Embedded Power for
Business-Critical Continuity
LDO10C Series
50 Watts
C-Class Non-Isolated
Special Features
•10 A current rating
Adjustable output voltage:
0.59 - 5.1 V
•Excellent transient response
•Power enable (5 pin model)
•Minimum airflow
Small package
•Termination voltage
capability
•RoHS compliant
Total Power: 50 Watts
Input Voltage: 3 - 13.8 Vdc
No. of Outputs: Single
Output
SXX06E Rev. 08.01.06 Page 1 of 2
Electrical Specifications
Output voltage See Note 5 0.59 - 5.1 V
Output setpoint accuracy 0.1% trim resistors ± 1.0%
Line regulation Low line to high line ± 0.2%
Load regulation Full load to min. load ± 0.5%
Min./max. load 0 A/10 A
Overshoot At turn-on 0.5% max.
Undershoot At turn-off 100 mV max.
Ripple and noise
5 Hz to 20 MHz See Note 1 20 mV
Vin = 5 V,
Vout = 2.5 V
Transient response See Notes 1, 2 130 mV max. deviation 15 µs recov-
ery to within regulation band
Input voltage range 3 - 13.8 Vdc
Input current Minimum load
Remote OFF 50 mA
5 mA
Input current (max.) See Note 3 10 A @ lo max.
Start-up time Power up
Remote ON/OFF 3 ms
2 ms
Input
Safety
UL, cUL CAN/CSA 22.2
No. E139421
V Product Service (EN60950)
Certificate No. TBD
CB Report and
Certificate to IEC60950
Rev. 01.19.12_36
LDO10C
1 of 5
Embedded Power for
Business-Critical Continuity
Thermal performance
See Note 5
Operating ambient, temperature
Non-operating
-40 °C to +85 °C
-40 °C to +125 °C
Short-circuit Hiccup, non-latching
Input See Note 6 0 µF
Output See Note 7 0 µF
Protection
Environmental Specifications
Output
Power
(Max.)
Input
Voltage
OVP Output
Voltage
Output
Current
(Min.)
Output
Current
(Max.)
Efciency
(Typical)
Regulation
Line Load
Model
Number (3,5)
50 W 3 - 13.8 Vdc N/A 0.59 - 5.1 V 0 A 10 A 94% ± 0.2% ± 0.5% LDO10C-005W05-VJ
50 W 3 - 13.8 Vdc N/A 0.59 - 5.1 V 0 A 10 A 94% ± 0.2% ± 0.5% LDO10C-005W05-HJ
50 W 3 - 13.8 Vdc N/A 0.59 - 5.1 V 0 A 10 A 94% ± 0.2% ± 0.5% LDO10C-005W05-SJ
Ordering Information
Recommended System Capacitance
Efficiency (high input) Vin=5 V, Vo=2.5 V, lo=10 A 91% typical
Switching frequency Fixed 620 kHz
Approvals and standards
(pending) EN60950
UL/cUL6950
Material flammability UL94V-0
Weight 1.899 g (0.067 oz.)
MTBF 12 V @ 40 °C,
100% load
Bellcore 332
> 8,220,210 hours
Coplanarity Surface mount models 150 µm
General
Rev. 01.19.12_36
LDO10C
2 of 5
Embedded Power for
Business-Critical Continuity
Notes:
1 Measured as per recommended system capacitance. See Application Note
186.
2 di/dt = 10 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo to full lo and
full lo to 0.50.
3 External input fusing is recommended.
4 Additional part numbers may be available with different output voltages.
5 Airflow dependent, 100 LFM minimum required.
6 No capacitors needed for ripple current capability.
7 No capacitors needed for stability.
8 NOTICE: the input voltage must be greater than the programmed output
voltage. the max duty cycle is 95%. These non-isolated dc-dc modules are
buck converters.
Product Family
Product Family
LDO = C-Class
LDO Series
Rated Output Current
Rated Output Current
10 = 10 Amp
Output Voltage
Output Voltage
05 = 0.59-5.1 V
Performance
Performance
C = Cost Optimized
Number of Pins and
Type of Output
Number of Pins and
Type of Output
5 W = 5 Pins and Wide
Output
Input Voltage
Input Voltage
00 = 3 - 13.8 V
RoHS Compliance (8)
RoHS Compliance
J = Pb free (RoHS
6/6 compliant)
Y = non PB-free
(TSE 5/6 compliant)
Output Voltage Adjustment of the LDO03C Series
Part Number System with Options
The ultra-wide output voltage trim range offers major advantages to users who
select the LDO010C series. It is no longer necessary to purchase a variety of
modules in order to cover different output voltages. The output voltage can be
trimmed in a range of 0.59 - 5.1 Vdc. When the LDO03C converter leaves the
factory, the output has been adjusted to the default voltage of 0.59 V.
Mounting Option
Mounting Option
V = Vertical
H = Horizontal
S = Surface
LDO 10 C 00 5W 05 V J
3
2
1
4
5
LD O10C
Remote ON/OFF
Vin
GND
Rtrim
(for trim
down)
Cin
R
L
O
A
D
Vou
t
Cout
Figure 1: Standard Application Drawing
Rev. 01.19.12_36
LDO10C
3 of 5
Embedded Power for
Business-Critical Continuity
Vertical Mount
Mechanical Drawings
Horizontal Mount
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
.071 .050
.410
.650
4X .067
TYP
.160±.010
.030
.131
.34
REF.055
REF.062
MAX.460
.025 .001
SQ PINS TYP
.071 .050
.410
.650
4X .067
TYP
.160±.010
.030
.131
.34
REF.055
REF.062
MAX.460
.025 .001
SQ PINS TYP
Figure 2: Vertical Mount Mechanical Drawing
Figure 3: Horizontal Mount Mechanical Drawing
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
6. Mech Pin
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
Rev. 01.19.12_36
LDO10C
4 of 5
.071
TYP
.050
.067
.650
.410
4X
.035
.580
.545 MAX
.125 TYP
.055 REF
REF.062
.120 TYP
.025±.001
SQ PIN TYP
6 PLACES
.071
TYP
.050
.067
.650
.410
4X
.035
.580
.545 MAX
.125 TYP
.055 REF
REF.062
.120 TYP
.025±.001
SQ PIN TYP
6 PLACES
5 1
5 1
6
Rev. 01.19.12_36
LDO10C
5 of 5
Embedded Power for
Business-Critical Continuity
SXX06E Rev. 08.01.06 Page 1 of 2
Surface Mount
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
6. Mech Pin
Figure 4: Surface Mount Mechanical Drawing
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)
3 Places ± 0.010 (± 0.25)
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower.com
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
1/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/
EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
0 (0.00)
0.071 (1.80)
0.138 (3.51)
0.205 (5.21)
0.272 (6.91)
0.339 (8.61)
0.050 (1.27)
0.360 (9.14)
0.410 (10.41)
0.650 (16.51)
0.035 (0.89)
REF
0.062 (1.57) REF
0.040 (1.02)
REF
0.52 (13.13)
0.055 (1.40) REF
0.125 (3.18) TYP
0.025 (0.64) REF
1
76
5
LDO10C-
005W05-
7. Mech Pin
15
67