Circuit and Surge Protection Protection Solutions Catalog North America Contents Circuit and Surge Protection Branch Rated and Supplementary Circuit Protection Introduction 3 BR Series - AC 277/480V rated 4 9926 Series - Model QL - AC 240V rated 11 9926 Series - Model QY for DC 80V/125V rated 14 SU Series - AC 277/480V rated 15 9926 Series - Model QZ - 277/480V rated 22 9926 Series - Ground Fault Current Interrupt 24 Mounting Options, Accessories, Trip Curves 25 CB4200 Series - Pushbutton trip/reset, AC/DC rated 27 CB2200 Series - Lever Type with aux contact, AC/DC rated 29 CB9100 Series - AC/DC rated, up to 63A AC 31 ESX 10-T 24 VDC - up to 12A 33 ESX 10-TC 12 VDC - up to 10A 41 Lighting and Surge Protection for LV Distribution and AC - powered Devices SPD II 1 Series - for LV A.C. Distribution and DC Photovoltaic applications 47 SPD II & III Series - for LV A.C. Distribution and AC device applications 52 VARITECTOR - Surge Protection for Control I/O Signals Quick Selection Guide 59 Certification 62 Lighting and surge protection for control and instrumentation signals 64 VARITECTOR SPC - Overview 66 VARITECTOR SPC - Surge protectors with plug / base construction. 72 V-TEST - hand-held tester for VSPC 112 VARITECTOR SSC - Overview 115 Electronic (DC) Circuit Protection VARITECTOR SSC 6AN - 6 Pole surge protectors in high density terminal construction 120 VARITECTOR SSC 4AN - 4 Pole surge protectors in high density terminal construction 144 Lighting and Surge Protection for Measurement and Control Systems Instrinsically Safe Circuit (Ex Zone) Surge Protection - MTL Surge Protection for Data Signals 158 VARITECTOR SPC EX - for hazardous locations requiring ATEX approval 159 V DATA 167 VARITECTOR SSC EX - for hazardous locations requiring ATEX approval 169 Introduction 171 SD Series 178 SLP Series 180 MA15 Series 181 TP48 Series 182 Glossary 183 1 Weidmuller Catalogs at a Glance Catalog 1: Modular Terminal Blocks * P-Series (Push-in) * I-Series (IDC) * Power Distribution Blocks and Fuse Blocks * * * * Stud Style (Screw clamp) Z-Series (Tension clamp) W-Series (Screw clamp) Multi-function Blocks * * * * Cutting Stripping Crimping Screwdrivers * Automatic Machines * Ferrules Catalog 2: PCB Terminals and Connectors Catalog 7: Marking Systems Catalog 3: RockStar(R)- Heavy Duty Connectors Catalog 8: Sensor Actuator Interface Catalog 4.1: Analog Signal Conditioning Catalog 9: Industrial Ethernet Catalog 4.2: Relays and Optocouplers Catalog 10: Short Form Catalog Catalog 4.3: Power Delivery Catalog 11: Circuit and Surge Protection Catalog 4.4: Surge Protection Catalog 12: Wireless I/O and Ethernet Connectivity Catalog 5: Enclosures and Cable Glands Catalog u-remote: Distributed I/O Solutions * * * * * * * * * * * * * * * * Space Saving Technologies Wide Variety of Clamping Technologies Pitches Ranging from 3.50 mm to 15.00 mm Orientations Ranging from 90 to 270 Inserts Modular System Housings IP65 and IP68 Cable Glands Intrinsically Safe Conditioners Signal Converters and Monitoring Devices Indicators and Configurable Displays Fieldbus Distribution Boxes Mechanical Relays Solid-State (Opto) Relays Power Solid-State Relays Multifunction Relays and Timers * Power Supplies * UPS Control Units * Battery Back Up Units * * * * Surge Protection for Low-Voltage Surge Protection for Instrumentation and Control Surge Protection for Data Interfaces Surge Protection for Photovoltaic Systems * Enclosures * Cable Glands * Cabtite (Cable Entry System) 2 Catalog 6: Tools * * * * * * * * * * * * Terminal Markers Wire and Cable Markers Device and Equipment Markers Printing Systems and Software SAI Passive Blocks SAI Universal SAI ASI Cables and Connectors Unmanaged Switches Managed Switches Routers Media Converters * Terminal Blocks * Enclosures and Cable Glands * Professional Tools * Heavy Duty Connectors * * * * * * * * * * * * SteadyTEC(R) RJ45 Connectors Fiber Optic Connectors Accessories * Power Supplies and Breakers * Relays and Optos * Analog Signal Conditioning * Wireless and Ethernet Surge Protection for Low Voltage Surge Protection for Instrumentation and Control Circuit Breakers and Protectors DIN-mountable AC Receptacles (DRAC) Wireless I/O and Ethernet Wireless Gateways Wireless Transceivers Antennas and Accessories * Field Bus Couplers * Digital Input and Output Modules * Analog Input and Output Modules * Power Feed-in Modules * Temperature Modules * Functional Safety Modules Branch Rated & Supplementary Circuit Protection Branch Rated & Supplementary Circuit Protection Weidmuller's DIN-rail mounted circuit breakers are an essential part of our Electronics portfolio, with functionality that provides protection from damaging over-currents in motor and control circuits. A wide range of these products are UL 489 listed for branch circuit protection, and other devices are UL recognized as supplementary protectors, suitable for applications where branch circuit protection is already installed or not required. The narrow width of many of these products helps users to minimize the size and cost of the enclosure, and the availability of accessories such as auxiliary contacts, touch protection, lockable levers and busbar assemblies provide for a safe and dependable installation. Product Application/Standard AC Rating No. of Poles Width per pole (mm) Standard Trip Curve Comment BR Series Branch / UL489, 0.5-30A / 277/480V 1, 2 17.5 C, D Thermal-Magnetic CSA C22.2 No.5.02 1-30A / 277/480V 3 17.5 C, D 40-60A / 240V 1, 2, 3 17.5 C, D Branch / UL489, 0.5-25A / 240V 1, 2 13 KM CSA C22.2 No.5.02 1-25A / 240V 3 13 KM QL Series QY Series SU Series QZ Series GFCI Series DC Rating Branch / UL489, 0.5-60A / 80V 1 13 U2 CSA C22.2 No.5.02 1-60A / 125V 1 13 U2 5-40A / 80V 2 13 U2 5-60A / 125V 2 13 U2 Supplementary / UL1077, 0.5-60A / 277/480V 1, 2 17.5 C, D CSA C22.2 No. 235 1-60A / 277/480V 3 17.5 C, D Hydraulic-Magnetic Hydraulic-Magnetic Thermal-Magnetic Supplementary / UL1077, 1-60A / 277/480V 1 ,2 13 2 CSA C22.2 No. 235 10-60A / 277/480V 3 13 2 Hydraulic-Magnetic Supplementary / UL1077, 5-50A / 240V 2 13 2 Hydraulic-Magnetic CSA C22.2 No. 235 CB4200 Series Supplementary / UL1077, CSA C22.2 No. 235 0.05-16A / 250V 0.05-16A / 65V 1, 2 12.5 M1 Thermal-Magnetic/Push Button trip/reset CB2200 Series Supplementary / UL1077, CSA C22.2 No. 235 0.1-32A / 277/480V 0.1-32A / 65V 1, 2 12.5 M1 Thermal-Magnetic/Integral NO or NC aux contact 0.1-20A / 277/480V 0.1-20A / 65V 3 12.5 M1 9100 Series Supplementary / UL1077, 0.5-63A / 277V 0.5-50A / 50V 1 18 M1 CSA C22.2 No. 235 0.5-63A / 480V 0.5-50A / 110V 2 18 M1 3 18 M1 0.5-63A / 480V Thermal-Magnetic 3 Branch Rated Circuit Protection Branch Rated Circuit Protection Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02 compliant circuit breakers listed here assist with the complex task of selecting correct types and characteristics and offer a less bulky installation solution. Our range of miniature, moldedcase circuit breakers, in combination with our accessories for factory or on-site installation, offer enhanced control and monitoring capabilities. Installation kits include all parts and instructions to make the on-site job easy. We supply UL489/CSA C22.2 No.5-02 compliant 1, 2 and 3-poletype circuit breakers from 0.5 to 60 Ampere and with type C and D characteristics. Attachments such as neutral switches, auxiliary contacts and shunt trips are also available for this system. All accessories for modern busbar installations are available in compliance with the relevant UL standards. 4 Branch Rated Circuit Breakers Branch Rated Circuit Breakers Our range of UL489/CSA C22.2 No.5-02 branch rated circuit breakers in combination with our accessories for factory or on-site installation offer enhanced control and monitoring capabilities. Installation kits include all parts and instructions to make the on-site job easy. Single Pole - D Curve Current Ratings (amps) Description 0.5 Branch / 1P Cct Brkr / D Curve / 0.5A Single Pole - C Curve Part No. BR1D05AC Description Part No. Branch / 1P Cct Brkr / C Curve / 0.5A BR1C05AC 1 Branch / 1P Cct Brkr / D Curve / 1A BR1D1AC Branch / 1P Cct Brkr / C Curve / 1A BR1C1AC 2 Branch / 1P Cct Brkr / D Curve / 2A BR1D2AC Branch / 1P Cct Brkr / C Curve / 2A BR1C2AC 3 Branch / 1P Cct Brkr / D Curve / 3A BR1D3AC Branch / 1P Cct Brkr / C Curve / 3A BR1C3AC 5 Branch / 1P Cct Brkr / D Curve / 5A BR1D5AC Branch / 1P Cct Brkr / C Curve / 5A BR1C5AC 10 Branch / 1P Cct Brkr / D Curve / 10A BR1D10AC Branch / 1P Cct Brkr / C Curve / 10A BR1C10AC 15 Branch / 1P Cct Brkr / D Curve / 15A BR1D15AC Branch / 1P Cct Brkr / C Curve / 15A BR1C15AC 20 Branch / 1P Cct Brkr / D Curve / 20A BR1D20AC Branch / 1P Cct Brkr / C Curve / 20A BR1C20AC 25 Branch / 1P Cct Brkr / D Curve / 25A BR1D25AC Branch / 1P Cct Brkr / C Curve / 25A BR1C25AC 30 Branch / 1P Cct Brkr / D Curve / 30A BR1D30AC Branch / 1P Cct Brkr / C Curve / 30A BR1C30AC 40 Branch / 1P Cct Brkr / D Curve / 40A BR1D40AC Branch / 1P Cct Brkr / C Curve / 40A BR1C40AC 50 Branch / 1P Cct Brkr / D Curve / 50A BR1D50AC Branch / 1P Cct Brkr / C Curve / 50A BR1C50AC 60 Branch / 1P Cct Brkr / D Curve / 60A BR1D60AC Branch / 1P Cct Brkr / C Curve / 60A BR1C60AC Double Pole - D Curve Current Ratings (amps) Description 0.5 Branch / 2P Cct Brkr / D Curve / 0.5A Double Pole - C Curve Part No. BR2D05AC Description Part No. Branch / 2P Cct Brkr / C Curve / 0.5A BR2C05AC 1 Branch / 2P Cct Brkr / D Curve / 1A BR2D1AC Branch / 2P Cct Brkr / C Curve / 1A BR2C1AC 2 Branch / 2P Cct Brkr / D Curve / 2A BR2D2AC Branch / 2P Cct Brkr / C Curve / 2A BR2C2AC 5 Branch / 2P Cct Brkr / D Curve / 5A BR2D5AC Branch / 2P Cct Brkr / C Curve / 5A BR2C5AC 10 Branch / 2P Cct Brkr / D Curve / 10A BR2D10AC Branch / 2P Cct Brkr / C Curve / 10A BR2C10AC 15 Branch / 2P Cct Brkr / D Curve / 15A BR2D15AC Branch / 2P Cct Brkr / C Curve / 15A BR2C15AC 20 Branch / 2P Cct Brkr / D Curve / 20A BR2D20AC Branch / 2P Cct Brkr / C Curve / 20A BR2C20AC 25 Branch / 2P Cct Brkr / D Curve / 25A BR2D25AC Branch / 2P Cct Brkr / C Curve / 25A BR2C25AC 30 Branch / 2P Cct Brkr / D Curve / 30A BR2D30AC Branch / 2P Cct Brkr / C Curve / 30A BR2C30AC 40 Branch / 2P Cct Brkr / D Curve / 40A BR2D40AC Branch / 2P Cct Brkr / C Curve / 40A BR2C40AC 50 Branch / 2P Cct Brkr / D Curve / 50A BR2D50AC Branch / 2P Cct Brkr / C Curve / 50A BR2C50AC 60 Branch / 2P Cct Brkr / D Curve / 60A BR2D60AC Branch / 2P Cct Brkr / C Curve / 60A BR2C60AC Triple Pole - D Curve Current Ratings (amps) Description Triple Pole - C Curve Part No. Description Part No. 1 Branch / 3P Cct Brkr / D Curve / 1A BR3D1AC Branch / 3P Cct Brkr / C Curve / 1A BR3C1AC 2 Branch / 3P Cct Brkr / D Curve / 2A BR3D2AC Branch / 3P Cct Brkr / C Curve / 2A BR3C2AC 5 Branch / 3P Cct Brkr / D Curve / 5A BR3D5AC Branch / 3P Cct Brkr / C Curve / 5A BR3C5AC 10 Branch / 3P Cct Brkr / D Curve / 10A BR3D10AC Branch / 3P Cct Brkr / C Curve / 10A BR3C10AC 15 Branch / 3P Cct Brkr / D Curve / 15A BR3D15AC Branch / 3P Cct Brkr / C Curve / 15A BR3C15AC 20 Branch / 3P Cct Brkr / D Curve / 20A BR3D20AC Branch / 3P Cct Brkr / C Curve / 20A BR3C20AC 25 Branch / 3P Cct Brkr / D Curve / 25A BR3D25AC Branch / 3P Cct Brkr / C Curve / 25A BR3C25AC 30 Branch / 3P Cct Brkr / D Curve / 30A BR3D30AC Branch / 3P Cct Brkr / C Curve / 30A BR3C30AC 40 Branch / 3P Cct Brkr / D Curve / 40A BR3D40AC Branch / 3P Cct Brkr / C Curve / 40A BR3C40AC 50 Branch / 3P Cct Brkr / D Curve / 50A BR3D50AC Branch / 3P Cct Brkr / C Curve / 50A BR3C50AC 60 Branch / 3P Cct Brkr / D Curve / 60A BR3D60AC Branch / 3P Cct Brkr / C Curve / 60A BR3C60AC Note: Additional current ratings available. Contact your local Weidmuller representative. 5 Branch Rated Circuit Breakers Accessories for Branch Rated Circuit Breakers Module Type of Contact Contacts Weight g / Each Packing Unit Part No. Auxiliary contact, for mounting on the right 1/2 1 auxiliary contact 1NO 35 6 BAU10 1/2 2 auxiliary contacts 1NO + 1NC 40 6 BAU11 24 12 14 BAU11 BAU10 23 13 Standards 11 UL489 and CSA C22.2 No. 5-02 10 A /240 V AC 3 A / 110 V DC 1 A / 220 V DC Rated operating currents Minimum contact load 1 mA at 24 V DC Conductor cross sections Type of conductor *) min. Single wire 1.0 mm2 (AWG18) max. 2.5 mm2 (AWG14) Stranded wire 1.0 mm (AWG18) 1.5 mm2 (AWG16) Stranded wire with ferrule 1.0 mm2 (AWG18) 1.5 mm2 (AWG16) Torque max. 0.8 Nm (7 lb.in) 2 *) Stripped length 8 - 9 mm ( ) values in brackets = measurement units for North America Test Currents* Electromagnetic Rated Current IN A Rated Voltage V AC Not Tripping I4A Tripping I5A Weight g / Each Packing Unit Part No. Neutral switch 0.3 - 32 277/480 400 700 165 6 BNS32A 40 - 63 240 630 1000 165 6 BNS63A * additional electromagnetic protection Module Rated Operating Voltage Max. operating curent at Un (t < 10 ms) Weight g / Each Packing Unit Part No. 0.25 A at 110 V 110 5 BST110V Shunt trip, for mounting on the right or left 0.3 - 32 110 - 240 V UC, 277 V AC Lock-off/Lock-on device 6 Weight g / Each Packing Unit Part No. 2 10 LD10 Branch Rated Circuit Breakers Accessories for Branch Rated Circuit Breakers Mounting Instructions of Accessories Applies to BNS... and BST: The accessory devices BNS... and BST can be installed on the right or left. Mounting Bring the blue knobs of all devices into the "OFF" position Remove grey cover from the switching device and attachment Insert drive plate between the switching device and BNS... or BST Insert connecting pin into the knob (insertion depth approx. 7 mm) 5. Combine switching device and BNS... or BST 6. Screw the devices together (observe correct screw length) Mounting screw 34 mm (see accessories page 6) 1. 2. 3. 4. Auxiliary contact Neutral switch/ Shunt trip Switching device Neutral switch/ Shunt trip Applies to BAU... The auxiliary contact BAU... can only be installed on the right. Installation 1. 2. 3. 4. Flick the blue switches of all devices to the "OFF" position Remove the grey cover from the switching device and attachment Combine switching device and BAU... Insert connection screws and connect the two devices by turning the screws 90 5. After installation, close and open to check correct operation Applies to all switching devices BNS..., BST and BAU... The load and mains can be connected into either the top or bottom (Line/Load Reversible). Switching device Auxiliary contact Design of the terminals * Optical detection of screw position * Increased breaking resistance if the screwdriver becomes jammed * Universal connecting terminals, suitable for connecting all known cable lugs such as ring or forked cable lugs and pin terminals * Ring cable lugs can be connected by opening the flap and removing the connecting screw * Can also be used for applications that require ring cable lugs (e.g. nuclear power stations) * DIN EN 50274, VDE 0660-514 compliant protection against contact with live parts is fully guaranteed 1. Box terminal for solid conductors flexible conductors with or without cable lug 2. Screw terminal for forked cable lug 3. Screw terminal for ring cable lug (ring tongue) 7 Branch Rated Circuit Breakers Busbar and Accessories for Branch Rated Circuit Breakers (UL489/CSA C22.2 No.5-02) BTPC100 BPF35 BPF50 Criteria: * for MCBs according to UL489 * available in 1-3 phase types * addable system * Designed for a load up to 115A * suitable accessories as connection terminals and contact protection * Busbars may not be shortened Description Part No. Busbar/Branch Protection/1ph/6Poles BB106 Busbar/Branch Protection/1ph/12Poles BB112 Busbar/Branch Protection/1ph/18Poles BB118 Busbar/Branch Protection/1ph/12Poles BB206 Busbar/Branch Protection/2ph/12Poles BB212 Busbar/Branch Protection/2ph/18Poles BB218 Busbar/Branch Protection/3ph/6Poles BB306 Busbar/Branch Protection/3ph/12Poles BB312 Busbar/Branch Protection/3ph/18Poles BB318 PwrFeed Term - 35mm BPF35 PwrFeed Term - 50mm BPF50 Touch Protection 3Caps BTPC100 Mounting screw 34 mm to connect the auxiliary contact and shunt trip or neutral switch to the switching devices 8 Touch-protection caps to cover the connecting screws on the switching devices, neutral switches and shunt trips for increased touch protection Packing Unit Part No. Packing Unit 10 pieces MS34 100 pieces Part No. TPC Branch Rated Circuit Breakers Technical Data for Branch Rated Circuit Breakers (AC) C D Application Lighting Wiring protection Control circuits Business equipment Appliances Motors low inrush Transformers Power supplies Heaters Motors high inrush Reactive load Number of poles 1 - 3; 1 + N; 3 + N Standards UL489 and CSA-22.2 Nr. 5-09 Interrupting capacity 10 kA Back-up fuse 10 kA interrupting capacity none Rated voltage AC 50/60 Hz 0.3 - 32 A 277 / 480 V Rated voltage AC 50/60 Hz 40 - 63 A 240 V Rated current range Test currents Characteristic * 0.5 - 60 A 0.5 - 60 A Thermal not tripping I1 (A) > 1 h 1.05 x In 1.05 x In Thermal tripping I2 (A) < 1 h 1.35 x In 1.35 x In Electromagnetic not tripping I4 (A) > 0.1 s 5 x In 10 x In Electromagnetic tripping I5 (A) < 0.1 s 10 x In 16 x In Reference calibration temperature of the thermal tripping 40 C Influence of the ambient temperature on the thermal release: Decrease of the current values with higher ambient temperature and increase with lower temperatures of approximately 5 % per 10 C difference in temperature Frequency range of the electromagnetic trip 16 to 60 Hz With higher frequencies, the electromagnetic tripping values increase by approximately a factor of 1.1 at 100 Hz; 1.2 at 200 Hz; 1.3 at 300 Hz; 1.4 at 400 Hz; 1.5 for DC Ambient temperature -25 C to +55 C Storage temperature -40 C to +70 C Device depth according to DIN 43880 68 mm Mechanical life 10,000 switching cycles (ON / OFF) Protection cover Finger safe and safe to back of hand according to DIN EN 50274, VDE 0660-514 Degree of protection acc. EN / IEC 60529 IP20 Installation position any Mounting DIN-rail according to DIN EN 60715 35 mm Lockability The handle can be secured against manual switching in the on and off position by a lead seal Climatic resistance Humid heat constant according to DIN EN 60068-2-78 Humid heat cycle according to DIN EN 60068-2-30 Vibration resistance > 15 g according to DIN EN 60068-2-59 during a load with I1 Resistance to mechanical shocks 25 g 11 ms Approvals - BR... items cULus marking, UL file E359964, ref standards UL489 and CAN/CSA-C22.2 No. 5 (2002) Approvals - BAU..., BNS..., BST... items cULus marking, UL file E362204, ref standards UL489 and CAN/CSA-C22.2 No. 5 (2002) Approvals - BB..., BPF..., BTPC... items pending * Other switching devices in B and Z characteristics available on request Interrupting capacity acc. to IEC 60947-2, DIN EN 60947-2 Characteristic * C, D 1pole 0.5 - 60 A 240 V 15 kA 2pole / 3pole 0.5 - 60 A 415 V 15 kA 2pole / 3pole 40 - 60 A 415 V 10 kA 9 Branch Rated Circuit Breakers Technical Data for Branch Rated Circuit Breakers (AC) Dimension Diagrams in mm (in.) Conductor Cross Sections Box Terminal Bottom Box Terminal Top Type of conductor *) max. min. max. min. Single wire 35 mm2 (AWG2) 1.0 mm2 (AWG18) 25 mm2 (AWG3) 1.0 mm2 (AWG18) Multiple wire 35 mm2 (AWG2) 16 mm2 (AWG6) 25 mm2 (AWG3) 16 mm2 (AWG6) Stranded wire 25 mm (AWG3) 1.0 mm (AWG18) 16 mm (AWG6) 1.0 mm2 (AWG18) Stranded wire with ferrule 16 mm2 (AWG6) 1.0 mm2 (AWG18) 16 mm2 (AWG6) 1.0 mm2 (AWG18) 2 2 2 Busbar cable lug up to 3 mm thickness up to 1.5 mm thickness Combined, conductor and busbar or cable lug up to 35 mm2 and up to 2 mm thickness not possible Torque max. 2.5 Nm (22.2 lb.in) 1-pole *) Stripped lengths: 12 - 14 mm at the bottom, 10 - 12 mm at the top ( ) values in brackets = measurement units for North America Copper conductor with sheath insulation for 60/75 C Internal Resistance for Product Range BR Trip Characteristic Rated Current [A] C [Ohm] D [Ohm] 0.3 16.8620 16.8620 0.5 6.8540 6.0009 1.0 1.7000 1.7560 1.6 0.5870 0.5870 2.0 0.4190 0.4190 3.0 0.2020 0.2020 4.0 0.1090 0.1090 5.0 0.0654 0.0654 6.0 0.0528 0.0491 8.0 0.0278 0.0240 10 0.0216 0.0187 12 0.0084 0.0085 13 0.0084 0.0085 15/16 0.0085 0.0076 20 0.0067 0.0064 25 0.0050 0.0041 30/32 0.0032 0.0027 40 0.0025 0.0022 50 0.0019 0.0018 60 0.0018 0.0017 Curves for Branch Rated Circuit Breakers AC 1.05-1.35xl 60 40 Product Range BR N Tripping time t Minutes Minutes Tripping time t 10 4 1 1 10 10 4 4 1 1 0,4 0,4 C D D 4x10 -2 Seconds Seconds C 10 -1 4x10 -2 10 -2 4x10 -3 10 -3 Product Range BR N 10 4 10 -1 10 -2 4x10 -3 1 2 3 4 5 6 8 10 16 20 Multiple of rated current C and D characteristic AC BR models 10 1.05-1.35xl 60 40 ln = 0.5 - 10 A 40 100 10 -3 1 2 3 4 5 6 8 10 16 20 Multiple of rated current C and D characteristic AC BR models ln = 12 - 60 A 40 100 2-pole 3-pole 9926 Series Branch Circuit Breakers and Supplementary Protectors 9926 Series Branch Circuit Breakers and Supplementary Protectors Overview of 9926 Series Model QL * AC Branch-rated circuit breakers * UL489 Listed, CSA, VDE, CE conformity * 1, 2 and 3 pole units (NEW) * Ratings up to 240V/25A Model QY * DC Branch-rated circuit breakers * UL489A Listed, VDE, CE conformity * 1 and 2 pole units (NEW) * Ratings up to 125V/60A Model QZ * AC Supplementary circuit breakers * UL1077 Recognized, VDE, CE conformity, CSA * 1, 2 and 3 pole units * Ratings up to 277/480V/60A Model GFCI * AC Supplementary circuit breakers * UL1077 and UL1053 Recognized, CE conformity * 1 pole (+N) units * Ratings up to 240V/63A Weidmuller's range of industrial, DIN-rail mounted circuit breakers are part of our broad electronics portfolio, which provides isolation and protection solutions for automation control systems. Compared with traditional fused protection, these compact circuit breakers can be closely tailored to the application, in order to simplify control and minimize equipment downtime in the event of a fault. Product ratings and mechanical construction are designed to provide the high levels of reliability expected from automation and control equipment installed on capital plant, and specifications conform to recognized international standards. 9926 Series Features * For industrial AC and DC installations * Models either for branch applications cULus (UL489/ CSA C22.2 No 5.02) approvals or supplemental cURus/ UL1077 approved /CSA C22.2 No. 235. * Single and multi-pole models, with auxiliary/trip options * Trip point unaffected by ambient temperature changes * Variety of trip characteristics available, to suit equipment protected * Narrow width on mounting rail - 13mm per pole * GFCI models with standard ratings up to 240V/50A * Full set of approved accessories, such as busbars, power lugs, lock-out handles 11 9926 Series Branch Circuit Breakers and Supplementary Protectors 9926 Series Branch Circuit Breakers (AC) Circuit Breakers Hydraulic Magnetic Type 9926 Series Double Pole 9926 Series Single Pole 9926 Series Triple Pole * 1, 2 and 3 pole versions * 120/240 VAC, 50/60 Hz * Up to 25A * Just 13 mm wide, per pole * Mounts on 35mm DIN-rail * cULus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE Technical Data Type: Single Pole (up to 120 VAC Voltage 120/240 VAC, 50/0Hz Type: Double Pole (up to 240 VAC) Type: Triple Pole (up to 240 VAC) Current minimum 0.5A Current Ratings (amps) Part No. Current Ratings (amps) Part No. Current Ratings (amps) Current maximum 25A 0.5 QL-1-13-DM-KM-0.5 9926251000 0.5 QL-2-13-DM-KM-0.5 9926252000 1 QL-3(13)-DM-KM-1A 9926253001 10,000A 1 QL-1-13-DM-KM-01 9926251001 1 QL-2-13-DM-KM-01 9926252001 2 QL-3(13)-DM-KM-2A 9926253002 1500V, 50/60Hz 2 QL-1-13-DM-KM-02 9926251002 2 QL-2-13-DM-KM-02 9926252002 5 QL-3(13)-DM-KM-5A 9926253005 100 M 3 QL-1-13-DM-KM-03 9926251003 3 QL-2-13-DM-KM-03 9926252003 10 QL-3(13)-DM-KM-10A 9926253010 10000 mechanical operations 4 QL-1-13-DM-KM-04 9926251004 4 QL-2-13-DM-KM-04 9926252004 15 QL-3(13)-DM-KM-15A 9926253015 -40...+65C 5 QL-1-13-DM-KM-05 9926251005 5 QL-2-13-DM-KM-05 9926252005 20 QL-3(13)-DM-KM-20A 9926253020 6 QL-1-13-DM-KM-06 9926251006 6 QL-2-13-DM-KM-06 9926252006 25 QL-3(13)-DM-KM-25A 9926253025 7 QL-1-13-DM-KM-07 9926251007 7 QL-2-13-DM-KM-07 9926252007 8 QL-1-13-DM-KM-08 9926251008 8 QL-2-13-DM-KM-08 9926252008 10 QL-1-13-DM-KM-10 9926251010 10 QL-2-13-DM-KM-10 9926252010 13 QL-1-13-DM-KM-13 9926251013 13 QL-2-13-DM-KM-13 9926252013 15 QL-1-13-DM-KM-15 9926251015 15 QL-2-13-DM-KM-15 9926252015 16 QL-1-13-DM-KM-16 9926251016 16 QL-2-13-DM-KM-16 9926252016 20 QL-1-13-DM-KM-20 9926251020 20 QL-2-13-DM-KM-20 9926252020 25 QL-1-13-DM-KM-25 9926251025 25 QL-2-13-DM-KM-25 9926252025 Dielectric strength Insulation resistence Operating Life Operating temperature Wire size* *0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 20 in.-lb Accessories Type Part No. Bus-bar (1 pole, insulated, 1 m) 67101904 Bus-bar (2 pole, insulated, 1 m) 67101972 Bus-bar end cap, 1 pole 67101973 Bus-bar end cap, 2 pole 67101974 Power lug, straight (14 mm) 67101960 Power lug, 90 (14 mm) 67101961 Power lug, straight (32 mm) 67102480 Power lug, 90 (32 mm) 67102479 Lock-out handle 67101913 Description Dimension Diagrams in mm (in.) 74 (2.91) 66 (2.6) 17.9 (0.7) Interrupting capacity Description 13 (0.51) 26 (1.02) 92.8 (3.65) 57 (2.24) 71.4 (2.81) The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags.The part number for adhesive SchS2 is 1720600000. 28.5 (1.12) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. See Trip Curves 1, 3, 9, KM, OP - Page 26 19 (0.75) 13 (0.51) 32 (1.26) 5 (0.2) 45 (1.77) 64.8 (2.55) 12 Description Part No. 9926 Series Branch Circuit Breakers and Supplementary Protectors 9926 Series Branch Circuit Breakers (AC) Circuit Breakers with Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) * AC voltages (120/240V) * 1, 2 and 3 pole versions * cULus listed according to UL489 and C22.2 No. 5.02, CE, VDE * Factory fitted auxiliary or trip alarm - Compact 6.5mm width, per pole - Attached to right hand side of circuit breaker Technical Data Type: Single Pole Trip (up to 120 VAC) Voltage 120/240 VAC, 50/0Hz Type: Single Pole Trip (up to 120 VAC) Type: Triple Pole (up to 120 VAC) Current minimum 0.5A Current Ratings (amps) Part No. Current Ratings (amps) Part No. Current Ratings (amps) Current maximum 25A 1 QL-A-1-13-DM-KM-1 9926261001 1 QL-T-1-13-DM-KM-1 9926271001 1 QL-AT-1-13-DM-KM-1 10,000A 2 QL-A-1-13-DM-KM-2 9926261002 2 QL-T-1-13-DM-KM-2 9926271002 2 QL-AT-1-13-DM-KM-2 9926281002 1500V, 50/60Hz 5 QL-A-1-13-DM-KM-5 9926261005 5 QL-T-1-13-DM-KM-5 9926271005 5 QL-AT-1-13-DM-KM-5 9926281005 100 M 10 QL-A-1-13-DM-KM-10 9926261010 10 QL-T-1-13-DM-KM-10 9926271010 10 QL-AT-1-13-DM-KM-10 9926281010 10000 mechanical operations -40...+65C 15 QL-A-1-13-DM-KM-15 9926261015 15 QL-T-1-13-DM-KM-15 9926271015 15 QL-AT-1-13-DM-KM-15 9926281015 20 QL-A-1-13-DM-KM-20 9926261020 20 QL-T-1-13-DM-KM-20 9926271020 20 QL-AT-1-13-DM-KM-20 9926281020 25 QL-A-1-13-DM-KM-25 9926261025 25 QL-T-1-13-DM-KM-25 9926271025 25 QL-AT-1-13-DM-KM-25 9926281025 Interrupting capacity Dielectric strength Insulation resistence Operating Life Operating temperature Wire size* 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 20 in.-lb Description 9926 Series Double Pole w/ Auxiliary Contact Description 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) 9926 Series Double Pole Trip (Alarm Contact) Description Part No. 9926281001 Approval cULus listed according to UL489 and C22.2 No. 5.02, CE, VDE UL 489 listed (5A, 250 VAC; 0.5A, 80 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) IEC 60947-5-1 Approved (5A, 250 VAC; 0.5A, 110 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) Type: Double Pole Aux (up to 240 VAC) Current Ratings (amps) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type: Double Pole Combo (up to 240 VAC) Part No. Current Ratings (amps) Part No. Current Ratings (amps) 1 QL-A-2-13-DM-KM-1 9926262001 1 QL-T-2-13-DM-KM-1 9926272001 1 QL-AT-2-13-DM-KM-1 9926282001 2 QL-A-2-13-DM-KM-2 9926262002 2 QL-T-2-13-DM-KM-2 9926272002 2 QL-AT-2-13-DM-KM-2 9926282002 5 QL-A-2-13-DM-KM-5 9926262005 5 QL-T-2-13-DM-KM-5 9926272005 5 QL-AT-2-13-DM-KM-5 9926282005 10 QL-A-2-13-DM-KM-10 9926262010 10 QL-T-2-13-DM-KM-10 9926272010 10 QL-AT-2-13-DM-KM-10 9926282010 15 QL-A-2-13-DM-KM-15 9926262015 15 QL-T-2-13-DM-KM-15 9926272015 15 QL-AT-2-13-DM-KM-15 9926282015 20 QL-A-2-13-DM-KM-20 9926262020 20 QL-T-2-13-DM-KM-20 9926272020 20 QL-AT-2-13-DM-KM-20 9926282020 25 QL-A-2-13-DM-KM-25 9926262025 25 QL-T-2-13-DM-KM-25 9926272025 25 QL-AT-2-13-DM-KM-25 9926282025 Description 9926 Series Triple Pole w/ Auxiliary Contact Dimension Diagrams in mm (in.) Type: Double Pole Trip (up to 240 VAC) Description 9926 Series Triple Pole (Alarm Contact) Description 9926 Series Triple Pole (Auxiliary & Alarm Contact) Part No. 57.0 (2.24) 26.2 (1.03) 21.3 (0.84) 11(C) 32.9 (1.3) 31.3 (1.23) (N/O)16 (N/C)18 (C)15 12(N/C) 14(N/O) 21.1 (0.83) 10.7 (0.42) 2 (0.08) 0.5 (0.02) 5.5 (0.22) 7 (0.28) See Trip Curves 1, 3, 9, KM, OP - Page 26 TRIP ALARM Q. CONNECTORS 0.5 (0.02) AUX SWITCH Q. CONNECTORS 2.8 (0.11) Type: Triple Pole Aux (up to 240 VAC) Current Ratings (amps) Type: Triple Pole Trip (up to 240 VAC) Type: Triple Pole Combo (up to 240 VAC) Part No. Current Ratings (amps) Part No. Current Ratings (amps) 1 QL-A-3(13)-DM-KM-1A 9926263001 1 QL-T-3(13)-DM-KM-1A 9926273001 1 QL-AT-3(13)-DM-KM-1A 9926283001 2 QL-A-3-13-DM-KM-2A 9926263002 2 QL-T-3(13)-DM-KM-2A 9926273002 2 QL-AT-3(13)-DM-KM-2A 9926283002 5 QL-A-3-13-DM-KM-5A 9926263005 5 QL-T-3(13)-DM-KM-5A 9926273005 5 QL-AT-3(13)-DM-KM-5A 9926283005 10 QL-A-3-13-DM-KM-10A 9926263010 10 QL-T-3(13)-DM-KM-10A 9926273010 10 QL-AT-3(13)-DM-KM-10A 9926283010 15 QL-A-3-13-DM-KM-15A 9926263015 15 QL-T-3(13)-DM-KM-15A 9926273015 15 QL-AT-3(13)-DM-KM-15A 9926283015 20 QL-A-3-13-DM-KM-20A 9926263020 20 QL-T-3(13)-DM-KM-20A 9926273020 20 QL-AT-3(13)-DM-KM-20A 9926283020 25 QL-A-3-13-DM-KM-25A 9926263025 25 QL-T-3(13)-DM-KM-25A 9926273025 25 QL-AT-3(13)-DM-KM-25A 9926283025 Description Description Description Part No. 13 9926 Series Branch Circuit Breakers and Supplementary Protectors 9926 Series Branch Circuit Breakers - DC Version Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole (80 VDC) * Single and double pole versions * U2 trip curve for general purpose applications * 80 and 125 VDC * Up to 60A * Just 13 mm wide, per pole * Mounts on 35 mm DIN-rail * UL 489A listed * VDE Technical Data Type: Single Pole (80 VDC) Voltage 120/240 VAC, 50/0Hz Type: Single Pole (125 VDC) Current minimum 0.5A Current Ratings (amps) Part No. Current Ratings (amps) Current maximum 60A 0.5 QY-1-13-DM-U2-0.5 9926251900 1 QY-1-13-DM-U2-01-B1 9926251801 10,000A 1 QY-1-13-DM-U2-01 9926251901 2 QY-1-13-DM-U2-02-B1 9926251802 1500V, 50/60Hz 2 QY-1-13-DM-U2-02 9926251902 3 QY-1-13-DM-U2-03-B1 9926251803 100 M 3 QY-1-13-DM-U2-03 9926251903 4 QY-1-13-DM-U2-04-B1 9926251804 10000 mechanical operations 4 QY-1-13-DM-U2-04 9926251904 5 QY-1-13-DM-U2-05-B1 9926251805 5 QY-1-13-DM-U2-05 9926251905 10 QY-1-13-DM-U2-10-B1 9926251810 10 QY-1-13-DM-U2-10 9926251910 15 QY-1-13-DM-U2-15-B1 9926251815 15 QY-1-13-DM-U2-15 9926251915 20 QY-1-13-DM-U2-20-B1 9926251820 20 QY-1-13-DM-U2-20 9926251920 25 QY-1-13-DM-U2-25-B1 9926251825 25 QY-1-13-DM-U2-25 9926251925 30 QY-1-13-DM-U2-30-B1 9926251830 30 QY-1-13-DM-U2-30 9926251930 35 QY-1-13-DM-U2-35-B1 9926251835 35 QY-1-13-DM-U2-35 9926251935 40 QY-1-13-DM-U2-40-B1 9926251840 40 QY-1-13-DM-U2-40 9926251940 45 QY-1-13-DM-U2-45-B1 9926251845 45 QY-1-13-DM-U2-45 9926251945 50 QY-1-13-DM-U2-50-B1 9926251850 50 QY-1-13-DM-U2-50 9926251950 60 QY-1-13-DM-U2-60-B1 9926251860 60 QY-1-13-DM-U2-60 9926251960 Interrupting capacity Dielectric strength Insulation resistence Operating Life Operating temperature -40...+65C Wire size* 1-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 20 in.-lb Approval UL listed to UL489 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type Part No. Bus-bar (1 pole, insulated, 1 m) 67101904 Bus-bar end cap, 1 pole 67101973 Power lug, straight (14 mm) 67101960 Power lug, 90 (14 mm) 67101961 Power lug, straight (32 mm) 67102480 Power lug, 90 (32 mm) 67102479 Lock-out handle 67101913 See Trip Curves 1, 9, OP, U2 - Page 26 14 9926 Series Single Pole (125 VDC) Description Description Part No. 9926 Series Double Pole (125 VDC) 9926 Series Double Pole (80 VDC) Type: Double Pole (80 VDC) Type: Double Pole (125 VDC) Part No. Current Ratings (amps) 5 QY-2-13-DM-U2-5A 9926252905 5 QY-2-13-DM-U2-5A-B1 9926252805 10 QY-2-13-DM-U2-10A 9926252910 10 QY-2-13-DM-U2-10A-B1 9926252810 15 QY-2-13-DM-U2-15A 9926252915 15 QY-2-13-DM-U2-15A-B1 9926252815 16 QY-2-13-DM-U2-16A 9926252916 20 QY-2-13-DM-U2-20A-B1 9926252820 20 QY-2-13-DM-U2-20A 9926252920 30 QY-2-13-DM-U2-30A-B1 9926252830 40 QY-2-13-DM-U2-40A 9926252940 32 QY-2-13-DM-U2-32A-B1 9926252832 40 QY-2-13-DM-U2-40A-B1 9926252840 50 QY-2-13-DM-U2-50A-B1 9926252850 60 QY-2-13-DM-U2-60A-B1 9926252860 Current Ratings (amps) Description Description Part No. Supplementary Circuit Breakers Supplementary Circuit Protection Compared to traditional fuse installation, the UL1077/CSA C22.2 No.235 compliant circuit breakers listed here assist with the complex task of selecting correct types and characteristics and offer a less bulky installation solution. Our range of miniature, moldedcase circuit breakers, in combination with our accessories for factory or on-site installation, offer enhanced control and monitoring capabilities. Installation kits include all parts and instructions to make the on-site job easy. We supply UL1077/CSA C22.2 No.235 compliant 1, 2 and 3-poletype circuit breakers from 0.5 to 60 Ampere and with type C and D characteristics. Attachments such as neutral switches, auxiliary contacts and shunt trips are also available for this system. All accessories for modern busbar installations are available in compliance with the relevant UL standards. 15 Supplementary Circuit Breakers Supplementary Circuit Breakers Circuit Breakers Thermal Magnetic Type Our range of UL1077/CSA C22.2 No.235 supplementary protectors can be used where additional protection is required in control circuits. Combined with the accessories it also offers enhanced monitoring and control capabilities. Single Pole - D Curve Single Pole - C Curve Current Ratings (amps) Description Part No. Description 0.5 Suppl / 1P Cct Brkr / D Curve / 0.5A SU1D05AC Suppl / 1P Cct Brkr / C Curve / 0.5A SU1C05AC 1 Suppl / 1P Cct Brkr / D Curve / 1A SU1D1AC Suppl / 1P Cct Brkr / C Curve / 1A SU1C1AC 2 Suppl / 1P Cct Brkr / D Curve / 2A SU1D2AC Suppl / 1P Cct Brkr / C Curve / 2A SU1C2AC 3 Suppl / 1P Cct Brkr / D Curve / 3A SU1D3AC Suppl / 1P Cct Brkr / C Curve / 3A SU1C3AC 5 Suppl / 1P Cct Brkr / D Curve / 5A SU1D5AC Suppl / 1P Cct Brkr / C Curve / 5A SU1C5AC 10 Suppl / 1P Cct Brkr / D Curve / 10A SU1D10AC Suppl / 1P Cct Brkr / C Curve / 10A SU1C10AC 15 Suppl / 1P Cct Brkr / D Curve / 15A SU1D15AC Suppl / 1P Cct Brkr / C Curve / 15A SU1C15AC 20 Suppl / 1P Cct Brkr / D Curve / 20A SU1D20AC Suppl / 1P Cct Brkr / C Curve / 20A SU1C20AC 25 Suppl / 1P Cct Brkr / D Curve / 25A SU1D25AC Suppl / 1P Cct Brkr / C Curve / 25A SU1C25AC 30 Suppl / 1P Cct Brkr / D Curve / 30A SU1D30AC Suppl / 1P Cct Brkr / C Curve / 30A SU1C30AC 40 Suppl / 1P Cct Brkr / D Curve / 40A SU1D40AC Suppl / 1P Cct Brkr / C Curve / 40A SU1C40AC 50 Suppl / 1P Cct Brkr / D Curve / 50A SU1D50AC Suppl / 1P Cct Brkr / C Curve / 50A SU1C50AC 60 Suppl / 1P Cct Brkr / D Curve / 60A SU1D60AC Suppl / 1P Cct Brkr / C Curve / 60A SU1C60AC Double Pole - D Curve Current Ratings (amps) Double Pole - C Curve Description Part No. Description Part No. 0.5 Suppl / 2P Cct Brkr / D Curve / 0.5A SU2D05AC Suppl / 2P Cct Brkr / C Curve / 0.5A SU2C05AC 1 Suppl / 2P Cct Brkr / D Curve / 1A SU2D1AC Suppl / 2P Cct Brkr / C Curve / 1A SU2C1AC 2 Suppl / 2P Cct Brkr / D Curve / 2A SU2D2AC Suppl / 2P Cct Brkr / C Curve / 2A SU2C2AC 5 Suppl / 2P Cct Brkr / D Curve / 5A SU2D5AC Suppl / 2P Cct Brkr / C Curve / 5A SU2C5AC 10 Suppl / 2P Cct Brkr / D Curve / 10A SU2D10AC Suppl / 2P Cct Brkr / C Curve / 10A SU2C10AC 15 Suppl / 2P Cct Brkr / D Curve / 15A SU2D15AC Suppl / 2P Cct Brkr / C Curve / 15A SU2C15AC 20 Suppl / 2P Cct Brkr / D Curve / 20A SU2D20AC Suppl / 2P Cct Brkr / C Curve / 20A SU2C20AC 25 Suppl / 2P Cct Brkr / D Curve / 25A SU2D25AC Suppl / 2P Cct Brkr / C Curve / 25A SU2C25AC 30 Suppl / 2P Cct Brkr / D Curve / 30A SU2D30AC Suppl / 2P Cct Brkr / C Curve / 30A SU2C30AC 40 Suppl / 2P Cct Brkr / D Curve / 40A SU2D40AC Suppl / 2P Cct Brkr / C Curve / 40A SU2C40AC 50 Suppl / 2P Cct Brkr / D Curve / 50A SU2D50AC Suppl / 2P Cct Brkr / C Curve / 50A SU2C50AC 60 Suppl / 2P Cct Brkr / D Curve / 60A SU2D60AC Suppl / 2P Cct Brkr / C Curve / 60A SU2C60AC Triple Pole - D Curve Triple Pole - C Curve Current Ratings (amps) Description 1 Suppl / 3P Cct Brkr / D Curve / 1A SU3D1AC Suppl / 3P Cct Brkr / C Curve / 1A SU3C1AC 2 Suppl / 3P Cct Brkr / D Curve / 2A SU3D2AC Suppl / 3P Cct Brkr / C Curve / 2A SU3C2AC 5 Suppl / 3P Cct Brkr / D Curve / 5A SU3D5AC Suppl / 3P Cct Brkr / C Curve / 5A SU3C5AC 10 Suppl / 3P Cct Brkr / D Curve / 10A SU3D10AC Suppl / 3P Cct Brkr / C Curve / 10A SU3C10AC 15 Suppl / 3P Cct Brkr / D Curve / 15A SU3D15AC Suppl / 3P Cct Brkr / C Curve / 15A SU3C15AC 20 Suppl / 3P Cct Brkr / D Curve / 20A SU3D20AC Suppl / 3P Cct Brkr / C Curve / 20A SU3C20AC 25 Suppl / 3P Cct Brkr / D Curve / 25A SU3D25AC Suppl / 3P Cct Brkr / C Curve / 25A SU3C25AC 30 Suppl / 3P Cct Brkr / D Curve / 30A SU3D30AC Suppl / 3P Cct Brkr / C Curve / 30A SU3C30AC 40 Suppl / 3P Cct Brkr / D Curve / 40A SU3D40AC Suppl / 3P Cct Brkr / C Curve / 40A SU3C40AC 50 Suppl / 3P Cct Brkr / D Curve / 50A SU3D50AC Suppl / 3P Cct Brkr / C Curve / 50A SU3C50AC 60 Suppl / 3P Cct Brkr / D Curve / 60A SU3D60AC Suppl / 3P Cct Brkr / C Curve / 60A SU3C60AC Note: Additional current ratings available. Contact your local Weidmuller representative. 