programmed for battery backed mode, the VBB pin should be connected to a potential in the range of 2.2V to VCC b 0.4V. For single supply mode operation, the VBB pin should be connected to GND and the PFAIL pin connected to VCC. D7: Writing a one to this bit enables the test mode register at location 1F (see Table VII). This bit should be forced to zero during initialization for normal operation. If the test mode has been entered, clear the test mode register before leaving test mode. (See separate test mode application note for further details.) TIMER 0 AND 1 CONTROL REGISTER TL/F/8638 - 15 These registers control the operation of the timers. Each timer has its own register. D0: This bit will Start (1) or Stop (0) the timer. When the timer is stopped the timer's prescaler and counter are reset, and the timer will restart from the beginning when started again. In mode 0 on time out the TSS bit is internally reset. D1 and D2: These control the count mode of the timers. See Table VI. D3 - D5: These bits control which clock signal is applied to the timer's counter input. There is one external clock input pin (TCK) and either (or both) timer(s) can be selected to run off this pin: refer to Table IV for details. D6: This is the read bit. If a one is written into this location it will cause the contents of the timer to be latched into a holding register, which can be read by the mP at any time. Reading the least significant byte of the timer will reset the RD bit. The timer read cycle can be aborted by writing RD to zero. D7: The CHG bit has two mode dependent functions. In modes 0 through 2 writing a one to this bit will suspend the timer operation (without resetting the timer prescaler). However, in mode 3 this bit is used to trigger or re-trigger the count sequence as with the gate pins. If retriggering is desired using the CHG bit, it is not necessary to write a zero to this location prior to the re-trigger. The action of further writing a one to this bit will re-trigger the count. INTERRUPT ROUTING REGISTER PERIODIC FLAG REGISTER TL/F/8638 - 17 D0 - D4: The lower 5 bits of this register are associated with the main interrupt sources created by this chip. The purpose of this register is to route the interrupts to either the MFO (multi-function pin), or to the main interrupt pin. When any bit is set the associated interrupt signal will be sent to the MFO pin, and when zero it will be sent to the INTR pin. TL/F/8638 - 16 The Periodic Flag Register has the same bit for bit correspondence as Interrupt Control Register 0 except for D6 and D7. For normal operation (i.e., not a single supply application) this register must be written to on initial power up or after an oscillator fail event. D0-D5 are read only bits, D6 and D7 are read/write. 17 Functional Description (Continued) D2: The count mode for the hours counter can be set to either 24 hour mode or 12 hour mode with AM/PM indicator. A one will place the clock in 12 hour mode. D5: The Delay Enable bit is used when a power fail occurs. If this bit is set, a 480 ms delay is generated internally before the mP interface is locked out. This will enable the mP to access the registers for up to 480 ms after it receives a power fail interrupt. After a power failure is detected but prior to the 480 ms delay timing out, the host mP may force immediate lock out by resetting the Delay Enable bit. Note if this bit is a 0 when power fails then after a delay of 30 ms min/63 ms max the mP cannot read the chip. D6: This read only bit is set and reset by the voltage at the VBB pin. It can be used by the mP to determine whether the battery voltage at the VBB pin is getting too low. A comparator monitors the battery and when the voltage is lower than 2.1V (typical) this bit is set. The power fail interrupt must be enabled to check for a low battery voltage. D7: Time Save Enable bit controls the loading of real-timeclock data into the Time Save RAM. When a one is written to this bit the Time Save RAM will follow the corresponding clock registers, and when a zero is written to this bit the time in the Time Save RAM is frozen. This eliminates any synchronization problems when reading the clock, thus negating the need to check for a counter rollover during a read cycle. This bit must be set to a one prior to power failing to enable the Time Save feature. When the power fails this bit is automatically reset and