16 Part No. Part No. Description Part No. Supplementary Circuit Breakers Accessories for Supplementary Circuit Breakers Auxiliary contact Module 1/2 Type of Contact 1 auxiliary contact Contacts 1NO Weight g / Each 35 Packing Unit 10 Part No. SAU10 1/2 2 auxiliary contact 1NO + 1NC 40 10 SAU11 24 12 14 SAU11 SAU10 23 13 11 Standards Acc. to IEC 60947-5-1, DIN EN 60947-5-1, VDE 0660-200, UL508 Rated operating currents 10 A /240 V AC 3 A / 110 V DC 1 A / 220 V DC Minimum contact load 1 mA at 24 V DC Conductor cross sections Type of conductor *) Stranded wire min. 1.0 mm2 (AWG18) 1.0 mm2 (AWG18) Stranded wire with ferrule 1.0 mm2 (AWG18) Single wire Torque max. 2.5 mm2 (AWG14) 1.5 mm2 (AWG16) 1.5 mm2 (AWG16) max. 0.8 Nm (7 lb.in) *) Stripped length 8 - 9 mm Shunt trip Module 1 Rated Operating Voltage 24 V UC Max. Operating Current at Un (t < 10 ms) 0.6 A Weight g / Each 105 Packing Unit 5 1 110 - 240 V UC, 415 V AC 0.25 A at 110 V 105 5 Part No. SST24V SST110V 0.5 A at 240 V 0.58 A at 277 V Switching Devices Supplementary Protector Rated Current in A Rated Voltage Volt AC Weight g / Each Packing Unit Test Currents * Electromagnetic Not Tripping I4 A Tripping I5 A Part No. 400 700 SNS63A Neutral switch 0.5 - 60 277/480 150 5 * additional electromagnetic protection Lock-off/Lock-on device Packing Unit Weight g / Each 10 2 Part No. LD10 17 Supplementary Circuit Breakers Accessories for Supplementary Circuit Breakers Mounting Instructions of Accessories Applies to SNS63A and SAU...: The accessory devices SNS63A and SAU... can be installed on the right or left. The auxiliary contact H...UM can only be installed on the right. Mounting screw 34 mm (see accessories page 6) Mounting: 1. Flick the blue switches of all devices to the "OFF" position 2. Remove the grey cover from the switching device and attachment 3. Insert the drive plate between the switching device and SNS63A and SAU... 4. Insert the connecting pin into the switch (insertion depth approx. 7 mm) 5. Combine switching device and SNS63A and SAU... 6. Screw devices together(observe correct screw length) Neutral switch/ Shunt trip Switching device Neutral switch/ Shunt trip Auxiliary contact Applies to SAU...: The auxiliary contact SAU... can only be installed on the right. Installation: 1. 2. 3. 4. Flick the blue switches of all devices to the "OFF" position Remove the grey cover from the switching device Combine switching device and SAU... Insert connection screws and connect the two devices by turning the screws by 90 5. After installation close and open to check operation Switching device Auxiliary contact Applies to all switching devices SAU..., SNS and SST... Design of the terminals * Optical detection of screw position * Increased breaking resistance if the screwdriver becomes jammed * Universal connecting terminals, suitable for connecting all known cable lugs such as ring or forked cable lugs and pin terminals * Ring cable lugs can be connected by opening the flap and removing the connecting screw * Can also be used for applications that require ring cable lugs (e.g. nuclear power stations) * DIN EN 50274, VDE 0660-514 compliant protection against contact with live parts is fully guaranteed 1. Box terminal for solid conductors flexible conductors with or without cable lug 18 2. Screw terminal for forked cable lug 3. Screw terminal for ring cable lug (ring tongue) Supplementary Circuit Breakers Busbar and Accessories for Supplementary Circuit Breakers (UL1077/CSA C22.2 No.235) Produktbild / Product picture / Photo du produit 6 1-10 AWG Copper wire Z2 Z2 max 50Ib-in STPC 1 SPF35 2 3 Z2 SPF95 1. Z2 1-4/0 AWG Copper wire 1. 1. max 175 Ib-in 1-10 AWG Copper wire SPF50 max 50Ib-in 1. 3. 1-14 AWG Copper wire max 35Ib-in 1. 2. SECMP SPF35 General Data SPF50 SPF35 Ue f Uimp le Ue f Uimp le Infeed at the start of the busbar Infeed at the center of the busbar 1000 V AC/DC 50/60 Hz - 115 A #1-10 AWG 60C Cu Ue f Uimp le 1000V AC/DC 50/60 Hz - 115 A #1-14 AWG 75C Cu 0.56 in 0.56 in All SB models SPF95 1P 600 V AC 1000V DC 2/3P 600V AC 50/60 Hz - 18mm / 25mm 80A@40 C / 100A@30C 160A@40C / 200A@30C Ue f Uimp le 600V AC/DC 50/60 Hz - 200 A #1-4/0 AWG 75C Cu 1 in Description Part No. Busbar/Supplementary Protection/1ph/6Poles SB106 Busbar/Supplementary Protection/1ph/12Poles SB112 Busbar/Supplementary Protection/Aux/1ph/37Poles SB1A37 Busbar/Supplementary Protection/2ph/12Poles SB212 Busbar/Supplementary Protection/2ph/18Poles SB218 Busbar/Supplementary Protection/Aux/2ph/38Poles SB2A38 Busbar/Supplementary Protection/3ph/12Poles SB312 Busbar/Supplementary Protection/3ph/39Poles SB339 Busbar/Supplementary Protection/Aux/3ph/48Poles SB3A48P PwrFeed Term - 35mm SPF35 PwrFeed Term - 50mm SPF50 PwrFeed Term - 95mm SPF95 Touch Protection 5Caps STPC Endcap/1P busbars SEC1P Endcap/multi-P busbars SECMP 19 Supplementary Circuit Breakers Technical Data for Supplementary Circuit Breakers Characteristic C D Application Lighting,Control circuits Wiring protection, Business equipment Appliances Control transformers Power supplies Reactive load Number of poles 1 - 3; 1 + N; 3 + N Standards UL1077 and CSA-22.2 No.235 Interrupting capacity see data sheet for use in the USA and Canada Current limiting class 3 Max. back-up fuse see data sheet for use in the USA and Canada Rated voltage AC 277 / 480 V Test currents Rated current range 0.5 - 60 A 0.5 - 60 A Thermal not tripping I1 (A) > 1 h 1.13 x In 1.13 x In Thermal tripping I2 (A) < 1 ha 1.45 x In 1.45 x In 5 x In 10 x In 10 x In 16 x In Electromagnetic not tripping I4 (A) > 0,1 s Electromagnetic tripping I5 (A) < 0,1 s 30 C + 5 C Influence of the ambient temperature on the thermal release: Decrease of the current values with higher ambient temperature and increase with lower temperatures of approximately 5% per 10C difference in temperature 16 2/3 to 60 Hz Reference calibration temperature of the thermal tripping Frequency range of the electromagnetic trip Ambient temperature -25 C to +55 C Storage temperature -40 C to +70 C Device depth according to DIN 43880 68 mm Mechanical live 10,000 cycles (ON / OFF) Protection cover Degree of protection acc. to EN/IEC 60529 Finger safe and safe to back of hand according to DIN EN 50274/ VDE0660-514 C at 250 V AC B at 400 V AC IP20 Installation position any Mounting DIN-rail according to DIN EN 60715 35 mm Lockability Insulation group acc. to DIN/VDE 0110 Vibration resistance The handle can be secured against manual switching in the on and off position by a lead seal Humid heat constant according to DIN EN 60068-2-78 Humid heat cycle according to DIN EN 60068-2-30 > 15 g according to DIN EN 60068-2-59 during a load with I1 Resistance to mechanical shocks 25g 11ms Approvals - SU... items cRUus marking, UL file E359481, ref standards UL1077 and CSA-C22.2 No. 235 Approvals - SAU..., SNS..., SST... items UL marking, UL file E362205, ref standards UL1077 and CSA-C22.2 No. 14 Approvals - SB..., SPF..., STPC..., SEC... items pending Climatic resistance Curves for Supplementary Circuit Breakers 1.13-1.45 x l 1.13-1.45 x l N 60 40 Minutes Minutes 60 40 10 4 4 1 10 10 4 4 1 1 0.4 0,4 0,4 0.4 B C D -3 4x10 D 10 -2 -3 4x10 10 -3 10 -3 1 2 3 4 5 6 8 10 16 20 40 100 1 2 Multiple of rated current B, C and D characteristic SU models 20 C 4x10-2 -2 Seconds 10 B 10 -1 4x10-2 Seconds 10 1 10 -1 N 3 4 5 6 8 10 20 40 Multiple of rated current ln = 0.5 - 10 A B, C and D characteristic SU models ln = 12 - 60 A 100 Supplementary Circuit Breakers Technical Data for Supplementary Circuit Breakers Conductor cross sections Box Terminal Bottom Box Terminal Top Type of conductor *) max. min. max. min. Single wire 35 mm2 (AWG2) 1 mm2 (AWG18) 25 mm2 (AWG3) 1 mm2 (AWG18) Multiple wire 35 mm2 (AWG2) 16 mm2 (AWG6) 25 mm2 (AWG3) 16 mm2 (AWG6) Stranded wire 25 mm2 (AWG3) 1 mm2 (AWG18) 16 mm2 (AWG6) 1 mm2 (AWG18) Stranded wire with ferrule 16 mm2 (AWG6) 1 mm2 (AWG18) 16 mm2 (AWG6) Busbar cable lug up to 3 mm thickness 1 mm2 (AWG18) up to 1.5 mm thickness Torque max. 2.3 Nm (20 lb.in) *) Stripped length: bottom 12 - 14 mm, top 10 - 12 mm Interrupting capacity and maximum back-up fuse for use in the USA and Canada Characteristic C and D Standards UL1077 and CSA-22.2 No.235 Interrupting capacity at rated voltage Ambient temperature 40 C Number of poles Maximum rated voltage [V] Rated current [A] Interrupting capacity [kA] Maximum back-up fuse [A] 1/1+N 277 0.5 - 10 10 70 A 1/1+N 277 12 - 60 10 4 x In 2/3/3+N 480 0.5 - 10 10 70 A 2/3/3+N 480 12 - 60 10 4 x In Internal resistance for Product Range SU Trip Characteristic Rated Current [A] C [Ohm] D [Ohm] 6.0009 0.5 6.8540 1.0 1.7000 1.7560 2.0 0.4190 0.4190 3.0 0.2020 0.2020 4.0 0.1090 0.1090 5.0 0.0654 0.0654 6.0 0.0528 0.0491 8.0 0.0278 0.0240 10 0.0216 0.0187 12/13 0.0084 0.0085 15/16 0.0085 0.0076 20 0.0067 0.0064 25 0.0050 0.0041 30/32 0.0032 0.0027 40 0.0025 0.0022 50 0.0019 0.0018 60 0.0018 0.0017 Dimension Diagrams in mm (in.) 1-pole 2-pole 3-pole 21 9926 Series Supplementary Circuit Breakers Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole * AC Voltages 277/480V * Trip curve 2 for general purpose applications * UL 1077 recognized * VDE approved and CE marked * Just 13 mm wide * Mounts to 35 mm DIN-rail * Factory fitted auxiliary or trip alarm * Single, double and triple pole versions Type: Single Pole (up to 277 VAC) Ordering Data Accessories Type Part No. Bus-bar (1 pole, insulated, 1 m) 67101904 Bus-bar (2 pole, insulated, 1 m) 67101972 Bus-bar (3 pole, insulated, 1 m) 67101971 Bus-bar end cap, 1 pole 67101973 Bus-bar end cap, 2 pole or 3 pole 67101974 Power lug, straight (14 mm) 67101960 Power lug, 90 (14 mm) 67101961 Power lug, straight (32 mm) 67102480 Power lug, 90 (32 mm) 67102479 Lock-out handle 67101913 9926 Series Triple Pole Type: Double Pole (up to 480 VAC) Type: Triple Pole (up to 480 VAC) Part No. Current Ratings (amps) Part No. Current Ratings (amps) 1 QZ-1-13-D-2-01 9926251501 1 QZ-2-13-D-2-01 9926252501 10 QZ-3-13-D-2-10 9926253510 2 QZ-1-13-D-2-02 9926251502 2 QZ-2-13-D-2-02 9926252502 15 QZ-3-13-D-2-15 9926253515 3 QZ-1-13-D-2-03 9926251503 4 QZ-2-13-D-2-04 9926252504 20 QZ-3-13-D-2-20 9926253520 4 QZ-1-13-D-2-04 9926251504 5 QZ-2-13-D-2-05 9926252505 25 QZ-3-13-D-2-25 9926253525 5 QZ-1-13-D-2-05 9926251505 6 QZ-2-13-D-2-06 9926252506 30 QZ-3-13-D-2-30 9926253530 6 QZ-1-13-D-2-06 9926251506 10 QZ-2-13-D-2-10 9926252510 40 QZ-3-13-D-2-40 9926253540 8 QZ-1-13-D-2-08 9926251508 15 QZ-2-13-D-2-15 9926252515 50 QZ-3-13-D-2-50 9926253550 10 QZ-1-13-D-2-10 9926251510 20 QZ-2-13-D-2-20 9926252520 60 QZ-3-13-D-2-60 9926253560 15 QZ-1-13-D-2-15 9926251515 25 QZ-2-13-D-2-25 9926252525 20 QZ-1-13-D-2-20 9926251520 30 QZ-2-13-D-2-30 9926252530 25 QZ-1-13-D-2-25 9926251525 35 QZ-2-13-D-2-35 9926252535 35 QZ-1-13-D-2-35 9926251535 40 QZ-2-13-D-2-40 9926252540 40 QZ-1-13-D-2-40 9926251540 50 QZ-2-13-D-2-50 9926252550 50 QZ-1-13-D-2-50 9926251550 60 QZ-2-13-D-2-60 9926252560 60 QZ-1-13-D-2-60 9926251560 Current Ratings (amps) Description Technical Data Description Description Part No. Dimension Diagrams in mm (in.) 120/240 VAC, 50/0Hz 0.5A Current maximum 60A 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength 1500V, 50/60Hz 26 (1.02) 39 (1.54) 100 M 10000 mechanical operations Operating temperature 45 (1.77) Operating Life 13 (0.51) 60 (2.36) -40...+65C 92.8 (3.65) Insulation resistence 65 (2.56) 25.9 (0.94) Current minimum 22.5 (0.86) Voltage Interrupting capacity 9926 Series Double Pole Wire size* 1-15A: 14AWG min., 10AWG max. 20-25A: Torque 10AWG min. 20 in.-lb 44 (1.73) Approval UL 1077 Recognized, VDE (EN 60947-2) Approved, cURus (CSA C22.2 No. 235), CE Marked *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. cURus recognized to UL1077 and C22.2 No. 235 See Trip Curves 1, 3, 9, KM, OP - Page 26 22 5.0 (0.2) 63.8 (2.51) 73 (2.87) 13 (0.51) 13 (0.51) 9926 Series Supplementary Circuit Breakers 9926 Series Supplementary Breakers with Contacts Circuit Breakers Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) * AC Voltages 277/480V * Trip curve 2 for general purpose applications * UL 1077 recognized * VDE approved and CE marked * Just 13 mm wide * Mounts to 35 mm DIN-rail * Factory fitted auxiliary or trip alarm * Single, double and triple pole versions Technical Data Voltage Type: Single Pole Aux (up to 277 VAC) 120/240 VAC, 50/0Hz Type: Single Pole Trip (up to 277 VAC) Type: Single Pole Combo (up to 277 VAC) Current minimum 0.5A Current Ratings (amps) Part No. Current Ratings (amps) Part No. Current Ratings (amps) Current maximum 60A 1 QZ-A-1-13-D-2-01 9926261501 1 QZ-T-1-13-D-2-01 9926271501 1 QZ-AT-1-13-D-2-01 9926281501 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V 1500 V, 50/60 Hz 2 QZ-A-1-13-D-2-02 9926261502 2 QZ-T-1-13-D-2-02 9926271502 2 QZ-AT-1-13-D-2-02 9926281502 5 QZ-A-1-13-D-2-05 9926261505 5 QZ-T-1-13-D-2-05 9926271505 5 QZ-AT-1-13-D-2-05 9926281505 9926271510 9926281510 Interrupting capacity Dielectric strength Operating temperature Description Description Part No. 10 QZ-A-1-13-D-2-10 9926261510 10 QZ-T-1-13-D-2-10 10 QZ-AT-1-13-D-2-10 100 M 15 QZ-A-1-13-D-2-15 9926261515 15 QZ-T-1-13-D-2-15 9926271515 15 QZ-AT-1-13-D-2-15 9926281515 10000 mechanical operations -40...+65C 20 QZ-A-1-13-D-2-20 9926261520 20 QZ-T-1-13-D-2-20 9926271520 20 QZ-AT-1-13-D-2-20 9926281520 25 QZ-A-1-13-D-2-25 9926261525 25 QZ-T-1-13-D-2-25 9926271525 25 QZ-AT-1-13-D-2-25 9926281525 Insulation resistence Operating Life Description Wire size* 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 9926 Series Double Pole w/ Auxiliary Contact 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) 9926 Series Double Pole Trip (Alarm Contact) 20 in.-lb Approval UL 1077 Recognized, VDE (EN 60947-2) Approved, cURus (CSA C22.2 No. 235), CE Marked Type: Double Pole Aux (up to 480 VAC) UL 489 listed (5A, 250 VAC; 0.5A, 80 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) IEC 60947-5-1 Approved (5A, 250 VAC; 0.5A, 110 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) * Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags.The part number for adhesive SchS2 is 1720600000. Type: Double Pole Combo (up to 480 VAC) Type: Double Pole Trip (up to 480 VAC) Part No. Current Ratings (amps) Part No. Current Ratings (amps) 1 QZ-A-2-13-D-2-01 9926262501 1 QZ-T-2-13-D-2-01 9926272501 1 QZ-AT-2-13-D-2-01 9926282501 2 QZ-A-2-13-D-2-02 9926262502 2 QZ-T-2-13-D-2-02 9926272502 2 QZ-AT-2-13-D-2-02 9926282502 5 QZ-A-2-13-D-2-05 9926262505 5 QZ-T-2-13-D-2-05 9926272505 5 QZ-AT-2-13-D-2-05 9926282505 10 QZ-A-2-13-D-2-10 9926262510 10 QZ-T-2-13-D-2-10 9926272510 10 QZ-AT-2-13-D-2-10 9926282510 15 QZ-A-2-13-D-2-15 9926262515 15 QZ-T-2-13-D-2-15 9926272515 15 QZ-AT-2-13-D-2-15 9926282515 20 QZ-A-2-13-D-2-20 9926262520 20 QZ-T-2-13-D-2-20 9926272520 20 QZ-AT-2-13-D-2-20 9926282520 25 QZ-A-2-13-D-2-25 9926262525 25 QZ-T-2-13-D-2-25 9926272525 25 QZ-AT-2-13-D-2-25 9926282525 Current Ratings (amps) Description 9926 Series Triple Pole w/ Auxiliary Contact Description 9926 Series Triple Pole Combination (Auxiliary & Alarm Contact) 9926 Series Triple Pole Trip (Alarm Contact) Description Part No. See Trip Curves 1, 2, 3, 9, OP - Page 26 Type: Triple Pole Aux (up to 4800 VAC) Current Ratings (amps) Type: Triple Pole Trip (up to 480 VAC) Type: Triple Pole Combo (up to 480 VAC) Part No. Current Ratings (amps) Part No. Current Ratings (amps) 1 QZ-A-3-13-D-2-01 9926263501 1 QZ-T-3-13-D-2-01 9926273501 1 QZ-AT-3-13-D-2-01 9926283501 2 QZ-A-3-13-D-2-02 9926263502 2 QZ-T-3-13-D-2-02 9926273502 2 QZ-AT-3-13-D-2-02 9926283502 5 QZ-A-3-13-D-2-05 9926263505 5 QZ-T-3-13-D-2-05 9926273505 5 QZ-AT-3-13-D-2-05 9926283505 10 QZ-A-3-13-D-2-10 9926263510 10 QZ-T-3-13-D-2-10 9926273510 10 QZ-AT-3-13-D-2-10 9926283510 15 QZ-A-3-13-D-2-15 9926263515 15 QZ-T-3-13-D-2-15 9926273515 15 QZ-AT-3-13-D-2-15 9926283515 20 QZ-A-3-13-D-2-20 9926263520 20 QZ-T-3-13-D-2-20 9926273520 20 QZ-AT-3-13-D-2-20 9926283520 25 QZ-A-3-13-D-2-25 9926263525 25 QZ-T-3-13-D-2-25 9926273525 25 QZ-AT-3-13-D-2-25 9926283525 Description Description Description Part No. 23 9926 Series Supplementary Circuit Breakers Ground Fault Current Interrupt 9926 Series GFCI Ordering Data Type: Triple Pole (up to 480 VAC) Current Ratings (amps) Description 9926 Series GFCI - dimensions in mm (in.) Part No. QF17A2505 - CB W/GFI 9926291105 10 QF17A2510 - CB W/GFI 9926291110 15 QF17A2515 - CB W/GFI 9926291115 20 QF17A2520 - CB W/GFI 9926291120 25 QF17A2525 - CB W/GFI 9926291125 30 QF17A2530 - CB W/GFI 9926291130 50 QF17A2550 - CB W/GFI 9926291150 73 (2.87) 65 (2.56) Technical Data Standard Ampere Ratings (A) 57 93 (3.66) 82.4 (3.24) 5 (2.24) * CE approved * UL1077 and UL1053 recognized * Small frame size (26mm wide) * Single pole plus switched neutral ground leakage protection * Trip point is unaffected by ambient temperature * Current ratings up to 50A * Trip indication (mid trip handle position) * Trip curve 2 for general purpose applications 5 to 50A 30 (CE) / 22 (UL) Number of Poles 1+N Equipment Type Ground Leakage/GFCS @ 120 V, 5 kA @ 240 V Rated Interrupting/ Withstand Capacity (kA) 5kA -- Weight (kg) 0.26 Trip Curve (standard) Operating Temperature 68.8 (2.71) 230 (CE) / 240 (UL) 26 (1.02) 2 -40 to +65C 8.0 (0.315) 71.4 (2.81) Approval UL 1077 and UL 1053, CE 16.4 (0.646) 26 (1.02) Rated Voltage (V) 44 (1.73) 7.8 (0.307) Sensitivity (mA) See Trip Curve 2 - Page 30 35.7 (1.406) 24 9926 Series Supplementary Circuit Breakers 9926 Series Mounting Options and Accessories 93% Mounting Options 95 OFF ON OF F 95 5 N VERT 45 W ON R 5 N HO IZ DO 4 W OF F ON OF F 107% 10 5 80A max. ON Voltage 5% Technical Data Current Rating 10 % ON OF F Accessories 100% ON OFF OFF HORIZ 4 5 VERT D 4 O 100% ON UP UP It is important to note that in environments that are exposed to a high degree of vibration, the cables that connect to the circuit breaker must be securely held in place, as the breaker is not designed to carry the weight of the cables. A maximum of 35N can be applied to the terminal area, in a direction perpendicular to the mounting axis. ON OF F % % If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure 1 shows a diagram of the rating factor to apply. The published curves for these circuit breaker products are produced with the circuit breaker in the vertical mounting position. The rating factor only applies to the must hold and must trip points of the curve as the other parts (instantaneous trip point) stay largely unaffected. 500V max. Short Circuit Strength 25kA Type Part No. Bus-bar (1 pole, insulated, 1 m) 67101904 Bus-bar (2 pole, insulated, 1 m) 67101972 Bus-bar (3 pole, insulated, 1 m) 67101971 Part Number Table - Example To order 9926 Series Single Pole Circuit Breaker Part No. 9926251100 * Current Rating of 1.0 amp * Internal Resistance per Pole of 1.1 ohms * Trip Curve - M1, Medium (Standard) 9 9 2 6 2 5 1 0 0 0 Amperage Technical Data Current Rating Wire Size Dimensions 85A max. "00" - 0.5A "01" - 1A "02" - 2A 10 AWG min., 4 AWG max. "60" - 60A / A: 6 mm B: 32 mm Type Part No. Bus bar end cap,1 pole 67101973 Bus bar end cap, 2 pole or 3 pole 67101974 Trip Curves (Types 5-9) "0" - Branch AC KM (Standard) "1" - Branch AC OP (Instantaneous) "2" - Branch AC 1 (Fast) "3" - Supplemental 9 (Slow) "4" - Branch 80VDC 1 (Fast) "5" - Supplemental 2 (Standard) "6" - Branch 125VDC OP (Instantaneous) "7" - Branch 80VDC OP (Instantaneous) "8" - Branch 125VDC U2 (Standard) "9" - Branch 80VDC U2 (Standard) Poles Type Part No. Power lug, straight (14 mm) QF17A2505 - CB W/GFI Power lug, 90 (14 mm) QF17A2510 - CB W/GFI Power lug, straight (32 mm) QF17A2515 - CB W/GFI 67101960 1 Pole 2 Pole 3 Pole Type "5" - Base Breaker "6" - With Auxiliary Contact "7" - With Trip Alarm Contact "8" - Combo Aux/Trip Contact "9" - GFCI 67101961 67101980 9 9 2 6 2 4 1 0 0 0 Amperage Type Part No. "00" - 0.5A "01" - 1A "02" - 2A Lock-out handle QF17A2505 - CB W/GFI 67101913 "60" - 60A / Trip Curves (Type 4) "0" - Supplemental 1 (Slow) "1" - Supplemental 3 (Fast) "3" - Branch AC 9 (Slow) Poles 1 Pole 2 Pole 3 Pole Type "4" - Base Breaker 25 9926 Series Supplementary Circuit Breakers 9926 Series Trip Curves Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C AC version Sample trip characteristics - KM 1000 OPERATING CHARACTERISTICS MINUTES AMBIENT TEMPERATURE 30C 100 CURVE 1 10 TRIPPING TIME CURVE KM 10 10 1 SECONDS 1 0.1 125% 150% 200% 400% 600% 800% 1000% minimum 15 8 4 0.7 0.09 0.007 0.005 (sec) maximum 300 90 28 4 1.5 0.6 0.4 (sec) Although the 9926 series uses a magnetic only trip mechanism, CSA testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. Q-Frame Curve Equivalency Chart 10 2 3 9 KM U2 OP Standard QL QL QL QL UL489 QY UL489A QZ UL1077 QY QZ QZ QZ QZ D C B K QY C C Instantaneous 5000 4000 2500 3000 2000 1500 1000 500 400 300 200 5000 4000 2500 3000 2000 1500 1000 1200 500 400 300 200 100 105 130 150 QL Equivalent Curve 0.001 0.001 1 Breaker Frame QY 0.01 0.01 CBI Curve 0.1 125 150 TRIPPING TIME AMBIENT TEMPERATURE 30C 100 1 1 SECONDS OPERATING CHARACTERISTICS 100 MINUTES 1000 (%) RATED CURRENT (%) RATED CURRENT Trip Curve 1 applies to the following part numbers where "XX" is the current rating: Single Pole-- 99262512XX Double Pole-- 99262522XX 1000 CURVE 2 10 1 10 2 5 6 10 15 20 25 5000 4000 2500 3000 2000 1500 30 35 40 (%) RATED CURRENT 5000 4000 2500 3000 2000 1500 1000 500 400 300 AC DC 200 5000 4000 2500 3000 2000 1500 1000 1200 500 400 0.001 300 0.001 200 0.01 1 CURRENT RATINGS [Amps] 0.1 0.01 0.1 0.001 130 150 0.1 1 0.01 1 SECONDS 1 (%) RATED CURRENT 100 105 130 150 5000 4000 2500 3000 2000 1500 1000 1200 500 10 105 10 100 105 130 150 CURVE OP INSTANTANEOUS DC (4% RIPPLE FACTOR) 1 TRIPPING TIME TRIPPING TIME AMBIENT TEMPERATURE 30C INTERNAL IMPEDANCE [Ohms] AMBIENT TEMPERATURE 30C 10 OPERATING CHARACTERISTICS 100 MINUTES MINUTES CURVE U2 DC (4% RIPPLE FACTOR) 1 SECONDS 400 1000 OPERATING CHARACTERISTICS 10 (%) RATED CURRENT (%) RATED CURRENT (%) RATED CURRENT 100 300 200 100 105 130 150 5000 4000 2500 3000 2000 1500 1000 1200 500 0.001 400 0.001 300 0.001 200 0.01 100 105 130 150 0.01 1000 1200 0.1 500 0.1 0.01 1000 26 10 400 0.1 TRIPPING TIME 1 SECONDS SECONDS 1 10 SECONDS 10 CURVE 3 10 1 1 TRIPPING TIME TRIPPING TIME 1 AMBIENT TEMPERATURE 30C 100 300 CURVE 9 10 AMBIENT TEMPERATURE 30C 100 OPERATING CHARACTERISTICS 200 AMBIENT TEMPERATURE 30C MINUTES MINUTES 100 1000 OPERATING CHARACTERISTICS OPERATING CHARACTERISTICS MINUTES 1000 Additional trip curves and amp ratings are available upon request. 50 CB4200 Series Supplementary Circuit Breakers Circuit Breakers Thermal Magnetic Type CB4200 Series Single Pole CB4200 Series Double Pole * * * * * Rated from 0.05 to 16.0 amps Available in single or double pole configurations Features a tease free design to reduce contact damage Offers push button trip/reset function Trip free design means the breaker cannot be held closed against a fault * Mounts on 32mm* or 35mm DIN-rail * UL 1077 recognized * CSA C22.2 No. 235 Ordering Data Type: Single Pole Current Ratings (amps) 0.05 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1.2 1.3 1.4 1.5 1.8 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 Part No. TS 35 *For TS 32 Rail, see adapter below 9124083500 9124653500 9104173500 9104183500 9129813500 9124093500 9101003500 9124113500 9129563500 9101103500 9101203500 9101303500 9124123500 9124133500 9101403500 9124143500 9101503500 9101603500 9101703500 9124163500 9104353500 9124173500 9101803500 9107833500 9103813500 9120043500 9104153500 9103003500 9104613500 9101903500 9124183500 9107843500 9124193500 9107853500 9102003500 9124213500 Type: Double Pole Current Ratings (amps) 0.05 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1.2 1.3 1.4 1.5 1.8 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 Part No. TS 35 *For TS 32 Rail, see adapter below 9124223500 9124233500 9120353500 9124243500 9124263500 9124273500 9129583500 9124283500 9124293500 9129593500 9129613500 9129623500 9124313500 9124323500 9129633500 9124333500 9129643500 9129653500 9129663500 9124343500 9129713500 9124353500 9129673500 9124363500 9124373500 9124383500 9124393500 9104673500 9124423500 9129683500 9124433500 9124443500 9124453500 9124463500 9129693500 9124473500 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23C CB4200 Series *Adapter foot - dimensions in mm (in.) 0.05 to 7.5 A 100 100 Trip time in seconds 1,000 Trip time in seconds 1,000 10 1 TS32 adapter 0.01 0.01 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 9102100000 1 0.1 0.8 1 -30C +23C +55C 10 0.1 0.001 8 to 16 A 20 -30C +23C +55C M1+ 10,000 (.787) M1+ 10,000 0.001 0.8 1 2 3 4 6 8 10 20 30 50 70 100 ... times rated current 27 CB4200 Series Supplementary Circuit Breakers CB4200 Series Double Pole CB4200 Series Single Pole Internal Wiring Diagram Internal Wiring Diagram Dimensions in mm Technical Data Rated voltage & current Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) UL CSA VDE Interrupting capacity; 4201 (UL 1077/EN 60934 PC1) Typical life at 2 x rated current Shock Torque Vibration Temperature range Corrosion Humidity Weight Wire size (UL) Accessories Jumpers Daisy Chain 50* Straight CQB** insulated Angled CQB** insulated Adapter foot (for TS 32 Rail) Busbar Busbar end cap for 6720000227 Power lug for 6720000227 Type BDC 50 CQB 2 CQB 3 CQB 4 CQB 10 CQB 2 CQB 3 CQB 4 CQB 10 MCBAF/TS 32 Single pole 1 meter Part No. 9970290000 9970560000 9970570000 9970580000 9970590000 9970600000 9970610000 9970620000 9970630000 9102100000 6720000227 6720000225 6720000226 28 Note: Resistive and inductive loads (0.05 - 16 A) *BDC will accommodate 20 A per pin, 20 A total **CQB will accommodate 18 A per pin, 18 A total; dedicated to 4201 Series ***Please specify horizontal or vertical print when ordering. Standard quantity = 144 tags per card. Marking Tags Note: Part numbers are shown for a single card of pre-printed tags numbered 1-50. Dimensions in mm Voltage Ratings Current Ratings AC 250 V, DC 65 V, 50/60 Hz 0.05...16 A AC 250 V, DC 65 V, 50/60 Hz 0.05...16 A AC 250 V, DC 65 V, 50/60 Hz 0.05...16 A PTI 600 to IEC 112 4,000 VAC; IEC 664 & 664 A > 100 MM (DC 500 V) 4201-10 Maximum capacity 0.05...0.8 A Self-limiting 1...2 A 200 A 2.5...16 A 400 A Rated current Rated voltage Maximum capacity 0.05...2.0 A AC 250 V 200 A 2.0...16 A AC 250 V 200 A 20 A AC 125 V 400 A 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea 1.2 Nm 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30C...+55C (-22F...+131F) 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca 60 g per pole #20...8 AWG solid/0.5...6 mm2 Special print only Consecutive horizontal Consecutive vertical WS 8/5 MC DEK 5/5 DEK 5/5 1640750000*** 0473460001 0473560001 CB2200 Series Supplementary Circuit Breakers CB2211-10 Single Pole Circuit Breakers Thermal MagneticType CB2212-10 Double Pole CB2213-10 Triple Pole * Rated from 0.1 to 32.0 amps * Available in single, double and triple pole configurations * Offers normally open (N/O) and normally closed (N/C) auxiliary contacts * Lever-switch trip/reset function * Mounts on 32mm or 35mm DIN-rail * UL 1077 recognized * CSA C22.2 No. 235 Ordering Data Type: Single Pole - CB2211-10 Internal Resistance per Pole (ohms) (M1) 92 26.1 11.6 6.6 4.1 3 1.65 1.1 0.47 0.28 0.183 0.124 0.077 0.063 0.045 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 Current Ratings (amps) 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 32 Type: Double Pole - CBB2212-10 Type: Triple Pole - CBB2213-10 N/O Aux. Part No. N/C Aux. Part No. Current Ratings (amps) N/O Aux. Part No. Current Ratings (amps) N/O Aux. Part No. N/C Aux. Part No. 9911010000 9911020000 9911030000 9911040000 9911050000 9911060000 9911080000 9911100000 9911150000 9911200000 9911250000 9911300000 9911400000 9911500000 9911600000 9911800000 9921100000 9921200000 9921500000 9921600000 9921800000 9921200000 9921250000 9921320000 9911010005 9911020005 9911030005 9911040005 9911050005 9911060005 9911080005 9911100005 9911150005 9911200005 9911250005 9911300005 9911400005 9911500005 9911600005 9911800005 9921100005 9921200005 9921500005 9921600005 9921800005 9921200005 9921250005 9921320005 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 32 9912010000 9912020000 9912030000 9912040000 9912050000 9912060000 9912070000 9912080000 9912100000 9912200000 9912250000 9912300000 9912400000 9912500000 9912600000 9912800000 9922100000 9922120000 9922150000 9922160000 9922180000 9922200000 9922250000 9922320000 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 32 9913010000 9913020000 9913030000 9913040000 9913050000 9913060000 9913080000 9913100000 9913150000 9913200000 9913250000 9913300000 9913400000 9913500000 9913600000 9913800000 9923100000 9923120000 9923150000 9923160000 9923180000 9921320000 9923250000 9923320000 9913010003 9913020003 9913030003 9913040003 9913050003 9913060003 9913080003 9913100003 9913150003 9913200003 9913250003 9913300003 9913400003 9913500003 9913600003 9913800003 9923100003 9923120003 9923150003 9923160003 9923180003 9921320003 Part Number Table - Example To order CB2212-10 Double Pole Circuit Breaker with N/O Aux., Part No. 9912100003 * Current Rating of 1.0 amps * Internal Resistance per Pole of 1.1 ohms * Trip Curve - M1, Medium (Standard) * N/C - N/O Auxiliary Contacts 9 9 1 2 1 0 0 0 0 3 Auxiliary Contacts "00" - N/C Auxiliary Contact "02" - W/O Auxiliary Contact "03" - N/C - N/O Auxiliary Contacts (double and triple pole only) "05" - N/O Auxiliary Contact Trip Curves (Type 4) "00" - M1, Medium (standard) "11" - F1, Fast (DC only) "12" - M3, Low Resistance "13" - T1, Delayed Base Part No. (indicates number of poles) Auxiliary for the 2-pole will be configured: N/C for 1st pole & N/O for 2nd pole. Auxiliary for the 3-pole will be configured: N/C for 1st pole & N/O for the 3rd pole. *Standard breakers will be calibrated to a M1 trip curve with N/O Auxiliary Contacts. N/C Aux. Part No. 9912010003 9912020003 9912030003 9912040003 9912050003 9912060003 9912070003 9912080003 9912100003 9912200003 9912250003 9912300003 9912400003 9912500003 9912600003 9912800003 9922100003 9922120003 9922150003 9922160003 9922180003 9922200003 Standard Current Ratings and Typical Internal Resistance Values Internal Resistance (ohms) Current Ratings (amps) 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10 12 16 20 25 32 F1 fast acting for DC M1 standard delay for AC & DC T1 delayed for AC 162 39.3 17.5 9.2 6.8 4.2 2.8 1.6 0.78 0.42 0.26 0.8 0.12 0.092 0.054 0.025 0.022 0.02 0.02 ---- 92 26.1 11.6 6.6 4.1 3 1.6 1.10 0.47 0.28 0.183 0.124 0.077 0.063 0.045 0.02 0.02 0.02 0.02 0.02 0.02 0.02 81 24.2 10.4 6.0 3.9 2.7 1.53 0.98 0.42 0.24 0.17 0.12 0.073 0.055 0.039 0.02 0.02 0.02 0.02 0.02 0.02 0.02 M3 T2 low resistance thermal for standard delay for AC & DC AC & DC 42 11.7 5.6 2.9 1.75 1.42 0.75 0.5 0.22 0.136 0.083 0.057 0.041 0.032 0.021 0.02 0.02 0.02 0.02 ---- 77 23 10.2 5.7 3.7 2.6 1.39 0.9 0.36 0.19 0.141 0.091 0.051 0.040 0.027 0.02 0.02 0.02 0.02 0.02 0.02 0.02 29 CB2200 Series Supplementary Circuit Breakers CB2200 Series Trip Curves--Thermal Magnetic Type Typical time/current characteristics at 23C CB2200 Series F1 0.1 to 32 A 10,000 -30C +23C +55C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -M1 0.1 to 7.5 A 10,000 -30C AC +23C DC +23C +55C 1,000 Interrupting capacity (UL 1077/EN 60934 PC1) Rated current 0.1...16 A 20...32 A 0.1...32 A Typical life at 2 x rated current Shock Torque Vibration Temperature range Corrosion Humidity Weight Wire size (UL) 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea 0.6 (5.3) Auxiliary contact: 0.5 (4.4) 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30...+60C (-22F...+140F) 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole max 1.5 mm2...14 AWG (Aux. contact) max 6 mm2...8 AWG Nm (lb. in.) Rated voltage 277 / 480 VAC 277 / 480 VAC 65 VDC Max. rupture capacity (3 times) 5000 A 2000 A 2000 A Type Part No. Accessories BDC 50, 20 A maximum 9970290000 Jumpers Daisy Chain 50 1 pole (CB2200) 9986510000 Busbars 2 pole (CB2200) 9987360000 100 10 10 T Voltage Ratings Current Ratings 277 / 480 VAC (50/60 Hz); 65 VDC 0.1...32 A 277 / 480 VAC (50/60 Hz); 65 VDC 0.1...32 A 250 / 415 VAC / 65 VDC 0.1...32 A 250 VAC / 65 VDC, 1 A PTI 600 to IEC 112 3,000 VAC; IEC 664 & 664 A > 100 M (DC 500 V) Rated current Rated voltage Rupture capacity (3 times) 0.05...0.8 A 250 / 415 VAC 400 A 6...32 A 250 / 415 VAC 800 A DC 0.1 AC 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -M1 8 to 32 A 10,000 -30C AC +23C DC +23C +55C 1,000 Trip time in seconds UL CSA VDE 100 10 DC 0.1 AC 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -T1 0.1 to 7.5 A 10,000 -30C +23C +55C 1,000 Trip time in seconds Technical Data Rated voltage & current Auxiliary contacts Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) Trip time in seconds Dimensions in mm 100 10 0.1 0.01 1 2 3 4 5 6 Special print only Consecutive horizontal Consecutive vertical Note: Part numbers shown are for a single card of pre-printed tags numbered 1-50. Note: Resistive and inductive loads (0.05 - 16 A) *Please specify horizontal or vertical print when ordering. Type DEK 5/6 DEK 5/6 DEK 5/6 Part No. 0490360000* 0468660001 0468760001 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -T1 8 to 32 A 10,000 -30C +23C +55C 1,000 Trip time in seconds Marking Tags 100 10 1 0.1 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 ...times rated current 30 50 70 100 CB9100 Series Supplementary Circuit Breakers Circuit Breakers Thermal Magnetic Type CB9100 Series Single Pole CB9100 Series Double Pole CB9100 Series Triple Pole Type: Double Pole Current Ratings (amps) Part No. 0.5 9925650000 1.0 9925660000 2.0 9925680000 3.0 9925690000 4.0 9925700000 6.0 9925710000 10.0 9925730000 13.0 9929830000 16 9925740000 20 9925750000 25 9925760000 32 9925770000 40 9925780000 50 9925790000 63 9925800000 Type: Triple Pole Current Ratings (amps) 0.5 1.0 2.0 3.0 4.0 6.0 10.0 13.0 16 20 25 32 40 50 63 * Rated from 0.5 to 63 amps * Available in single, double and triple pole configurations * Optional auxiliary contacts * Mounts on 35mm DIN-rail * UL and CSA approvals * CSA 277 VAC (1 pole) or 480 VAC (2 and 3 pole) * 50 VDC (0.5 A to 50 A) 1 pole * 110 VDC (0.5 A to 50 A) 2 pole Ordering Data Type: Single Pole Current Ratings (amps) Part No. 0.5 9925350000 1.0 9925360000 2.0 9925380000 3.0 9925390000 4.0 9925400000 6.0 9925410000 10.0 9925430000 13.0 9929820000 16 9925440000 20 9925450000 25 9925460000 32 9925470000 40 9925480000 50 9925490000 63 9925500000 Part No. 9925810000 9925820000 9925840000 9925850000 9925860000 9925870000 9925890000 9929840000 9925900000 9925910000 9925920000 9925930000 9925940000 9925950000 9925960000 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23C CB9100 Series M1 0.5 to 6 A 10,000 M1 M1 AC 10 to 40 A 23C 23C 23C 100 100 100 1 Trip time in seconds 1,000 Trip time in seconds 1,000 Trip time in seconds 1,000 10 10 1 10 1 0.1 0.1 0.1 0.01 0.01 0.01 0.001 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 AC 63 A 10,000 10,000 0.001 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 0.001 0.8 1 2 3 4 6 8 10 20 30 50 70 100 ... times rated current 31 CB9100 Series Supplementary Circuit Breakers CB9100 Series 70 45 18 54 44 36 59 1 pole 2 pole 6 3 pole 86 Dimensions in mm Internal Wiring Diagram Auxiliary Contact Modules Technical Data Rated voltage & current UL 1077 CSA C 22.2 No. 235 VDE Creepage resistance Insulation resistance Interrupting capacity (UL 1077/EN 609334 PC1) 1 pole Mechanical/Electrical endurance Shock Torque Vibration Temperature range - operating Weight Strip length Auxiliary contact rating Wire size - #22...12 AWG Wire size Accessories Jumpers Auxiliary contacts SPDT Security hardware 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) 91.4 80.6 PTI 250 to IEC 112 >100 M at 500 VDC Current ratings Interrupting Rupture capacity (3X) 0.5...63 A 10,000 A (UL) 0.5...32 A 2,000 A (UL) 0.5...63 A 6,000 A (UL) 0.5...50 A 6,000 A (UL) 20,000/10,000 20 g (10 ms) 2 Nm 3 g (10 to 55 Hz) -25C...+55C (-13F to 131F) 1 pole (130 g); 2 pole (280 g); 3 pole (430 g) 12 mm Voltage Current AC 220/240 5A AC 277 3A DC 24 V 4A DC 60 V 1A DC220 V 0.4 A #18...2 AWG (line); #18...3 AWG (load) 5.8 Voltage 277 VAC/50 VDC 277 / 480 AC 50 VDC (1) pole 110 VDC (2) poles Current Type Side/Middle 3 pole bus, 10 x 1010 mm, buses (19) 3 phase groupings 80A/100A 3 pole bus, 16 x 210 mm, buses (4) 3 phase groupings 120A/130A 3 pole bus, 16 x 1010 mm, buses (19) 3 phase groupings 120A/130A 1 pole bus, 12 x 210 mm, buses 12 breakers 80A/100A 1 pole bus, 12 x 210 mm (insulated), buses 12 breakers 63A Bus bar clamp 130A Auxiliary contacts Lock out cover 44 45.2 9 Internal Auxiliary Wiring Diagram Part No. 9970330000 9970340000 9970350000 9970360000 9991990000 9970370000 9970300000 9970380000 Marking Tags Adhesive label 32 ETO 10/26, yellow (26 mm x 10 mm) 5 69 1686401687 14 12 11 44 Electronic Circuit Protection Electronic Circuit Protection ESX10-T Electronic circuit protection type ESX10-T is designed to ensure selective disconnection of 24VDC load systems. 24VDC power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. Through selective disconnection the ESX10-T responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX10-T limits the highest possible current to 1.3 to 1.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 20,000 F, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX10-T can be selected in fixed values from 0.5 A... 12 A. Failure and status indication are provided by a multicolor LED and an integral short-circuit-proof status output or a relay signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation and reset of individual load circuits. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. The load circuit can be re-activated via the remote electronic reset input, control input or manually by means of the ON/OFF button. Features * Selective load protection, electronic trip characteristics * Active current limitation for safe connection of capacitive loads up to 20,000 F and on overload/ short circuit * Current ratings 0.5 A...12 A * Reliable overload disconnection with 1.1 x In plus, even with long load lines or small cable cross sections (see table 4) * Manual ON/OFF button (S1) * Control input IN+ for remote ON/OFF signal (option) * Electronic reset input RE (option) * Clear status and failure indication through LED, status output SF or Si contact F * Integral fail-safe element adjusted to current rating * Width per unit only 12.5 mm * Rail mounting * Ease of wiring through busbar LINE+ and 0 V as well as signal bars and bridges * Hazardous area approved- Class 1 Div 2, Zone 2m ATEX Zone Z 33 Electronic Circuit Protection ESX10-T Approvals Technical Data Authority Voltage rating UL2367 (E306740) 24VDC UL1604 (E322549) (class 1, div. 2, group 24VDC A, B, C, D) UL508/ cUL 508 24VDC 24VDC CSA file 165971: CSA C22.2 No: 213 (class I, div. 2) Groups A, B, C, D, T5 CSA C22.2 No: 142 24VDC Class 2 Meets requirements for Class 2 current limitation (ESX10-T... 0.5 A / 1 A / 2 A / 3 A Technical Data Current ratings 0.5...12 A 0.5...12 A 0.5...12 A 0.5...12 A 0.5...12 A (Tambient = 40C, operating voltage Ub = 24VDC) Operating data Operating voltage Ub Current rating In Closed current I0 Status indication by means of 24VDC (18...32 V) fixed current ratings: 0.5, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A ON condition: typically 20...30 mA depending on signal output * multicolor LED: GREEN: - unit is ON, power-MOSFET - is switched on - status output SF ON, - supplies + 24VDC ORANGE: in the event of overload or short circuit until electronic disconnection RED: - unit electronically disconnected - load circuit/Power-MOSFET OFF OFF: - manually switched off - (S1 = OFF) - or device is dead - undervoltage (Ub < 8 V) - after switch-on till the end - of the delay period * status output SF (option) * potential-free signal contact F (option) * ON/OFF/ condition of switch S1 Load circuit Load output Overload disconnection Short-circuit current IK Trip time for electronic disconnection Temperature disconnection Low voltage monitoring load output Starting delay tstart Disconnection of load circuit Free-wheeling circuit Several load outputs must not be connected in parallel 34 Power-MOSFET switching output (high side switch) typically 1.1 x In (1.05...1.35 x In) active current limitation (see table 1) see time/current characteristics typically 3 s at ILoad > 1.1 x In typically 3 s...100 ms at ILoad > 1.8 x In (or 1.5 x In/1.3 x In) internal temperature monitoring with electronic disconnection with hysteresis, no reset required load "OFF" at Ub < 8 V typically 0.5 sec after every switch-on and after applying Ub electronic disconnection external free-wheeling diode recommended with inductive load (Tambient = 40C, operating voltage Ub = 24VDC) ESX10-TB-114/-124/ plus-switching signal output, nominal data: 24VDC / max. 0.2 A (short circuit proof) status output is internally connected to GND with a 10 kOhm resistor Status OUT ESX10-TB-114/-124 (signal status OUT), at Ub = +24 V +24 V = S1 is ON, load output connected through 0V = S1 is ON, load output blocked and/or switch S1 is OFF ESX10-TB127 reverse red LED lit OFF condition 0 V level at status output when: * switch S1 is in ON position, but device is still * in switch-on delay * switch S1 is OFF, or control signal OFF, * device is switched off * no operating voltage Ub Signal output F ESX10-TB-101/-102 Electrical data potential-free signal contact max. 30VDC/0.5 A, min. 10 V/10 mA ON condition LED green voltage Ub applied, switch S1 is in ON position no overload, no short circuit OFF condition LED off * device switched off (switch S1 is in OFF position) * no voltage Ub applied Fault condition LED orange overload condition > 1.1 x In up to electronic disconnection Fault condition LED red electronic disconnection upon overload or short circuit device switched off with control signal (switch S1 is in ON position) ESX10-TB-101 single signal, make contact contact SC/SO-SI open ESX10-TB-102 single signal, break contact contact SC/SO-SI closed Fault signal output fault conditions: * no operating voltage Ub * ON/OFF switch S1 is in OFF position * red LED lighted * (electronic disconnection) Reset input RE ESX10-TB-124 Electrical data voltage: max. +32VDC high > 8VDC 32VDC low 3VDC > 0 V power consumption typically 2.6 mA (+24VDC) min. pulse duration typically 10 ms Reset signal RE The electronically blocked ESX10-TB-124 (terminal 22) may remotely be reset via an external momentary switch due to the falling edge of a +24 V pulse. A common reset signal can be applied to several devices simultaneously. Switched on devices remain unaffected. Control input IN+ ESX10-TB-114 Control signal IN+ see reset input RE (terminal 21) +24V level (HIGH): device will be switched on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal Switch S1 ON/OFF unit can only be switched on with S1 if a HIGH level is applied to IN+ Status output SF Electrical data Electronic Circuit Protection ESX10-T Technical Data (Tambient = 40C, operating voltage Ub = 24VDC) General data Fail-safe element: backup fuse for ESX10-T not required because of the integral redundant fail-safe element LINE+ / LOAD+ / 0V M4 Terminals screw terminals max. cable cross section flexible with wire end ferrule w/wo plastic sleeve multi-lead connection (2 identical cables) rigid/flexible flexible with wire end ferrule without plastic sleeve flexible with TWIN wire end ferrule with plastic sleeve wire stripping length tightening torque (EN 60934) Terminals screw terminals max. cable cross section flexible with wire end ferrule w/wo plastic sleeve wire stripping length tightening torque (EN 60934) Housing material 20-6 AWG (0.5 - 10 mm2) 20-11 AWG (0.5 - 4 mm2) 20-13 AWG (0.5 - 2.5 mm2) 20-9 AWG (0.5 - 6 mm2) 10 mm 1.2 Nm aux. contacts M3 23-13 AWG (0.25 - 2.5 mm2) 8 mm 0.5 Nm moulded Table 1: Voltage drop, current limitation, max. load current current rating In 0.5 A 1A 2A 3A 4A 6A 8A 10 A 12 A typically voltage drop Uon at 70 mV 80 mV 130 mV 80 mV 100 mV 130 mV 120 mV 150 mV 180 mV active current max. load current at 100% ON duty limitation (typically) Tu = 40 C Tu = 50 C 1.8 x In 0.5 A 0.5 A 1.8 x In 1 A 1A 1.8 x In 2 A 2A 1.8 x In 3 A 3A 1.8 x In 4 A 4A 1.8 x In 6 A 5A 1.5 x In 8 A 7A 1.5 x In 10 A 9A 1.3 x In 12 A 10.8 A Attention: when mounted side-by-side without convection the ESX10-T should not carry more than 80% of its rated load with 100% ON duty due to thermal effects. Mounting Ambient temperature Storage temperature Humidity symmetrical rail to EN 50022-35x7.5 0...+50 C (without condensation, see EN 60204-1) -20...+70 C 96 hrs/95 % RH/40 C to IEC 60068-2-78-Cab climate class 3K3 to EN 60721 3 g, test to IEC 68-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050 emission: EN 61000-6-3 susceptibility: EN 61000-6-2 0.5 kV/2 pollution degree 2 re-inforced insulation in operating area max. 32VDC (load circuit) Vibration Degree of protection EMC (EMC directive, CE logo) Insulation co-ordination (IEC 60934) dielectric strength Insulation resistance (OFF condition) Approvals n/a, only electronic disconnection UL2367, File E306740, Solid State Overcurrent Protectors UL1604 (class I, div. 2, zone 2), UL508, CE logo CSA C22.2 No. 142 - file 165971, C22.2 No. 213 - file 165971, C1D2 Groups A, B, C, D, Temp Code T5; Ambient 0-40C 12.5 x 80 x 83 mm approx. 65 g Dimensions (W x H x D) Mass Please note: * The user should ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the ESX10-T used. * Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the ESX10-T. * Refer to UL/CSA file for proper wiring and installation techniques. Table 2: Specifications Protection CE logo UL to EN6052 housing IP30, terminals IP00 to 2004/108/EG and 94/9/EG UL2367, File No E306740 UL508, File No E322549 UL 1604, File No E320024 CSA C22.2 No 14, File No 165971 (LR16186) CSA C22.2 No 142, File No 165971 (LR16186) CSA C22.2 No 213, File No 165971 (LR16186) IEC/EN60079-0 /-14/-15 II 3G Ex nA II B T4 Gc X CSA ATEX Table 3: ESX10-T - Ordering Information Version Signal input Signal output Signal contact Status output without Control input Remote without single signal single signal without Status OUT Status OUT Signal ON/OFF Reset Reset Signal N/O N/C Signal Positive 24V OV = OK Input Output (normally open NO) (normally closed NC) Output = OK ESX10-TA-100 xx x ESX10-TB-101 x x x ESX10-TB-102 x x x ESX10-TB-114 x x ESX10-TB-124 x x x ESX10-TB-127 x x x ESX10-TA-100 Circuit Current Protection Rating V DC R Number ampsVSPC 1CL 5Part 0.5 1 2 3 4 6 8 10 12 6720005305 6720005301 6720005302 6720005303 6720005304 6720005306 6720005308 6720005310 6720005312 ESX10-TB-101 Current Rating amps 0.5 1 2 3 4 6 8 10 12 Circuit Protection Part Number 6720005320 6720005321 6720005322 6720005323 6720005324 6720005326 6720005328 6720005330 6720005332 ESX10-TB-102 Current Rating amps 0.5 1 2 3 4 6 8 10 12 Circuit Protection Part Number 6720005340 6720005341 6720005342 6720005343 6720005344 6720005346 6720005348 6720005350 6720005352 ESX10-TB-114* Current Rating amps 0.5 1 2 3 4 6 8 10 12 Circuit Protection Part Number 6720005360 6720005361 6720005362 6720005363 6720005364 6720005366 6720005368 6720005370 6720005372 ESX10-TB-124** Current Rating amps 0.5 1 2 3 4 6 8 10 12 Circuit Protection Part Number 6720005380 6720005381 6720005382 6720005383 6720005384 6720005386 6720005388 6720005390 6720005392 ESX10-TB-127 Current Rating amps 0.5 1 2 3 4 6 8 10 12 Circuit Protection Part Number 6720005309 6720005319 6720005329 6720005339 6720005349 6720005369 6720005389 6720005399 6720005313 35 Electronic Circuit Protection ESX10-T ESX10-T Signal inputs / outputs (wiring diagram) ESX10-TA-100 ESX10-TB-101 ESX10-TB-102 ESX10-TB-114 without signal input/output without signal input with signal output F (single signal, N/O ) without signal input with signal output F (single signal, N/C) with control input IN+ (+24VDC) with status output SF (+24 V = load output ON) 1 LINE+ LOAD+ 2 LINE+ 12 SF 23 13 11 IN 21 LOAD+ 0V 3 2 3 operating condition: 13-14 closed fault condition: 13-14 open ESX10-TB-127 with reset input RE (+24VDC) with status output SF (+24 V = load output ON) with reset input RE (+DC 24 V) with inverse status output SF (0 V = load output ON) 1 SF 23 LOAD+ 2 LOAD+ 0V 3 0V 1 3 operating condition: SF +24 V = O K fault condition: SF 0 V operating condition: 11-12 open fault condition: 11-12 closed Dimensions ESX10-TB-124 LINE+ LINE+ 1 LINE+ 14 2 0V 1 LINE+ 1 12.5 .492 83 3.27 LINE LINE LOAD LOAD SF 23 RE 22 80 3.15 RE 22 2 LOAD+ 0V 2 3 operating condition: SF +24 V = O fault condition: SF 0 V LOAD+ 0V 80 3.15 3 operating condition: S F 0 V = O K fault condition: S F +24 V label snap-on socket for symmetrical rail EN 50022-35x7.5 mm This is a metric design and millimeter dimensions take precedence ( inch ) 36 Electronic Circuit Protection ESX10-T Time/Current characteristic curve (Ta = 25 C) * The trip time is typically 3 s in the range between 1.1 and 1.8 x In*1). * Electronic current limitation occurs at typically 1.8 x In*1) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x In*1) times the current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit). * Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit. disconnection typically 1.1 x I n 1.8 x I n *1) 10000 1000 trip time in seconds 100 current limitation *1) typically 1.8 x I n 10 5 1 0.1 0.01 0 1 2 3 4 5 IK ...times rated current *1) current limitation typically 1.8 x I times rated current at I = 0.5 A...6 A n n current limitation typically 1.5 x In times rated current at In = 8 A or 10 A current limitation typically 1.3 x In times rated current at In = 12 A Table 4: Reliable trip of ESX10-T Reliable trip of ESX10-T with different cable lengths and cross sections Resistivity of copper 0 = Ub = DC 19.2 V (= 80 % of 24 V) 0.0178 (Ohm x mm2) / m voltage drop of ESX10-T and tolerance of trip point (typically 1.1 x In = 1.05 ... 1.35 x In) have been taken into account. 3 6 3.75 7.5 ESX10-T trips after 3 s 5.07 2.51 ESX10-T-selected rating In (in A) e. g. trip current Iab = 1.25 x In (in A) Rmax in Ohm = (Ub / Iab) - 0.050 The ESX10-T reliably trips from 0 Ohm to max. circuitry resistance Rmax 0.14 0.25 0.34 0.5 0.75 Cable cross section A in mm2 cable length L in meter cable resistance in Ohm = (R0 x 2 x L) / A (= single length) 5 1.27 0.71 0.52 0.36 10 2.54 1.42 1.05 0.71 15 3.81 2.14 1.57 1.07 20 5.09 2.85 2.09 1.42 25 6.36 3.56 2.62 1.78 30 7.63 4.27 3.14 2.14 35 8.90 4.98 3.66 2.49 40 10.17 5.70 4.19 2.85 45 11.44 6.41 4.71 3.20 50 12.71 7.12 5.24 3.56 75 19.07 10.68 7.85 5.34 100 25.34 14.24 10.47 7.12 125 31.79 17.80 13.09 8.90 150 38.14 21.36 15.71 10.68 175 44.50 24.92 18.32 12.46 200 50.86 28.48 20.94 14.24 225 57.21 32.04 23.56 16.02 250 63.57 35.60 26.18 17.80 214 m Example 1: max. length at 1.5 mm2 and 3 A 106 m Example 2: max. length at 1.5 mm2 and 6 A Example 3: mixed wiring: R1 = 40 m in 1.5 mm2 and R2 = 5 m in 0.25 mm2: (Control cabinet - sensor/actuator level) R1 = 0.95 Ohm, R2 = 0.71 Ohm Total (R1 + R2) = 1.66 Ohm 1 1.5 0.24 0.47 0.71 0.95 1.19 1.42 1.66 1.90 2.14 2.37 3.56 4.75 5.93 7.12 8.31 9.49 10.68 11.87 0.18 0.36 0.53 0.71 0.89 1.07 1.25 1.42 1.60 1.78 2.67 3.56 4.45 5.34 6.23 7.12 8.01 8.90 0.12 0.24 0.36 0.47 0.59 0.71 0.83 0.95 1.07 1.19 1.78 2.37 2.97 3.56 4.15 4.75 5.34 5.93 37 Electronic Circuit Protection ESX10-T Mounting examples for ESX10-T The ESX10-T features an integral power distribution system. LINE+ busbar 6720005315 (12.5 x n)-3 = length of busbars 0.5 e. g. (12.5 x 5)-3 = 59.5 0.5 continuous busbar 500 mm length, cut Up to 40 pole signal bar 6720005316 or jumper 6720005317 (2 pole only) remove protection against brush contact located on bottom side side walls or barriers for protection against brush contact on LINE+ and OV jumper locations insert protection against brush contact 0V busbar 6720005315 12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5 insert busbars and protection slides to be flush with housing sides insert signal bars to be flush with housing and place them centrally over the contacts 5 ESX10-TB with busbars and jumpers Mounting procedure: Before wiring insert busbars into protection block. 38 5 ESX10-TA with busbars + line entry LINE+ busbar power suppl y DC 24 V 1 LINE+ ESX10-TA-100 ESX10-TA-100 Electronic Circuit Protection ESX10-T ESX10-TA-100 0V Connection diagrams and application examples ESX10-T Signal contacts are shown in OFF or fault condition. 1 LINE+ 1 LINE+ +24V 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V 0 V busbar - line entry + load Connection diagrams and application examples ESX10-T... ESX10-TA-100 - + - - + load load ESX10-TB-101 ESX10-TB-101 Signal contacts ar e shown in OFF or fault concition. group signalling (series connection) group signaling (series connection) ESX10-TA-100 ESX10-TB-102 terminals for busbars Single signalling with common line entry screw terminals + line entry + line entry for the SI + line entry LINE+ busbar 1 LINE+ 1 LINE+ +24V LINE + busbar 1 LINE+ + line entry for the S I 13 +24V + line entry power suppl y DC 24 V ESX10-TA-100 ESX10-TA-100 ESX10-TA-100 0V 2 LOAD+ 3 0V 3 0V 3 0V 0V power supply DC 24 V 0 V busbar - line entry - + - 13 single signalling per way by means of an LED 14 1 LINE+ ESX10-TB-101 12 11 2 LOAD+ 3 0V 3 0V ESX10-TB-102 ESX10-TB-102 ESX10-TB-102 jumpers ar e staggered signal busbar for 0Vcommon busbar line entry - + load load 14 1 LINE+ 3 0V - line entry + load 13 1 1 LINE+ LINE+ ESX10-TB-101 ESX10-TB-101 12 12 11 11 2 LOAD+ 2 LOAD+ +24V 2 LOAD+ 14 1 LINE+ group signalling by means of an LED LINE+ busbar power supply DC 24 V 2 LOAD+ 1 LINE+ + 0V load 2 LOAD+ 3 0V + - load 2 LOAD+ + 3 0V - load 2 LOAD+ 3 0V 0 V busbar - line entry + ESX10-TB-101 + - load + - - load load group signalling (series connection) ESX10-TB-124 Single signalling with common reset ESX10-TB-124 + line entry for the SI ESX10-TB-102 ESX10-TB-102 + line entry Single signalling with common line entry LINE + busbar Single signaling with common line entry 1 +24V LINE+ 13 14 1 LINE+ 13 14 1 LINE+ 13 group signalling signalling per way bysingle means of an LED by means of an LED + line entry for the S I power supply DC 24 V + line entry jumpers ar e staggered 2 LOAD+ 2 LOAD+ 2 LOAD+ 1 3 0V LINE+ 1 3LINE+ 0V 1 3 LINE+ 0V 12 12 11 11 - line entry power supply DC 24 V + - + load ESX10-TB-102 0V ESX10-TB-101 ESX10-TB-101 ESX10-TB-101 0V +24V Single signaling with common reset 14 - + load ESX10-TB-102 single signalling per way by means of an LED + line entry LINE+ busbar LINE+ busbar signal busbar for common line entry - 22 0V busbar 1 LINE+ 1 LINE+ +24V 12 11 reset button RE SF 23 ESX10-TB-124 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V RE SF 23 22 RE SF 0V ESX10-TB-124 ESX10-TB-124 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V 0 V busbar - line entry 23 power supply DC 24 V load ESX10-TB-102 2 LOAD+ 22 1 LINE+ signal busbar for common reset 0V busbar - line entry + + - load + - - + load load load - + load - + - load ESX10-TB-124 Single signalling with common reset reset button single signalling per way by means of an LED + line entry LINE+ busbar 1 LINE+ 1 LINE+ +24V 22 RE SF 23 22 RE SF 1 LINE+ 23 22 RE SF 23 power supply DC 24 V ESX10-TB-124 0V ESX10-TB-124 ESX10-TB-124 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V signal busbar for common reset 0V busbar - line entry + load - + load - + - load 39 Electronic Circuit Protection ESX10-T Accessories for ESX10-T Description The ESX10-T features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: * LINE +(24VDC) * 0V Caution: T he electronic devices ESX10-T require a 0 V connection * signal contacts * reset inputs Description Busbars for LINE+ and 0 V max. load with one line entry (recommended: centre line entry) max. load with two line entries length: Part No. 6720005315 Imax Imax 500 mm Signal busbars for signal contacts and reset inputs max. load with one line entry with one series connection of signal contacts length: 6720005316 Imax Imax 500 mm Jumpers for signal contacts length: packing unit: 6720005317 21 mm 10 pcs Busbars for LINE+ and 0 V max. load with one line entry (recommended: centre line entry) max. load with two line entries grey insulation, length: 500 mm 6720005315 50 A 63 A 1A 0.5 A Busbars for LINE+ and 0 V grey insulation max. number of plug-on operations 10: 6720005335, (3-unit-block ESX10-T), length: 34.5 mm 6720005336, (4-unit-block ESX10-T), length: 47 mm 6720005337, (5-unit-block ESX10-T), length: 59.5 mm packing unit: 10 pcs 6720005474, (8-unit-block ESX10-T), length: 97 mm 6720005475, (10-unit-block ESX10-T), length: 122 mm packing unit: 4 pcs Connector bus link -K10 50 pin lugs to suitable for auxiliary contacts DIN 46230 (series connection) tinned copper 50 pin lugs to 6720005476 (1.5 mm2, brown) DIN 46230 o2.5 .099 o2.5 .099 tinned copper Supply module for LINE+ and 0 V suitable for ESX10-T... versions ampacity Imax 50 A AD-TX-EM01 ~70 ~2.76 For detailed installation instructions and approvals contact Weidmuller at 1-800-849-9343 or go to www.weidmuller.com 50 pin lugs to DIN 46230 tinned copper ~70 ~2.76 9102100000 ~70 ~2.76 TS32 rail adapter (Remove protection walls/barriers before using adapter.) o2.5 .099 Imax AD-TXEM01 40 50A Electronic Circuit Protection ESX10-TC 12VDC Electronic Circuit Protection ESX10-TC 12VDC Electronic circuit protection type ESX10-TC is designed to ensure selective disconnection of 12VDC load systems. 12VDC power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. Through selective disconnection the ESX10-TC responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX10-TC limits the highest possible current to 1.3 to 1.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 20,000 F, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX10-TC can be selected in fixed values from 1.0 A...10 A. Failure and status indication are provided by a multicolor LED and an integral short-circuit-proof status output or a relay signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation of individual load circuits. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. The load circuit can be reactivated via the remote electronic reset input, control input ormanually by means of the ON/OFF button. Features * Selective load protection, electronic trip characteristics *Active current limitation for safe connection of capacitive loads up to 20,000 F and on overload/short circuit * Current ratings 1 A...10 A at 12VDC *Reliable overload disconnection with 1.1 x In plus, even with long load lines or small cable cross sections (see table 3) * Manual ON/OFF button (S1) * Control input IN+ for remote ON/OFF signal (option) * Electronic reset input RE (option) *Clear status and failure indication through LED, status output SF * Integral fail-safe element adjusted to current rating * Width per unit only 12.5 mm * Rail mounting * Ease of wiring through busbar LINE+ and 0 V * Hazardous area approved- Class1 Div 2, Zone 2 (ATEX) The ESX10-TC, with a width of only 12.5 mm, can be snapped onto symmetrical rails for easy installation and control cabinet space savings. 41 Electronic Circuit Protection ESX10-TC 12VDC Technical Data (Tambient = 25C, operating voltage US = 12VDC) Operating data Operating voltage Ub 12VDC (9...18 V) Current rating In fixed current ratings: 1 A, 2 A, 3 A, 4 A, 6 A, 10 A Closed current I0 ON condition: typically 20...30 mA depending on signal output Status indication * multicolor LED: by means of GREEN: unit is ON, power-MOSFET is switched on - status output SF ON, supplies + 12VDC ORANGE: in the event of overload or short circuit until electronic disconnection RED: - unit electronically disconnected - load circuit/Power-MOSFET OFF - low voltage (< 3.25 V) - after switch-on till the end of switch-on delay OFF: - manually switched off (S1 = OFF) or device is dead - undervoltage * status output SF (option) * ON/OFF/ condition of switch S1 Load circuit Load output Power-MOSFET switching output (high side switch) Overload disconnection typically 1.1 x In (1.05...1.35 x In) Short-circuit current IK active current limitation (see table 1) Trip time see time/current characteristics for electronic disconnection typically 3 s at ILoad > 1.1 x In typically 3 s...50 ms at ILoad > 1.8 x In (or 1.5 x In/1.3 x In) Temperature disconnection internal temperature monitoring with electronic disconnection Low voltage monitoring with hysteresis at voltage dips < 500 ms, load output no reset required: load "OFF" at UB < 3.2 V typically 10 ms Starting delay tstart Disconnection of load circuit electronic disconnection Free-wheeling circuit external free-wheeling diode recommended with inductive load Several load outputs must not be connected in parallel 42 Technical Data (Tambient = 25C, operating voltage US = 12VDC) Status output SF Electrical data ESX10-TC-114/-124/ plus-switching signal output, connects Us to terminal 12 of module 17plus nominal data: 12VDC / max. 0.2 A (short circuit proof) status output is internally connected to GND with a 10 kM resistor Status OUT ESX10-TC-114/-124 (signal status OUT), +12 V = S1 is ON, load output connected through 0V = S1 is ON, load output blocked and/or switch S1 is OFF red LED lit OFF condition 0 V level at status output when: * switch S1 is in ON position, but device is still in switch-on delay * switch S1 is OFF, or control signal OFF, device is switched off * no operating voltage Us Reset input RE ESX10-TC-124 Electrical data voltage: max. +32VDC high > 4.5VDC 18VDC low 2.5VDC > 0 V power consumption typically 1.4 mA (+12VDC) min. pulse duration typically 10 ms Reset signal RE The electronically blocked ESX10-TC-124 (terminal 22) may remotely be reset via an external momentary switch due to the falling edge of a +12 V pulse. A common reset signal can be applied to several devices simultaneously. Switched on devices remain unaffected. Control input IN+ ESX10-TC-114 Electrical data see reset input RE Control signal IN+ +12V level (HIGH): device will be switched (terminal 21) on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal Switch S1 ON/OFF unit can only be switched on with S1 if a HIGH level is applied to IN+ Electronic Circuit Protection ESX10-TC 12VDC Technical Data (Tambient = 25C, operating voltage US = 12VDC) General data Fail-safe element: backup fuse for ESX10-T not required because of the integral redundant fail-safe element Terminals LINE+ / LOAD+ / 0V screw terminals M4 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 20-6 AWG (0.5 - 10 mm2) multi-lead connection (2 identical cables) rigid/flexible 20-11 AWG (0.5 - 4 mm2) flexible with wire end ferrule without plastic sleeve 20-13 AWG (0.5 - 2.5 mm2) flexible with TWIN wire end ferrule with plastic sleeve 20-9 AWG (0.5 - 6 mm2) wire stripping length 10 mm tightening torque (EN 60934) 1.2 Nm Terminals aux. contacts screw terminals M3 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 23-13 AWG (0.25 - 2.5 mm2) wire stripping length 8 mm tightening torque (EN 60934) 0.5 Nm Housing material moulded Table 1: voltage drop, current limitation, max. load current current rating typically voltage drop active current max. load current at 100% ON duty In Uon at In limitation (typically) Tu = 40 C Tu = 50 C 1A 80 mV 1.8 x In 1A 1A 2A 130 mV 1.8 x In 2A 2A 3A 80 mV 1.8 x In 3A 3A 4A 100 mV 1.8 x In 4A 4A 6A 130 mV 1.8 x In 6A 5A 10 A 150 mV 1.5 x In 10 A 9A Attention: w hen mounted side-by-side without convection the ESX10-TC should not carry more than 80% of its rated load with 100% ON duty due to thermal effects. Mounting Ambient temperature Storage temperature Humidity Vibration Degree of protection EMC (EMC directive, CE logo) Insulation co-ordination (IEC 60934) dielectric strength Insulation resistance (OFF condition) Dimensions (W x H x D) Mass ESX10-TC-114* Signal output Status OUT Positive 12V = OK x x Table 3: Specifications Protection EMC Insulation co-ordination CE logo UL ATEX n/a, only electronic disconnection 12.5 x 80 x 83 mm approx. 65 g Please note: * The user should ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the ESX10-TC used. * Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the ESX10-TC. * Refer to UL file for proper wiring and installation techniques. Table 2: ESX10-TC - Ordering Information Version Signal input Control input Remote ON/OFF Reset Reset ESX10-TC-114 x ESX10-TC-124x symmetrical rail to EN 50022-35x7.5 -20...+60 C (without condensation, see EN 60204-1) (with condensation upon request) -20...+70 C 96 hrs/95 % RH/40 C to IEC 60068-2-78-Cab climate class 3K3 to EN 60721 3 g, test to IEC 68-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050 emission: EN 61000-6-3 susceptibility: EN 61000-6-2 0.5 kV/2 pollution degree 2 re-inforced insulation in operating area max. 18VDC (load circuit) to EN6052 housing IP30, terminals IP00 emitted interference to EN 61000-6-3 noise immunity to EN 61000-6-2 0.5 kV / pollution degree 2, re-inforced insulation in operating area to IEC60934 / IEC60664 to 2004/108/EG and 94/9/EG UL2367, File No E306740 UL508, File No E322549 UL 1604, File No E320024 IEC/EN60079-0 /-14/-15 II 3G Ex nA II B T4 Gc X Current Rating (amps) 1 2 3 4 6 10 Control Input Part Number 6720005351 6720005352 6720005353 6720005354 6720005356 6720005357 ESX10-TC-124** Current Rating (amps) 1 2 3 4 6 10 Control Input Part Number 6720005331 6720005471 6720005333 6720005334 6720005472 6720005473 * Control force input on/off ** Reset input only to reset under fault conditions 43 electronic control unit ON/OFF Electronic Circuit Protection ESX10-TC 12VDC status indication green/orange/red RE reset input SF status output ESX10-TC-114 with control input IN+ (+12VDC) with status output SF (+12 V = loadLOAD output (+) ON) load output LINE+ 0V Schematic diagram Schematic diagram ESX10-TC-124-DC 12 V (Example) (Example) ESX10-TC-124-... ESX10-TC-124 with reset input RE (+12VDC ) with status output SF (+12 V = load output ON) 1 LINE+ LINE (+) 24VDC 1 SF 23 IN 21 RE 22 2 LOAD+ 2 LOAD+ Rsense Terminal wiring diagram ESX10-TC-124-DC 12 V (Example) SF 23 DC12V xxA S1 electronic control unit Rsense ESX10-TC Signal inputs / outputs (wiring diagram) Failsafe Failsaf S1 ON/OFF status indication green/orange/red RE reset input SF status output ok r e s e t on off 0V 0V 3 LOAD (+) load output 3 0V 2 LOAD+ operating condition: SF +12 V = OK fault condition: SF 0 V operating condition: SF +12 V = OK fault condition: SF 0 V Terminal wiring diagram and dimensions Dimensions Terminal wiring diagram ESX10-TC-124-DC 12 V (Example) Time/Current characteristic curve (Ta = 25 C) 83 3.27 12.5 disconnection typically 1.1 x I n 1.8 x I n *1) .492 10000 DC12V xxA 1000 ok on r e s e t 2 LOAD+ 80 3.15 Label 100 trip time in seconds 80 3.15 DC12V xxA ok 10 5 r e s e t 2 LOAD+ 1 0.1 0.01 Dimensions 0 snap-on socket for symmetrical rail EN 50022-35x7.5 on off current limitation *1) typically 1.8 x I n 1 2 83 3.27 4 3 ...times rated current current limitation typically 1.8 x In times rated current at In = 1.0 A...6 A 5 IK 12.5 .492 current limitation typically 1.5 x In times rated current at In = 10 A * The trip time is typically 3 seconds in the range between 1.1 and 1.8 xDC12V In. 80 3.15 xxA * Electronic current limitation occurs at typically 1.8 x In which means that under all overload conditions (independent of the power supply and the resistance ofr the load e s circuit) the max. overload before disconnection will not exceed 1.8 x In times the e t current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit). ok on 2 LOAD+ * Without this current limitation a considerably higher overload current would flow in 80 the event of an overload or short circuit. 3.15 Label 44 snap-on socket for symmetrical rail EN 50022-35x7.5 Electronic Circuit Protection ESX10-TC 12VDC TheAccessories ESX10-TC-DC 12 V features an integral power distribution system. for ESX10-TC LINE+ busbar 6720005315 remove protection against brush contact from bottom side continuous busbar 500 mm length, cut (12.5 x n)-3 = length of busbars 0.5 e. g. (12.5 x 5)-3 = 59.5 0.5 insert protection against brush contact 0 V busbar 6720005315 12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5 insert busbars and protection slides to be flush with housing sides Mounting procedure: Before wiring, insert busbars into protection block. Max. 10 insertion/removal cycles for busbars. 5 ESX10-TC with busbars Recommendation: Every 10 units busbars should be interrupted and fed in anew. Table of lengths for busbars: (see accessories) No. of Units Length of busbar [mm] + 0.5 mm 2 22 3 34.5 4 47 5 59.5 6 72 7 84.5 8 97 9 10.95 10 122 Accessories for ESX10-TC The ESX10-TC features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: * LINE +(12VDC) * 0V Caution: T he electronic devices ESX10-TC require a 0 V connection Description Busbars for LINE+ and 0 V max. load with one line entry 50 A (recommended: center line entry) Imax max. load with two line entries Imax 63 A length: 500 mm Part No. 6720005315 TS32 rail adapter 9102100000 (Remove protection walls/barriers before using adapter.) For detailed installation instructions and approvals contact Weidmuller at 1-800-849-9343 or go to www.weidmuller.com 45 Electronic Circuit Protection ESX10-TC 12VDC Accessories Busbars for LINE+ and 0 V Supply module for LINE+ and 0 V max. load with one line entry (recommended: centre line entry) max. load with two line entries suitable for ESX10-T... versions Description Busbars for LINE+ and O V Insulation Color Grey Length 500mm Part No. 6720005315 AD-TXEM01 Busbars for LINE+ and 0 V grey insulation max. number of plug-on operations 10: Description Supply module for LINE+ and O V Length 34.5mm Insulation Color Grey Packing Unit 10 50 pin lugs to o2.5 .099 Part No. 6720005335 6720005336 47mm DIN 46230 Grey 10 59.5mm Grey 10 6720005337 97mm Grey DIN 46230 4 .099 6720005474 122mm Grey 4 6720005475 tinned copper 50 pin lugs to ~70 ~2.76 o2.5 tinned copper ~70 ~2.76 Description Busbars for LINE+ and O V (3-unit-block ESX 10-T) Busbars for LINE+ and O V (4-unit-block ESX 10-T) Busbars for LINE+ and O V (5-unit-block ESX 10-T) Busbars for LINE+ and O V (8-unit-block ESX 10-T) Busbars for LINE+ and O V (10-unit-block ESX 10-T) Connector bus link - K10 suitable for auxiliary contacts (series connection) o2.5 .099 ~70 ~2.76 50 pin lugs to DIN 46230 tinned copper Description Connector bus link - K10 46 Length 1.5mm2 Insulation Color Brown Part No. 6720005476 Imax 50A Part No. AD-TX-EM01 SPD II 1 Series SPD II 1 - Surge Protectors for AC Power Distribution SPD II PV - Surge Protectors for DC Photovoltaic Installations Weidmuller's SPD II 1 series transient voltage surge protectors consist of a range of innovative, compact modules for the protection of low voltage AC distribution systems or (PV models) for DC photovoltaic installations. In AC applications, the SPD II 1 would be installed downstream of the main circuit breaker and fuse(s), connected between each live conductor to be protected and ground. For multi-phase circuits, multiple modules are used with jumper options between ground terminals and permitting a single connection to ground. In photovoltaic applications, the SPD II 1 PV would typically be in a combiner enclosure protecting the DC output and return conductor to ground. Voltage limiting technology is integrated, which differentiates between transient pulses and longer-lasting overvoltages. This circuitry eliminates the disadvantages of varistor devices (MOVs) which, in competitive products, may switch-on inadvertently in conditions where the supply voltage is not well-regulated. Weidmuller's hybrid arrester design ensures efficient MOV operation and hence conserves energy, maximizes the operating lifetime of the arrester and eliminates arcing when the thermal disconnect operates. Each module is a two-part construction, comprising a TS35 DINrail mountable base and a pluggable replaceable arrester, with each single-conductor assembly only 18mm wide. Products are specified by their working voltage level, or maximum continuous operating voltage (MCOV) and each has a maximum surge current rating of 50kA. Base/arrester assemblies are available either with or without a remote signaling option and arresters are available as spare parts. * * * * * * * Models for LV AC distribution or photovoltaic installations Quick replacement with spare pluggable, replaceable arresters Nominal voltages up to 480VAC (550V MCOV) or 1200VDC Maximum surge current (Imax) 50kA Remote status signaling option UL1449 Ed3 approved and CSA equivalent No discharge path fuse needed (Type 2) 47 SPD II 1 Series For transient voltage protection of single and multi-phase circuits, in the main electrical panel, downstream of the main circuit breaker, or in control panels. SPD II 0 150V/40kA SPD II 1 150V/40kA SPD II 1 R 150V/40kA SPD II 0 280V/40KA SPD II 1 280V/40KA SPD II 1 R 280V/40KA R model shown Technical Data R model shown AC Network 120 V, Single phase 230 V, Single phase Connection Mode 1 Pole, L-N or L-G. 1 Pole, L-N or L-G. Max. Operating Voltage (MCOV) 150 VAC 277 VAC Leakage Current at Uc <1mA <1mA Follow Current None None UL 1449 Category Type 2 Type 2 UL Nominal Discharge Current (In), 15 Impulses 8/20 us Max. Discharge Current (Imax), 1 Impulse 8/20 us UL Voltage Protection Rating (VPR) 20 kA 20 kA 50 kA 50 kA 1.2 kV 1.6 kV Protection Level (Up) 1200 V 1600 V UL Short-Circuit Current Rating (SCCR) 200 kA 200 kA Sparkover time / Drop-out time <100 ns <100 ns Overcurrent Protection No fuse required in discharge circuit No fuse required in discharge circuit Connection (network) Screw connections (2 - 14AWG) Screw connections (2 - 14AWG) Remote Signal Option (Contact Rating) 250 V / 0,5 A, 48 VDC /0,1 A 250 V / 0,5 A, 48 VDC /0,1 A Mounting DIN-rail, TS 35 DIN-rail, TS 35 Operating Temp -40C...+70C -40C...+70C Operating Altitude (Max.) 2,000m 2,000m Relative Humidity 0 - 95% non-condensing 0 - 95% non-condensing Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP 20 IP 20 Weight (g) and Dimensions (mm) SPD II 0 SPD II 1 SPD II 1 R 66 g; 18W x 45H x 60D 138 g; 18W x 90H x 73.5D 142 g; 18W x 100H x 73.5D 66 g; 18W x 45H x 60D 140 g; 18W x 90H x 73.5D 142 g; 18W x 100H x 73.5D UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 Approvals UL 1449 (USA and CANADA) C US Ordering Data Surge Protector Spare arrester 120V nom. Type SPD II 0 150V/40kA Spare arrester 230V nom. -- SPD assembly w/o relay SPD II 1 150V/40kA SPD assembly with relay SPD II 1 R 150V/40kA. Bus bars 2-pole jumper Type -- Part No. -- -- SPD II 0 280V/40kA 1348370000 1348340000 SPD II 1 280V/40kA 1348380000 1348350000 SPD II 1 R 280V/40kA. 1348390000 Type QB 18-2 Part No. 8877540000 Type QB 18-2 Part No. 8877540000 3-pole jumper QB 18-3 8877500000 QB 18-3 8877500000 4-pole jumper QB 18-4 8877520000 QB 18-4 8877520000 73 9 Part No. 1348330000 18 90.5 Dimensions 48 Electrical Function 2-, 3- and 4-pole Jumpers SPD II 1 Series For transient voltage protection of single and multi-phase circuits, in the main electrical panel, downstream of the main circuit breaker, or in control panels. SPD II 0 400V/40KA SPD II 1 400V/40KA SPD II 1 R 400V/40KA SPD II 0 550V/40kA SPD II 1 550V/40kA SPD II 1 R 550V/40kA R model shown Technical Data R model shown AC Network 277/347 V, Single phase 480 V, Single phase Connection Mode 1 Pole, L-N or L-G. 1 Pole, L-N or L-G. Max. Operating Voltage (MCOV) 385 VAC 550 VAC Leakage Current at Uc <1mA <1mA Follow Current* None None UL Category Type 2 Type 2 UL Nominal Discharge Current (In), 15 Impulses 8/20 us Max. Discharge Current (Imax), 1 Impulse 8/20 us UL Voltage Protection Rating (VPR) 20 kA 20 kA 50 kA 50 kA 1.8 kV 2.5 kV Protection Level (Up) 1800 V 2500 V UL Short-Circuit Current Rating (SCCR) 200 kA 200 kA Sparkover time / Drop-out time <100 ns <100 ns Overcurrent Protection No fuse required in discharge circuit No fuse required in discharge circuit Connection (network) Screw connections (2 - 14AWG) Screw connections (2 - 14AWG) Remote Signal (Contact Rating) 250 V / 0,5 A, 48 VDC /0,1 A 250 V / 0,5 A, 48 VDC /0,1 A Mounting DIN-rail, TS 35 DIN-rail, TS 35 Operating Temp -40C...+70C -40C...+70C Operating Altitude (Max.) 2,000m 2,000m Relative Humidity 0 - 95% non-condensing 0 - 95% non-condensing Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP 20 IP 20 Weight (g) and Dimensions (mm) SPD II 0 SPD II 1 SPD II 1 R 66 g; 18W x 45H x 60D 138 g; 18W x 90H x 73.5D 150 g; 18W x 100H x 73.5D 66 g; 18W x 45H x 60D 138 g; 18W x 90H x 73.5D 150 g; 18W x 100H x 73.5D UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 Surge Protector Spare arrester 277V nom. Type SPD II 0 400V/40kA Type -- Spare arrester 440/480V nom. -- -- SPD II 0 550V/40kA 1348440000 SPD assembly w/o relay SPD II 1 400V/40kA 1348420000 SPD II 1 550V/40kA 1348450000 SPD assembly with relay SPD II 1 R 400V/40kA. 1348430000 SPD II 1 R 550V/40kA. 1348470000 Bus bars 2-pole jumper Type QB 18-2 Part No. 8877540000 Type QB 18-2 Part No. 8877540000 Approvals UL 1449 (USA and CANADA) C US Ordering Data Part No. 1348400000 Part No. -- 3-pole jumper QB 18-3 8877500000 QB 18-3 8877500000 4-pole jumper QB 18-4 8877520000 QB 18-4 8877520000 73 9 18 90.5 Dimensions Electrical Function 2-, 3- and 4-pole Jumpers 49 SPD II 1 Series Basic AC configurations 1 (with remote signaling options) L/N L/N TF L/N TF L1 TF L2 TF TF SPD parts needed: Nom. V Description Qty Qty Qty 110/120V SPD II 150V/40kA 1 2 3 1348350000 230/240V SPD II 280V/40kA 1 2 3 1348390000 277V SPD II 400V/40kA 1 2 3 1348430000 480V SPD II 550V/40kA 1 2 3 1348470000 All QB18-2 0 1 0 8877540000 All QB18-3 0 0 1 8877500000 Basic AC configurations 2 (with remote signaling options) L1 L2 TF TF L3 N TF TF SPD parts needed: 50 Nom. V Description 110/120V SPD II 1 R 150V/40kA Qty 4 1348350000 Part No. 230/240V SPD II 1 R 280V/40kA 4 1348390000 277V SPD II 1 R 400V/40kA 4 1348430000 480V SPD II 1 R 550V/40kA 4 1348470000 All QB 18-4 1 8877520000 Part No. L3 TF SPD II 1 Series For use on the DC side of photovoltaic SPD II 0 PV 600VDC SPD II 2 PV 600VDC installations, typically in a combiner enclosure, protecting the DC output and SPD II 2 R PV 600VDC return conductor to the ground. SPD II 0 PV 1000VDC SPD II 2 PV 1000VDC SPD II 2 R PV 1000VDC R model shown SPD II 0 PV 1200VDC SPD II 3 PV 1200VDC SPD II 3 R PV 1200VDC R model shown R model shown Technical Data DC Network 600 VDC 1000 VDC 1200 VDC Connection Mode Screw connection Screw connection Screw connection Max. Operating Voltage (MCOV) 550 VDC 1000 VDC 1200 VDC Leakage Current at Uc UL Category <1mA <1mA <1mA Type 2 Type 2 Type 2 UL Nominal Discharge Current (In), 5 Impulses 8/20 us Max. Discharge Current (Imax), 1 Impulse 8/20 us UL Voltage Protection Rating (VPR) 20 kA 20 kA 20 kA 50 kA 50 kA 50 kA 2 kV 4 kV 4 kV Protection Level (Up) 2000 V 4000 V 4000 V UL Short-Circuit Current Rating (SCCR) 200 kA 200 kA 200 kA Sparkover time / Drop-out time <100 ns <100 ns <100 ns Overcurrent Protection No fuse required in discharge circuit No fuse required in discharge circuit No fuse required in discharge circuit Connection (network) Screw connection, pluggable Screw connection, pluggable Screw connection, pluggable Remote Signal (Contact Rating) 250 V / 0,5 A, 48 VDC /0,1 A 250 V / 0,5 A, 48 VDC /0,1 A 250 V / 0,5 A, 48 VDC /0,1 A Mounting DIN-rail, TS 35, TS 35 x 15, TS 35 x 7.5 DIN-rail, TS 35, TS 35 x 15, TS 35 x 7.5 DIN-rail, TS 35, TS 35 x 15, TS 35 x 7.5 Operating Temp -40C...+70C -40C...+70C -40C...+70C Operating Altitude (Max.) 2000m 2000m 2000m Relative Humidity 0 - 95% non-condensing 0 - 95% non-condensing 0 - 95% non-condensing Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP 20 IP 20 IP 20 Weight (g) 274 292 402 Dimensions (mm) 36W x 100H x 73.5D 36W x 100H x 73.5D 54W x 100H x 73.5D UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 UL File E354261, Type 2 UL1449 Ed. 3, CSA Electrical Notice No. 516 Approvals UL 1449 (USA and CANADA) C US Ordering Data Surge Protector Spare arrester 600V nom. Type SPD II 0 PV 600VDC Part No. 1348520000 Type -- Part No. -- 1348480000 Spare arrester 1000V nom. -- -- SPD II 0 PV 1000VDC Spare arrester 1200V nom. -- -- -- -- Type -- Part No. -- -- -- SPD II 0 PV 1200VDC 1348550000 PV SPD assembly w/o relay SPD II 2 PV 600VDC 1348540000 SPD II 2 PV 1000VDC 1348490000 SPD II 3 PV 1200VDC 1348570000 PV SPD assembly with relay SPD II 2 R PV 600VDC 1348430000 SPD II 2 R PV 1000VDC 1348500000 SPD II 3 R PV 1200VDC 1348580000 73 9 36 54 SPD II 2 PV SPD II 3 PV 90.5 Dimensions Electrical Function PSPD II 2 R PV Electrical Function PSPD II 3 PV 51 SPD II & III - AC Surge Protectors SPD II & III - AC Surge Protector The SPD II range of surge protectors are used for transient surge protection of single and multi-phase power circuits at the main electrical panel. SPD IIIs are for the protection of individual electrical devices. They provide common-mode protection (between each Line and Ground), with impulse discharge capacity (Imax) 40kA for SPD II and 20kA for SPD III. The SPD design is based on high-energy varistors (MOVs) equipped with thermal disconnects and integral failure indicators. A remote signaling contact for disconnection indication is standard on each unit. For ease of replacement, varistors are housed in pluggable modules with connections that are mechanically keyed to the base to prevent incorrect arrestor module replacement. Typical applications include low voltage distribution or protection of industrial control systems, equipment assemblies and devices. 52 SPD II & III - AC Surge Protectors For transient voltage protection of single and multi-phase circuits, in the main electrical panel, downstream of the main circuit breaker, or in control panels. SPD II 120V/40kA SPD II 230V/40kA Technical Data AC Network 120/240V, 120/208V 220/380V, 240/415V Connection Mode 1 Pole, L-N or L-G 1 Pole, L-N or L-G Max. Operating Voltage (MCOV) 150VAC 275VAC TOV Withstand 150VAC 275VAC Leakage Current at Uc <1mA <1mA Follow Current none none UL Nominal Discharge Current (In), 15 impulses 8/20 s 20kA 20kA Max. Discharge Current (Imax), 1 impulse 8/20 s 40kA 40kA UL Voltage Protection Rating (VPR) 500V 900V Protection Level (Up) 0.9kV 1.25kV UL Short-Circuit Current Rating (SCCR) 25kAIC 25kAIC AC System Single-phase Single-phase Thermal Disconnector UL 60691 UL 60691 Overcurrent Protection Time Delay - 125A Max. Time Delay - 125A Max. Dimensions (mm) 90 x 18 x 67 90 x 18 x 67 Connection Screw terminals, #4 AWG Max. Screw terminals, #4 AWG Max. Remote Signal Indicator 250VAC Max, 2A 250VAC Max, 2A Mounting Din-rail, TS35 Din-rail, TS35 Operating Temp -50C to +85C -50C to +85C Operating Altitude (Max.) 13,000 ft (4,000m) 13,000 ft (4,000m) Relative Humidity 5 to 95% non-condensing, up to 100% external 5 to 95% non-condensing, up to 100% external Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP20 IP20 Weight 3.4 oz 3.4 oz IEC 61643-1 - INTERNATIONAL Class I, Class II Class I, Class II EN 61643-11 - EUROPE Class I, Class II NF EN 61643-11 - FRANCE Class67 I, Class II UL1449 3rd Edition - USA and CANADA Low Voltage SPD RoHS Directive 2002/95/EC Approvals Class I, Class II Class I, Class II 18 Low Voltage SPD 10.6 Directive 2002/95/EC L/N Ordering Data Surge Protector Type 90 SPD II 120V/40kA Bus bars Part No. Type Part No. 6720005410 SPD II 230V/40kA 6720005411 Type Part No. Type Part No. SPD 2P LINK 6720005417 SPD 2P LINK 6720005417 SPD 3P LINK 6720005418 SPD 3P LINK 6720005418 SPD 4P LINK 6720005419 SPD 4P LINK 6720005419 L/N 10.6 1.4 1.1 1.2 18 67 C L/N Mi Ft t o 90 V V: High-energy varistor Ft: Thermal fuse C: Remote signaling contact t0: Thermal disconnection system Mi: Disconnection indicator L/N 1.4 1.1 1.2 SPD II bus bars C 53 SPD II & III - AC Surge Protectors For transient voltage protection of single and multi-phase circuits, in the main electrical panel, downstream of the main circuit breaker, or in control panels. SPD II 277V/40kA SPD II 480V/40kA Technical Data AC Network 220/380V, 277V 347/600V, 480V Connection Mode 1 Pole, L-N or L-G 1 Pole, L-N or L-G Max. Operating Voltage (MCOV) 400VAC 550VAC TOV Withstand 400VAC 550VAC Leakage Current at Uc <1mA <1mA Follow Current none none UL Nominal Discharge Current (In), 15 impulses 8/20 s 20kA 20kA Max. Discharge Current (Imax), 1 impulse 8/20 s 40kA 40kA UL Voltage Protection Rating (VPR) 1500V 1800V Protection Level (Up) 1.8kV 2.5kV UL Short-Circuit Current Rating (SCCR) 25kAIC 25kAIC AC System Single-phase Single-phase Thermal Disconnector UL 60691 UL 60691 Overcurrent Protection Time Delay - 125A Max. Time Delay - 125A Max. Dimensions (mm) 90 x 18 x 67 90 x 18 x 67 Connection Screw terminals, #4 AWG Max. Screw terminals, #4 AWG Max. Remote Signal Indicator 250VAC Max, 2A 250VAC Max, 2A Mounting Din-rail, TS35 Din-rail, TS35 Operating Temp -50C to +85C -50C to +85C Operating Altitude (Max.) 13,000 ft (4,000m) 13,000 ft (4,000m) Relative Humidity 5 to 95% non-condensing, up to 100% external 5 to 95% non-condensing, up to 100% external Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP20 IP20 Weight 3.4 oz 3.4 oz Approvals IEC 61643-1 - INTERNATIONAL Class I, Class II Class I, Class II EN 61643-11 - EUROPE Class I, Class II Class I, Class II Class I, Class II 18 NF EN 61643-11 - FRANCE Class 67 I, Class II UL1449 3rd Edition - USA and CANADA Low Voltage SPD RoHS Directive 2002/95/EC Low Voltage SPD 10.6 Directive 2002/95/EC L/N Ordering Data Surge Protector 90 Type SPD II 277V/40kA Part No. Type Part No. SPD 2P LINK 6720005417 SPD 2P LINK 6720005417 SPD 3P LINK 6720005418 SPD 3P LINK 6720005418 SPD 4P LINK 6720005419 SPD 4P LINK 6720005419 L/N 10.6 C L/N Mi Ft t o 90 Part No. 6720005413 Type 18 67 Type SPD II 480V/40kA 1.4 1.1 1.2 Bus bars Part No. 6720005412 V V: High-energy varistor Ft: Thermal fuse C: Remote signaling contact t0: Thermal disconnection system Mi: Disconnection indicator 54 L/N 1.4 1.1 1.2 SPD II bus bars C SPD II & III - AC Surge Protectors For transient voltage protection of multi-phase circuits with TT grounding systems. SPD II N/PE 67 18 N Technical Data Network 230/400V, 120/208V Max. Operating Voltage (MCOV) 255VAC TOV Withstand 400VAC Leakage Current at Uc none Follow Current 100A Nominal Discharge Current (In), 15 impulses 8/20 s 20kA Max. Discharge Current (Imax), 1 impulse 8/20 s 40kA Protection Level (Up) 1.5kV UL Short-Circuit Current Rating (SCCR) 25kAIC Dimensions (mm) 90 x 18 x 67 Connection Screw terminals, #4 AWG Max. Mounting Din-rail, TS35 Operating Temp -40C to +85C Enclosure Material Thermoplastic UL94-V0 Environmental Rating IP20 Class II EN 61643-11 - EUROPE Class II NF EN 61643-11 - FRANCE Class II UL1449 3rd Edition - USA and CANADA Low Voltage SPD 18 N 90 N GDT Approvals IEC 61643-1 - INTERNATIONAL 90 67 GDT: Specific gas tube N GDT Ordering Data Surge Protector Bus bars Type Part No. SPD II N/PE 6720005414 Type Part No. SPD S LINK 1/3 6720005461 SPD II bus bars 55 SPD II & III - AC Surge Protectors SPD II 240V/G/40kA SPD II 120V/G/40kA For devices with single phase voltage supplies * Protects L & N conductors (common and differential modes) * Integrated contact for remote status indication * Local status indicator on arrester * Quick replacement with pluggable arrester Technical Data AC Network 120V 230V Connection Mode TN-TT TN Max. Operating Voltage (MCOV) 150VAC 255VAC TOV Withstand 150VAC 255VAC Leakage Current at Uc <1mA <1mA Protection Mode MC/MD MC/MD Nominal Discharge Current (In), 15 impulses 8/20 s 20kA 20kA Max. Discharge Current (Imax), 1 impulse 8/20 s 40kA 40kA Protection Level (Up) 1.5/0.9kV 1.5/1.25kV Residual Voltage @ 5k 0.6kV 0.9kV Short-Circuit Current Rating (SCCR) 10kAIC 10000 A AC System Single-phase Single-phase Thermal Disconnector Internal Internal Overcurrent Protection Fuses type gG 50A Max. Fuses type gG 50A Max. Dimensions (mm) 90 x 18 x 58 90 x 18 x 67 Connection Screw terminals, #4AWG Max. Screw terminals, #4AWG Max. Disconnection Indicator 2 mechanical indicators 2 mechanical indicators Installation Ground Fault Breaker Type S or delayed Type S or delayed Mounting Din-rail, TS35 Din-rail, TS35 Operating Temp -40C to +85C -40C to +85C Operating Altitude 13,000 ft (4,000m) 13,000 ft (4,000m) Relative Humidity 5 to 95% non-condensing, up to 100% external 5 to 95% non-condensing, up to 100% external Enclosure Material Thermoplastic UL94-V0 Thermoplastic UL94-V0 Environmental Rating IP20 IP20 Weight 3.4 oz 3.4 oz IEC 61643-1 - INTERNATIONAL Low Voltage SPD - Test Class II Low Voltage SPD - Test Class EN 61643-11 - EUROPE Low Voltage SPD - Test Class II Low Voltage SPD - Test Class NF EN 61643-11 - FRANCE Low Voltage SPD - Test Class II Parafoudre Basse Tension - Essais Classe UL1449 3rd Edition - USA and CANADA UL file E338172, CSA file 253665 UL file E338172, CSA file 253665 Approvals Imax 40 kA Ordering Data Surge Protector Bus bars 67 Type Part No. Type Part No. SPD II 120V/G/40kA Type 6720005415 Part No. SPD II 240V/G/40kA Type 6720005403 Part No. SPD 2P LINK SPD 3P LINK SPD 4P LINK 6720005417 6720005418 6720005419 SPD 2P LINK SPD 3P LINK SPD 4P LINK 6720005417 6720005418 6720005419 L 10.6 L N C N Ft to V 90 GDT SPD II bus bars 56 1.4 1.1 1.2 18 V: High-energy varistor GDT: High energy gas tube Ft: Thermal fuse C: Remote signaling contact t0: Thermal disconnection system SPD II & III - AC Surge Protectors For transient voltage protection of single-phase devices. SPD III 120V/40kA * Protects 2 conductors - typically L & N, but could also be L1 & L2 * Integrated contact for remote status indication * Pluggable replaceable arrester Imax 40 k Technical Data 67 AC Network 120V Connection Mode TN Max. Operating Voltage (MCOV) 150VAC TOV Withstand 150VAC Max load current 16A Leakage Current at Uc <1mA Follow Current none Nominal Discharge Current (In), 15 impulses 8/20 s 20kA Max. Discharge Current (Imax), 1 impulse 8/20 s 40kA Protection Level (Up) 1.5/0.9kV Short-Circuit Current Rating (SCCR) 10kAIC AC System Single-phase Thermal Disconnector UL 60691 Internal Overcurrent Protection Fuses type gG - 50A Max. Dimensions (mm) 90 x 18 x 58 Connection Screw terminals, #4 AWG Max. Remote Signal Indicator 250VAC Max, 2A Mounting Din-rail, TS35 Operating Temp -40C to +85C Operating Altitude 13,000 ft (4,000m) Relative Humidity 5 to 95% non-condensing, up to 100% external Enclosure Material Thermoplastic UL94-V0 Environmental Rating IP20 Weight 3.4 oz Approvals L Class II, Class III EN 61643-11 - EUROPE Class II, Class III NF EN 61643-11 - FRANCE Class II, Class III UL1449 3rd Edition - USA and CANADA UL file E338172, file 253665 N N L/N L/N Ft Ft 1.4 1.1 1.2 L C C Ft L/N C C Ft Ft o t to to V V GDT V V : High energy varistor GDT : High energy Gas tube Ft : Thermal fuse C : Remote signaling contact t : Thermal disconnection system 1.4 1.1 1.2 L/N 1.4 1.1 1.2 N o V V L t to to GDT 1.4 1.1 1.2 90 Ft IEC 61643-1 - INTERNATIONAL 18 10.6 V V: High-energy varistor GDT: High energy gas tube Ft: Thermal fuse C: Remote signaling contact t0: Thermal disconnection system Ordering Data Surge Protector Type Part No. SPD III 120V/40kA 6720005416 57 SPD II & III - AC Surge Protectors Basic configurations 1 L/N L/N TF L/N TF L1 TF L2 TF L3 TF TF SPD parts needed: Nom. V Description Qty Qty Qty Part No. 110/120V SPD II 120V/40kA 1 2 3 6720005410 230/240V SPD II 230V 40kA 1 2 3 6720005411 277V SPD II 277V 40kA 1 2 3 6720005412 480V SPD II 480V 40kA 1 2 3 6720005413 All SPD 2P Link 0 1 0 6720005417 All SPD 3P Link 0 0 1 6720005418 Basic configurations 2 L1 SPD parts needed: L2 TF L3 TF TF N TF Nom. V Description Qty Part No. 110/120V SPD II 120V/40kA 4 6720005410 230/240V SPD II 230V 40kA 4 6720005411 277V SPD II 277V 40kA 4 6720005412 480V SPD II 480V 40kA 4 6720005413 All SPD 4P Link 1 6720005419 Basic configurations 3 TT network Nom: 120V L1 TT network N L1 TF TF SPD parts needed: 58 L2 TF L3 N TF SPD parts needed: Nom. V Description Qty Part No. Nom. V Description Qty Part No. 120V SPD II 120V/G/40kA 1 6720005415 110/120V SPD II 120V/40kA 3 6720005410 230/240V SPD II 230V 40kA 3 6720005411 277V SPD II 277V 40kA 3 6720005412 480V SPD II 480V 40kA 3 6720005413 All SPD II N/PE 1 6720005414 All SPD S Link 1/3 1 6720005461 Quick Selection Guide VARITECTOR - Surge Protection for Control I/O Signals Product quick selection for measurement and control signals Instrumentation and control equipment Interface/ signal Mounting Connection system Protected Discharge Operating max. wires capacity current voltage 0(4) ... 20 mA 0(4) ... 20 mA 0...10 V 0...10 V 0-20 mA, 4-20 mA on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact Screw terminals Screw terminals Screw terminals Screw terminals Tension clamp terminals 4 2 4 2 2 8/20 s 5 kA 5 kA 5 kA 5 kA 5 kA VSSC and VSPC for binary signals Hart Cathodic corrosion protection PT 100, PT 1000 PT 100 RS232 RS422,V11 RS422A, V.11, X.27, RS423A RS449 RS485 RS485 RS485 RS232-C / V.24 TTL TTY on DIN-rail, compact Screw terminals 2 on DIN-rail, separable on DIN-rail, separable Screw terminals Screw terminals on DIN-rail, compact on DIN-rail, binary on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable Protection device Part No. Arrestor Part No. Direct earthing base 8924710000 8924730000 8924710000 8924730000 Part No. Indirect earthing base 8924270000 8924290000 8924270000 8924290000 DC 28 V 28 V 28 V 28 V 28 V VSPC 2CL 24 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A VSPC 2CL 24 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A MCZ OVP 1CL 24 V 0.5 A 5 kA Imax. 0.45 A 0.45 A 0.45 A 0.45 A 0.5 A 1.25 A 0.5 A 8924470000 8924480000 8924470000 8924480000 8448920000 8449080000 2 2 5 kA 5 kA 0.45 A 2A 28 V 72 V VSPC 1CL 24 V DC 0.5 A VSPC GDT 2 CH 90 V 20 kA 8924480000 8924730000 8924290000 8924570000 8924740000 8924300000 Tension clamp terminals Screw terminals Tension clamp terminals Tension clamp terminals Screw terminals 2 4 2 2 4 5 kA 5 kA 5 kA 5 kA 5 kA 1.25 A 0.45 A 0.5 A 0.5 A 0.45 A 24 V 24 V 24 V 24 V 15 V MCZ OVP SL 24 V 1.25 A VSPC 3/4WIRE 24 V DC MCZ OVP SL 24 V 0.5 A MCZ OVP SL 24 V 0.5 A VSPC 2CL HF 12 V DC 8448970000 8924550000 8924740000 8924300000 8448940000 8448940000 8924460000 8924710000 8924270000 on DIN-rail, separable on DIN-rail, compact built-in housing on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, compact Screw terminals Tension clamp terminals Screw terminals Screw terminals Screw terminals Tension clamp terminals Tension clamp terminals 4 2 4 4 4 2 2 5 kA 5 kA 0.5 kA 5 kA 5 kA 5 kA 5 kA 0.45 A 0.5 A 15 V 24 V 12 V 6.4 V 15 V 24 V 24 V VSPC 2CL HF 12 V DC MCZ OVP SL 24 V 0.5 A RS485/RS422 K21 VSPC R485 2 CH VSPC 2CL HF 12 V DC MCZ OVP SL 24 V 0.5 A MCZ OVP SL 24 V 0.5 A 8924460000 8924710000 8924270000 8448940000 8008501001 8924670000 8924710000 8924270000 8924460000 8924710000 8924270000 8448940000 8448940000 Interface/ signal Mounting Connection system Protected Discharge Operating max. wires capacity current voltage Protection device Part No. Arrestor ARCNET (Plus) ASI ASI BITBUS BLN (Building Level Network) BLN (Building Level Network) CAN-Bus CANopen C-BUS C-Bus (Honeywell) CC-LINK Data Highway (Plus), DH+ DATEX P Device Net DeviceNet DIN measurement bus Dupline / Miniplex on DIN-rail on DIN-rail on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals 2 2 4 4 2 8/20 s 2 kA 2 kA 5 kA 5 kA 5 kA Imax. 16 A 16 A 0.45 A 0.45 A 0.45 A DC - - 15 V 15 V 28 V PU III R 48 V PU III R 24 V VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 1CL 24 V DC 0.5 A 8860350000 8860360000 8924460000 8924710000 8924270000 8924460000 8924710000 8924270000 8924480000 8924730000 8924290000 on DIN-rail, separable Screw terminals 4 5 kA 0.45 A 28 V VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable Screw terminals Tension clamp terminals Screw terminals Tension clamp terminals Screw terminals Screw terminals Tension clamp terminals Tension clamp terminals Screw terminals Screw terminals Screw terminals 4 2 4 2 4 4 2 2 4 2 2 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 0.45 A 0.3 A 0.45 A 0.3 A 0.45 A 0.45 A 0.3 A 0.3 A 0.45 A 0.45 A 0.45 A 15 V 12 V 15 V 5V 15 V 15 V 24 V 12 V 15 V 15 V 28 V VSPC 2CL HF 12 V DC MCZ OVP HF 12 V 0.3 A VSPC 2CL HF 12 V DC MCZ OVP HF 5 V 0.3 A VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC MCZ OVP HF 24 V 0.3 A MCZ OVP HF 12 V 0.3 A VSPC 2CL HF 12 V DC VSPC 1CL 12 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A 8924460000 8948610000 8924460000 8948620000 8924460000 8924460000 8948600000 8948610000 8924460000 8924450000 8924480000 Bus systems 0.45 A 0.45 A 0.5 A 0.5 A Part No. Direct earthing base Part No. Indirect earthing base 8924710000 8924270000 8924710000 8924270000 8924710000 8924270000 8924710000 8924270000 8924710000 8924270000 8924730000 8924290000 8924730000 8924290000 59 Quick Selection Guide Bus systems 60 Interface/ signal Mounting Connection system Protected Discharge Operating max. wires capacity current voltage Protection device Part No. Arrestor E1 EIB (European Installation Bus) ET 200 ET 200 Ethernet Cat.6 Ethernet Cat.5 Ethernet Cat.6 Ethernet Cat.6 FIPIO / FIPWAY Genius I/O Bus HDSL IEC-BUS Interbus Interbus-Inline I/O LONTM (Works) LONTM TP/XF 78 LONTM TP/XF 78 LONTM-Bus LRE networks LUXMATE-Bus M-Bus M-Bus (remote reading of meter) MOD-Bus MODBUS(-PLUS) MPI Bus N1 LAN N2 Bus (P-Bus) P-NET Procontic CS31 Procontic CS31 Procontic T200 Profibus (Profibus DP) Profibus DP (FMS) Profibus DP (FMS) Profibus DP/FMS Profibus PA Profinet Process Bus, Panel Bus PSM-EG-RS422... PSM-EG-RS485... RACKBUS SDLC SDSL SecuriLan-LONTM-Bus SINEC L1 Sinec L2 SINEC L2 DP Sinec L2 DP/ Profibus DP TCP / IP Token Ring Token Ring TP/FTT 10+TP/LPT10 U-BUS on DIN-rail, separable on DIN-rail, separable Screw terminals Screw terminals 4 2 8/20 s 5 kA 5 kA Imax. 0.45 A 0.45 A DC 6.4 V 28 V VSPC 2CL HF 5 V DC VSPC 1CL 24 V DC 0.5 A Part No. Part No. Direct Indirect earthing earthing base base 8924430000 8924710000 8924270000 8924480000 8924730000 8924290000 on DIN-rail, separable on DIN-rail, compact Plug-in adapter Adapter plug Adapter plug Adapter plug on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable on DIN-rail, compact on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable Screw terminals Tension clamp terminals RJ 45 connection M12 RJ 45 connection RJ 45 connection Screw terminals Screw terminals Tension clamp terminals Screw terminals Tension clamp terminals Tension clamp terminals Screw terminals Tension clamp terminals Tension clamp terminals Tension clamp terminals Screw terminals Screw terminals Tension clamp terminals Screw terminals 2 2 4 4 4 4 4 4 2 4 2 2 4 2 2 2 4 4 2 2 5 kA 5 kA 10 kA 10 kA 10 kA 10 kA 5 kA 5 kA 5 kA 5 kA 5 kA 10 kA 5 kA 10 kA 0,1 kA 5 kA 5 kA 5 kA 5 kA 5 kA 0.45 A 0.3 A 1A 0.45 A 0.45 A 0.3 A 0.45 A 0.3 A 1.25 A 0.45 A 0.5 A 16 A 0.3 A 0.45 A 0.45 A 0.3 A 0.45 A 28 V 5V 48 V 30 V 48 V 48 V 6.4 V 15 V 24 V 6.4 V 5V 53 V 85 V 28 V 14 V 12 V 6.4 V 28 V 24 V 28 V VSPC 1CL 5 V DC 0.5 A MCZ OVP HF 5 V 0.3 A V DATA Cat.6 JACKPAC(R) Ethernet Cat.5 M12 JACKPAC(R) Ethernet Cat.6 IP20 JACKPAC(R) Ethernet Cat.6 IP67 VSPC 2CL HF 5 V DC VSPC 2CL 12 V DC 0.5 A MCZ OVP HF 24 V 0.3 A VSPC 2CL HF 5 V DC MCZ OVP HF 5 V 0.3 A MCZ OVP CL 48 V 1.25 A VSPC 1CL 48 V AC 0.5 A MCZ OVP CL 24 V 0.5 A MCZ OVP LON Bus MCZ OVP HF 12 V 0.3 A VSPC 2CL HF 5 V DC VSPC 2CL HF 24 V DC MCZ OVP HF 24 V 0.3 A VSPC 1CL 24 V AC 0.5 A 8924420000 8948620000 1348590000 8805570000 8805550000 8805560000 8924430000 8924440000 8948600000 8924430000 8948620000 8449040000 8924520000 8448920000 8473470000 8948610000 8924430000 8924510000 8948600000 8924500000 on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, compact on DIN-rail, separable on DIN-rail, separable Tension clamp terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Tension clamp terminals Screw terminals Screw terminals Screw terminals Screw terminals Tension clamp terminals Tension clamp terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Tension clamp terminals Screw terminals Screw terminals 2 4 4 4 2 2 4 2 4 4 2 4 4 4 2 2 2 4 4 4 4 4 4 2 4 2 4 2 5 kA 5 kA 5 kA 5 kA 5 kA 2 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 6 kA 10 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 6 kA 0.3 A 0.45 A 0.45 A 0.45 A 0.45 A 16 A 0.45 A 0.45 A 0.45 A 0.45 A 0.3 A 0.45 A 0.45 A 0.45 A 1.5 A 1.25 A 0.3 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.3 A 0.45 A 1.5 A 5V 15 V 6.4 V 6.4 V 6.4 V - 15 V 15 V 15 V 15 V 5V 6.4 V 6.4 V 15 V 12 V 53 V 5V 15 V 15 V 15 V 6.4 V 15 V 185 V 15 V 6.4 V 5V 6.4 V 12 V MCZ OVP HF 5 V 0.3 A VSPC 2CL HF 12 V DC VSPC R485 2 CH VSPC 2CL HF 5 V DC VSPC 2SL 5 V DC 0.5 A PU III R 24 V VSPC 2CL HF 12 V DC VSPC 1CL 12 V DC 0.5 A VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC MCZ OVP HF 5 V 0.3 A VSPC R485 2 CH VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC RS485 MCZ OVP CL 48 V 1.25 A MCZ OVP HF 5 V 0.3 A VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC VSPC Uko VSPC 1CL 12 V DC 0.5 A VSPC 2CL HF 5 V DC MCZ OVP HF 5 V 0.3 A VSPC 2CL HF 5 V DC RS485 8948620000 8924460000 8924710000 8924670000 8924710000 8924430000 8924710000 8924210000 8924720000 8860360000 8924460000 8924710000 8924450000 8924730000 8924460000 8924710000 8924460000 8924710000 8948620000 8924670000 8924710000 8924430000 8924710000 8924460000 8924710000 9454930000+8007871001 8449040000 8948620000 8924460000 8924710000 8924460000 8924710000 8924460000 8924710000 8924430000 8924710000 8924460000 8924710000 8924660000 8924710000 8924450000 8924730000 8924430000 8924710000 8948620000 8924430000 8924710000 9454930000+8007871001 on DIN-rail, compact on DIN-rail, compact on DIN-rail, compact on DIN-rail, compact on DIN-rail, separable Tension clamp terminals Tension clamp terminals Tension clamp terminals Tension clamp terminals Screw terminals 2 2 2 2 4 5 kA 0.5 kA 5 kA 10 kA 5 kA 0.3 A 16 A 0.3 A 1.25 A 2A 5V 27 V 5V 53 V 72 V MCZ OVP HF 5 V 0.3 A MCZ OVP TAZ 24 V MCZ OVP HF 5 V 0.3 A MCZ OVP CL 48 V 12.5 A VSPC GDT 2 CH 90 V 20 kA 8948620000 8449160000 8948620000 8449040000 8924570000 8924740000 8924300000 8924730000 8924290000 8924710000 8924270000 8924710000 8924270000 8924710000 8924270000 8924730000 8924290000 8924710000 8924270000 8924710000 8924270000 8924730000 8924290000 8924270000 8924270000 8924270000 8924280000 8924270000 8924290000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924290000 8924270000 8924270000 Quick Selection Guide Product quick selection, information technology Telecommunications Interface/ signal Mounting Connection system Protected Discharge Operating max. wires capacity current voltage ADSL ADVANT HDSL SHDSL T-DSL Telephone analog TTY, 0(4) - 20 mA (Uk0-Bus) V.35 VDSL X.21/X.24 X.25/X.31 on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable on DIN-rail, separable Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals 4 4 4 4 4 4 4 4 4 4 4 4 8/20 s 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA Imax. 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A 0.45 A DC 185 V 6.4 V 185 V 185 V 185 V 185 V 28 V 185 V 6.4 V 185 V 15 V 15 V Protection device Part No. Arrestor VSPC Uko VSPC 2CL HF 5 V DC VSPC Uko VSPC Uko VSPC Uko VSPC Uko VSPC 2CL 24 V DC 0.5 A VSPC Uko VSPC 2CL HF 5 V DC VSPC Uko VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC 8924660000 8924430000 8924660000 8924660000 8924660000 8924660000 8924470000 8924660000 8924430000 8924660000 8924460000 8924460000 Part No. Direct earthing base 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 8924710000 Part No. Indirect earthing base 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 8924270000 61 Certification SIL certification for VSSC and VSPC 62 63 Lightning and surge protection for control and instrumentation signals ON SU RG EP RO TEC TI 0 1 2 3 4 5 MSR breakdowns or malfunctions can lead to exorbitant costs. As the standards covering low control voltages do not specify many parameters, the use of surge protection, apart from lightning protection zoning concepts, has to be classified according to type of signal, application circuit and the anticipated interference voltage phenomena. Types of interference voltage SU RG EP RO TEC TI ON Electrical system SU RG EP RO TEC TI ON Lightning and surge protection for control and instrumentation signals Basic classification The current scope of automation technology has resulted in a wide range of applications for surge protection in the field of instrumentation and control engineering. One important prerequisite is the consistent use of coordinated surge protection in all sections of the plant or building. In industry, instrumentation and control systems are important areas and Transient surges coupled into a system via one or more coupling mechanisms occur as normal- or common-mode interference. These are measured as longitudinal or transverse voltages and, depending on the circuit, designated as symmetrical or asymmetrical voltages. (For further information see the "Principles" chapter.) push pull interference Icommon mode Ipush-pull Z /2 Uunbalanced. 1 Icommon mode Ucommon mode Z /2 Usym. Usym. Upush-pull Uunbalanced 1 Z /2 Z /2 Ipush-pull Uasym. Uunbalanced 2 transverse voltage Ucommon mode Uasym. Uunbalanced 2 longitudinal voltage Common-mode interference (asymmetrical interference): Common-mode voltage between conductor and reference potential. (earth)/mainly caused by capacitive coupling (electrical field) 64 Binary signals SL (symmetrical loop) These are two-wire signals with a common reference potential which are required by, for example, by switches, PLC switch outputs, photoelectric barriers, position sensors, solenoid valves, warning lamps, PLC inputs, etc. Normally, these signals have a common reference potential that can be either connected or not connected to earth potential, depending on the type of protection. The coupled transient interference is primarily common-mode interference. Analog signals CL (current loop) common mode interference Upush-pull Types of signal Normal-mode interference (symmetrical interference): Normal-mode voltage between supply and return conductor load and interference source connected in series, e.g. inductive (magnetic field) or conductive coupling (common impedance) Measuring circuits are normally designed as two-wire current loops or voltage signals without a common reference potential, like the 0(4)...20 mA current loop. The coupled transient interference is primarily normal-mode interference. For temperature measurements with the PT100 measuring shunt in the three-wire version, the voltage drop at the shunt is measured via the third wire. This must be included in the system of protection. The PT100 measuring shunt is also available in a four-wire version in which the voltage drop at the shunt is measured via the two additional lines without additional line losses in the PT100 measuring circuit. The coupled transient normal-mode interference occurs between the various wires. Lightning and surge protection for control and instrumentation signals Essential information for users can be found in the IEC 61643-22 standard (application standard for measurement and control signals) and in the IEC 62305-4 standard (application standard for installing internal lightning protection). It is important to determine which protection category is required. There are divisions for D1 (lightning protection), C2 (surge protection / overvoltage protection) and C1 (end device protection). These categories or classes are specified for the following products. All products were subjected to a test in accordance with product standard IEC 61643-21:2008. Binary signals Protection for binary signals connected to earth potential. 4 1 Two-wire, usually with common reference potential, e.g. signals from binary sensors, actuators and indicators such as limit switches, probes, position sensors, photoelectric barriers, contactors, solenoid valves, warning lamps. 2 5 1 4 3 PROTECTED 2 5 Protection for binary signals not connected to earth potential. 6 TS 1 UNPROTECTED PROTECTED 2 1 6 TS UNPROTECTED PROTECTED 2 5 Deratingkurve TS I/A3 1 0,8 UNPROTECTED 0,6 0,6 Page 84 Page 88 Page 92 VSPC GDT VSPC MOV VSPC TAZ VSPC UK0 Page 94 Page 96 Page 98 Page 100 VSSC6 SL LD VSSC6 TR SL LD VSSC6 SLFG LD VSSC6 TR SLFG LD Page 126 Page 128 Page 126 Page 128 VSSC6 MOV VSSC6 TR MOV VSSC6 GDT VSSC6 TR GDT VSSC6 TAZ VSSC6 TR TAZ VSSC6 RTD Page 130 Page 132 Page 134 Page 136 Page 138 Page 138 Page 142 VSSC4 SL VSSC4 SL FG VSSC4 MOV VSSC4 GDT VSSC4 TAZ VSSC4 RC Page 148 Page 148 Page 150 Page 152 Page 154 Page 156 4 5 4 3 Type VSPC 2SL VSPC 4SL VSPC 3/4 6 TS UNPROTECTED 3 Type 6 PROTECTED 0,6 0,6 0,5 Protection for two-, threeand four-wire versions. 0,4 I/A 0,2 1 0,4 Deratingkurve 0 0,8 -40 C 0,6 0,6 0 C 0,6 15 C 0,6 TU 70 C 42,5 C 0,5 0,4 0,4 0,2 0 -40 C 0 C 15 C TU 70 C 42,5 C Type Analog signals 11 Two-, three- and four-wire versions without common reference potential. GND 12 7 8 9 10 GND 3 4 TS 5 6 1 2 unprotected protected Komplettmodul direkte Erdung Signals from current loops (analog measurements from sensors over long distances), 4...20 mA, 0...20 mA, etc., e.g. level measurements. 11 12 7 7 3 9 5 3 TS 1 unprotected 2 protected 12 12 8 9 7 10 GND 8 TS OK FAULT TS TS protected Komplettmodul indirekte Erdung 51 protected 12 Komplettmodul direkte Erdung, mit Fernmeldung 1 unprotected 2 protected 7 8 12 9 10 GND 11 Komplettmodul direkte Erdung 11 7 GND 9 3 7 5 9 3 GND 12 10 GND 4 X2 X1 6 8 4 10 GND 26 4 62 unprotected 11 GND X2 X1 8 4 10 GND 6 11 7 5 7 3 GND 9 1 5 unprotected 3 OK FAULT 12 8 OK FAULT 6 GND 10 4 X2 X1 26 TS TS 5 1 3 unprotected TS protected Komplettmodul indirekte Erdung, mit Fernmeldung 1 5 unprotected Komplettmodul indirekte Erdung 1 unprotected 11 X2 X1 10 GND 4 8 4 62 protected 2 12 protected Komplettmodul direkte Erdung, mit Fernmeldung 7 11 GND 9 Page 146 Page 146 26 11 9 GND 11 3 VSSC4 CL VSSC4 CL FG protected Komplettmodul direkte Erdung, mit Fernmeldung GND Page 122 Page 124 Page 122 Page 140 Page 141 Page 140 4 TS 15 unprotected Komplettmodul direkte Erdung Signals from voltage sensors (analog measurements from sensors over short distances), 0...10 V, PT100, etc., e.g. temperature measurements. VSSC6 CL VSSC6 TR CL VSSC6 CLFG VSSC6 RS485 VSSC6 RS485 DP VSSC6 RS232 10 12 GND OK FAULT GND Page 74 Page 78 Page 82 Page 102 8 9 11 GND VSPC 1CL VSPC 2CL VSPC 1CL PW VSPC RS485 8 12 10 GND 65 VARITECTOR SPC - Overview VARITECTOR SPC Pluggable surge protection for the measurement and control industry VARITECTOR SPC Weidmuller's VARITECTOR SPC pluggable surge protection is remarkable for its combination of extremely high protective functionality and compact dimensions. It is suited for use in measurement and control circuits. The size is made possible by the seletion of INSTA dimensions, with a width of 17.8 mm (1TE). Two versions are available: *VSPC: a surge protector with no monitoring function *VSPC R: a surge protector with monitoring function The base components are plugged in to form a direct earthing contact via the mounting rail. This saves you time when making the connection. The VARITECTOR SPC series is optimally designed for compact installations in process automation, industrial automation and building automation. The two-stage surge-protection base components are equipped with gas discharge tubes, suppressor diodes (TVS) and decoupling components. Individual protective components (such as gas-filled spark gaps, varistors and suppressor diodes) supplement this product line. IEC 62305 requires that a periodic inspection of surge protection products be conducted. The functionality of all VARITECTOR SPC modules can be tested using testing equipment (such as the V-TEST Basic) that is available separately. The VARITECTOR SPC R modules also feature an internal monitoring function. The green LED signals when the protection function is ready. The red LED signals an error. 66 Up to ten modules can be wired together in succession. The modules alert an evaluative module (the VSPC CONTROL UNIT) in the event of an error. VARITECTOR SPC series surge protection is available with rated voltages of 5 V, 12 V, 24 V, 48 V and 60 V. The product's voltage level is color-coded on the pluggable arrester. An earthing contact is established by snapping onto an earthed TS 35 rail. The TS 35 must be earthed in order to ensure safe power discharging via the terminals of up to 20 kA (8/20 s) and 2.5 kA (10/350 s). The rail must be screwed onto the earthed mounting plate for reasons of EMC. In order to optimise the protective function, a PE-contact connection should be made over the VSPC module every 60 cm for equipotential bonding. The pluggable protective element can be pulled out during operations without interrupting the measurement circuit. A testing instrument, available as a Weidmuller accessory, allows you to test the protective element in compliance with the IEC 62305-3 directive. The accessory also includes a simple mechanism for applying the wire shield. Overview of model types A VARITECTOR SPC (VSPC) consists of a pluggable component and a separate base component (VSPC BASE). Explanation of terms: CL = current loop / analog signals SL = symmetric loop - for binary signals VSPC 2CL VSPC 2CL (CL = current loop) is a two-stage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC 2CL limits the surge voltage within two analog signal circuits (such as for current loops). This pluggable component can be inserted into the base (VSPC BASE 2CL). The base (VSPC BASE FG 2CL) is used when working with signal circuits which are not earthed. The VSPC 2CL HF is used in order to avoid influencing high-frequency signal circuits (this also includes the VSPC RS485 and the VSPC UK0). This protective combination is also inserted into the base mentioned above. Monitoring function The VSPC 2CL R products feature monitor and alert functions. As well as the alert function, there are two channels available for current loops in a single housing. The special VSPC BASE 2CL R and SPC BASE 2CL FG R bases VARITECTOR SPC - Overview transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. VSPC 1CL The VSPC 1CL is a two-stage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC 1CL limits the surge voltage within one analog signal circuit (such as for current loops). This pluggable component can be inserted into the base (VSPC BASE 1CL). The base (VSPC BASE FG 1CL) is used when working with signal circuits which are not earthed. Monitoring function The VSPC 1CL R products feature monitor and alert functions. All channels remain despite the alert function. The special VSPC BASE 1CL R and VSPC BASE 1CL FG R bases transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. VSPC 4SL The VSPC 4SL is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current path to the PE. This VSPC 4SL limits the surge voltage within four binary signal circuits (such as for alert contacts). This pluggable component can be inserted into the base (VSPC BASE 4SL). The base (VSPC BASE FG 4CL) is used when working with signal circuits which are not earthed. Monitoring function The VSPC 4SL R products feature monitor and alert functions. Even with the alert function, there are still channels available for the four binary signal circuits in a single housing. The special VSPC BASE 4SL R base transfers the alert function to a 2-pole screw/plug-in connection in the base and to the VSPC CONTROL UNIT. The VSPC 3/4WIRE is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current path to the GND. This VSPC 3/4WIRE limits the surge voltage within four temperature-measurement circuits (such as for DMS or PT100/100 sensors). For non-earthed measurement circuits, we recommend using the base (VSPC BASE FG 4CL). VSPC GDT VSPC 2SL The VSPC 2SL is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current path to the PE. This VSPC 2SL limits the surge voltage within two binary signal circuits (such as for alert contacts). This pluggable component can be inserted into the base (VSPC BASE 2SL). The base (VSPC BASE 2CL FG) is used when working with signal circuits which are not earthed. VSPC MOV 2CH , VSPC TAZ 2CH and VSPC GDT 2CH Four cables can be protected with the 2CH modules. By wiring the connections differently, either two novoltage signal lines or four binary signal lines can be protected. Two three-pole gas discharge tubes (GDTs) are used for the VSPC GDT 2CH. This universal protective circuitry limits the voltage between the signal lines and also between each signal line and the PE. Monitoring function The VSPC 2SL R products feature monitor and alert functions. Even with the alert function, there are still channels available for the two binary signal circuits in a single housing. The special VSPC BASE 2SL R base transfers the alert function to a 2-pole screw/plug-in connection in the base and to the VSPC CONTROL UNIT. VSPC 3/4WIRE 67 VARITECTOR SPC - Overview Applications VSPC TAZ VSPC MOV The VSPC MOV 2CH and TAZ 2CH offer one-stage protection with a varistor (MOV) or suppressor diode (TAZ or TVS) between the current paths. This makes it possible to protect a no-voltage (floating) signal circuit. Two binary signal circuits can also be protected if terminals 1 and 7 are assigned to GND / PE. These VSPC pluggable components are inserted into the base (VSPC BASE 2/4CH). The base (VSPC BASE 2/4CH FG) is used when working with signal circuits which are not earthed. 24 V VSPC 1CL PW VSPC 1CL PW (power and signal 1CL) offers combined protection that is suitable for the 24 V DC power supply and the current loops within a device. This VSPC protects sensors with an additional 24 V DC. 68 VSPC RS422/485 The VSPC RS485 is a two-stage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC RS485 limits the surge voltage within two high-frequency signal circuits. This pluggable component can be inserted into the base (VSPC BASE 2CL). The base (VSPC BASE FG 2CL) is used when working with signal circuits which are not earthed. Monitoring function The VSPC RS485 R product features monitoring and alert functions. Even with the alert function, there are still two channels available for current loops in a single housing. The special VSPC BASE 2CL R and VSPC BASE 2CL FG R bases transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. Earthing unit and test plug The earthing unit can be used during installation to short out the connected wires to earth. The earthing unit is swapped out for a VSPC pluggable component before the initial commissioning. The test plug has 2.3-mm sockets. These sockets can be used by a meter to check the connected measurement circuit. The pluggable INSTA housing was created in compliance with DIN 43880. It consists of a lower section (the VSPC BASE) and a pluggable component (the VSPC). The VSPC BASE is made from black PA6.6 V0. The pluggable component is made from red PA6.6 V0. The temperature range is from -40 C to + 70 C. The VSPC series has been tested to comply with IEC 61643-21 04/2008 and EN 61643-21. Modules were tested with categories C1, C2 and C3: with quick-rising edges with up to 300 pulses. Category D1 describes high power testing (10/350 s lightning protection), so that the VSPC can be used according to IEC 62305-4. The base and pluggable components are color coded according to the voltage level. This makes installation easier. Color coding The pluggable components transfer their coding to the base element when they are plugged in for the first time. The voltage levels are also labelled with colored Dekafix markers applied to the VSPC pluggable component. This gives you a better overview within the electrical cabinet. Voltage level 12 V 24 V Binary 24 V Analog 48 V 60 V Special function Color green blue yellow red violet white VARITECTOR SPC - Overview Test possibility / V-TEST Because the modules are pluggable, it is possible to test the VSPC visually or by using a V-TEST testing device. The VSPC can be easily tested; the user needs only to insert the VSPC pluggable component into the V-TEST. The result is then shown on the display. The VSPC R modules also feature an internal monitoring function for the arrester. An error is the displayed at the defective module. The VSPC CONTROL UNIT can then transfer an alert to the control room. Reoccurring tests / V-TEST Monitoring The IEC 62305-3 requires testing and maintenance for lightning protection systems. This includes the testing of the arresters used in the system. Class of protection I II III/IV Interval for complete testing 2 years 4 years 6 years Installation Remote error diagnostics Interval for visual inspection 1 year 2 years 3 years Caution! These periodic inspections may be extended with stricter requirements pertaining to special applications or regions. VSPC R When the VSPC module labelled "R" is inserted into the corresponding "R" base component, it is then possible to use the outage alert function via a two-pole plug. This screw/plug-in connection has a clamping range from 0.5 to 1.5 mm. The wire stripping length is 6 to 6.5 mm. A screwdriver with a 2-mm blade width is used to turn the screw. The VSPC Rs are connected in succession to the VSPC CONTROL UNIT evaluative module. Up to ten VSPC Rs can be connected in succession to the VSPC CONTROL UNIT. The evaluative module is supplied with 24 V DC. It is then responsible for the switching and for the voltage supply to the VSPC modules. A no-voltage (floating) CO contact can then be used to alert in the event of an outage. The error on the module, with the LED changing color from green to red. An automatic reset is carried out by the VSPC CONTROL UNIT within one minute after the failed VSPC pluggable component is replaced. The VSPC series is appropriate for protecting signal circuits. In order to achieve a complete protective strategy for the facility, the power feed must be protected against Type II surge voltages (for example, by using our VPU II series). For existing lightning protection facilities, Type I protection must be used (for example, by using our VPU I series). Type II protection (for example, our VPU II) is sufficient when there is no lightning protection in place. Fusing The VSPC surge protection modules are designed so that they are decoupled between the individual protective stages. The following must be observed when providing fuse protection externally: * Max. rated current * Deratings curve * Type of installation * Application l 3 meter 14 11 12 X1 X2 X1 X2 X1 X2 X1 X2 2 4 6 2 4 6 2 4 8 10 12 8 10 12 8 10 12 6 VSPC CONTROL UNIT VSPC .... ............R VSPC .... ............R U C : .......... I N : .......... I SN : .......... U P ......... IP 20 OK VSPC .... ............R U C : .......... I N : .......... I SN : .......... U P ......... IP 20 U C : .......... I N : .......... I SN : .......... U P ......... IP 20 FAULT U N = 24V U C = 31V IP 20 8972270000 24V XXXXXX0000 0V VSPC CONTROL UNIT XXXXXX0000 7 9 11 7 9 11 1 3 5 1 3 5 XXXXXX0000 7 9 11 1 3 5 n x VSPC...R n 10 69 VARITECTOR SPC - Overview Discharge capacity General technical data Accessories Testing is conducted using voltage and current pulses according to the IEC 61643-21 standard concerning surge protection in networks which process signals. Storage temperature -40 C...+80 C Operating temperature: -40 C...+70 C Air humidity 5%...96% RH with no condensation Material: V0, IP 20 Markers The VSPC BASE lower section can be labelled with Dekafix-5 markers. The VSPC pluggable modules are color coded with Dekafix-5 markers according to their rated voltage. Cate- Testing gory pulse C1 Quick rising edge Surge voltage 0.5-2 kV with 1.2/50 s Surge current 0.25-1 kA with 8/20 s Pulse Type 300 Surge voltage arrester C2 Quick rising edge 2-10 kV with 1.2/50 s 1-5 kA with 8/20 s 10 Surge voltage arrester C3 Quick rising edge 1 kV with 1 kV/s 300 10-100 A with 10/10.000 s Surge voltage arrester D1 High power 1 kV 0.5-2.5 kA with 10/350 s Arrester for lightning current and surge voltages 2 Category C reflects the interference pulses with quick-rising edges and minimised power. Category D uses quick-rising edges and high power to detail the interference pulses. This energy simulates the high-power load that stems from coupled partial lightning currents. Connection: screw connection screwdriver blade: 0.6 x 3.5 DIN 5264 (for example, 0.6x3.5x200, part no. 9010110000) rated torque: 0.5 Nm max. torque: 0.8 Nm stripping length: 7 mm solid: 0.5...4 mm flexible: 0.5...2.5 mm wire-end ferrule with plastic collar: 0.5...2.5 mm Remote signalling connection: screw connection screwdriver blade: 0.4 x 2.0 DIN 5264 (for example, SD 0.4x2.0x60, part no. 9037160000) max. torque: 0.2 Nm stripping length: 6...6.5 mm solid: 0.5...1.5 mm Dimensions Height: 90 mm Height: with remote signalling contact: 98 mm Depth: 69 mm Width: 17.8 mm Shield connection EMC SET, part no. 1067470000 The EMC set consists of a connection component with shielding and a cable tie covered with shielding braid. The RT-1 cable tie tool (part no. 1296000000) can be used to fasten the cable ties professionally. V-TEST Testing device for functional tests of the pluggable VSPC, PU II and PU I surge protection. VSPC Ground This plug is attached to unused wires in the base element, so that all wires have the same potential. VSPC TEST CONNECTOR This plug-in component is used for measuring the signal circuits. Testing is very easy when using sockets 2.3. 70 VARITECTOR SPC - Overview VARITECTOR SPC - Choice of device depending on the interface Interface Pluggable arrestor 0(4) ... 20 mA 0(4) ... 20 mA 0 ... 10 V 0 ... 10 V ADSL ADVANT ARCNET (Plus) ASI BITBUS BLN (Building Level Network) CAN-Bus C-BUS CC-LINK Data Highway (Plus), DH+ Datex-P DeviceNet DIN measurement bus Dupline/Miniplex EIB (European Installation Bus) ET 200 E1 FIPIO/FIPWAY Genius I/O Bus Hart HDSL IEC-BUS ISDN Basic connection (Uk0-Bus) Cathodic corrosion prevention LONTM (Works) LRE networks LUXMATE-Bus M-Bus (Remote readout of counter) MODBUS(-PLUS) MPI-Bus N1 LAN N2 Bus P-NET Procontic CS31 Procontic T200 Profibus DP (FMS) VSPC 2CL 24 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A VSPC 2CL 24 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A VSPC Uko VSPC 2CL HF 5 V DC VSPC RS485 2ch PU III R 48 V DC PU III R 24 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 1CL 24 V DC 0.5 A VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC Part No. Arrestor 8924470000 8924480000 8924470000 8924480000 8924660000 8924430000 8924670000 8860350000 8860360000 8924460000 8924460000 8924480000 8924460000 8924460000 8924460000 8924460000 Part No. Base 8924710000 8924730000 8924710000 8924730000 8924710000 8924710000 8924710000 Part No. Base floating ground (FG) 8924270000 8924290000 8924270000 8924290000 8924270000 8924270000 8924270000 Pluggable arrestor with operation message (R) VSPC 2CL 24 V DC 0.5 A R VSPC 1CL 12 V DC 0.5 A R VSPC 2CL 24 V DC 0.5 A R VSPC 1CL 12 V DC 0.5 A R Part No. Arrestor 8951480000 8951540000 8951480000 8951540000 Part No. Base 8951710000 8951730000 8951710000 8951730000 Part No. Base floating ground (FG) 8951720000 8951740000 8951720000 8951740000 8951680000 8951670000 8860350000 8860360000 8951470000 8951470000 8951540000 8951690000 8951690000 8951690000 8951690000 8951710000 8951710000 8951720000 8951720000 8924270000 8924270000 8924290000 8924270000 8924270000 8924270000 8924270000 VSPC 2CL HF 5 V DC R VSPC RS485 2ch R PU III R 48 V DC PU III R 24 V DC VSPC 2CL 12 V DC 0.5 A R VSPC 2CL 12 V DC 0.5 A R VSPC 1CL 12 V DC 0.5 A R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R 8924710000 8924710000 8924730000 8924710000 8924710000 8924710000 8924710000 8951710000 8951710000 8951730000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951740000 8951720000 8951720000 8951720000 8951720000 VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 1CL 12 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A 8924460000 8924460000 8924460000 8924450000 8924480000 8924710000 8924710000 8924710000 8924730000 8924730000 8924270000 8924270000 8924270000 8924290000 8924290000 VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R VSPC 1CL 12 V DC 0.5 A R VSPC 1CL 24 V DC 0.5 A R 8951690000 8951690000 8951690000 8951540000 8951550000 8951710000 8951710000 8951710000 8951730000 8951730000 8951720000 8951720000 8951720000 8951740000 8951740000 VSPC 1CL 5 V DC 0.5 A VSPC Uko VSPC 2CL HF 5 V DC VSPC 2CL HF 5 V DC VSPC 2CL 12 V DC 0.5 A VSPC 1CL 24 V DC 0.5 A VSPC Uko VSPC 2CL HF 5 V DC VSPC Uko 8924420000 8924660000 8924430000 8924430000 8924440000 8924480000 8924660000 8924430000 8924660000 8924730000 8924710000 8924710000 8924710000 8924710000 8924730000 8924710000 8924710000 8924710000 8924290000 8924270000 8924270000 8924270000 8924270000 8924290000 8924270000 8924270000 8924270000 VSPC 1CL 5 V DC 0.5 A R 8951530000 8951730000 8951740000 VSPC 2CL HF 5 V DC R VSPC 2CL HF 5 V DC R VSPC 2CL 12 V DC 0.5 A R VSPC 1CL 24 V AC 0.5 A R 8951680000 8951680000 8951470000 8951560000 8951710000 8951710000 8951710000 8951730000 8951720000 8951720000 8951720000 8951740000 VSPC 2CL HF 5 V DC R 8951680000 8951710000 8951720000 VSPC GDT 2ch 90 V 20 kA 8924570000 8924740000 8924300000 VSPC 1CL 48 V AC 0.5 A VSPC 2CL HF 5 V DC VSPC 2CL HF 24 V DC VSPC 1CL 48 V AC 0,5 A 8924520000 8924430000 8924510000 8924520000 8924730000 8924710000 8924710000 8924730000 8924290000 8924270000 8924270000 8924290000 VSPC 2CL HF 5 V DC R VSPC 2CL HF 24 V DC R VSPC 1CL 24 V DC 0.5 A R 8951680000 8951700000 8951550000 8951710000 8951710000 8951730000 8951720000 8951720000 8951740000 VSPC 2CL HF 12 V DC VSPC RS485 2ch VSPC 2CL HF 5 V DC VSPC 2SL 5 V DC 0.5 A VSPC 2CL HF 12 V DC VSPC 1CL 12 V DC 0.5 A VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 12 V DC 8924460000 8924670000 8924430000 8924210000 8924460000 8924450000 8924460000 8924460000 8924430000 8924460000 8924460000 8924710000 8924710000 8924710000 8924720000 8924710000 8924730000 8924710000 8924710000 8924710000 8924710000 8924710000 8924270000 8924270000 8924270000 8924280000 8924270000 8924290000 8924270000 8924270000 8924270000 8924270000 8924270000 VSPC 2CL HF 12 V DC R 8951690000 VSPC 2CL HF 5 V DC R VSPC 2SL 5 V DC 0.5 A R VSPC 2CL HF 12 V DC R VSPC 1CL 12 V DC 0.5A R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 5 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 12 V DC R 8951680000 8951610000 8951690000 8951540000 8951690000 8951690000 8951680000 8951690000 8951690000 8951710000 8951710000 8951710000 8951770000 8951710000 8951730000 8951710000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951780000 8951720000 8951740000 8951720000 8951720000 8951720000 8951720000 8951720000 8860360000 8951690000 8951690000 8951680000 8951690000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951720000 8951690000 8951670000 8951690000 8951690000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951720000 8951540000 8951730000 8951740000 8951680000 8951680000 8951670000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951480000 8951710000 8951720000 8951680000 8951690000 8951690000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 Process-Bus Panel-Bus 8924550000 8924740000 8924300000 PT100 VSPC 3/4WIRE 24 V DC P-Bus PU III R 24 V DC 8860360000 PU III R 24 V DC PSM-EG-RS422... VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R PSM-EG-RS485... VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R RACKBUS VSPC 2CL HF 5 V DC 8924430000 8924710000 8924270000 VSPC 2CL HF 5 V DC R VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R RS422A, V.11, X.27, RS423A RS449 VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R RS485 VSPC RS485 2ch 8924670000 8924710000 8924270000 VSPC RS485 2ch R RS232-C/V.24 VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R SDLC VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R SDSL VSPC Uko 8924660000 8924710000 8924270000 SecuriLan-LONTM-Bus VSPC 1CL 12 V DC 0.5 A 8924450000 8924730000 8924290000 VSPC 1CL 12 V DC 0.5 A R SHDSL VSPC Uko 8924660000 8924710000 8924270000 SINEC L1 VSPC 2CL HF 5 V DC 8924430000 8924710000 8924270000 VSPC 2CL HF 5 V DC R SINEC L2 DP VSPC 2CL HF 5 V DC 8924430000 8924710000 8924270000 VSPC 2CL HF 5 V DC R Profibus DP VSPC RS485 2ch 8924670000 8924710000 8924270000 VSPC RS485 2ch R T-DSL VSPC Uko 8924660000 8924710000 8924270000 Telephone analog VSPC Uko 8924660000 8924710000 8924270000 TTY, 0(4) - 20 mA VSPC 2CL 24 V DC 0.5 A 8924470000 8924710000 8924270000 VSPC 2CL 24 V DC 0.5 A R U-BUS VSPC GDT 2ch 90 V 20 kA 8924570000 8924740000 8924300000 VDSL VSPC Uko 8924660000 8924710000 8924270000 V.35 VSPC 2CL HF 5 V DC 8924430000 8924710000 8924270000 VSPC 2CL HF 5 V DC R X.21/X.24 VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R X.25/X.31 VSPC 2CL HF 12 V DC 8924460000 8924710000 8924270000 VSPC 2CL HF 12 V DC R This tables contains recommendations for the choice of device. Our technical consultants will be glad to assist you with your individual requirements. 71 VARITECTOR SPC VARITECTOR SPC Pluggable lightning and surge protection for measurement and control circuits Pluggable lightning and surge protection for 2 analog signals or 4 binary signals in measurement/control circuits - with integrated error detection and alert functions in only 17.8 mm width. Our pluggable VARITECTOR SPC surge protection is characterised by highest protective functions with compact dimensions. The arrestor of the modules can be removed, measured or exchanged during running operation impedance-neutral - without interrupting the measuring circuit. These features make this product the ideal secure protection mechanism for interfaces within instrumentation and control circuits. Maintenance intervals are simplified by the V-TEST test unit, which is used for testing the function of the VARITECTOR SPC. This test method satisfies the requirements of standard IEC 62305. With the VARITECTOR SPC R modules, error detection and error messages are realised by internal monitoring. The green LED indicates the active protective function. The red LED indicates a fault condition. This information is transmitted to the V-Control evaluation unit. From there, the information can be sent across to e.g. a controller. Due to the impedance-neutral removing of the arrestor, the VARITECTOR SPC modules can be used instead of terminals. For four binary signals or two analog signals, just 17.8 mm of space on the mounting rail is used. By simply snapping onto a grounded mounting rail, time savings are also ensured when connecting. A color code identifies the various voltage levels for all VARITECTOR SPC modules. This simplifies maintenance work during operation. The EMC set offers additional convenience for connecting shielded cables. All VARITECTOR products comply with the latest IEC 61643-21:2008 requirement for a new overstress mode. Space-saving Saves space in the switching cabinet: 4 binary signals or 2 analog signals on 17.8 mm. 72 Standard-conformant Usable in accordance with installations standard IEC 62305: safely discharges high impulse currents up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE. Tested for class D1, C1 and C2 to IEC 61643-21:2008. VARITECTOR SPC Monitoring function Status display and message function: the protective function can be evaluated externally. Quick identification Color-coded marking: simple identification of the different voltage levels in the switching cabinet. 12 V = green 24 V = binary signal, blue 24 V = analog signal, yellow 48 V = red 60 V = violet special function = white Accessories EMC-set Consisting of shield connection and cable binder with shielded sheathing, the EMC set facilitates simple connection of the cable shield to the clamping yoke connections of the VARITECTOR SPC modules. Large variety A solution for every type of surge protection: current loops and binary signals as well as integrated components and combinations of current loops and voltage supply e.g. 24 V. V-TEST Instrument for testing the protective function of the product families: PU I, PU II and VSPC to IEC 62305 (periodic testing). 73 VARITECTOR SPC VSPC 1CL - protection for one analog signal * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional version with floating earth PE connection to avoid voltage potential differences * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 10 GND 3 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 4 TS 5 1 unprotected 2 protected 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing 6 Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 74 90 / 17.8 / 69 Type VSPC BASE 1CL VSPC BASE 1CL FG Technical data can be found on page 106. Qty. Part No. 1 8924730000 1 8924290000 VARITECTOR SPC VSPC 1CL - arrester / plug-in elements Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 1CL 5 V DC VSPC 1CL 12 V DC VSPC 1CL 24 V DC VSPC 1CL 24 V AC 5V 12 V 24 V 6.4 V 450 mA 730 KHz 20 ms 800 V 15 V 450 mA 1.7 MHz 20 ms 800 V 28 V 450 mA 2.4 MHz 30 ms 800 V 24 V 34 V 28 V 40 V 450 mA 2.7 MHz 450 ms 800 V 12 V 12 V 450 V 650 V 25 V 25 V 450 V 650 V 45 V 45 V 450 V 650 V 60 V 60 V 450 V 650 V VSPC 1CL 5VDC 8924420000 1 ST VSPC 1CL 12VDC 8924450000 1 ST VSPC 1CL 24VDC 8924480000 1 ST VSPC 1CL 24VAC 8924500000 1 ST VSPC 1CL 48 V AC VSPC 1CL 60 V AC 48 V 68 V 60 V 85 V 350 mA 4.8 MHz 500 ms 800 V 60 V 85 V 72 V 102 V 250 mA 7.3 MHz 500 ms 800 V 85 V 85 V 450 V 650 V 100 V 100 V 450 V 650 V VSPC 1CL 48VAC 8924520000 1 ST VSPC 1CL 60VAC 8924530000 1 ST Ordering Data No function display Type Part No. Qty. Note Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically Ordering Data No function display Type Part No. Qty. Note 75 VARITECTOR SPC VSPC 1CL - protection for one analog signal with remote alert * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional version with floating earth PE connection to avoid voltage potential differences * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing, with remote alert 11 GND 12 7 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 1 unprotected 6 2 protected 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing, with remote alert Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note 76 98 / 17.8 / 69 Type VSPC BASE 1CL FG R VSPC BASE 1CL R Technical data can be found on pages 106 and 107. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8951740000 1 8951730000 VARITECTOR SPC VSPC 1CL - arrester / plug-in components with remote alert Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 1CL 5 V DC R VSPC 1CL 12 V DC R VSPC 1CL 24 V DC R VSPC 1CL 24 V AC R 5V 12 V 24 V 6.4 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 15 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 28 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 24 V 34 V 28 V 40 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 730 KHz 20 ms 800 V 1.7 MHz 20 ms 800 V 2.4 MHz 30 ms 800 V 450 ms 12 V 12 V 450 V 650 V 25 V 25 V 450 V 650 V 45 V 45 V 450 V 650 V 60 V 60 V 450 V 650 V VSPC 1CL 5VDC R 8951530000 1 ST VSPC 1CL 12VDC R 8951540000 1 ST VSPC 1CL 24VDC R 8951550000 1 ST VSPC 1CL 24VAC R 8951560000 1 ST 2.6 MHz 800 V Ordering Data With functional display Type Part No. Qty. Note 77 VARITECTOR SPC VSPC 2CL - protection for two analog signals * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 2 analog signals with optional alert function and no extra space required * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 1 unprotected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing 2 protected Technical Data Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 78 90 / 17.8 / 69 Type VSPC BASE 2CL VSPC BASE 2CL FG Technical data can be found on page 106. Qty. Part No. 1 8924710000 1 8924270000 VARITECTOR SPC VSPC 2CL - arrester / plug-in elements Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2CL 5 V DC VSPC 2CL 12 V DC VSPC 2CL 24 V DC VSPC 2CL 24 V AC 5V 12 V 24 V 6.4 V 450 mA 730 KHz 20 ms 800 V 15 V 450 mA 1.7 MHz 20 ms 800 V 28 V 450 mA 2.3 MHz 30 ms 800 V 24 V 34 V 28 V 40 V 450 mA 2.7 MHz 450 ms 800 V 12 V 12 V 450 V 800 V 25 V 25 V 450 V 800 V 45 V 45 V 450 V 800 V 60 V 60 V 450 V 800 V VSPC 2CL 5VDC 8924400000 1 ST VSPC 2CL 12VDC 8924440000 1 ST VSPC 2CL 24VDC 8924470000 1 ST VSPC 2CL 24VAC 8924490000 1 ST VSPC 2CL 48 V AC VSPC 2CL 60 V AC 48 V 68 V 60 V 85 V 350 mA 4.8 MHz 500 ms 800 V 60 V 85 V 72 V 102 V 250 mA 7.3 MHz 500 ms 800 V 85 V 85 V 450 V 650 V 100 V 100 V 450 V 650 V VSPC 2CL 48VAC 8951490000 1 ST VSPC 2CL 60VAC 8951500000 1 ST Ordering Data No function display Type Part No. Qty. Note Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically Ordering Data No function display Type Part No. Qty. Note 79 VARITECTOR SPC VSPC 2CL - protection for two analog signals with remote alert * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 2 analog signals with optional alert function and no extra space required * Usable in accordance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE GND 11 12 7 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing, with remote alert 11 GND 12 7 8 9 10 GND OK FAULT 3 4 TS 5 6 1 unprotected X2 X1 2 protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing, with remote alert Technical Data Temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note 80 98 / 17.8 / 69 Type VSPC BASE 2CL FG R VSPC BASE 2CL R Technical data can be found on page 106. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8951720000 1 8951710000 VARITECTOR SPC VSPC 2CL - arrester / plug-in components with remote alert Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2CL 5 V DC R VSPC 2CL 12 V DC R VSPC 2CL 24 V DC R VSPC 2CL 24 V AC R 5V 12 V 24 V 6.4 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 15 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 28 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 24 V 34 V 28 V 40 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 730 KHz 20 ms 800 V 1.7 MHz 20 ms 800 V 2.3 MHz 30 ms 800 V 2.7 MHz 450 ms 12 V 12 V 450 V 800 V 25 V 25 V 450 V 800 V 45 V 45 V 450 V 800 V 60 V 60 V 450 V 800 V VSPC 2CL 5VDC R 8951460000 1 ST VSPC 2CL 12VDC R 8951470000 1 ST VSPC 2CL 24VDC R 8951480000 1 ST VSPC 2CL 24VAC R 1093400000 1 ST Ordering Data With functional display Type Part No. Qty. Note 81 VARITECTOR SPC VSPC 1CL PW - combination of current loop protection and end device protection * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Tested in accordance with IEC 61643-11:09 Class III * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 U FAULT U 24 V~ 1 2 protected unprotected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 U FAULT U 24 V~ 1 unprotected Complete module, indirect earthing 2 protected Measurement and control protection data Dielectric strength at FG against PE Volume resistance Rated current Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Standards Discharge current In (8/20s) wire-wire Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test current, Iimp (10/350 s) wire-wire End device protection data Combined pulse Uoc Max. continuous voltage, Uc (DC) Residual voltage, UP typical Rated current General data Type of connection Storage temperature Requirements category acc. to IEC 61643-21 Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters 6 kV 38 V 900 V 10 A Pluggable in VSPC BASE -40 C...+80 C C1, C2, C3, D1 -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 90 / 17.8 / 69 The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing / floating earth FG Base element, direct earthing Note 82 500 V 2.20 450 mA Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s IEC 61643-21 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Type VSPC BASE 1CL PW FG VSPC BASE 1CL PW Technical data can be found on page 106. Qty. Part No. 1 1105700000 1 1070230000 VARITECTOR SPC VSPC 1CL PW - arrester / plug-in components VSPC 1CL PW 24 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Signalling contact Optical function display 34 V 24 V 27 V 38 V For Class III protection, green = OK; red = arrester is defective - replace 3 MHz Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 10 ms 900 V 60 V 60 V 450 V 650 V Ordering Data No function display Type Part No. Qty. VSPC 1CL PW 24V 8951510000 1 ST Note 83 VARITECTOR SPC VSPC 2SL - protection for two binary signals * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 TS 5 1 unprotected Complete module, indirect earthing 4 6 2 protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 4.7 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 43 2665 2 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,4 0,35 Current [mA] 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 84 90 / 17.8 / 69 Type VSPC BASE 2SL VSPC BASE 2SL FG Technical data can be found on page 106. Qty. Part No. 1 8924720000 1 8924280000 VARITECTOR SPC VSPC 2SL - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2SL 5 V DC VSPC 2SL 12 V DC 5V 12 V 6.4 V 300 mA 1.2 MHz 20 ms 25 V VSPC 2SL 12 V AC VSPC 2SL 24 V DC 15 V 300 mA 2.5 MHz 20 ms 50 V 12 V 16 V 13.2 V 18.5 V 300 mA 3.2 MHz 20 ms 50 V 28 V 300 mA 2.7 MHz 30 ms 60 V 25 V 25 V 12 V 25 V 45 V 45 V 25 V 50 V 55 V 55 V 30 V 50 V 80 V 80 V 40 V 60 V VSPC 2SL 5VDC 8924210000 1 ST VSPC 2SL 12VDC 8924230000 1 ST VSPC 2SL 12VAC 8924250000 1 ST VSPC 2SL 24VDC 8924330000 1 ST VSPC 2SL 24 V AC VSPC 2SL 48 V AC VSPC 2SL 60 V AC 24 V 34 V 28 V 40 V 300 mA 5.5 MHz 60 ms 60 V 48 V 68 V 60 V 85 V 250 mA 8.7 MHz 60 ms 125 V 60 V 85 V 72 V 102 V 200 mA 13.6 MHz 60 ms 165 V 110 V 80 V 60 V 60 V 210 V 80 V 85 V 125 V 280 V 80 V 100 V 165 V VSPC 2SL 24VAC 8924350000 1 ST VSPC 2SL 48VAC 8924370000 1 ST VSPC 2SL 60VAC 8924390000 1 ST 24 V Ordering Data No function display Type Part No. Qty. Note Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically Ordering Data No function display Type Part No. Qty. Note 85 VARITECTOR SPC VSPC 2SL - protection for two binary signals with remote alert * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND OK FAULT X2 X1 3 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing, with remote alert 11 GND 12 7 8 9 10 GND OK FAULT 3 4 TS 5 6 1 unprotected X2 X1 2 protected Complete module, indirect earthing, with remote alert Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 4.7 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 43 2665 2 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,4 0,35 Current [mA] 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note 86 98 / 17.8 / 69 Type VSPC BASE 2SL FG R VSPC BASE 2SL R Technical data can be found on page 107. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8951780000 1 8951770000 VARITECTOR SPC VSPC 2SL - arrester / plug-in elements with remote alert Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2SL 5 V DC R VSPC 2SL 12 V DC R VSPC 2SL 24 V DC R VSPC 2SL 24 V AC R 5V 12 V 24 V 6.4 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 15 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 28 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 24 V 34 V 28 V 40 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 1.2 MHz 20 ms 25 V 2.5 MHz 20 ms 50 V 2.7 MHz 30 ms 60 V 5.5 MHz 60 ms 60 V 25 V 25 V 12 V 25 V 45 V 45 V 25 V 50 V 80 V 80 V 40 V 60 V 110 V 80 V 60 V 60 V VSPC 2SL 5VDC R 8951610000 1 ST VSPC 2SL 12VDC R 8951620000 1 ST VSPC 2SL 24VDC R 8951630000 1 ST VSPC 2SL 24VAC R 8951640000 1 ST Ordering Data With functional display Type Part No. Qty. Note 87 VARITECTOR SPC VSPC 4SL - protection for four binary signals * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 4 binary signals with optional alert function and no extra space required * Usable in accordance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE GND 11 12 7 8 9 3 10 GND TS 5 4 6 1 2 unprotected protected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 TS 5 1 unprotected Complete module, indirect earthing 4 6 2 protected Technical Data Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 4.7 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 43 2665 2 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,4 0,35 Current [mA] 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 88 90 / 17.8 / 69 Type VSPC BASE 4SL VSPC BASE 4SL FG Technical data can be found on page 106. Qty. 1 1 Part No. 8924700000 8924260000 VARITECTOR SPC VSPC 4SL - arrester / plug-in elements Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 4SL 5 V DC VSPC 4SL 12 V DC 5V 12 V 6.4 V 300 mA 1.2 MHz 20 ms 25 V VSPC 4SL 12 V AC VSPC 4SL 24 V DC 15 V 300 mA 2.5 MHz 20 ms 35 V 12 V 16 V 13.2 V 18 V 300 mA 3.2 MHz 20 ms 50 V 28 V 300 mA 4 MHz 30 ms 60 V 25 V 25 V 12 V 25 V 45 V 45 V 25 V 50 V 55 V 55 V 30 V 50 V 80 V 80 V 40 V 60 V VSPC 4SL 5VDC 8924200000 1 ST VSPC 4SL 12VDC 8924220000 1 ST VSPC 4SL 12VAC 8924240000 1 ST VSPC 4SL 24VDC 8924320000 1 ST VSPC 4SL 24 V AC VSPC 4SL 48 V AC VSPC 4SL 60 V AC 24 V 34 V 28 V 39 V 300 mA 2.7 MHz 40 ms 60 V 48 V 68 V 60 V 85 V 250 mA 8.7 MHz 60 ms 125 V 60 V 85 V 72 V 101 V 200 mA 13.6 MHz 60 ms 165 V 110 V 80 V 60 V 60 V 210 V 80 V 85 V 125 V 280 V 80 V 110 V 165 V VSPC 4SL 24VAC 8924340000 1 ST VSPC 4SL 48VAC 8924360000 1 ST VSPC 4SL 60VAC 8924380000 1 ST 24 V Ordering Data No function display Type Part No. Qty. Note Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically Ordering Data No function display Type Part No. Qty. Note 89 VARITECTOR SPC VSPC 4SL - protection for four binary signals with remote alert * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 4 binary signals with optional alert function and no extra space required * Usable in accordance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE GND 11 12 7 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing, with remote alert 11 GND 12 7 8 9 10 GND OK FAULT 3 TS 5 6 1 unprotected X2 X1 4 2 protected Complete module, indirect earthing, with remote alert Technical Data Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 4.7 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 43 2665 2 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,4 0,35 Current [mA] 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note 90 98 / 17.8 / 69 Type VSPC BASE 4SL FG R VSPC BASE 4SL R Technical data can be found on page 107. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8951760000 1 8951750000 VARITECTOR SPC VSPC 4SL - arrester / plug-in elements with remote alert Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 4SL 5 V DC R VSPC 4SL 12 V DC R VSPC 4SL 24 V DC R VSPC 4SL 24 V AC R 5V 12 V 24 V 6.4 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 15 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 28 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 24 V 34 V 28 V 39 V 300 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 1.2 MHz 20 ms 25 V 2.5 MHz 20 ms 35 V 4 MHz 30 ms 60 V 2.7 MHz 40 ms 60 V 25 V 25 V 12 V 25 V 45 V 45 V 25 V 50 V 80 V 80 V 40 V 60 V 110 V 80 V 60 V 60 V VSPC 4SL 5VDC R 8951570000 1 ST VSPC 4SL 12VDC R 8951580000 1 ST VSPC 4SL 24VDC R 8951590000 1 ST VSPC 4SL 24VAC R 8951600000 1 ST Ordering Data With functional display Type Part No. Qty. Note 91 VARITECTOR SPC VSPC 4 SL WIRE - protection for 3/4-wire signals * Protection of measuring bridge signals * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 4 binary signals with optional alert function and no extra space required * Usable in accordance with installations standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1,C1,C2,C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE 11 GND 12 7 8 9 10 GND 3 TS 5 4 6 1 2 protected unprotected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 TS 5 1 unprotected 4 6 Technical Data Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 2 500 V 0.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 43 2655 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,5 protected 0,45 Complete module, indirect earthing 0,4 Current [mA] 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 92 90 / 17.8 / 69 Type VSPC BASE 2/4CH VSPC BASE 2/4CH FG Technical data can be found on page 106. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8924740000 1 8924300000 VARITECTOR SPC VSPC 4SL WIRE - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Capacitance Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 3/4 WIRE 5 V DC VSPC 3/4 WIRE 24 V DC 3V 24 V 6.4 V 450 mA No No 2.3 nF 20 ms 800 V 28 V 450 mA No No 935 pF 30 ms 800 V 35 V 35 V 250 V 800 V 50 V 50 V 270 V 800 V VSPC 3/4WIRE 5VDC 8924540000 1 ST VSPC 3/4WIRE 24VDC 8924550000 1 ST Ordering Data No function display Type Part No. Qty. Note 93 VARITECTOR SPC VSPC GDT - with sparkover gap (GDT) * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND 3 4 TS 5 6 1 2 protected unprotected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 4 TS 5 1 unprotected 6 Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 0.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2 x 2.5 kA / 2.5 kA / 2.5 kA 2 x 10 kA / / 10 kA 2 x 0.2 kA / / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 11 10378 3 CE; GOSTME25; TUEV; UL According to IEC61643-21 2 protected Complete module, indirect earthing Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 94 90 / 17.8 / 69 Type VSPC BASE 2/4CH VSPC BASE 2/4CH FG Technical data can be found on page 106. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8924740000 1 8924300000 VARITECTOR SPC VSPC GDT - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Capacitance Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC GDT 2CH 90 V VSPC GDT 2CH 150 V AC/230 V DC 48 V 68 V 50 V 72 V 2A No No 9.37 pF 1000 V 110 V 150 V 125 V 180 V 2A No No 7.45 pF 800 V 650 V 1000 V 650 V 950 V 450 V 800 V 800 V 800 V VSPC GDT 2CH 90V 8924570000 1 ST VSPC GDT 2CH 150Vac/230Vdc 8924590000 1 ST Ordering Data No function display Note Type Part No. Qty. The 90 V gas discharge tube has a tolerance of +/- 20%. The 230 V gas discharge tube has a tolerance of +/- 20%. 95 VARITECTOR SPC VSPC MOV - protection with varistor * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status display and alert functions for MOV components * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 12 U GND 7 8 9 10 GND 3 4 TS 5 6 U unprotected 1 2 protected Complete module, direct earthing 11 12 U 7 GND 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 6 U unprotected 1 2 protected Complete module, direct earthing, with remote alert 11 12 Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 0.20 Mode 1 C1, C2, C3, D1 < 1 kA 8/20 s 1.5 kA 8/20 s 100 A 10/1000 s 0.5 kA 10/350 s 0.2 kA / 2.5 kA / 0.5 kA 1.5 kA / / 1.5 kA 0.2 kA / / 0.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 26 4391 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 U GND 7 8 9 10 GND 3 4 TS 5 6 U unprotected 1 2 protected Complete module, indirect earthing 11 12 U 7 GND 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) 6 U unprotected 1 2 Complete module, indirect earthing, with remote alert Base elements / base to arresters Note The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Base element, direct earthing Base element, indirect earthing / floating earth FG Note 96 90 / 17.8 / 69 protected Type VSPC BASE 2/4CH FG R VSPC BASE 2/4CH R VSPC BASE 2/4CH VSPC BASE 2/4CH FG Technical data can be found on pages 106 and 107. Order with VSPC CONTROL UNIT. Qty. 1 1 1 1 Part No. 8951800000 8951790000 8924740000 8924300000 VARITECTOR SPC VSPC MOV - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Capacitance Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically Ordering Data Type Part No. Qty. VSPC MOV 2CH 24 V VSPC MOV 2CH 230 V VSPC MOV 2CH 24 V R VSPC MOV 2CH 230 V R 24 V 24 V 30 V 38 V 10 A No 230 V 230 V 275 V 350 V 10 A No 24 V 24 V 30 V 38 V 10 A UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 230 V 230 V 275 V 350 V 10 A UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT No No green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 14.5 nF 200 V 720 pF 850 V 14.5 nF 200 V 720 pF 850 V 80 V 95 V 600 V 700 V 80 V 95 V 600 V 700 V Without functional display VSPC MOV 2CH 24V 8924600000 1 ST Without functional display VSPC MOV 2CH 230V 8924610000 1 ST With functional display VSPC MOV 2CH 24V R 8951650000 1 ST With functional display VSPC MOV 2CH 230V R 8951660000 1 ST Note 97 VARITECTOR SPC VSPC TAZ - protection with transport diode * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status display and alert functions for MOV components * Lower residual voltage * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND 3 TS 4 5 6 1 2 unprotected protected Complete module VSPC TAZ 2ch direct earthing GND 11 12 7 8 9 10 GND 3 unprotected TS 4 5 6 1 2 protected Complete module VSPC TAZ 2ch indirect earthing 11 GND 7 8 9 10 GND 3 unprotected 12 TS Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 0.20 Mode 1 C3 20 A 10/1000 s 0.05 kA / / 0,1 kA / / Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 32 3567 3 CE; GOSTME25; OEVE; TUEV; UL According to IEC61643-21 4 5 6 1 2 protected Complete module VSPC TAZ 4ch direct earthing 11 GND 7 8 9 10 GND 3 unprotected 12 TS 4 5 6 1 2 Complete module VSPC TAZ 4ch indirect earthing Base elements / base to arresters Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 98 90 / 17.8 / 69 protected Type VSPC BASE 2/4CH VSPC BASE 2/4CH FG Technical data can be found on page 106. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8924740000 1 8924300000 VARITECTOR SPC VSPC TAZ - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Capacitance Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC TAZ 2CH 24 V AC VSPC TAZ 4CH 24 V 24 V 24 V 28 V 39 V 10 A No No 387 pF 65 V 24 V 24 V 28 V 39 V 10 A No No 680 pF 65 V 50 V 55 V 55 V 65 V 50 V 55 V 55 V 65 V VSPC TAZ 2CH 24V 8924640000 1 ST VSPC TAZ 4CH 24V 8924650000 1 ST Ordering Data No function display Type Part No. Qty. Note 99 VARITECTOR SPC VSPC TELE UK0 - protection for telephones * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Two-wire input interface - Uko * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data La (-) 11 Lb (+) 7 8 GND 9 10 GND La (-) 5 3 Lb (+) 12 TS 4 6 1 2 protected unprotected Complete module, direct earthing La (-) 11 Lb (+) 7 8 GND 9 10 GND La (-) 5 3 Lb (+) 12 TS 1 unprotected 4 6 Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 49 2330 3 CE; GOSTME25; TUEV; UL According to IEC61643-21 2 protected Current [mA] Complete module, indirect earthing Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters Order the associated VSPC base element with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 100 90 / 17.8 / 69 Type VSPC BASE 2CL VSPC BASE 2CL FG Technical data can be found on page 106. Qty. Part No. 1 8924710000 1 8924270000 VARITECTOR SPC VSPC TELE UK0 - arrester/plug-in components VSPC TELE UK0 2 WIRE Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 127 V 120 V 130 V 180 V 450 mA No No 101.7 MHz 60 ms 800 V 250 V 300 V 450 V 800 V Ordering Data No function display Type Part No. Qty. VSPC TELE UK0 2WIRE 8924660000 1 ST Note 101 VARITECTOR SPC VSPC RS485 - protection for data signals * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status indicator and alert functions * Lower residual voltage * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 3 unprotected 10 GND TS 4 5 6 1 2 protected Complete module, direct earthing GND 11 12 7 8 9 10 GND 3 unprotected TS 4 5 6 1 2 Complete module, indirect earthing protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 57 2003 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,5 0,45 0,4 Current [mA] 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note 102 90 / 17.8 / 69 Type VSPC BASE 2CL VSPC BASE 2CL FG Technical data can be found on page 106. Qty. Part No. 1 8924710000 1 8924270000 VARITECTOR SPC VSPC RS485 - arrester / plug-in components VSPC RS485 2CH Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 5V 6.4 V 450 mA 113.6 MHz 20 ms 35 V 10 V 15 V 10 V 35 V Ordering Data No function display Type Part No. Qty. VSPC RS485 2CH 8924670000 1 ST Note 103 VARITECTOR SPC VSPC RS485 - protection for data signals with remote alert * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status indicator and alert functions * Lower residual voltage * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 10 GND OK FAULT 3 unprotected X2 X1 4 TS 5 6 1 2 protected Complete module, direct earthing, with remote alert GND 11 12 7 8 9 10 GND OK FAULT 3 unprotected TS X2 X1 4 5 6 1 2 Complete module, indirect earthing, with remote alert protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 90 1266 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,5 0,45 0,4 Current [mA] 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note 104 98 / 17.8 / 69 Type VSPC BASE 2/4CH FG R VSPC BASE 2/4CH R Technical data can be found on page 107. Order with VSPC CONTROL UNIT. Qty. Part No. 1 8951800000 1 8951790000 VARITECTOR SPC VSPC RS485 - arrester / plug-in components with remote alert VSPC RS485 2CH R Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact 5V 6.4 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace Optical function display 113.6 MHz 20 ms 35 V Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 10 V 15 V 10 V 35 V Ordering Data With functional display Type Part No. Qty. VSPC RS485 2CH R 8951670000 1 ST Note 105 VARITECTOR SPC Direct earthing Base element Base element with FG UNPROTECTED PROTECTED 9 1 5 6 UNPROTECTED 2 PROTECTED 9 11 12 GND 10 9 GND 7 12 GND 10 8 6 PE 4 3 PE 2 1 Similar to illustration TS PE 2 5 PE 4 1 6 7 6 3 PE 5 9 GND 8 5 1 11 2 TS Similar to illustration PE Technical Data Stripping length, rated connection Wire cross-section, stranded, min. Wire cross-section, stranded, max. Wire cross-section, solid, min. Wire cross-section, solid, max. Clamping range, rated connection, min. Clamping range, rated connection, max. Tightening torque, min. Tightening torque, max. Type of connection Certificate No. (UL) Approvals Ambient temperature (operational) Storage temperature UL 94 flammability rating Pollution severity Surge voltage category 7 mm 0.5 mm 2.5 mm 0.5 mm 4 mm 0.5 mm 4 mm 0.5 Nm 0.8 Nm Screw connection E311081VOL1SEC2 CE; GOSTME25; UL -40 C...+70 C -40 C...+80 C V-0 2 III 7 mm 0.5 mm 2.5 mm 0.5 mm 4 mm 0.5 mm 4 mm 0.5 Nm 0.8 Nm Screw connection E311081VOL1SEC2 CE; GOSTME25; UL -40 C...+70 C -40 C...+80 C V-0 2 III Dimensions Height x width (mm) 90 / 17.8 90 / 17.8 Note Ordering Data No remote sig. contact Type VSPC BASE 1CL VSPC BASE 2SL VSPC BASE 2CL VSPC BASE 2/4CH VSPC BASE 1CL PW VSPC BASE 4SL Qty. 1 1 1 1 1 1 Part No. 8924730000 8924720000 8924710000 8924740000 1070230000 8924700000 Type VSPC BASE 1CL FG VSPC BASE 2SL FG VSPC BASE 2CL FG VSPC BASE 1CL PW FG VSPC BASE 2/4CH FG VSPC BASE 4SL FG Note Accessories Note 106 EMC Set: 1067470000 Marker: DEK 5 EMC Set: 1067470000 Marker: DEK 5 Qty. 1 1 1 1 1 1 Part No. 8924290000 8924280000 8924270000 1105700000 8924300000 8924260000 VARITECTOR SPC Direct earthing, with remote alert Base element Base element with FG UNPROTECTED 7 11 UNPROTECTED PROTECTED 9 1 5 6 2 X2 X1 minus plus 11 12 7 11 8 12 GND 10 9 GND 7 2 plus X2 minus X2 X1 minus plus 12 8 12 GND 10 8 6 PE 4 3 PE 2 X1 TS PE 6 7 PE 4 1 5 5 6 3 PE 1 9 GND 8 5 PROTECTED 9 11 2 1 Similar to illustration X1 TS PE plus X2 minus Similar to illustration Technical Data Stripping length, rated connection Wire cross-section, stranded, min. Wire cross-section, stranded, max. Wire cross-section, solid, min. Wire cross-section, solid, max. Clamping range, rated connection, min. Clamping range, rated connection, max. Tightening torque, min. Tightening torque, max. Type of connection Certificate No. (UL) Approvals Ambient temperature (operational) Storage temperature UL 94 flammability rating Pollution severity Surge voltage category 7 mm 0.5 mm 2.5 mm 0.5 mm 4 mm 0.5 mm 4 mm 0.5 Nm 0.8 Nm Screw connection E311081VOL1SEC2 CE; GOSTME25; UL -40 C...+70 C -40 C...+80 C V-0 2 III 7 mm 0.5 mm 2.5 mm 0.5 mm 4 mm 0.5 mm 4 mm 0.5 Nm 0.8 Nm Screw connection E311081VOL1SEC2 CE; GOSTME25; UL -40 C...+70 C -40 C...+80 C V-0 2 III Dimensions Height x width (mm) 98 / 17.8 98 / 17.8 Note Ordering Data With remote sig. contact (R) Type VSPC BASE 2SL R VSPC BASE 1CL R VSPC BASE 2CL R VSPC BASE 2/4CH R VSPC BASE 4SL R Qty. 1 1 1 1 1 Part No. 8951770000 8951730000 8951710000 8951790000 8951750000 Type VSPC BASE 2SL FG R VSPC BASE 1CL FG R VSPC BASE 2CL FG R VSPC BASE 2/4CH FG R VSPC BASE 4SL FG R Qty. 1 1 1 1 1 Part No. 8951780000 8951740000 8951720000 8951800000 8951760000 Note Accessories Note EMC Set: 1067470000 Marker: DEK 5 EMC Set: 1067470000 Marker: DEK 5 107 VARITECTOR SPC VSPC accessories V-Ground * Can be applied to unassigned wires * Usable during start-up and maintenance * Earthing of all sensor cables * Can be plugged into standard base sockets V-Test-Connector * Usable during start-up and maintenance * For circuit voltage measurements using a standard 2.3-mm test socket * Can be plugged into standard base sockets Technical Data VSPC TEST Connector 24 V DC Rated voltage (DC) Max. continuous voltage, Uc (DC) Rated current Volume resistivity per path Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection VSPC GROUND Note 1 5 GND 7 11 230 V AC 255 V AC < 0.5 A < 0.2 Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C 5 %...96 % RH IP 20 Ordering Data Arrester / plug-in elements Type VSPC TEST Connector 24DC VSPC GROUND Qty. 1 1 Note Ordering Data Shield connection: 108 Complete set - cable ties and shield connection Cable ties Shield connection Cable tie tool Type EMC-set EMC-tie EMC-connector Cable tie tool RT-1 Qty. 1 100 50 1 Part No. 1067470000 1067490000 1067520000 1296000000 Part No. 8924690000 8924680000 VARITECTOR SPC The interlock mechanism on the VSPC Series pluggable arresters delivers extra reliability and an improved permanent contact under strong vibrating conditions. VSPC Locking Clip Technical Data Color Marking Function Weight Note Ordering Data yellow Individually with a label Removal with screwdriver Snap-on by hand (press on) 10 g Type VSPC LOCKING CLIP Qty. 100 Part No. 1317340000 Note Cross-connection (QB) between the VSPC signal contacts can be installed quickly. Cross-connections can be individually separated for the alert function, with maximum of 10 VSPC R. QB 17.8/2 Technical Data Version Dimensions (L x W x H) Pitch Rated current Cross-section Weight Color Note Ordering Data 2-pole with 9 QBs together = 1 strip 9 mm (15.5 mm with contact) x 6 mm x 21 mm (9 QBs = 160.7 mm) 17.8 mm 17.5 A 1.5 mm 12.4 g/QB yellow Type QB 17.8/2 Qty. 10 strips, with 9 QBs each Part No. 1309470000 Note 109 VARITECTOR SPC VSPC CONTROL UNIT 24 V DC * For monitoring up to 10 protective modules * Signalling module for all VSPCs with status indicator * Signalling of cable breaks / signal interruptions * Voltage supply from 18...31 V DC * Potential-free changeover contact * Function indicator (red/green LED) * Other NC-contact monitoring functions can be integrated into the signal circuit (e.g.PU I, PU II and PU III) Technical Data X2 24 V X1 0V 12 11 14 VSPC CONTROL UNIT X2 X2 X1 nmax = 10 VSPC...R X2 X1 X1 n=1 VSPC...R n=2 VSPC...R Input Rated voltage (DC) Rated current Power rating Output Current loop Monitoring option Signal output Type Max. switching voltage / continuous current Diagnostics Operating status Defect at current loop Wire breakage General data Terminal rail Design, Protection class Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Start-up time after fault correction 18 V...24 V DC...31 V DC max. 50 mA 1.5 W 8 mA at < 51 V 1...10 VSPC modules 1 CO contact 250 V / 1 A Green LED Red LED (control unit and defective module) Red/green LED, flashing TS 35 Insta-enclosure, IP 20 BL / SL -40 C...+80 C -40 C...+70 C 5 %...96 % RH 60 s Dimensions Dimensions incl. enclosure H x W x D (mm) Note Ordering Data Application Type VSPC CONTROL UNIT 24Vdc Note l 3 meter n x VSPC...R n 10 VSPC CONTROL UNIT Status indication LED green LED red Function OK Error (one or more VSPC ... R are defective) Line break in the monitoring circuit; arrester pulled out or plug not in base 110 102 x 18 x 71.5 Qty. 1 piece Part No. 8972270000 111 V-TEST V-TEST Testing device from the VARITECTOR Series A testing device for pluggable surge protection: for testing in compliance with the IEC 62305-3 standard The V-TEST is a compact, easily carried, testing device for pluggable protection modules from the VARITECTOR SPC family. The testing device can be used to test the protective function of the overvoltage protection components in accordance with the test intervals required in IEC 62305-3. It provides information regarding the functional status of the protective components. The backlit display shows the measured reading per component (GDT, MOV, TAZ) as "OK" or "not OK". This function allows you to detect ageing components as it highlights possible damage right away. Thus total protection in guaranteed. The V-TEST is equipped with a charger and a battery set which allows autonomous use in the field. A comfortable and protective carry bag is delivered free with the tester. Always delivers precise readings The V-TEST self-calibrates when it is turned on, ensuring that it can always deliver precise measurement and test values. Portable The compact device comes with an integrated rechargeable battery and protective case - making it perfect for use in the field. 112 V-TEST Ensures timely testing intervals The portable V-TEST can be used to carry out repeated testing in compliance with IEC 62305-3. Lightning protection level (LPL) I II III/IV Interval for complete testing 2 years 4 years 6 years Interval for visual inspection 1 year 2 years 3 years Quick and easy to operate It only takes a few simple menu steps (in German or English) to navigate directly to the measurement function. 113 V-TEST VSPC accessories V-TEST * Instrument for testing the protective functions of series: PU I, PU II and VSPC * Device for realising standard IEC 62305 (periodic testing) * Handy device with integrated battery set for local measurements * Result display via LCD display * Bilingual menu * Including protective bag and power supply * Intuitive user navigation in German and English The V-TEST is a compact, portable instrument for the Varitector SPC pluggable surge protection (VSPC series) and surge protection for power distribution, PUI and II series. With this instrument, Weidmuller surge protection solutions can be tested for protective function in accordance with the required test periods as stipulated by IEC62305 (DIN VDE 185 Part 3). In a backlit display, the measurement result is indicated with "OK" or "not OK" for each component. Technical Data Rated voltage Accumulator set Storage temperature Ambient temperature (operational) Degree of protection Measuring range UL94 flammability class 100...240 V AC 8 NiMH with 2600 mA 0 C ... 40 C 0 C ... 40 C IP 20 U < 1000 V / I = 1 mA V0 General tolerances of measurement range Gas discharge tube Varistor TVS-diode +/- 10% +/- 5% +/- 5% Dimensions Height x Width x Depth (mm) 230 x 122 x 65 Note Ordering Data Type V-TEST Note 114 Qty. 1 Part No. 8951860000 VARITECTOR SSC - Overview VARITECTOR SSC Surge protection in a terminal block: for measurement and control systems VARITECTOR SSC Weidmuller`s VARITECTOR SSC series for surge protection (VSSC4 and VSSC6) is well suited for protecting measurement and control circuits. It features good protective functionality in a compact terminal-block design. This is due to its 6.2 mm width. The combined Torx(R)/ slotted screw ensures that the proper nominal or max. torque is applied to the connection. The required screwdrivers are available from Weidmuller under the following order numbers: 4-mm slotted SD 0.8 x 4.0 x 100 (part no. 9008340000) or T15 Torx(R) (part no. 9009170000). The VSSC can be snapped on, to directly earth it to the DIN-rail. The VSSC series is available with four clamping yokes (VSSC4) and six clamping yokes (VSSC6). The screw terminal has a nominal torque of 0.5 Nm, but it can be tightened to 0.8 Nm. The VARITECTOR SSC series is optimally designed for compact installation locations in process automation, industrial automation or building automation. The two-stage surge protection terminals are equipped with gas discharge tubes (GDT), suppressor diodes (TVS) and decoupling components. Individual protective components (such as gas-filled spark gaps, varistors and suppressor diodes) supplement this product line. Our VARITECTOR SSC surge protectors are available for components with nominal voltages of 12 V, 24 V, 48 V to 230 V. Please contact us for other voltages or special applications. The two-stage surge protection terminals are equipped with gas discharge tubes (GDT), suppressor diodes (TVS) and decoupling components. Individual protective components (such as gas-filled spark gaps, varistors and suppressor diodes) supplement this product line. Our VARITECTOR SSC surge protectors are available for components with nominal voltages of 12 V, 24 V, 48 V to 230 V. Please contact us for other voltages or special applications. The PE contact is established by snapping onto an earthed DIN-rail. The TS 35 must be earthed in order to ensure safe power discharging via the terminals of up to 20 kA (8/20 s) and 2.5 kA (10/350 s). The DIN-rail must be screwed onto the earthed mounting plate to ensure EMC. The best protection is achieved when a PE contact is established every 60 cm / 24 inch using the terminal at the VARITECTOR SSC terminals with direct equipotential bonding. The cable should correspond to the max. cross-section of the VSSC connection. The four-port VARITECTOR SSC terminal can be used for binary and / or analog signal circuits. The six-port VARITECTOR SSC can also be used to open signal circuits via an isolated level and monitor them using the optional built-in LED. Overview of model types VSSC4 CL The VSSC4 CL is a two-stage protective combination that has a suppressor diode between the current paths. This VSSC4 CL limits the surge voltage in an analog signal circuit (e.g. a current loop). The VSSC4 CL FG is a two-stage protective combination that has a suppressor diode between the current paths. The gas discharge tube to the PE provides a high-resistance earthing for the protective circuitry. Thus the current loop can be operated with a floating ground. This VSSC4 CL FG limits the surge voltage in an analog unearthed signal circuit (e.g. a current loop). VSSC4 SL The basic principle of a binary current circuit VARITECTOR SSC6 The VSSC4 SL is a two-stage protective combination with a suppressor diode for each stage from the current path to PE. This VSSC4 SL limits the surge voltage in an earthed binary signal (e.g. for alert contacts). The VSSC4 SL FG is used for nonearthed signal circuits. VARITECTOR SSC4 115 VARITECTOR SSC - Overview VARITECTOR SSC The VSSC4 SL FG is a two-stage protective combination with a suppressor between the current paths and common return wire. The gas discharge tube to the PE provides a high-resistance earthing for the protective circuitry. Thus the protective circuitry can be operated with a floating earth. This VSSC4 SL FG limits the surge voltage in a binary floating signal circuit. VSSC4 TAZ The VSSC4 TAZ provides one-stage protection with a quick-response (<10 ps) suppressor diode (TAZ) for the current path to PE. This VSSC4 TAZ limits the surge voltage in a circuit (e.g. for digital inputs). The TAZ is available in voltages of 12 V, 24 V, 48 V and 60 V. VSSC4 MOV The VSSC4 MOV provides one-stage protection with a varistor (MOV) for the current path to PE. This VSSC4 MOV limits the surge voltage in a circuit (e.g. for solenoid valves). The thermally monitored MOV is available in voltages of 12 V, 24 V, 48 V, 60 V, 120 V, 150 V and 240 V. 240 V. VSSC4 RC is the final protective variant in the VSSC series. This variant combines a thermally monitored varistor and an RC combination. It can be used for spark suppression on inductive loads. The VSSC4 RC is available in 24 V and 240 V. VSSC4 GDT The VSSC4 GDT provides one-stage protection with a gas discharge tube (GDT) for the current path to PE. This VSSC4 GDT limits the surge voltage in a circuit. This terminal is used where no leakage current is permitted to flow to the earth, or where a highimpedance cable shield is connected to the earth. The GDT is available in voltages of 90 V, 110 V and 240 V. 116 VSSC4 RC VSSC6 CL The VSSC6 CL is a two-stage protective combination that has a suppressor diode between the current paths. This VSSC6 CL limits the surge voltage in an analog signal circuit (e.g. a current loop). The PE potential can be provided on terminal point 3/6 by snapping the terminal on an earthed DIN-rail. This allows a shield connection to be connected. This version is also available as the VSSC6 CL FG floatingground protective circuit. The VSSC6 TR CL is built like the VSSC6 CL and also has two isolators. The 2.3-mm PS 2.3 (part no. 018040000) can be plugged into the Torx(R) screw head. The isolation makes it possible to take measurements in the field, in the electrical cabinet or via the surge protection. This version is also available as the VSSC6 TR CL FG floating-ground protective circuit. The VSSC6 SL LD is a two-stage protective combination with a suppressor between the current paths and common return wire. This VSSC6 SL limits the surge voltage in two binary signal circuits. The signal status for each signal circuit is indicated by an LED. The VSSC6 TR SL LD is built like the VSSC6 L LD but also has two isolators. The 2.3-mm plug uses the screws to provide easy signal measurements. This version is also available as the VSSC6 TR SL FG floating-ground protective circuit. The VSSC6 MOV provides one-stage protection with two thermally monitored varistors (MOV) between the current paths and common return wire. This VSSC6 MOV limits the surge voltage in two binary signal circuits. The VSSC6 TR LD MOV provides one-stage protection with two thermally monitored varistors (MOV) between the current paths and common return wire. The VSSC6 MOV limits the surge voltage in two binary signal circuits and also has an isolator and an LED for each signal circuit. VARITECTOR SSC - Overview Installation The VSSC6 GDT provides one-stage protection with two gas discharge tubes (GDT) between the current paths and common return wire. This VSSC6 GDT limits the surge voltage in two binary signal circuits. The VSSC6 TR LD GDT provides two-stage protection with two gas discharge tubes (GDT) between the current paths and common return wire. The VSSC6 GDT limits the surge voltage in two binary signal circuits and also has an isolator for each signal circuit. The VSSC6 TAZ provides one-stage protection with two suppressor diodes (TAZ) between the current paths and common return wire. The VSSC6 TAZ limits the surge voltage in two binary signal circuits and also has an isolator and an LED for each signal circuit. The VSSC6 TR LD TAZ provides onestage protection with two suppressor diodes (TAZ) between the current paths and common return wire. The VSSC6 TAZ limits the surge voltage in two binary signal circuits and also has an isolator and an LED for each signal circuit. VSSC6 RS422/485 The VSSC6 RS485 is a two-stage protective combination that has suppressor diodes between the current paths. This VSSC6 RS485 limits the surge voltage in two high-frequency signal circuits with common return wires. The VSSC RS485 is available in the PROFIBUS PA and DP variants. VSSC6 RS232 The VSSC6 RS232 is a two-stage protective combination that has suppressor diodes between the current paths. This VSSC6 RS232 limits the surge voltage in a signal circuit. Black Material PA6.6 with UL94 V0 is used for the VSSC4 and VSSC6 series so that they are suitable for use in many applications. They are suitable for use in temperatures ranging from -40 to +70 C. The VSSC series is used to protect signal circuits. In order to achieve a complete protective strategy for the facility, the power feed must be protected with Type II surge protection (for example, by using the VPU II series). For existing lightning protection facilities, Type I protection must be used (for example, by using the VPU I series). Type II protection (for example, the VPU II) is sufficient when there is no lightning protection facility. Discharge capacity Tested in compliance with standard IEC 61643-21 for providing surge protection in signalling networks with voltage and current pulses. The VSSC series has been tested to comply with IEC 61643-21 and EN 61643-21. Modules were tested with categories C1, C2 and C3: with quick-rising edges with up to 300 pulses. Category D1 describes high-power testing (10/350 s), so that the VSSC series can be used in compliance with IEC 62305-4. The VSSC is color-coded so that it is easy to detect the voltage level (or the signal location SL or CL). Color coding Voltage level 12 V 24 V Binary 24 V Analog 48 V 60 V Special function Color green blue yellow red violet white Fusing The VSPC surge protection modules are designed so that they are decoupled between the individual protective stages. When relying on an external fuse, make sure to maintain the following: * Maximum nominal current * Derating curve * Type of installation * Application Category IEC 61643-21 C1, C2, C3, D1 117 VARITECTOR SSC - Overview VARITECTOR SSC Category Testing pulse C1 Quick rising edge Surge voltage 0.5 < 2 kV with 1.2/50 s C2 Quick rising edge 2 < 10 kV 1 < 5 kA with with 1.2/50 s 8/20 s Quick rising edge 1 kV with 1 kV/s 10 < 100 A 300 with 10/10.000 s Surge voltage arrester High power 1 kV 0.5 < 2.5 kA 2 with 10/350 s Arrester for lightning current and surge voltages C3 D1 Surge Pulse Type current 0.25 < 1 kA 300 Surge with voltage 8/20 s arrester 10 Surge voltage arrester Category C reflects the interference pulses with quick-rising edges and minimised power. Category D uses quick-rising edges and high power to detail the interference pulses. This energy simulates the high-power load that stems from coupled partial lightning currents. General technical data Storage temperature: -40 C ... +80 C Operating temperature: -40 C ...+70 C Humidity: 5 % ... 96 % 5 %...96 % RH without condensation Material: V0, IP 20 Connection: VSSC4 and VSSC6 Torx(R): T15 900917 Slotted: 0.8 x 4 (order number 9008340000) Nominal torque: 0.5 Nm Max. Drehmoment: 1 Nm Max. torque: 10 mm Solid core: 0.5...6 mm Stranded: 0.5 ... 4 mm Finely stranded: 0.5 .... 4 mm Finely stranded with ferrule: 0.5 .... 4 mm Dimensions VSSC4: Width: 6.1 mm Width with frame: 12.2 mm Height: 76 mm Depth: 58.5 mm with TS 35 x 7.5 Top connections: Unprotected: 1 Protected: 4 Bottom connections: Unprotected: 2 Protected: 3 VSSC6: Width: 6.1 mm Width with frame: 12.2 mm Height: 88.5 mm Depth: 81 mm with TS 35 x 7.5 Top connections: Unprotected: 1 Protected: 4 Mid-level connections: Unprotected: 2 Protected: 5 Bottom connections: Unprotected: 3 Protected: 6 118 Markers for VSSC4 and VSSC6: Dekafix: DEK 5 for the connections WS10/6 middle as device marker SNAPMARK only for the VSSC6 and DEK5/5 for the terminal points. Derating curves VSSC4 GDT MOV TAZ I/A 50 40 30 32 32 32 24 20 10 0 -40 C 0 C 55 C 70 C VSSC4 RC I/A 25 20 20 20 20 16 15 12 10 5 0 -40 C 0 C 30 C 50 C 70 C VSSC6 GDT MOV I/A 12.5 12 12 11.5 11 10.5 10 9.5 9 -40 C 12 12 10 0 C 55 C 70 C Other VSSC4 und VSS I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C 0 C 15 C 42.5 C 70 C VARITECTOR SSC - Overview Quick product selection for the VARITECTOR SSC Technical Data Interface 0(4) ... 20 mA / 0 ...10 V Product designation Part No. VSSC4 CL 24 V UC 0.5 A 1063730000 VSSC6 CL 24 V UC 0.5 A 1064170000 VSSC6TR CL FG 24 V UC 0.5 A 1064310000 VSSC4 CL FG 24 V UC 0.5 A 1063770000 VSSC6 CL FG 24 V UC 0.5 A 1064270000 VSSC6TR CL FG 24 V UC 0.5 A 1064310000 ARCNET (Plus) VSSC6 RS485 1064980000 BLN (Building Level Network) see 0(4) ... 20 mA / 0 ...10 V DeviceNet VSSC6 RS485 1064980000 DIN measurement bus see 0(4) ... 20 mA / 0 ...10 V Dupline / Miniplex VSSC6 CL 12 V DC 0.5 A 1064150000 EIB (European Instalation Bus) VSSC6 GDT 110 V UC 10 kA 1064690000 EIB (European Instalation Bus) VSSC6 GDT 110 V UC 20 kA 1064700000 ET200 VSSC6 CL 12 V DC 0.5 A 1064150000 Genius I/O Bus see 0(4) ... 20 mA / 0 ...10 V Hart see 0(4) ... 20 mA / 0 ...10 V Cathodic corrosion protection VSSC6 GDT 230 V UC 20 kA 1064720000 LONTM (Works) VSSC6 CL 48 V UC 0.5 A 1064190000 M-Bus (Remote meter reading) see 0(4) ... 20 mA / 0 ...10 V MPI Bus VSSC6 RS485 1064980000 N2 Bus VSSC6 SL LD 12 V DC 0.5 A 1064340000 Procontic CS31 VSSC6TR CL FG 12 V DC 0.5 A 1064300000 Profibus DP (FMS) VSSC6 RS485 DP PT100 VSSC6 RTD 1139710000 PSM-EG-RS422... VSSC6 RS485 DP 1065010000 PSM-EG-RS485... VSSC6 RS485 DP 1065010000 RS422A, V.11, X.27, RS423A VSSC6 RS485 DP 1065010000 RS485 VSSC6 RS485 DP 1065010000 RS232-C / V.24 VSSC6 RS232 1064990000 SecuriLan-LONTM-Bus see 0(4) ... 20 mA / 0 ...10 V (Profibus DP) VSSC6 RS485 DP 1065010000 TTY, 0(4) - 20 mA see 0(4) ... 20 mA / 0 ...10 V U-BUS VSSC6 GDT 110 V UC 20 kA 1064700000 Note: T his tables contains selection recommendations. Our technical consultants will be glad to assist you with your individual application requirements. 119 VARITECTOR SSC 6AN VARITECTOR SSC 6AN Lightning and surge protection in terminal block design Lightning and surge protection in 6 mm overall width for measurement and control circuits including isolation/ measuring function The VARITECTOR SSC combined surge protection, a direct PE contact function, separation of signal paths and operational status indication in one module. It is suitable for C&I applications. The disconnect lever in the terminal guarantees that the measurement/ control circuit can be quickly and precisely switched off to test the signal path. Using a test plug (PS 2.3 mm), the measuring instrument can be easily inserted into the integrated test socket on Torx(R)/Slot headed screws. The shield can be attached onto the additional lower level of the VSSC 6AN which then leads directly to the PE potential on the mounting rail. Permanent shielding can be implemented easily using the EMC set. Weidmuller's SNAPMARK device marker can be snapped onto a terminal so that the equipment identification can be easily read regardless of the installation position. The VSSC 6AN features all the advantages found in the VARITECTOR SSC product line: a thin 6.2 mm width, quick PE contact to rail (with up to 20 kA discharge capacity), simple color coding for quick identification, large-surface versatile markers, and the new Torx(R)/slot headed screw. All VARITECTOR products comply with the latest IEC 61643-21:2008 requirement for a new overstress mode and with categories D1, C3, C2 and C1 according to IEC 61643-22. Convenient Connection convenience is assured by a clamping rage of 0.5 mm to 6 mm with a Torx(R)/slot headed screw and a 0.8 Nm tightening torque. Space-saving A terminal of just 6.2 mm for two binary signals or one analog signals. Terminals can be fitted side by side. 120 VARITECTOR SSC 6AN Simple and precise isolation The disconnect lever guarantees a simple signal path disconnection and a safe disconnect point that is easy to see. Fast identification Versatile marking options: markers for equipment and terminals and SNAPMARK markers that are easy to read in any installation position. Testing and measuring To enable simple testing it is possible to insert the test plug (PS 2.3 mm) of the measuring instrument into the integrated test socket of the Torx(R)/slot headed screw. Easy and safe A shield can be mounted on both sides of the unit which will provide direct connection to PE. It features a very high discharge current of up to 20 kA for increased plant safety. 121 VARITECTOR SSC 6AN VSSC 6 CL and CL FG - protection for analog signals * Two-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 analog signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 2 5 3 6 TS UNPROTECTED PROTECTED 1 4 2 5 3 6 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 50 A 0,5 kA 2.5 kA / 2.5 kA / 5 kA / 5 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 19 6008 2 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) Note 122 0 C 15 C 42.5 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 CL and CL FG CL 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical CL 24 V UC CL 48 V UC CL 60 V UC 15 V 500 mA No No 700 kHz 20 ms 900 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 170 ms 900 V 48 V 68 V 60 V 85 V 500 mA No No 5 Mhz 150 ms 764 V 60 V 85 V 75 V 106 V 500 mA No No 6.8 MHz 20 ms 777 V VSSC6 CL 12VDC 0.5A 1064150000 10 ST VSSC6 CL 24VAC/DC 0.5A 1064170000 10 ST VSSC6 CL 48VAC/DC 0.5A 1064190000 10 ST VSSC6 CL 60VAC/DC 0.5A 1064210000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 CLFG 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 CLFG 24 V UC CLFG 48 V UC CLFG 60 V UC 15 V 500 mA No No 700 kHz 20 ms 1600 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 20 ms 1632 V 48 V 68 V 60 V 85 V 500 mA No No 5 Mhz 20 ms 1506 V 60 V 85 V 75 V 106 V 500 mA No No 6.8 MHz 20 ms 1512 V VSSC6 CL FG 12VDC 0.5A 1064260000 10 ST VSSC6 CLFG24VAC/DC0.5A 1064270000 10 ST VSSC6 CLFG48VAC/DC0.5A 1064280000 10 ST VSSC6 CLFG60VAC/DC0.5A 1064290000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 123 VARITECTOR SSC 6AN VSSC 6 TR CL and TR CL FG - protection for floating current loops * Two-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 analog signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 2 5 3 6 TS UNPROTECTED PROTECTED 1 4 2 5 3 6 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 50 A 10/1000 s 0.5 kA 10/350 s 2.5 kA / 2.5 kA / 5 kA / 5 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 19 6008 2 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) Note 124 0 C 15 C 42.5 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6TR CL and TR CL FG TR CL 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical TR CL 24 V UC TR CL 48 V UC TR CL 60 V UC 15 V 500 mA No Yes 270 Mhz 20 ms 900 V 24 V 34 V 30 V 42 V 500 mA No Yes 270 Mhz 170 ms 900 V 48 V 68 V 60 V 85 V 500 mA No Yes 270 Mhz 150 ms 764 V 60 V 85 V 75 V 106 V 500 mA No Yes 270 Mhz 20 ms 777 V VSSC6 TR CL 12VDC 0.5A 1064220000 10 ST VSSC6 TRCL24VAC/DC0.5A 1064230000 10 ST VSSC6 TRCL48VAC/DC0.5A 1064240000 10 ST VSSC6 TRCL60VAC/DC0.5A 1064250000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 TR CLFG 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 TR CLFG 24 V UC TR CLFG 48 V UC TR CLFG 60 V UC 15 V 500 mA No Yes 270 Mhz 20 ms 900 V 24 V 34 V 30 V 42 V 500 mA No Yes 270 Mhz 20 ms 1632 V 48 V 68 V 60 V 85 V 500 mA No Yes 270 Mhz 20 ms 1506 V 60 V 85 V 75 V 106 V 500 mA No Yes 270 Mhz 20 ms 1512 V VSSC6TRCLFG12VDC0.5A 1064300000 10 ST VSSC6TRCLFG24VAC/DC0.5A 1064310000 10 ST VSSC6TRCLFG48VAC/DC0.5A 1064320000 10 ST VSSC6TRCLFG60VAC/DC0.5A 1064330000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 125 VARITECTOR SSC 6AN VSSC 6 SL and SL FG - protection for binary signals with signal display * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: C1, C2 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED 1 4 3 6 2 5 TS UNPROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 10 A 10/1000 s 1 kA 10/350 s / 2.5 kA / / 10 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 54 2114 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 PROTECTED I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) Note 126 0 C 15 C 42.5 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 SL and SL FG SL LD 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical SL LD 24 V UC SL LD 48 V UC SL LD 60 V UC 15 V 500 mA Yes No 750 KHz 20 ms 74 V 24 V 34 V 30 V 42 V 500 mA Yes No 3.2 MHz 20 ms 110 V 48 V 68 V 60 V 85 V 500 mA Yes No 4.6 MHz 20 ms 174 V 60 V 85 V 75 V 106 V 500 mA Yes No 5.5 MHz 20 ms 222 V VSSC6SL LD 12VDC 0.5A 1064340000 10 ST VSSC6SL LD24VAC/DC0.5A 1064350000 10 ST VSSC6SL LD48VAC/DC0.5A 1064360000 10 ST VSSC6SL LD60VAC/DC0.5A 1064370000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 SLFG LD 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 SLFG LD 24 V UC SLFG LD 48 V UC SLFG LD 60 V UC 15 V 500 mA Yes No 750 KHz 20 ms 74 V 24 V 34 V 30 V 42 V 200 mA Yes No 3.2 MHz 20 ms 110 V 48 V 68 V 60 V 85 V 10 mA Yes No 4.6 MHz 20 ms 174 V 60 V 85 V 75 V 106 V 1.5 mA Yes No 5.5 MHz 20 ms 222 V VSSC6SL FG LD12VDC0.5A 1064420000 10 ST VSSC6SLFGLD24VAC/DC0.5A 1064430000 10 ST VSSC6SLFGLD48VAC/DC0.5A 1064440000 10 ST VSSC6SLFGLD60VAC/DC0.5A 1064470000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 127 VARITECTOR SSC 6AN VSSC 6 TR SL and TR SL FG - protection for floating signals with signal display * Two-stage surge protection with screw connection for measurement and control signals with signal display * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED 1 4 3 6 2 5 TS UNPROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 10 A 10/1000 s 1 kA 10/350 s / 2.5 kA / / 10 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 54 2114 3 CE; OEVE; TUEV; UL; ROHS IEC 61643-21 PROTECTED I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) Note 128 0 C 15 C 42.5 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 TR SL and TR CL FG TR SL LD 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical TR SL LD 24 V UC TR SL LD 48 V UC TR SL LD 60 V UC 15 V 500 mA Yes Yes 750 KHz 20 ms 74 V 24 V 34 V 30 V 42 V 500 mA Yes Yes 3.2 MHz 20 ms 110 V 48 V 68 V 60 V 85 V 500 mA Yes Yes 4.6 MHz 20 ms 174 V 60 V 85 V 75 V 106 V 500 mA Yes Yes 5.5 MHz 20 ms 222 V VSSC6TRSLLD12VDC0.5A 1064380000 10 ST VSSC6TRSLLD24VAC/DC0.5A 1064390000 10 ST VSSC6TRSLLD48VAC/DC0.5A 1064400000 10 ST VSSC6TRSLLD60VAC/DC0.5A 1064410000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 TR SLFG LD 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 TR SLFG LD 24 V UC TR SLFG LD 48 V UC TR SLFG LD 60 V UC 15 V 500 mA Yes Yes 750 KHz 20 ms 74 V 24 V 34 V 30 V 42 V 200 mA Yes Yes 3.2 MHz 20 ms 110 V 48 V 68 V 60 V 85 V 10 mA Yes Yes 4.6 MHz 20 ms 174 V 60 V 85 V 75 V 106 V 1.5 mA Yes Yes 5.5 MHz 20 ms 222 V VSSC6TRSLFGLD12VDC0.5A 1064490000 10 ST VSSC6TRSLFGLD24VUC 0.5A 1064500000 10 ST VSSC6TRSLFGLD48VUC 0.5A 1064510000 10 ST VSSC6TRSLFGLD60VUC 0.5A 1064520000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 129 VARITECTOR SSC 6AN VSSC 6 MOV - protection with Varistor (MOV) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: C1, C2 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 U 3 6 U 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Height x depth 12 A < 0.1 Mode 1 C1 According to IEC61643-21 0.25 kA 8/20 s 0.5 kV 1.2/50 s / 0.5 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 26 4391 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS According to IEC61643-21 I/A 12.5 12 12 12 12 11.5 11 10.5 10 10 9.5 9 -40 C Dimensions Height x depth (mm) Note 130 0 C 55 C 88.5 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 MOV MOV 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance Width MOV 24 V UC MOV 48 V UC MOV 60 V UC 15 V 12 A No No 24 V 34 V 30 V 42 V 12 A No No 48 V 60 V 60 V 85 V 12 A No No 60 V 85 V 75 V 106 V 12 A No No 57 V 10.8 nF 7.1 120 V 4.6 nF 7.1 213 V 2.0 nF 7.1 269 V 1.78 nF 7.1 VSSC6 MOV 12VDC 1064530000 8 ST VSSC6 MOV 24VAC/DC 1064540000 8 ST VSSC6 MOV 48VAC/DC 1064570000 8 ST VSSC6 MOV 60VAC/DC 1064600000 8 ST 12 V Ordering Data Type Part No. Qty. Note Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance Width End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 MOV 120 V UC MOV 150 V UC MOV 240 V UC 120 V 170 V 150 V 212 V 12 A No No 150 V 212 V 188 V 266 V 12 A No No 240 V 339 V 288 V 407 V 12 A No No 543 V 283 pF 12.2 641 V 0.8 nF 12.2 1022 V 0.5 nF 12.2 VSSC6 MOV 120VAC/DC 1064610000 5 ST VSSC6 MOV 150VAC/DC 1064620000 5 ST VSSC6 MOV 240VAC/DC 1064630000 5 ST End plate AP VSSC6 1063110000 Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 131 VARITECTOR SSC 6AN VSSC 6 TR LD MOV - protection with varistor (MOV) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: C1, C2 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 4 1 U 3 6 U 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 12 A < 0.1 Mode 1 C1 IEC 61643-21 0.25 kA 8/20 s 0.5 kV 1.2/50 s / 0.5 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 37 3085 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 I/A 12.5 12 12 12 12 11.5 11 10.5 10 10 9.5 9 -40 C Dimensions Height x depth (mm) Note 132 0 C 55 C 88.5 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 TR LD MOV TR LD MOV 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance Width TR LD MOV 24 V UC TR LD MOV 48 V UC TR LD MOV 60 V UC 15 V 12 A Yes Yes 24 V 34 V 30 V 42 V 12 A Yes Yes 48 V 68 V 60 V 85 V 12 A Yes Yes 60 V 85 V 75 V 106 V 12 A Yes Yes 57 V 10.8 nF 7.1 120 V 4.6 nF 7.1 213 V 2.0 nF 7.1 269 V 1.78 nF 7.1 VSSC6 TRLDMOV 12VDC 1064800000 8 ST VSSC6 TRLDMOV 24VAC/DC 1064810000 8 ST VSSC6 TRLDMOV 48VAC/DC 1064820000 8 ST VSSC6 TRLDMOV60VAC/DC 1064830000 8 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance Width End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 TR LD MOV 120 V UC TR LD MOV 150 V UC TR LD MOV 240 V UC 120 V 170 V 150 V 212 V 12 A Yes Yes 150 V 212 V 188 V 266 V 12 A Yes Yes 240 V 339 V 288 V 407 V 12 A Yes Yes 543 V 283 pF 12.2 641 V 0.8 nF 12.2 1022 V 0.5 nF 12.2 VSSC6 TRLDMOV120VAC/DC 1064840000 5 ST VSSC6 TRLDMOV150VAC/DC 1064850000 5 ST VSSC6 TRLDMOV240VAC/DC 1064860000 5 ST End plate AP VSSC6 1063110000 Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 133 VARITECTOR SSC 6AN VSSC 6 GDT - protection with sparkover gap (GDT) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 12.4 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 12 A < 0.1 Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 50 A 10/1000 s 1 kA 10/350 s / 2.5 kA / / 10 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 10 11416 3 CE; GOSTME25; TUEV; ROHS IEC 61643-21 I/A 12.5 12 12 12 12 11.5 11 10.5 10 10 9.5 9 -40 C Dimensions Height x width x depth (mm) Note 134 0 C 55 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 GDT Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance GDT 24 V UC 10 kA GDT 110 V UC 10 kA GDT 240 V UC 10 kA GDT 24 V UC 20 kA 24 V 34 V 30 V 42 V 12 A No No 110 V 156 V 138 V 195 V 12 A No No 240 V 339 V 288 V 407 V 12 A No No 24 V 34 V 30 V 42 V 12 A No No 976 V 1.5 nF 1153 V 4.2 nF 1792 V 3.0 nF 949 V 5.3 nF VSSC6 GDT 24VAC/DC 10kA 1064640000 10 ST VSSC6 GDT 110VAC/DC10kA 1064690000 10 ST VSSC6 GDT 240VAC/DC10kA 1064710000 5 ST VSSC6 GDT 24VAC/DC 20kA 1064670000 5 ST Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance End plate AP VSSC6 1063110000 GDT 110 V UC 20 kA GDT 240 V UC 20 kA 110 V 156 V 138 V 195 V 12 A No No 240 V 339 V 288 V 407 V 12 A No No 992 V 2.5 nF 1288 V 2.4 nF VSSC6 GDT 110VAC/DC20kA 1064700000 5 ST VSSC6 GDT 240VAC/DC20kA 1064720000 5 ST End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 135 VARITECTOR SSC 6AN VSSC 6 TR GDT - protection with sparkover gap (GDT) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm or 12.4 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 12 A < 0.1 Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 50 A 10/1000 s 1 kA 10/350 s / 2.5 kA / / 10 kA / / 1 kA / -40 C...+80 C -40 C...+80 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 10 11416 3 CE; GOSTME25; TUEV; ROHS IEC 61643-21 I/A 12.5 12 12 12 12 11.5 11 10.5 10 10 9.5 9 -40 C Dimensions Height x width x depth (mm) Note 136 0 C 55 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 TR GDT Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance TR GDT 24 V UC 10 kA TR GDT 110 V UC 10 kA TR GDT 240 V UC 10 kA 24 V 34 V 30 V 42 V 12 A No Yes 110 V 156 V 138 V 195 V 12 A No Yes 240 V 339 V 288 V 407 V 12 A No Yes 976 V 1.5 nF 1153 V 4.2 nF 1792 V 3.0 nF VSSC6TRGDT24VAC/DC10kA 1064870000 10 ST VSSC6TRGDT110VAC/DC10kA 1064890000 10 ST VSSC6TRGDT240VAC/DC10kA 1064920000 5 ST Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 137 VARITECTOR SSC 6AN VSSC 6 TAZ and TR TAZ - suppressor diode, with and without isolation option (TR) * Two-stage surge protection with screw connection for PROFIBUS RS422/485 data interfaces * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 2 6 5 TS UNPROTECTED PROTECTED 1 4 3 6 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 12 A < 0.1 Mode 1 C3 According to IEC61643-21 50 A 10/1000 s / 0.2 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 32 3567 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS According to IEC61643-21 I/A 12.5 12 12 12 12 11.5 11 10.5 10 10 9.5 9 -40 C Dimensions Height x width x depth (mm) Note 138 0 C 55 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 TAZ and TR LD TAZ TAZ 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Residual voltage, UP typical Capacitance TAZ 24 V UC TAZ 48 V UC TAZ 60 V UC 15 V 12 A No No 26 V 4.9 pF 24 V 34 V 30 V 42 V 12 A No No 62 V 0.8 nF 48 V 68 V 60 V 85 V 12 A No No 85 V 0.4 nF 60 V 85 V 75 V 106 V 12 A No No 100 V 0.3 nF VSSC6 TAZ 12VDC 1064730000 10 ST VSSC6 TAZ 24VAC/DC 1064740000 10 ST VSSC6 TAZ 48VAC/DC 1064770000 10 ST VSSC6 TAZ 60VAC/DC 1064790000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 TR LD TAZ 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Residual voltage, UP typical Capacitance End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 TR LD TAZ 24 V UC TR LD TAZ 48 V UC TR LD TAZ 60 V UC 15 V 12 A Yes Yes 26 V 4.8 nF 24 V 34 V 30 V 42 V 12 A Yes Yes 62 V 0.8 nF 48 V 68 V 60 V 85 V 12 A Yes Yes 85 V 0.4 nF 60 V 85 V 75 V 106 V 12 A Yes Yes 100 V 0.3 nF VSSC6 TRLDTAZ 12VDC 1064940000 10 ST VSSC6 TRLDTAZ 24VAC/DC 1064950000 10 ST VSSC6 TRLDTAZ 48VAC/DC 1064960000 10 ST VSSC6 TRLDTAZ 60VAC/DC 1064970000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 139 VARITECTOR SSC 6AN VSSC 6 RS485 - protection for RS232/RS485 signal interfaces * Two-stage surge protection with screw connection for RS422/RS485 data interfaces * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED 1 4 3 6 2 5 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 10 A 10/1000 s 0.5 kA 10/350 s 2.5 kA / 2.5 kA / 10 kA / 10 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 60 1903 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) Note 140 0 C 15 C 42.5 C 88.5 / 6.1 / 81 TU 70 C VARITECTOR SSC 6AN VSSC 6 RS485, RS485 DP and RS232 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical RS485 RS485 DP RS232 12 V 12 V 12 V 15 V 500 mA No No 113.6 MHz 15 ms 94 V 15 V 500 mA No No 113.6 MHz 15 ms 94 V 15 V 500 mA No No 1.4 MHz 15 ms 80 V VSSC6 RS485 1064980000 10 ST VSSC6 RS485 DP 1065010000 10 ST VSSC6 RS232 1064990000 10 ST Ordering Data Type Part No. Qty. Note End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 141 VARITECTOR SSC 6AN VSSC 6 RTD - protection for PT100 signal interfaces * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for two signals * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: C1, C2 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 4 1 2 5 3 6 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Dimensions Height x width x depth (mm) Note 142 300 mA 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 10 A 10/1000 s 0.5 kA 10/350 s 2.5 kA / 2.5 kA / 5 kA / 5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 63 1812 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 88.5 / 6.1 / 81 VARITECTOR SSC 6AN VSSC 6 RTD RTD Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Residual voltage, UP typical 1V 5V 300 mA No 113.6 MHz 126 V Ordering Data Type Part No. Qty. Note VSSC6 RTD 1139710000 10 ST End plate AP VSSC6 1063110000 143 VARITECTOR SSC 4AN VARITECTOR SSC Lightning and surge protection in terminal block design The new and comprehensive surge protection family for measurement and control technology in 6 mm overall width The interfaces in C&I applications must be protected against surges, since coupling of surges on lines can interfere with or destroy signal inputs. It is therefore necessary that C&I devices be protected in their immediate vicinity. For this purpose, VARITECTOR SSC, with its compact terminal-block format, is ideal for this application. The protective circuits are matched to the current loops and to binary signals. The VARITECTOR SSC products are tested according to the latest standards (IEC61643-21): They satisfy the safe short-circuit mode in the event of overload by AC currents in classes D1, C2 and C1. The products are ATEX-tested for use in intrinsically safe circuits. Easy to use The clamping area of 0.5 mm - 6 mm is covered with combined Torx(R)/Slot headed screw and a tightening torque of 0.8 Nm. Space-saving Modular width of terminals just 6.2 mm for two binary signals or per analog signal. 144 VARITECTOR SSC 4AN Large variety A solution for every type of surge protection: More than 100 variations: current loops and binary signals for 5 V, 12 V, 24 V, 48 V and 60 V, with integrated components, e.g. varistors. Quick identification Large-area marking options: marking of devices and single connections as well as colorcoded marking of the voltage levels for fast identification in the switching cabinet. Simple and safe Simple installation and high safety through direct PE contact when mounting on the terminal rail, with a very high discharge current of up to 20 kA. 145 VARITECTOR SSC 4AN VSSC 4 CL and CL FG - protection for current loops * Two-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 analog signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 3 2 4 TS UNPROTECTED PROTECTED 1 3 2 4 TS UNPROTECTED PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 50 A 10/1000 s 0.5 kA 10/350 s 2.5 kA / 2.5 kA / 5 kA / 5 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 19 6008 2 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 1 Load current I [A] 0.8 0.6 0.4 0.4 0.2 0 -40 0 15 42.5 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 146 76 / 6.1 / 58.5 70 VARITECTOR SSC 4AN VSSC 4 CL and CL FG VSSC4 CL 12 V DC 0.5 A Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical VSSC4 CL 24 V UC 0.5 A VSSC4 CL 48 V UC 0.5 A VSSC4 CL 60 V UC 0.5 A 15 V 500 mA No No 750 KHz 20 ms 912 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 150 ms 918 V 48 V 68 V 60 V 85 V 500 mA No No 5 Mhz 110 ms 773 V 60 V 85 V 75 V 106 V 500 mA No No 6.8 MHz 20 ms 770 V VSSC4 CL 12VDC 0.5A 1063720000 10 ST VSSC4 CL 24VAC/DC 0.5A 1063730000 10 ST VSSC4 CL 48VAC/DC 0.5A 1063740000 10 ST VSSC4 CL 60VAC/DC 0.5A 1063750000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 VSSC4 CL FG 12 V DC 0.5 A Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 VSSC4 CL FG 24 V UC 0.5 A VSSC4 CL FG 48 V UC 0.5 A VSSC4 CL FG 60 V UC 0.5 A 15 V 500 mA No No 750 KHz 20 ms 1434 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 20 ms 1407 V 48 V 68 V 60 V 85 V 500 mA No No 5 Mhz 20 ms 1419 V 60 V 85 V 75 V 106 V 500 mA No No 6.8 MHz 20 ms 1398 V VSSC4 CL FG 12VDC 0.5A 1063760000 10 ST VSSC4 CL FG24VAC/DC0.5A 1063770000 10 ST VSSC4 CL FG48VAC/DC0.5A 1063780000 10 ST VSSC4 CL FG60VAC/DC0.5A 1063790000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 147 VARITECTOR SSC 4AN VSSC 4 SL and SL FG - protection for binary signal * Two-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 binary signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 3 2 4 TS UNPROTECTED PROTECTED VSSC4 SL 1 3 2 4 TS UNPROTECTED VSSC SL FG PROTECTED Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 500 V 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 10 A 10/1000 s 1 kA 10/350 s / 2.5 kA / / 10 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 43 2655 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 1 Load current I [A] 0.8 0.6 0.4 0.4 0.2 0 -40 0 15 42.5 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 148 76 / 6.2 / 58.5 70 VARITECTOR SSC 4AN VSSC 4 SL and SL FG VSSC4 SL 12 V DC 0.5 A Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical VSSC4 SL 24 V UC 0.5 A VSSC4 SL 48 V UC 0.5 A VSSC4 SL 60 V UC 0.5 A 15 V 500 mA No No 860 KHz 20 ms 66 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 35 ms 106 V 48 V 68 V 60 V 85 V 500 mA No No 5.2 MHz 20 ms 160 V 60 V 85 V 75 V 106 V 500 mA No No 6.6 MHz 20 ms 223 V VSSC4 SL 12VDC 0.5A 1063830000 10 ST VSSC4 SL 24VAC/DC 0.5A 1063840000 10 ST VSSC4 SL 48VAC/DC 0.5A 1063860000 10 ST VSSC4 SL 60VAC/DC 0.5A 1063870000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 VSSC4 SL FG 12 V DC 0.5 A Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 VSSC4 SL FG 24 V UC 0.5 A VSSC4 SL FG 48 V UC 0.5 A VSSC4 SL FG 60 V UC 0.5 A 15 V 500 mA No No 860 KHz 20 ms 66 V 24 V 34 V 30 V 42 V 500 mA No No 3.4 MHz 20 ms 106 V 48 V 68 V 60 V 85 V 500 mA No No 5.2 MHz 35 ms 160 V 60 V 85 V 75 V 106 V 500 mA No No 6.6 MHz 20 ms 223 V VSSC4 SL FG 12VDC 0.5A 1063880000 10 ST VSSC4 SL FG24VAC/DC0.5A 1063890000 10 ST VSSC4 SL FG48VAC/DC0.5A 1063910000 10 ST VSSC4 SL FG60VAC/DC0.5A 1063920000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 149 VARITECTOR SSC 4AN VSSC 4 MOV - protection with Varistor (MOV) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for one signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 : C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 3 1 U 2 4 TS VSSC4 MOV Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 32 A < 0.1 Mode 1 C1 IEC 61643-21 0.25 kA 8/20 s 0.5 kV 1.2/50 s 1 kA 8/20 s / 0.5 kA / / 1 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 26 4391 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 50 Load current I [A] 40 30 24 20 10 0 -40 0 55 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 150 76 / 6.1 / 58.5 70 VARITECTOR SSC 4AN VSSC MOV 4 - components VSSC4 MOV 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Requirements category acc. to IEC 61643-21 Pulse-reset capacity Residual voltage, UP typical Capacitance VSSC4 MOV 24 V UC VSSC4 MOV 48 V UC VSSC4 MOV 60 V UC 15 V 32 A No No C1 24 V 34 V 30 V 42 V 32 A No No C1 48 V 68 V 60 V 85 V 32 A No No C1, C2 60 V 85 V 75 V 106 V 32 A No No C1, C2 55 V 11.2 nF 116 V 4.8 nF 206 V 1.9 nF 246 V 1.7 nF VSSC4 MOV 12VDC 1063950000 10 ST VSSC4 MOV 24VAC/DC 1063960000 10 ST VSSC4 MOV 48VAC/DC 1063970000 10 ST VSSC4 MOV 60VAC/DC 1063980000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Requirements category acc. to IEC 61643-21 Pulse-reset capacity Residual voltage, UP typical Capacitance End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 VSSC4 MOV 120 V UC VSSC4 MOV 150 V UC VSSC4 MOV 240 V UC 120 V 170 V 150 V 212 V 32 A No No C1, C2 150 V 212 V 188 V 266 V 32 A No No C1, C2 240 V 339 V 288 V 407 V 32 A No No C1, C2 526 V 1.48 nF 638 V 0.97 nF 1022 V 0.7 nF VSSC4 MOV 120VAC/DC 1063990000 5 ST VSSC4 MOV 150VAC/DC 1064010000 5 ST VSSC4 MOV 240VAC/DC 1064020000 5 ST End plate AP VSSC4 1063120000 Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 151 VARITECTOR SSC 4AN VSSC 4 GDT - protection with sparkover gap (GDT) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 12.4 mm * Space-saving design for one signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 : C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 3 2 4 TS VSSC4 GDT Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 32 A < 0.1 Modus 2 C2, C3, D1 IEC 61643-21 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s / 5 kA / / 20 kA / / 2.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 10 11416 3 CE; GOSTME25; TUEV; ROHS IEC 61643-21 50 Load current I [A] 40 30 24 20 10 0 -40 0 55 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 152 76 / 12.2 / 58.5 70 VARITECTOR SSC 4AN VSSC 4 GDT - components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Residual voltage, UP typical Capacitance VSSC4 GDT 110 V UC 20 kA VSSC4 GDT 240 V UC 20 kA 110 V 156 V 138 V 195 V 32 A No No 845 V 4.65 pF 240 V 339 V 288 V 407 V 32 A No No 1144 V 4.65 pF VSSC4 GDT 110VAC/DC20kA 1064050000 5 ST VSSC4 GDT 240VAC/DC20kA 1064060000 5 ST Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 153 VARITECTOR SSC 4AN VSSC 4 TAZ - protection with suppressor diode (TAZ) * One-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design for one signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 : C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 3 1 2 4 TS VSSC4 TAZ Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 32 A < 0.1 Mode 1 C3 IEC 61643-21 / 0.2 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 32 3567 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 50 Load current I [A] 40 30 24 20 10 0 -40 0 55 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 154 76 / 6.1 / 58.5 70 VARITECTOR SSC 4AN VSSC 4 TAZ - components VSSC4 TAZ 12 V DC Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Residual voltage, UP typical Capacitance Surge current-carrying capacity C3 VSSC4 TAZ 24 V UC VSSC4 TAZ 48 V UC VSSC4 TAZ 60 V UC 15 V 32 A No No 22 V 5.06 nF 50 A 24 V 34 V 30 V 42 V 32 A No No 61 V 0.82 nF 15 A 48 V 75 V 60 V 85 V 32 A No No 80 V 0.45 nF 15 A 60 V 85 V 75 V 106 V 32 A No No 100 V 0.36 nF 15 A VSSC4 TAZ 12VDC 1064070000 10 ST VSSC4 TAZ 24VAC/DC 1064080000 10 ST VSSC4 TAZ 48VAC/DC 1064090000 10 ST VSSC4 TAZ 60VAC/DC 1064110000 10 ST 12 V Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 155 VARITECTOR SSC 4AN VSSC 4 RC - protection with a combination of resistors and capacitors * Two-stage surge protection with screw connection for measurement and control signals * Surge protection in terminal block design * Modular width of only 12.4 mm * Space-saving design for one signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 3 1 U 2 VSSC4 RC 4 Rated current Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 20 A < 0.1 Mode 1 C1 IEC 61643-21 0.25 kA 8/20 s 0.5 kV 1.2/50 s / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 28 4048 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 25 Load current I [A] 20 15 12 10 5 0 -40 0 30 50 Ambient temperature T [C] Dimensions Height x width x depth (mm) Note 156 76 / 12.2 / 58.5 70 VARITECTOR SSC 4AN VSSC 4 RC - components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Optical function display Isolating function Input attenuation Pulse-reset capacity Residual voltage, UP typical Capacitance VSSC4 RC 24 V UC VSSC4 RC 240 V UC 24 V 34 V 30 V 42 V 20 A No No 240 V 339 V 275 V 388 V 20 A No No 119 V 8.5 nF 500 V 15.9 nF VSSC4 RC 24VAC/DC 1064120000 5 ST VSSC4 RC 240VAC/DC 1064130000 5 ST Ordering Data Type Part No. Qty. Note End plate AP VSSC4 1063120000 End plate AP VSSC4 1063120000 157 Surge protection for data signals Surge Protection for Data Signals RS 232 Serial interface for point-to-point connections up to 20 kbit/s Voltage signal to earth: logic 1 (mark) -15 V to -3 V logic 0 (space) +3 V to +15 V max. signal level 15 V Lines up to 20 m long depending on transmission rate. RS 232 RS 422 Serial uni-directional high-speed interface for up to 10 parallel receivers Differential voltage signal: logic 1 (mark) A-B < -0.3 V logic 0 (space) A-B > +0.3 V max. signal level 12 V Lines up to 1200 m long max. data rate 10 Mbit/s RS485 Serial bi-directional high-speed interface for up to 32 subscribers 2- or 4-wire system Differential voltage signal: logic 1 (mark) A-B < -0.3 V logic 0 (space) A-B > +0.3 V max. signal level -7 V to +12 V Lines up to 1200 m long max. data rate 10 Mbit/s 158 RS 422 RS485 Protection module in terminal housing VSSC 6 / RS232 Page 169 Protection module in plug-in housing VSPC / RS485 Page 163 Protection module in plug-in housing VSPC / RS485 R Page 165 Protection module in terminal housing VSSC 6 / RS485 VSSC 6 / RS485 DP Page 169 Surge protection for data interfaces VSPC 2CL HF - protection for two analog high-frequency signals * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 2 analog signals with optional alert function * Usable in accordance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 11 GND 12 7 8 9 10 GND 3 TS 5 4 6 1 2 unprotected protected Complete module, direct earthing 11 GND 12 7 8 9 10 GND 3 TS 5 1 unprotected 2 protected 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing 4 6 Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters 90 / 17.8 / 69 The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note Type VSPC BASE 2CL VSPC BASE 2CL FG Qty. 1 1 Part No. 8924710000 8924270000 Technical data can be found on page 106. 159 Surge protection for data interfaces VSPC 2CL HF - arrester / plug-in components Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 24 V DC 5V 12 V 24 V 6.4 V 450 mA 103 MHz 20 ms 800 V 15 V 450 mA 104 MHz 80 ms 800 V 28 V 450 mA 109 MHz 40 ms 800 V 12 V 12 V 450 V 800 V 25 V 25 V 450 V 800 V 45 V 45 V 450 V 800 V VSPC 2CL HF 5VDC 8924430000 1 ST VSPC 2CL HF 12VDC 8924460000 1 ST VSPC 2CL HF 24VDC 8924510000 1 ST Ordering Data No function display Note 160 Type Part No. Qty. Surge protection for data interfaces VSPC 2CL HF - protection for two analog high-frequency signals with remote alert * Optional monitoring function with status indicator and alert function * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Version with floating-earth PE connection for avoiding voltage potential differences * Space-saving design for 2 analog signals with optional alert function * Usable in accordance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21:08 D1, C1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 10 GND OK FAULT 3 X2 X1 4 TS 5 6 1 2 unprotected protected Complete module, direct earthing, with remote alert 11 12 7 GND 8 9 10 GND OK FAULT 3 5 6 1 unprotected X2 X1 4 TS 2 protected 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 45 2537 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 Current [mA] Complete module, indirect earthing, with remote alert Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards Temperature [C] Dimensions of complete module (arrester + base element) with remote signalling (R) Height x width x depth (mm) Note Base elements / base to arresters 98 / 17.8 / 69 The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note Type VSPC BASE 2CL FG R VSPC BASE 2CL R Qty. 1 1 Part No. 8951720000 8951710000 Technical data can be found on page 106. Order with VSPC CONTROL UNIT. 161 Surge protection for data interfaces VSPC 2CL HF - arrester / plug-in components with remote alert Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Optical function display Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically VSPC 2CL HF 5 V DC R VSPC 2CL HF 12 V DC R VSPC 2CL HF 24 V DC R 5V 12 V 24 V 6.4 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 15 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT 28 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace green = OK; red = arrester is defective - replace 103 MHz 20 ms 800 V 104 MHz 80 ms 800 V 109 MHz 40 ms 800 V 12 V 12 V 450 V 800 V 25 V 25 V 450 V 800 V 45 V 45 V 450 V 800 V VSPC 2CL HF 5VDC R 8951680000 1 ST VSPC 2CL HF 12VDC R 8951690000 1 ST VSPC 2CL HF 24VDC R 8951700000 1 ST Ordering Data With functional display Note 162 Type Part No. Qty. Surge protection for data interfaces VSPC RS485 * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status indicator and alert functions * Lower residual voltage * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 3 unprotected 10 GND TS 4 5 6 1 2 protected Complete module, direct earthing GND 11 12 7 8 9 10 GND 3 unprotected TS 4 5 6 1 2 Complete module, indirect earthing protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 57 2003 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,5 0,45 0,4 Current [mA] 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [C] Dimensions of complete module (arrester + base element) no remote sig. contact Height x width x depth (mm) Note Base elements / base to arresters mm 90 / 17.8 / 69 The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. Ordering Data (for base) Description Base element, direct earthing Base element, indirect earthing / floating earth FG Note Type VSPC BASE 2CL VSPC BASE 2CL FG Qty. 1 1 Part No. 8924710000 8924270000 Technical data can be found on page 106. 163 Surge protection for data interfaces VSPC RS485 - arrester / plug-in components VSPC RS485 2CH Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 5V 6.4 V 450 mA 113.6 MHz 20 ms 35 V 10 V 15 V 10 V 35 V Ordering Data No function display Note 164 Type Part No. Qty. VSPC RS485 2CH 8924670000 1 ST Surge protection for data interfaces VSPC RS485 with remote alert * Pluggable arrester (impedance-neutral plugging/unplugging without interruption) * Can be tested with the V-TEST testing device * Optional monitoring function with status indicator and alert functions * Lower residual voltage * Version with floating-earth PE connection for avoiding voltage potential differences * Tested in accordance with IEC 61643-21:08 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data GND 11 12 7 8 9 10 GND OK FAULT 3 unprotected X2 X1 4 TS 5 6 1 2 protected Complete module, direct earthing, with remote alert GND 11 12 7 8 9 10 GND OK FAULT 3 unprotected TS X2 X1 4 5 6 1 2 Complete module, indirect earthing, with remote alert protected Dielectric strength at FG against PE Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 V 2.20 Modus 2 C1, C2, C3, D1 < 1 kA 8/20 s 5 kA 8/20 s 100 A 10/1000 s 2.5 kA 10/350 s 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 C...+80 C -40 C...+70 C IP 20 90 1266 3 CE; GOSTME25; OEVE; TUEV; UL IEC 61643-21 0,5 0,45 0,4 Current [mA] 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [C] Base elements / base to arresters Dimensions of complete module (arrester + base element) Height x width x depth (mm) with remote signalling (R) Note The associated VSPC base element should be ordered with this. The dimension information provided refers to the complete module. 98 / 17.8 / 69 Ordering Data (for base) Description Base element, indirect earthing with remote contact Base element, direct earthing with remote contact Note Type VSPC BASE 2/4CH FG R VSPC BASE 2/4CH R Qty. 1 1 Part No. 8951800000 8951790000 Technical data can be found on page 107. Order with VSPC CONTROL UNIT. 165 Surge protection for data interfaces VSPC RS485 - arrester / plug-in components with remote alert VSPC RS485 2CH R Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact 5V 6.4 V 450 mA UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester is defective - replace Optical function display 113.6 MHz 20 ms 35 V Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically 10 V 15 V 10 V 35 V Ordering Data With functional display Note 166 Type Part No. Qty. VSPC RS485 2CH R 8951670000 1 ST Surge protection for data interfaces V DATA Cat.6 - surge protection for 8 wires with RJ45 socket * RJ45 connection * All 4 lines are protected * Robust and compact metal housing * Suitable for Cat.5 (to 100 MHz) and Cat.6 to 250 Mhz (class E) * Suitable for PoE (IEEE 802.3af) and PoE + (IEEE 802.3at) Technical Data 5- ,1 5- 287 Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Type of connection Storage temperature Ambient temperature (operational) Protection degree Approvals Approvals Standards C2, D1 5 kA 1 kA 5 kA / 5 kA / 5 kA 10 kA / 5 kA 1 kA / 1 kA / 1 kA RJ45-Port -40 ... +85C -40 C...+80 C IP 20 According to IEC61643-21 Dimensions of complete module (arrester + base element) Height x width x depth (mm) 75 / 19 / 46 Note Can also be used for Cat.5 applications 167 Surge protection for data interfaces V DATA Cat.6 - surge protection for 8 wires with RJ45 socket V DATA CAT6 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Input attenuation Pulse-reset capacity Residual voltage, UP typical 60 V 1A 250 kHz 550 V Ordering Data Type Part No. Qty. Note 168 VDATA CAT6 1348590000 1 ST Surge protection for data interfaces VSSC 6AN RS485, RS485 DP and RS232 - for interface signals * Two-stage surge protection with screw connection for RS422/RS485 data interfaces * Surge protection in terminal block design * Modular width of only 6.2 mm * Space-saving design: 1 signal * Torx(R) slotted screw connection * Can be used in compliance with installation standard IEC 62305 * Tested in accordance with IEC 61643-21: D1, C2, C3 * Integrated PE foot, safely discharges up to 20 kA (8/20 s) and 2.5 kA (10/350 s) to PE Technical Data 1 4 3 6 2 5 TS UNPROTECTED PROTECTED 1 4 3 6 2 5 TS UNPROTECTED PROTECTED Rated current Volume resistance Overload - failure mode Requirements category acc. to IEC 61643-21 Standards Surge current-carrying capacity C1 Surge current-carrying capacity C2 Surge current-carrying capacity C3 Surge current-carrying capacity D1 Discharge current In (8/20 s) wire-wire/wire-PE/GND-PE Discharge Imax (8/20 s) wire-wire/wire-PE/GND-PE Lightning test Iimp (10/350 s) wire-wire/wire-PE/GND-PE Storage temperature Ambient temperature (operational) Protection degree UL 94 flammability rating Connection data Type of connection Tightening torque Wire connection cross section, finely stranded, max. Wire connection cross-section, finely stranded, min. Wire cross-section, solid, max. Wire cross-section, solid, min. Wire cross-section, stranded, max. Wire cross-section, stranded, min. Stripping length Mounting rail Failure probability ges MTTF SIL in compliance with IEC 61508 Approvals Approvals Standards 500 mA 1.8 10 % Modus 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 s 5 kV 1.2/50 s 10 A 10/1000 s 0.5 kA 10/350 s 2.5 kA / 2.5 kA / 10 kA / 10 kA / / 0.5 kA / -40 C...+80 C -40 C...+70 C IP 20 V-0 Screw connection, Torx(R) T15, Slotted 0.8 x 4 0.5 Nm 4 mm 0.5 mm 6 mm 0.5 mm 4 mm 0.5 mm 10 mm TS 35 60 1903 3 CE; GOSTME25; OEVE; TUEV; UL; ROHS IEC 61643-21 I/A 1 0.8 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.2 0 -40 C Dimensions Height x width x depth (mm) 0 C 15 C 42.5 C TU 70 C 88.5 / 6.1 / 81 Note 169 Surge protection for data interfaces VSSC 6AN RS485, RS485 DP and RS232 Technical Data Rated voltage (AC) Rated voltage (DC) Max. continuous voltage, Uc (AC) Max. continuous voltage, Uc (DC) Rated current Signalling contact Input attenuation Pulse-reset capacity Residual voltage, UP typical Protection level Wire-wire 1 kV/s, typically Wire-wire 8/20 s, typically Wire-PE 1kV/s, typically Wire-PE 8/20 s, typically RS485 RS485 DP RS232 12 V 12 V 12 V 15 V 500 mA No 113.6 MHz 15 ms 94 V 15 V 500 mA No 113.6 MHz 15 ms 94 V 15 V 500 mA No 1.4 MHz 15 ms 80 V 94 V 94 V 80 V VSSC6 RS485 1064980000 10 ST VSSC6 RS485 DP 1065010000 10 ST VSSC6 RS232 1064990000 10 ST Ordering Data Type Part No. Qty. Note 170 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 End plate AP VSSC6 1063110000 Surge Protection - MTL Surge Protection - MTL SD Series SLP Series Data and Signal Protection The SD Series are ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling, and the SLP Series provides 20kA power surge protection for process control, equipment systems and distribution panels. MA15 Series AC & DC Power Protection Product Features: * Range of ATEX Certified intrinsically safe surge protectors * Ultra-slim and space saving designs; easy installation * Multistage hybrid protection circuitry - 20kA maximum surge current * Range of voltage ratings ideal for process I/O applications * Designed for high bandwidth, low resistance applications; RTD, Public Switch Telephone Network (PSTN) and 3-wire transmitter versions available in SD Series * Surge protection for two loops or one 4-wire circuit per SLP Series module * 10 year product warranty The MA15 Series of surge protection devices protects electronic equipment and computer networks against the effects of noise pollution induced in power supplies. MA15 units filter out and suppress the effects of industrial noise and surges caused by lightning, switching devices, thyristor controls, transmission system overloads and power-factor correction circuits. The SD and SLP Series surge protection devices provide unparalleled packing densities, application versatility, proven and reliable hybrid circuitry, simple installation and optional `loop disconnect' facilities (SD Series). These features make the SD and SLP Series the ultimate surge protection solutions for process control equipment, I/O systems and communications networks. Product Features: TP48 Series Transmitter and Sensor Protection * 18kA surge protection and RFI filtering * Protects panel loads up to 15 Amps in series, unlimited Amps in parallel * Suitable for AC or DC application * Thermal and short circuit protection * LED status indication feature * 10 year product warranty * UL 1449 3rd Edition The TP48 Series of transmitter protectors safeguards electronic process transmitters against induced surges and transients from field cabling. They uniquely provide a level of protection for 2, 3 and 4 wire field-mounted transmitters that greatly exceeds the optional transient protection facilities available from the transmitter manufacturers without any additional wiring, conduit modifications or other expensive extras. Product Features: * Easy and direct mounting - simply screw into spare conduit entry * Intrinsically safe; flameproof to CENELEC standards; ATEX approved * Parallel connection avoids introduction of resistance into loop * 10 year product warranty 171 Surge Protection - MTL SD Series SLP Series The exceptionally high packing densities are the result of an ultra slim footprint for individual modules, which can double-up as feedback terminals. Each module provides full hybrid surge protection for 2 and 3-wire loop protection. The multi-stage hybrid surge protection network at the heart of the SLP uses a combination of solid state electronics and a gas filled discharge tube (GDT) to provide surge protection up to 20kA. This impressive surge protection circuit is designed to exhibit exceptionally low line resistance and adds only a minimal voltage drop to the circuit. Modules with a comprehensive range of voltage ratings cover all process related signals such as RTDs, Thermocouples (THCs), 4 - 20mA loops, telemetry outstations, shut-down systems and fire and gas detectors. The optional loop disconnect featured on the SD07, SD16, SD32 and SD55 modules allows users to perform commissioning and maintenance without removing the surge protection device. In addition, a third connection on the field and safe side of the module is provided for safe termination of shields. For three wire applications the specially designed SDRTD (Resistance Temperature Detector) and the SD32T3, (for separately powered 4 - 20mA loops) provide full 3-wire protection in a single compact unit. The SD07R3 provides protection of 3-wire pressure transducers on low power circuits. For higher bandwidth applications, the SDR Series meets the demands of today's highest speed communication systems. 120V and 240V AC versions are available for I/O and power supplies up to three Amps of load current and telephone networks can be protected by the SDPSTN. All modules are DIN-rail mountable on a TS-35 rail. A comprehensive range of mounting and grounding accessories are available. 172 The SLP device does not adversely affect the performance or operation of the loop or combined equipment during operation. The device allows signals to pass with very little attenuation, while diverting surge currents safely to the ground and clamping output voltages to safe levels. Fully automatic in operation, SLP devices react immediately to ensure that equipment is never exposed to damaging surges between lines or the lines and ground. Reacting instantly, the SLP redirects surges safely to the ground and resets automatically. The versatile SLP series provides full hybrid surge protection, combining protection for two process loops into one case. For higher bandwidth applications, the SLP series has been developed to meet the demands of today's highest speed communication systems. Surge Protection Devices--SD Series SD Series Guide to applications and selection The SD Series of signal protection devices includes models for a full range of applications operating at voltages up to 250V AC. The optional fuse/disconnect package provides both fused protection against fault currents and a convenient method of isolating field circuitry from protected circuitry without requiring additional disconnect terminals. The standard fuse (replaceable) is rated 250mA. 50mA fuses are available by special request. Solid links can be used in applications where only the disconnect feature is required. This feature is important in applications where a signal protection device is used with a bulk power supply feeding multiple loops. The individual fuse module prevents a fault or follow on current on one loop disrupting the power supply to the others. In addition, loops can be removed from the circuit for maintenance or added without requiring additional disconnect terminals. The following guide provides application information for the SD series. For technical information, see page 178. PROTECTED CIRCUIT FIELD CIRCUIT Analog inputs (high-level) Bulk PSU 2-wire transmitters, 4-20mA, conventional and smart SD32 and SD55 are recommended for use with conventional and smart 4-20mA transmitters (fed by a wellregulated supply), the choice dependent upon the maximum working voltage of the system (32V and 55V respectively). The diagram illustrates an application using the fuse/ disconnect. Both models are available in `X' versions without the optional fuse/disconnect feature. 1 Up to 50V dc 4/20mA 1 to 5V 2 4 TP48 transmitter protector 5 6 3 SD32 SD55 SD32X SD55X (no fuse) Multiple Loops 2-wire transmitters Analog inputs (low-level) SDRTD 1 4 RTDs, These applications are best served using the SDRTD. 5 For optimum accuracy, the energizing current should be chosen to ensure the voltage across the RTD does not exceed 1V over the full measurement range. When using a PT100 device, an energizing current of 1mA is recommended. Recorder Controller Computer etc. 2 6 3 SDRTD 3-wire RTDs Photocells and turbine flowmeters Depending upon the operational voltage, the SD07 or SD16 are the preferred choices for this application. SD07X and SD16X are also suitable. 2xSD07X or 2xSD16X 1 4 Photocell Thermocouple (THC) Signal 5 mV source 2 Turbine Flowmeter 6 3 SD07 SD16 photocells, thermocouples (THCs), mV sources and turbine flowmeters SD07X SD16X (no fuse) 173 Surge Protection Devices--SD Series PROTECTED CIRCUIT FIELD CIRCUIT 2xSD15X, SD32X Analog outputs 1 4 P V I Controller outputs (I/P converters) 5 Dependent on the operating voltage, recommendations include the SD16, SD32 and SD55, and the equivalent `X' versions. 2 6 OV 3 SD16 SD32 SD35 SD16 SD32X SD55X (no fuse) Controller outputs (I/P converters) SD Digital (on/off) inputs - Switches 1 4 Suitable signal protection devices include the SD07, SD16, SD32 and SD55 modules, and the equivalent "X" versions. The choice is dependent upon the operating voltage of the system. 5 V 2 6 Logic Signal 3 SD07 SD16 SD32 SD55 SD07X SD16X SD32X SD55X OV (no fuse) Switches SD32X Digital (on/off) outputs Alarms, LEDs, solenoid valves, etc. The SD32 or SD32X are the recommended choice for this application. 1 4 LED Alarm 5 32V max 2 6 3 SD32 SD32X (no fuse) Alarms, LEDs, solenoid values, etc. Telemetry Public Switch Telephone Network (PSTN) - Telemetry outstations 4 Incoming Telephone Line The SDPSTN has been designed specifically for the protection of signals transmitted on public switched telephone networks. 1 5 Modem, fax or telephone 2 6 3 Telecom line AC supplied equipment - PLC, I/O systems The recommended choice or systems on 110-120V AC is the SD150X ; for 220-240V AC systems, the SD275X is recommended. 5 6 PLC, I/O systems 174 4 110/120V ac or 220/240V ac Final output from 1 PLC, DCS, SCADA, etc. 2 3 Surge Protection Devices--SD Series Transmitter and sensor protection Transmitters and sensors are widely used in highly exposed areas and where lightning damage is common. In many cases, the ideal solution for 2-wire transmitters or sensors is the TP48, which mounts directly onto the transmitter via spare cable entries. Where these entries are not available or 3-wire devices are used, the compact design and simple installation of the SD Series makes it an ideal choice for transmitter protection. The SDs within the junction box should be installed as close as possible to the sensor or transmitter they are protecting, but no further than one meter away. A bond is required from the general mass of steelwork to the sensor or transmitter housing, using either a flat short braid or a cable at least 0.16 inch2 (4mm2) cross sectional area. In most instances, this bond is made automatically by fixing the metallic transmitter housing to the plant structure and ensures the voltage difference between the signal conductors and the transmitter housing is below the transmitter's insulation rating. Please note that the transmitters or sensors are connected to the SD protected equipment terminals, not the field cables. 2-wire transmitters or sensors 4-20mA transmitters - conventional and smart TO HOST CIRCUIT SD PROTECTED FIELD CIRCUIT The SD16X, SD32X and SD55X are an excellent alternative if the TP48 is not an acceptable solution, either because of technical suitability or mounting difficulties. 1 4 4-20mA 2 5 6 3 Plant structure SD16X SD32X SD55X SPD DIN rail 2-wire transmitter or sensor 3-wire transmitters or sensors Vibration Sensors and 4-20mA loop process control systems generally require three wire connections when powered from an external source. This may be accomplished in one unit by using the SD32T3 3- terminal Surge Protection Device (SPD). Because the SD32T3 protects all three conductors within the same unit, higher protection is achieved because the SPD hybrid circuitry is common to all three wires. The SD07R3 is also suitable for the protection of 3-wire pressure transducers on low power circuits. 4 1 2 Plant structure 24V 5 3 4-20mA 6 Common OV SD32T3 SPD DIN rail 3-wire transmitter or sensor 4-wire transmitters or sensors Flow meters, level detectors, etc. 4-wire systems such as level detectors require two SDs, one for the supply and the other for the transmitter output. Generally the voltages across the pairs are similar, so the recommended choice is a pair of SD16X, SD32X or SD55Xs. Dependent upon the supply voltage, AC powered transmitters should be protected with an SD150X for the supply inputs. 1 4 2 6 3 1 Plant structure 4-20mA 5 4 2 Supply voltage 5 Supply OV 6 3 SD16X SD32X SD55X SPD DIN rail 4-wire transmitter or sensor 175 Surge Protection Devices--SD Series Communication systems protection High-speed data links between buildings or one part of a plant to another have become more common with the widespread use of smart transmitters and the increase in remote installations. The SD Series has an SPD suitable for all process I/O applications with a choice of low resistance units, high bandwidth and a variety of voltage ranges. Featuring an extremely high bandwidth, the SDR Series is designed to meet the requirements for high speed data links. Communication systems RS232, RS422, RS485 SD PROTECTED HOST CIRCUIT TP PROTECTED FIELD CIRCUIT The recommended choice for these applications is the SD16R or SD32R depending on the maximum driver signal. 4 TP48 1 5 2 1 4 TP48 6 3 5 2 6 3 RS232, RS422, RS485 Bus powered systems There are a variety of bus powered systems specially designed for the process industry. The ideal surge protection device for these systems is the SD32R, with a very high bandwidth and modest in-line resistance. 4 1 PROTECTED FIELD CIRCUIT 4 5 2 46 1 3 2 SD32R (no fuse) 1SD PROTECTED HOST CIRCUIT 5 2 4 6 6 3 13 SD32R 5 (no fuse) 6 5 SD32R (no fuse) 2 3 SD32R (no fuse) TP48 4 1 5 TP48 6 4 5 SD32R (no fuse) 6 2 1 3 2 3 SD32R (no fuse) Bus powered systems Typical Applications Table 1 shows suitable SD devices for different applications. In some applications alternative devices may be used, for example, where lower in-line resistance or a higher voltage power supply is used. MTL Surge Technologies has operationally tested the recommended SD Series units with the representative highways listed. However, no formal approval for their use in these systems has been sought from the respective bodies. 176 Table 1 Application Allen Bradley Data Highway Plus Foundation Fieldbus 31.25kbits/s voltage mode 1.0/2.5 Mbits/s HART Honeywell DE LonWorks FFT-10 LPT-10 TP-78 IS78 Modbus & Modbus Plus (RS485) PROFIBUS DP PA (IEC 1158, 31.25 kbits/s) RS232 RS422 RS423 RS485 WorldRP (IEC 1158) 31.25 kbits/s voltage mode 1.0/2.5 Mbits/s Preferred Part No. SD16R SD32R SD55R SD32X SD32X Alternate Part No. SD32, SD32R SD32, SD32R SD32R SD55R SD07R SD32R SD16R SD32R SD32R SD16 SD07R SD07R SD07R SD32R SD55R SD16X Surge Protection Devices--SD Series Hazardous area applications Zone0/Zone1 The dangers from lightning induced sparking in Zone 0 are considered real enough to require preventative measures. IEC 60079-14 (1996-12) Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in hazardous areas (other than mines) stresses the importance of SPDs in hazardous areas. An outdoor installation where there is a high likelihood of both lightning induced transients and combustible gases requires the installation of SPDs to prevent possible ignition of the gases. Areas seen particularly at risk include flammable liquid storage tanks, effluent treatment plants, distillation columns in petrochemical works and gas pipelines. SPDs for transmitter protection should be installed in Zone 1, sufficiently close to the Zone 0 boundary to prevent high voltages entering Zone 0. The distance from the SPD to Zone 0 should be less than 36" where possible. In practice the SPD would normally be mounted on the transmitter or sensor housing which usually lies in Zone 1 and is very close to Zone 0. Because there is only a very small free volume, the SD series is suitable for mounting in flameproof or explosion proof enclosures. Zone 2 The SD series is suitable for protecting electrical circuits in Division 2, Zone 2 and can be used without affecting the safety aspects of the circuit. Non-incendive (low-current) circuits can be protected using any SD series unit mounted in either the safe or hazardous area, including those with the fuse disconnects facility. Non-arcing (high current) circuits can also be protected, however SPDs with the fuse disconnect facility may only be mounted in the safe area. For use in these circuits the units must be mounted in a suitable enclosure. In most cases the minimum requirements are IP54 and 7Nm resistance to impact. The SD series is self certified by MTL Surge Technologies as suitable for this purpose. Certification Introducing surge protection into Intrinsically Safe (IS) circuits is trouble free as long as the current and power parameters are not exceeded. In the SD series, the SD**X, SD**R, SD**R3, SDRTD and SD**T3 all have ATEX certification for use in IS circuits located in Zones 0, 1 or 2. The certification parameters for the SD**X and SD**T3 are: The certification parameters for the SD**R, SD**R3 and SDRTD are: EEx ia IIC T4, Li = 0 li = 260mA for Ui up to 60V The power rating for each of the above is dependent on the table shown below. Pi = 1W (-30C to +75C) Pi = 1.2W (-30C to +60C) Pi = 1.3W (-30C to +40C) The SD** series are classified as simple apparatus and are intended for use in Zone 2 or safe areas only, because their fuses are not fully encapsulated. Installation Positioning The SDs should be mounted on the field wiring side to ensure that any surges entering from the field do not damage any intrinsically safe barriers or galvanic isolators in the system. The SDs and intrinisically safe interface should be mounted close to each other but on separate DIN-rails in order to maintain the required 1.97" (50mm) clearance between safe area and hazardous area terminals of the IS interface. SD series DIN rail Instrument Instrument earth Substation ground mat Grounding The recommended grounding for field-mounted devices has been illustrated previously. The grounding at the control panel is more critical as there are usually a number of grounding systems, each with their own requirements.The grounding system illustrated here replaces the instrument 0V bond, the control system PSU bond and the IS ground with one single ground connection to meet all the design requirements and give the most effective protection against the effects of lightning induced surges. Marshalling cabinet EEx ia IIC T4, Li = 0.22mH li = 260mA for Ui up to 20V li = 175mA for Ui up to 26V li = 140mA for Ui up to 28V li = 65mA for Ui up to 60V IS barrier DIN rail Field cables System Connection Cable SPD Isolated instrument rail Isolated instrument rail Electrical earth Frame connection Floor void System earth To plant/neutral star point In all installations utilizing safety related apparatus, consideration should be given to protecting the system supply and any long communication cable. 177 Surge Protection Devices--SD Series Protection Full hybrid line to line Each line to screen/ground Max. discharge surge current (Imax) (8/20s) 20kA (8/20s) 6.5kA (SD150X and SD275X only) Nominal discharge surge current (isn) 3kA (8/20s) Lightning impulse current (Iimp) (10/350s) 2.8kA 1.0kA (SD150X and SD275X only) Response time <1ns RTD resistance range (SDRTD) 10 to 1500 Degradation accuracy (SDRTD at 1mA) 0.1% (RTD resistance > 100) 0.1W (RTD resistance < 100) Ambient temperature -40C to +80C/ -40F to 176F working -40C to +80C / -40F to 176F storage For IS working applications: Pi = 1.0W (-30C to +75C / -22F to 167F) Pi = 1.2W (-30C to +60C / -22F to 140F) Pi = 1.3W (-30C to +40C / -22F to 104F) Humidity 5 to 95% RH (non-condensing) Category tested A2, B2, C1, C2, C3 Overstressed fault mode In=3kA 12kA 9kA (SD150X and SD275X only) Impulse durability (8/20s) 10kA 6.5kA (SD150X and SD275X only) Terminals 2.5mm2 (12 AWG) Mounting T-section DIN-rail 35 x 7.5 or 35 x 15mm rail (1.38" x 0.3" x 0.6") Weight 70g approximately (2.5oz) Case flammability UL94 V-2 AC durability 1Arms, 5T Service conditions 80kPa - 160kPa 5% - 95% RH EMC compliance To Generic Immunity Standards, EN 61326-1, part 2 for industrial environments R&TTE compliance EN 41003:1999 EN 60950-1:2006 (not applicable to SD150X and SD275X) LVD compliance SD150X & SD275X EN 60950-1:2006 EN 61010:2010 SDPSTN EN 41003:1999 IEC compliance EN 61643-21:2001 ANSI/IEEE testing C62.41-1-2002 C62.41-2-2002 C62.45-2002 178 Approvals (Authority) Standard Certificate/File No. Approved for Product Country Baseefa [ATEX] EN 60079-0:2009 Baseefa02ATEX0211X Ex ia IIC T4 Ga SD07X, SD16X, SD32X, SD55X, SD07R, (EU) EN 60079-11:2007 Ta = -30C to SeeSD16R, SD32R, SD55R, SDRTD, SD32T3, ScheduleSD07R3, SD16R3, SD32R3, SD55R3 MTL EN 60079-15:2005 MTL03ATEX0755X Ex nA IIC T4 SD07, SD16, SD32, SD55, SD07X, (EU) EN 60079-14:2003 SD16X, SD32X, SD55X, SD07R, SD16R, SD32R, SD55R, SD32T3, SD07R3, SD16R3, SD32R3, SD55R3, SDRTD Baseefa [IECEx] IEC 60079-0: 2007-10 IECEx BAS 12.0003X Ex ia IIC T4 Ga SD07X, SD16X, SD32X, SD55X, SD07R, (International) IEC 60079-11: 2006 SD16R, SD32R, SD55R, SDRTD, SD32T3, SD07R3, SD16R3, SD32R3, SD55R3 CSA/C/US CSA C22.2 No. 0-M1991 LR 36637 EEx ia Class 1,SD07, SD16, SD32, SD55, SD07X, (Canada, USA) CSA C22.2 No. 157-M1992 Groups A, BSD55X, SD07R, SD16R, SD32R, SD55R, UL 913, 5th edition C and D, T4SDRTD, SD32T3, SD07R3, SD16R3, CSA C22.2 No. 142-M1987 Class 1, Div 2 SD32R3, SD55R3 CSA C22.2 No. 213-M1987 Groups A,B,C, D T4 UL UL 497B Listed E220693 Isolated loop SD07, SD16, SD32, SD55, SD07X, (USA) communication SD16X, SD32X, SD55X, SD07R, SD16R, circuitsSD32R, SD55R, SD07R3, SD16R3, SD32R3, SD55R3, SD32T3, SD55T3, SD07X3, SD16X3, SD32X3, SD55X3, SDRTD Austel AS/NZ3548:1995 __ Private Wire SD07R (Australia) AS/NZS4117:1996 TS001: 1997 0.28" +0.02" -0.0" +0.4mm -0.0mm 7.0mm 1 4 2 5 6 3 4.03" (102.1mm) 0.28" rail (7mm) 4.32" (109.6mm) 0.6" rail (16mm) All figures typical at 77F (25C) unless otherwise stated 3.99" (101.3mm) Specifications SD Series 3.9" (99mm) Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance /line Max. leakage current A Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/s V Residual voltage @ isn V Bandwidth frequency fG Special feature Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance /line Max. leakage current A Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/s V Residual voltage @ isn V Bandwidth frequency fG Special feature SD07 SD16 SD32 SD55 7 5 250 4.2 500 7.7 <12 16 11 250 4.2 5 17 <25 32 22 250 4.2 5 36 <45 55 38 250 4.2 5 62 <90 30 25 kHz Fuse disconnect 40 25 kHz Fuse disconnect 60 25 kHz Fuse disconnect 100 25 kHz Fuse disconnect SD07R SD16R SD32R SD55R 7 5 400 2.7 500 7.7 <12 16 11 400 4.7 5 17 <25 32 22 400 10 5 36 <45 55 38 400 10 5 62 <90 30 50 MHz High bandwidth 40 50 MHz High bandwidth 60 50 MHz High bandwidth 100 50 MHz High bandwidth Surge Protection Devices--SD Series Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance /line Max. leakage current A Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/s V Residual voltage @ isn V Bandwidth frequency fG Special feature Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance /line Max. leakage current A Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/s V Residual voltage @ isn V Bandwidth frequency fG Special feature Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance /line Max. leakage current A Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/s V Residual voltage @ isn V Bandwidth frequency fG Special feature SD07X SD16X D32X SD55X 7 5 400 2.2 500 7.7 <12 16 11 400 2.2 5 17 <25 32 22 400 2.2 5 36 <45 55 38 400 2.2 5 62 <90 30 25 kHz Low resistance 40 25 kHz Low resistance 60 25 kHz Low resistance 100 25 kHz Low resistance SD32T3 SD07R3 SD16R3 SD32R3 SD55R3 32 22 400 2.2 5 36 <45 7 5 400 2.7 500 7.7 <12 16 11 400 4.7 5 17 <25 32 22 400 10 5 36 <45 55 38 400 10 5 62 <90 75 720 kHz 3 terminal 30 50 MHz 3 terminal 40 50 MHz 3 terminal 60 50 MHz 3 terminal 100 50 MHz 3 terminal SDRTD SDPSTN SD150X SD275X 1 0.75 10 2.7 0.3 5 <12 162 114 550 4.7 5 175 <200 150 120 3A 0.1 50 ac rms; 170 ac 130 ac rms <400 320 240 3A 0.1 50 ac rms; 360 ac 275 ac rms <700 30 50 MHz 3-wire RTD 235 4 MHz PSNT 450 -High current 850 -High current Ordering Data Description Mounting Accessories Grounding/Ground Rail Accessories Accessories (Replacement) Type Rail Holder Ground terminal, DIN-rail mounted Replacement fuse pack 250mA standard Part No. 0494920000 1010100000 SDF25 XXXXXXXXXX - 2013 179 Surge Protection Devices--SLP Series Specifications SLP Series All figures typical at 77F (25C) unless otherwise stated Maximum surge current 20kA (8/20s waveform) per line Leakage Current <1A @ working voltage Maximum rated load current 1.50A Loop resistance 2 Ohm Capacitance Line to Line - 60pF Bandwidth -0.1db @9kHz - 37MHz -3dB @50MHz Response time <1ns Ambient temperature -40C to +70C (working) -40F to +158F (working) -40C to +80C (storage) -40F to +176F (storage) Humidity 5 to 95% RH (non-condensing) Terminals 2.5mm2 (12 AWG) Electrical connections Plug/header screw terminal strip Mounting T-section DIN-rail (35 x 15mm rail) Weight 5oz (140g approximately) Case flammability UL94-V0 EMC compliance BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 BS EN 61000-4-5:2006 Dimensions Approvals Country (Authority) Europe (Baseefa) Europe (MTL) USA (FM) Canada (FM) Technical Data Nominal voltage Un Rated voltage (MCOV) Uc Nominal current In Nominal discharge current (8/20s) isn Max discharge current (8/20s) Imax Lightning impulse current (10/350s) Iimp Residual voltage (@ isn) Up Voltage protection level (@ 1kV/s) Up Bandwidth fG Capitance C Series resistance R Operating Temperature Range Category tested Overstressed fault mode in-3kA Impulse durability (8/20s) Degree of protection AC durability Service conditions Connections Installation 180 XXXXXXXXXX - 2013 Standard Certificate/File No. Approved for EN 50014:1997 + A1 & A2 Baseefa04ATEX0303X EEx ia IIC T4 EN 50020:2002 EN 60079-26:2004 BS EN 50014:1998 MTL03ATEX0377X EEx n IIC T4 BS EN 50021:1999 EN 60079-15:2003 Class Nos. 3600 (1998), 3011208 IS/I/1/A-D 3610 (2010), 3611 (1999), I/0/AEx ia IIC 3615 (1989), 3810 incl. I/0/AEx ia IIB Supp 1 (1995-07 (1989-03), NI/I/2/A-D ANSI/NEMA 250 (1991) NI/I/2/IIC ANSI/ISA 60079-0 (2009 ANSI/ISA 60079-11 (2009) ISA-S12.0.01 (1999) C22.2 No. 213, 142, 94, 3025374C IS/I/1/A-D 157, 30 I/0/AEx ia IIC ANSI/NEMA 250 I/0/AEx ia IIB CAN/CSA-E79-0 NI/I/2/A-D CAN/CSA-E79-11 NI/I/2/IIC Product SLP07D, SLP16D, SLP32D SLP07D, SLP16D, SLP32D SLP07D, SLP16D, SLP32D SLP07D, SLP16D, SLP32D SLP07D SLP16D SLP32D 7V 8V 1.50A 3kA 20kA 2.5kA 10V <8V 50MHz 60pF 1.0 -40C to +80C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH 16V 18V 1.50A 3kA 20kA 2.5kA 23V <18V 50MHz 60pF 1.0 -40C to +80C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH 24V 32V 1.50A 3kA 20kA 2.5kA 40V <38V 50MHz 60pF 1.0 -40C to +80C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH Surge Protection Devices--MA15 Series Dimensions Specifications MA15 Series All figures typical at 77F (25C) unless otherwise stated MA15 Series Industrial control systems utilizing programmable logic controllers (plc) and industrial computers are particularly vulnerable due to the aggressive electrical environments for which they are intended, such as process plants, factories and water treatment sites. Although industrial computers and PLCs are designed to be rugged, the extra protection provided by the DIN-rail mounting MA15 units is critical. Ideally suited for protecting panel mounted equipment and typically used in the controls section of a motor control center (MCC), the MA15 range provides surge and RFI protected power. With a unique `three-stage' combination of protection elements, these units suppress conducted RFI and voltage surges. The circuit elements are: (1) surge clipping components to absorb transient surges that may otherwise damage equipment, (2) a filter to suppress noise in the system and, (3) ring suppression. Ring suppression prevents surges causing the filter to `ring' (oscillate) under low load conditions - an effect that actually accentuates interference in most commercially available filters. Suitable for AC or DC application, MA15 units reduce both electromagnetic emissions and the susceptibility of the associated equipment to emissions from other sources. MA15 devices also offer installation flexibility. To protect circuits rated 15A or less, MA15 devices should be installed in series. To protect higher current circuits, simply install the MA15 in parallel. LED status indication is standard with the MA15 units. Thermal fusing is also incorporated into each 18kA rated device as an additional safety feature. MA15 modules also offer short circuit protection for added safety. MA15 devices are UL 1449 Recognized Components (certified by UL for both US and Canadian requirements) and exceed the requirements of IEC 61000-4-5. As MA15 units suppress conducted RFI and voltage surges they enable associated equipment to comply with this aspect of European `CE' mark standards. Maximum surge current: 18kA (8/20s) per mode Leakage current <0.3mA Maximum continuous operating current 120V @ 15A, 240V @ 10A series connection Unlimited Amps in parallel Working voltage AC DC MA15/D/1/SI 120V, 47-63Hz 140V MA15/D/1TT/SI 120V, 47-63Hz 140V MA15/D/2/SI2 40V, 47-63Hz 280V MA15/D/2TT/L 240V, 47-63Hz 280V Maximum continuous operating voltage 25% above nominal Limiting voltage Let through voltage @ 500A ring 120V/140V versions 295V 240V/280V versions 356V @ 500A 8/20s 120V/140V versions 320V 240V/280V versions 800V @ 3kA 8/20s 120V/140V versions 396V 240V/280V versions 975V @ 10kA 8/20s 120V/140V versions 585V 240V/280V versions 1210V Maximum attenuation (typical): -55dB @ 100MHz Modes protected: L-N, L-E, N-E Ambient temperature limits -40F to +185F (working) -40C to +85C (working) Humidity 95% RH (non-condensing) Casing Polymide-PA, with G- or T-section (Top-hat) DIN-rail mounting foot UL94-V0 Connectors Screw terminal Terminals 0.1 inch2 (2.5mm2 ) 12 AWG Mounting G- or T-section (`Top-hat') or 1.4 inch (35mm) DIN-rail Weight 3.53oz (100g) EMC compliance BS EN 60950 : 1992 BS EN 61000-6-2 : 1999 LED Indication Green LED on Protection present Green LED off Internal failure Installation The grounding of the surge protector and the protected equipment is very important and, if possible, should be accomplished as illustrated. Please note that the unit is marked Line and Load and it is important that the unit is installed with the Line side connected to the incoming power and the Load connected to the equipment to be protected. For parallel application however, the Line side is connected to the incoming power and the Load left unconnected. Ordering Data AC 120V, 47-63Hz 240V, 47-63Hz DC 140V 280V Part No. MA15D1SI MA15D2SI Approvals Country (Authority) United States Canada United States Canada Standard UL 1449 Recognized Component UL 1449 Recognized Component UL 1604 Approved for AC Power Product Hazardous Locations Class I, Division 2 Groups A, B, C and D Product No. MA15D1SI, MA15D2SI MA15D1SI, MA15D2SI { 181 Surge Protection Devices--TP48 Series The TP Series protection network consists of high-power, solid-state electronics and a gas-filled discharge tube capable of diverting 20kA impulses. The whole unit is encased in an ANSI 316 stainless steel housing, threaded for the common conduit entries used on process transmitters. Versions are available for 1/2" NPT, 20mm ISO, and G1/2" (BSP 1/2 inch) threaded entries. Approvals Country (Authority) EC (BASEEFA) Specifications TP Series All figures typical at 77F (25C) unless otherwise stated Maximum surge current 20kA peak current (8/20s waveform) Leakage current Less than 10A at maximum working voltage Working voltage 35 VDC maximum Bandwidth 1MHz Resistance No resistance introduced into loop Ambient temperature limits -40C to +80C (working) -40F to +185F (working) -40C to +85C (storage) -40F to +185F (storage) Humidity 5% to 95% RH (non-condensing) Electrical connections TP48 3 flying leads (line1, line 2 & ground) TP48 3 Wire 4 flying leads (+ve, -ve, signal & ground) TP48 4 Wire 5 flying leads (+ve, -ve, signal +ve, signal -ve, ground) Wire size 32/0.2 (1.0mm2, 18 AWG) Lead length 250mm (minimum) Casing ANSI 316 stainless steel hexagonal barstock, male thread Threads TP48-3-N & TP48-4-N 1/2" NPT TP48-3-I & TP48-4-1 20mm ISO (M20 x 1.5) TP48-3-G & TP48-4-G G 1/2" (BSP 1/2") Weight 175g (6.2oz) Dimensions See Figure 1 EMC compliance To Generic Immunity Standards EN50082, part 2 for industrial environments Electrical safety EEx ia IIC T4, Ceq=O, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <60V and input power <1.2W. EEx d IIC T4; the unit is apparatus-approved to flame proof (explosionproof) standards, and can be fitted into a similarly approved housing. Standard Certificate/File No. EN 50014:1997 + BASEEFA04ATEX0251X Amendments 1 & 2 EN 50020:1994, EN 50284:1999 EC (BASEEFA) EN 50014:1997 + BASEEFA04ATEX0251X Amendments 1 & 2 EN 50018:2000 + Amendment 1 Atex Directive BS EN 50021:1999 TML02ATEX0032X 94/9/EC USA (FM) Class Nos. 3600 3022293 (1998), 3610 (1999), 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07) (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) Canada (FM) C22.2 No. 157 3025374 C22.2 No. 213 C22.2 No 142 C22.2 No. 94 C22.2 No. 30 Global IEC 60079-0:2004 IECEx BAS 07.0045X IEC 60079-11:2006 IEC 61241-0:2004 IEC 61241-1:2004 Technical Data Nominal voltage Un Rated voltage (MCOV) Uc Nominal current In Nominal discharge current (8/20s) isn Max discharge current (8/20s) Imax Lightning impulse current (10/350s) Iimp Residual voltage @ isn Up Voltage protection level @ 1kV/s Up Bandwidth fG Capacitance C Series resistance R Operating Temperature Range Category tested Overstressed fault mode in=3kA Impulse durability (8/20s) Degree of protection AC durability Service conditions Figure 1 2.95" (75mm) 1.07" (27mm) Dimensions across flats 0.91" (23mm) 182 2.17" (55mm) Intrinsically Safe: I, II, II/1/A-G, I/O/IIC Explosionproof: I/1/A-D Nonincendive: I/2/A-D, I/2/IIC Dust ignition proof: II, III/1/EFG Special protection: II/2/FG Ex ia IIC T4/T5/T6 Ex tD A20 IP6X T85C/T100C/ T135C TP48-X-Y-Z TP48-X-Y-NDI Key: X = 3 or 4 or blank, Y = N, I or G, Z = NDI Dimensions 0.91" (23mm) Approved for Product EEx ia IIC T6 (Tamb = -40 to 60C) TP48-X-Y-Z EEx ia IIC T5 (Tamb = -40 to 85C) EEx ia IIC T4 (Tamb = -40 to 60C) EEx d IIC T6 (Tamb = -40 to 60C) TP48-X-Y-Z EEx d IIC T5 (Tamb = -40 to 80C) EEx d IIC T4 (Tamb = -40 to 85C) Ex n II T6 (-40C