the time is saved in the Time Save RAM. D3: This bit is the master Start/Stop bit for the clock. When a one is written to this bit the real time counter's prescaler and counter chain are enabled. When this bit is reset to zero the contents of the real time counter is stopped and the prescaler is cleared. When the TCP is initially powered up this bit will be held at a logic 0 until the oscillator starts functioning correctly after which this bit may be modified. If an oscillator fail event occurs, this bit will be reset to logic 0. D4: This bit controls the operation of the interrupt output in standby mode. If set to a one it allows Alarm, Periodic, and Power Fail interrupts to be functional in standby mode. Timer interrupts will also be functional provided that bit D5 is also set. Note that the MFO and INTR pins are configured as open drain in standby mode. If bit D4 is set to a zero then interrupt control register 0 and bits D6 and D7 of interrupt control register 1 will be reset when the TCP enters the standby mode (VBB l VCC). They will have to be re-configured when system (VCC) power is restored. D5: This bit controls the operation of the timers in standby mode. If set to a one the timers will continue to function when the TCP is in standby mode. The input pins TCK, G0, G1 are locked out in standby mode, and cannot be used. Therefore external control of the timers is not possible in standby mode. Note also that MFO and T1 pins are automatically reconfigured open drain during standby. D6 and D7: These two bits select the crystal clock frequency as per the following table: REAL TIME MODE REGISTER TL/F/8638-18 LY0 Leap Year Counter 0 0 1 1 0 1 0 1 Leap Year Current Year Leap Year Last Year Leap Year 2 Years Ago Leap Year 3 Years Ago XT0 Crystal Frequency 0 0 1 1 0 1 0 1 32.768 kHz 4.194304 MHz 4.9152 MHz 32.000 kHz All bits are Read/Write, and any mode written into this register can be determined by reading the register. On initial power up these bits are random. D0 - D1: These are the leap year counter bits. These bits are written to set the number of years from the previous leap year. The leap year counter increments on December 31st and it internally enables the February 29th counter state. This method of setting the leap year allows leap year to occur whenever the user wishes to, thus providing flexibility in implementing Japanese leap year function. LY1 XT1 OUTPUT MODE REGISTER TL/F/8638 - 19 18 Functional Description (Continued) periodic time chosen, but after the first interrupt all subsequent interrupts will be spaced correctly. These interrupts are useful when minute, second, real time reading, or task switching is required. When all six bits are written to a 0 this disables periodic interrupts from the Main Status Register and the interrupt pin. D6 and D7: These are individual timer enable bits. A one written to these bits enable the timers to generate interrupts to the mP. D0: This bit, when set to a one makes the T1 (timer 1) output pin active high, and when set to a zero, it makes this pin active low. D1: This bit controls whether the T1 pin is an open drain or push-pull output. A one indicates push pull. D2: This bit, when set to a one makes the INTR output pin active high, and when set to a zero, it makes this pin active low. D3: This bit controls whether the INTR pin is an open drain or push-pull output. A one indicates push-pull. D4: This bit, when set to a one makes the MFO output pin active high, and when set to a zero, it makes this pin active low. D5: This bit controls whether the MFO pin is an open drain or push-pull output. A one indicates push-pull. D6 and D7: These bits are used to program the signal appearing at the MFO output, as follows: D7 D6 MFO Output Signal 0 0 1 0 1 X 2nd Interrupt Timer 0 Waveform Buffered Crystal Oscillator INTERRUPT CONTROL REGISTER 1 TL/F/8638 - 21 D0 - D5: Each of these bits are enable bits which will enable a comparison between an individual clock counter and its associated compare RAM. If any bit is a zero then that clock-RAM comparator is set to the ``always equal'' state and the associated TIME COMPARE RAM byte can be used as general purpose RAM. However, to ensure that an alarm interrupt is not generated at bit D3 of the Main Status Register, all bits must be written to a logic zero. D6: In order to generate an external alarm compare interrupt to the mP from bit D3 of the Main Status Register, this bit must be written to a logic 1. If battery backed mode is selected and the DP8570A is in standby (VBB l VCC), then this bit is controlled by D4 of the Real Time Mode Register. D7: The MSB of this register is the enable bit for the Power Fail Interrupt. When this bit is set to a one an interrupt will be generated to the mP when PFAIL e 0. If battery backed mode is selected and the DP8570A is in standby (VBB l VCC), then this bit is controlled by D4 of the Real Time Mode Register. This bit also enables the low battery detection analog circuitry. If the user wishes to mask the power fail interrupt, but utilize the analog circuitry, this bit should be enabled, and the Routing Register can be used to route the interrupt to the MFO pin. The MFO pin can then be left open or configured as the Timer 0 or buffered oscillator output. INTERRUPT CONTROL REGISTER 0 TL/F/8638 - 20 If battery backed mode is selected and the DP8570A is in standby (VBB l VCC), then all bits are controlled by D4 of the Real Time Mode Register. D0 - D5: These bits are used to enable one of the selected periodic interrupts by writing a one into the appropriate bit. These interrupts are issued at the rollover of the clock. For example, the minutes interrupt will be issued whenever the minutes counter increments. In all likelihood the interrupt will be enabled asynchronously with the real time change. Therefore, the very first interrupt will occur in less than the 19 Control and Status Register Address Bit Map D7 D6 Main Status Register PS e 0 R/W R/W Page Select D5 RS e 0 R/W1 Register Select Timer 1 Interrupt Timer 0 Control Register PS e 0 Count Hold Gate Timer Read Timer Read Timer 0 Interrupt RS e 0 Input Clock Select C2 Timer 1 Control Register PS e 0 Count Hold Gate D4 D3 ADDRESS e 00H R/W1 R/W1 Periodic Flag Register PS e 0 R/W R/W4 RS e 0 10 ms Flag Interrupt Routing Register PS e 0 R/W R6 R/W RS e 0 R/W Time Save Enable Low Battery Flag Real Time Mode Register PS e 0 Crystal Freq. XT1 Crystal Freq. XT0 Output Mode Register PS e 0 MFO as Crystal MFO as Timer 0 Timer 1 Interrupt Enable Timer 0 Interrupt Enable 1 ms Interrupt Enable Interrupt Control Register 1 PS e 0 Power Fail Interrupt Enable Alarm Interrupt Enable DOW Interrupt Enable 100 ms Flag Timer 0 Int. Route MFO/INT R3 Periodic Interrupt Power Fail Interrupt Interrupt Status Mode Select M1 Mode Select M0 Timer Start/Stop All Bits R/W Mode Select M1 Mode Select M0 Timer Start/Stop All Bits R/W 1. Reset by writing 1 to bit. 2. Set/reset by voltage at PFAIL pin. 3. Reset when all pending interrupts are removed. R5 R5 R5 Seconds Flag 10 Second Flag Minute Flag 4. Read Osc fail Write 0 BattBacked Mode Write 1 Single Supply Mode 5. Reset by positive edge of read. R/W R/W R/W Alarm Int. Route MFO/INT Periodic Int. Route MFO/INT Power Fail Int. Route MFO/INT 6. Set and reset by VBB voltage. 12/24 Hr. Mode Leap Year MSB Leap Year LSB All Bits R/W INTR Active HI/LO T1 PP/OD Address e 01H Interrupt EN on Back-Up RS e 1 Interrupt Control Register 0 PS e 0 R2 Address e 04H R/W RS e 1 MFO PP/OD Input Clock Select C0 Timer 1 Int. Route MFO/INT Timers EN on Back-Up R/W1 Address e 03H R5 1 ms Flag Power Fail Delay Enable D0 Address e 02H R5 Osc. Fail/ Single Supply Input Clock Select C0 Input Clock Select C1 R5 Test Mode D1 Address e 01H Input Clock Select C1 RS e 0 Input Clock Select C2 Alarm Interrupt D2 Clock Start/Stop Address e 02H MFO Active HI/LO RS e 1 10 ms Interrupt Enable RS e 1 Month Interrupt Enable INTR PP/OD T1 All Bits R/W Active HI/LO Address e 03H 100 ms Interrupt Enable Seconds Interrupt Enable 10 Second Interrupt Enable Minute Interrupt Enable All Bits R/W Minute Interrupt Enable Second Interrupt Enable All Bits R/W Address e 04H DOM Interrupt Enable 20 Hours Interrupt Enable Application Hints running. During the software loop, RAM, real time counters, output configuration, interrupt control and timer functions may be initialized. Suggested Initialization Procedure for DP8570A in battery backed applications that use the VBB pin 1. Enter the test mode by writing a 1 to bit D7 in the Periodic Flag Register. 2. Write zero to the RAM/TEST mode Register located in page 0, address HEX 1F. 3. Leave the test mode by writing a 0 to bit D7 in the Periodic Flag Register. Steps 1, 2, 3 guarantee that if the test mode had been entered during power on (due to random pulses from the system), all test mode conditions are cleared. Most important is that the OSC Fail Disable bit is cleared. Refer to AN-589 for more information on test mode operation. 4. After power on (VCC and VBB powered), select the correct crystal frequency bits (D7, D6 in the Real Time Mode Register) as shown in Table I. 6. Test bit D6 in the Periodic Flag Register: IF a 1, go to 5.1. If this bit remains a 1 after 3 seconds, then abort and check hardware. The crystal may be defective or not installed. There may be a short at OSC IN or OSC OUT to VCC or GND, or to some impedance that is less than 10 MX. IF a 0, then the oscillator is running, go to step 7. 7. Write a 0 to bit D6 in the Periodic Flag Register. This action puts the clock chip in the battery backed mode. This mode can be entered only if the osc fail flag (bit D6 of the Periodic Flag Register) is a 0. Reminder, Bit D6 is a dual function bit. When read, D6 returns oscillator status. When written, D6 causes either the Battery Backed Mode, or the Single Supply Mode of operation. The only method to ensure the chip is in the battery backed mode is to measure the waveform at the OSC OUT pin. If the battery backed mode was selected successfully, then the peak to peak waveform at OSC OUT is referenced to the battery voltage. If not in battery backed mode, the waveform is referenced to VCC. The measurement should be made with a high impedance low capacitance probe (10 MX, 10 pF oscilloscope probe or better). Typical peak to peak swings are within 0.6V of VCC and ground respectively. 8. Write a 1 to bit D7 of Interrupt Control Register 1. This action enables the PFAIL pin and associated circuitry. 9. Write a 1 to bit D4 of the Real Time Mode Register. This action ensures that bit D7 of Interrupt Control Register 1 remains a 1 when VBB l VCC (Standby Mode). 10. Initialize the rest of the chip as needed. TABLE I Frequency D7 D6 32.768 kHz 0 0 4.194304 MHz 0 1 4.9152 MHz 1 0 32.0 kHz 1 1 5. Enter a software loop that does the following: Set a 3 second (approx.) software counter. The crystal oscillator may take 1 second to start. 5.1 Write a 1 to bit D3 in the Real Time Mode Register (try to start the clock). Make sure the crystal select bits remain the same as in step 1. Under normal operation, this bit can be set only if the oscillator is Typical Application TL/F/8638 - 22 *These components may be necessary to meet UL requirements for lithium batteries. Consult battery manufacturer. 21 Appendix A TL/F/8638 - 30 FIGURE A1. Typical Interface Where the ``Write Strobe'' is Synchronized to the Decrementing Clock of the Timer 22 Typical Performance Characteristics Operating Current vs Supply Voltage (Single Supply Mode FOSC e 32.768 kHz) Operating Current vs Supply Voltage (Battery Backed Mode FOSC e 32.768 kHz) TL/F/8638 - 26 TL/F/8638 - 27 Standby Current vs Power Supply Voltage (FOSC e 32.768 kHz) Standby Current vs Power Supply Voltage FOSC e 4.194304 MHz TL/F/8638 - 28 TL/F/8638 - 29 23 24 Physical Dimensions inches (millimeters) Molded Dual-In-Line Package (N) Order Number DP8570AN NS Package Number N28B 25 DP8570A Timer Clock Peripheral (TCP) Physical Dimensions inches (millimeters) (Continued) Plastic Chip Carrier Package (V) Order Number DP8570AV NS Package Number V28A LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. National Semiconductor Corporation 2900 Semiconductor Drive P.O. Box 58090 Santa Clara, CA 95052-8090 Tel: 1(800) 272-9959 TWX: (910) 339-9240 National Semiconductor GmbH Livry-Gargan-Str. 10 D-82256 F4urstenfeldbruck Germany Tel: (81-41) 35-0 Telex: 527649 Fax: (81-41) 35-1 National Semiconductor Japan Ltd. Sumitomo Chemical Engineering Center Bldg. 7F 1-7-1, Nakase, Mihama-Ku Chiba-City, Ciba Prefecture 261 Tel: (043) 299-2300 Fax: (043) 299-2500 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National Semiconductor Hong Kong Ltd. 13th Floor, Straight Block, Ocean Centre, 5 Canton Rd. Tsimshatsui, Kowloon Hong Kong Tel: (852) 2737-1600 Fax: (852) 2736-9960 National Semiconductores Do Brazil Ltda. Rue Deputado Lacorda Franco 120-3A Sao Paulo-SP Brazil 05418-000 Tel: (55-11) 212-5066 Telex: 391-1131931 NSBR BR Fax: (55-11) 212-1181 National Semiconductor (Australia) Pty, Ltd. Building 16 Business Park Drive Monash Business Park Nottinghill, Melbourne Victoria 3168 Australia Tel: (3) 558-9999 Fax: (3) 558-9998 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated