Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A n! Al nglig - Alltid o pp tillga e tl id en Alw ! www.chscontrols.se ay op s av ailable - Always Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A A New Generation of Moulded Case Circuit Breakers Eaton's Cutler-Hammer offer a complete range of Moulded Case Circuit Breakers - MCCBs - 15 - 630 A in three frame sizes. Each frame size offers a choice of several breaking capacities up to 100 kA at 400 VAC. The MCCB:s are designed to conform with all major international standards including IEC 60947-2 and UL 489/CSA C22.2 No 5.1. The performance is third party certified by KEMA, UL and CSA. KEMA, UL and CSA are independent third party test houses which assure that Eaton's Cutler-Hammer MCCB:s meet their exacting standards through regularly scheduled follow-up testing and inspection. Innovative design and an optimum of performance The flexibility and outstanding performance characteristics of Eaton's Cutler-Hammer MCCBs are made possible by the most logically designed contact assemblies. Based on the patented contact design, the contact assembly creates a high speed "blow-open" action when it confronts the electromechanical forces produced by a high-level fault current. Breaking Capacity, Icu at 400 VAC, kA 100 80 C C 60 Cascading and discrimination The current limiting capacity reduces the rated breaking capacity required for the other circuit breakers installed downstream. With Eaton's Cutler-Hammer MCCBs, a high level of discrimination in a distribution system is achieved. When a fault occurs, only the MCCB located immediately upstream is tripped. Protect IEC/NEC, the new discrimination software, includes the complete range of protective devices from Eaton's Cutler-Hammer. Protect IEC/NEC is easy to use and drastically reduces the time spent on discrimination studies. Additional information as cascading rating sheets as well as time/ current curves can be downloaded from our web site, www.chscontrols.se. H H 40 The MCCBs carry both UL, CSA and KEMA-KEUR certification as standard. H S 20 S E Same MCCBs for IEC and North American applications S Eaton's Cutler-Hammer Series G MCCBs are for truly global use with UL/CSA/KEMA-KEUR approvals as standard. Series G MCCBs are UL 489 listed and meet the requirements in National Electrical Code (NEC) for "Branch Circuit Protection", "Motor Branch Circuit Protection" and as "Disconnecting Means". Operating mechanism meets the requirements for mechanical interlocking according to NFPA 79. B E E 0 EG fr ame JG fra me LG fra me Three frame sizes cover 15 - 630 A, breaking capacity from 18 - 100 kA at 400 VAC Unmatched protection and flexibility All Eaton's Cutler-Hammer MCCBs are current limiting. High speed opening and the electromagnetic repulsion forces in combination with the incorporation of sophisticated arc extinguishing technique limit energy developed by the short-circuit current to very low values. A wide selection of trip units for different applications are available, thermal-magnetic and Digitrip electronic types, with or without earth fault protection. Digitrip trip units detect earth fault currents through residual sensing, they are not designed for zero sequence. Earth leakage modules, based on zero sequence sensing, with a built-in current sensor are also available. This technique allows for protective sensitivities down to 30 mA levels. Earth leakage MCCBs are available up to 630 A and according to IEC and UL standard. 2 Information regarding Series G MCCBs 800 - 2500 A are availabe in a separate cataloge! www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A A Complete System for Unmatched Flexibility... 12 11 10 8 9 I 0 N 21 0 F F 20 7 6 5 T E S T 1 T E S T 4 3 2 WARNING reset test 13 16 15 18 17 16 14 19 ON 25 OFF/O OFF OFF/O I ON Trip ON/I Trip OFF O ON/I 24 23 22 1 2 3 4 5 Circuit breaker Thermal magnetic trip unit, integrated on EG frame Magnetic only trip unit, integrated on EG frame Electronic protection trip unit, JG/LG frame only Auxiliary/alarm contact 11 12 13 14 15 Terminal end cover Interphase barrier Control wire kit Multiwire connector Steel cable terminal 6 7 8 9 10 Shunt trip Undervoltage release DIN-rail mounting adaptor, EG frame only Plug-in block Terminal cover 16 17 18 19 20 Aluminium/copper terminal Terminal spreader Endcap kit Earth leakage module, side mounted on EG frame Padlockable handle lock hasp www.chscontrols.se 21 22 23 24 25 Padlockable handle block Motor operator Direct close coupled handle mechanism Through-the-door handle mechanism Flexshaft handle mechanism 3 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Program Overview see note 1, 2, 3, 4, 5, 6 Breaking capacity, IEC 60947-2 230 VAC Icu Ics 400 VAC Icu Ics 690 VAC 250 VDC Icu Ics Icu Ics Breaking capacity, UL 489 240 VAC 480 VAC 600Y/347 VAC 600 VAC General Rated voltage Ue IEC 60947-2, V Rated voltage UL 489, V Current range In, A Utilization category, IEC 60947-2 Trip units Type Thermal magnetic Magnetic only, starter combination Electronic EG frame B E S H JG frame E S H C LG frame E S H C 25 25 18 18 35 35 25 25 85 43 40 30 100 50 70 35 65 65 25 25 85 85 40 40 100 100 70 70 200 150 100 75 65 65 35 35 85 85 50 50 100 100 70 70 200 150 100 75 10 10 3 3 10 10 4 3 35 35 6 3 42 42 12 6 10 10 12 6 35 35 14 7 42 42 20 10 42 42 12 6 22 22 20 10 22 22 25 13 42 42 35 18 42 42 35 25 18 85 35 22 100 65 25 65 25 85 35 100 65 200 100 65 35 85 50 100 65 200 100 18 25 35 50 18 25 35 50 25 18 500, 690 480, 600Y/347 15 - 125/160 A 690 600 20 - 250 A 690 600 100 - 600/630 A Fixed trip units FT-FM, AT-FM AM Interchangeable trip units FT-AM, AT-AM AM LS, LSI, LSG, LSIG Interchangeable trip units FT-AM, AT-AM AM LS, LSI, LSG, LSIG Notes 1 125 A is max UL rating for EG frame. 600 A is max UL rating for LG frame. 2 DC ratings are based on two poles in series. 3 MCCBs with "Straight voltage rating" have been tested for use in a circuit where the nominal voltage between any two conductors does not exceed the voltage rating of the MCCB. The slash (/) between the higher and lower voltage ratings indicates that the MCCB has been tested for use in a circuit with higher voltage between phases and with the lower voltage to ground. EG-frame MCCBs have been tested for 600Y/347 and 480 V Straight per UL 489. Contact CHS Controls for application assistance. 4 See page 20 for breaking capacity for starter combination breakers. 5 Available protection types. Curves are available at www.chscontrols.se. FT-FM Fixed thermal, fixed magnetic LS Long delay and short delay protection AT-FM Adjustable thermal, fixed magnetic LSI Long delay, short delay and instantaneous protection FM-AM Fixed thermal, adjustable magnetic LSG Long delay, short delay and earth fault protection AT-AM Adjustable thermal, adjustable magnetic LSIG Long delay, short delay, instantaneous and earth fault protection AM Adjustable magnetic, starter combination 6 Electronic trip units are not suitable for DC applications. 4 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Technical Data Moulded Case Circuit Breakers Frame size EG JG LG General Current range, In IEC 60947-2, A Current range, In UL 489, A Utilization category, IEC 60947-2 Number of poles 16-160 15-125 A 1, 2, 3, 4 20-250 20-250 A 2, 3, 4 70-630 70-600 A 3, 4 Rated operational voltage, Ue, IEC 60947-2, V Rated operational voltage, Ue, UL 489, V Rated insulation voltage, Un, IEC 60947-2, V Rated impulse withstand voltage, Uimp, IEC 60947-2, kV 500, 690 480, 600Y/347 690 6 690 600 750 8 690 600 750 8 Breaking Capacity IEC 60947-2 UL 489 See product overview on page 4 and product selection See product overview on page 4 and product selection Moulded Case Switch (MCS) Breaking capacity at 415 VAC, unfused, kA Breaking capacity at 480 VAC, unfused, kA Self protected, will trip above, A 70 65 1250/1600 70 65 2500 70 65 4000/6300 Environmental Permissible ambient temperature, C Power losses, plant protection/isolating/starter combination, W -20 - +70 50/40/40 -20 - +70 75/75/45 -20 - +70 255/160/160 Operation, Endurance Main switch characteristic, IEC 60947-2 Suitable for reverse feed see note 7 Opening time, ms Maximum switching frequency, operation/hour Yes, in combination with locable rotary device Yes Yes Yes <50 <50 <50 300 240 240 Endurance, operating cycles 10000 10000 80000 Permissible Loads for Various Ambient Temperatures MCCBs for plant protection see note 8 At 40C At 50C At 55C At 60C At 70C 100/100% 96/92% 93/87% 91/83% 86/73% 100/100% 96/94% 94/90% 92/87% 88/80% 100/100% 96/91% 93/86% 90/82% 84/70% 100% 100% 96% 91% 86% 100% 100% 96% 92% 88% 100% 100% 95% 90% 84% MCCBs for starter combinations/MCS At 40C At 50C At 55C At 60C At 70C 90 90 Approvals KEMA-KEUR MCCBs for plant protection only UL 489/508/1076 CSA C22.2 90 Weights 3 pole, kg 4 pole, kg 90 Permissible Mounting Positions 1,4 1,8 5,2 7 7,3 9,1 Certificate No 2012668.09 2012668.12 Pending, available in June 2005 File File E7819 LR43556 E7819 LR43556 E7819 LR43556 Notes 7 EG frame MCCB for starter combinations (HMCPE) can not be used for reverse feed 8 First figure: thermal trip set to the lower value, second figure: thermal trip set to the upper value. www.chscontrols.se 5 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Technical Data - Electronic Trip Units see note 6, 9 LS protection LSG protection LSI protection LSIG protection Sensing method Overtemperature protection RMS Yes RMS Yes RMS Yes RMS Yes Overload protection, long time delay (L) Long delay setting, Ir Long delay time I2t at 6 x Ir Long delay thermal memory 0,5-1 x In 2-24 s Yes 0,5-1 x In 2-24 s Yes 0,5-1 x In 2-24 s Yes 0,5-1 x In 2-24 s Yes Short circuit protection, short time delay (S) Short delay setting Short delay time I2t Short delay time flat 200-800% x In 100 ms No 200-800% x In 100 ms No 200-800% x In No I-300 ms 200-800% x In No I-300 ms Short circuit protection, instantaneous (I) Instantaneous setting see note 10 Instantaneous override No Yes No Yes 200-800% x In Yes 200-800% x In Yes Eath fault protection (G) Earth fault protection Earth fault delay, flat No No Yes I, 120 ms No No Yes I, 120 ms Field testing External test set External test set External test set External test set DC Applications The MCCBs with thermal magnetic trip units are suitable for switching DC currents. MCCBs with electronic trip units should not be used. conducting paths are required, see proposed circuits for 3 and 4 pole MCCBs below. For switching DC currents, however the maximum permissible voltage per conducting path has to be considered. As the current has to flow through all conducting paths so as to maintain the thermal tripping characteristics, the following circuit arrangements are recommended. With DC, the trip values of the instantaneous short circuit release is increased by 30 - 40%. For voltages higher than 250 VDC, the series connection of two or three Double-pole switching max 250 VDC M If there is no risk of an earth fault, or if any earth fault which occurs is immediately eliminated (earth fault monitoring), the max permissible voltage can be 600 VDC. Double-pole switching - earth system, max 440 VDC Single-pole switching - earth system, max 600 VDC M M The earthed pole must always be assigned to the individual conducting path, so that two paths are always in series in case of an earth fault. Three conducting paths in series. The earthed pole must be assigned to the nonswitched conducting path. Notes 6 Electronic trip units are not suitable for DC applications. 9 Curves are available at www.chscontrols.se. 10 JG frame has also a 1400% setting. 6 www.chscontrols.se Single-pole switching - earth system, max 750 VDC M Four conducting paths in series. The earthed pole must be assigned to the nonswitched conducting path. Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Internal Accessories Series G MCCBs can be equipped with a number of internal accessories, auxiliary switches, alarm switches, shunt trip and undervoltage release. Technical Data - Auxiliary/Alarm Switches Auxiliary switches Available with one or two changeover contacts. They indicate if the MCCB is in closed or open position. General Rated thermal current, Ith, A Rated making capacity, A Rated insulating voltage Un, V Rated impulse withstand voltage Uimp, kV Alarm switches Available with one or two changeover contacts. They indicate if the MCCB is in tripped position. MCCB Toggle position Auxiliary switch position Alarm switch position 6 20 690 4 Electrical Data, Utilization Category AC-15, IEC 60947-5-1 Rated operational voltage, VAC 230/400/600 Rated operational current, A 6/3/0,25 Back up fuse class gG 6/4/4 Miniature circuit breaker, B-curve 6/4/Electrical Data, Utilization Category DC-13, IEC 60947-5-1 Rated operational voltage, VDC 125/250 Rated operational current, A 0,5/0,25 Back up fuse class gG 6/4 Miniature circuit breaker, B-curve 6/4 Off/Reset On Technical Data - Shunt Trip/Undervoltage Trip Tripped Contact position by the auxiliary and alarm switches as a function of the switching position of the MCCB Combination switches Consist of one changeover alarm switch and one changeover auxiliary contact. Shunt trip Shunt trip is used for remote tripping of the MCCB. The shunt trip coil is only rated for short time operation and should not be used in control circuits with a continuous command. The shunt trip has built-in cut-off switch to prevent coil burnout. Undervoltage release The MCCB can not be closed until the undervoltage release is energized. If the undervoltage release is not energized, the MCCB can only perform an idle switching operation. Idle operation should be avoided as they shorten the endurance of the MCCB. 3 pole MCCB Left Shunt Trip Response voltage, pick-up, Us Opening time 70 - 110% <50 ms Power consumption short time operation 120 VAC 240 VAC 380-600 VAC 24 VDC <435 VA <435 VA <1050 VA <635 W 48 VDC <1580 W Undervoltage Release Response voltage, drop Us Response voltage, pick-up, Us Opening time 35-70% 85-110% <50 ms Power consumption, continuous operation 24 VAC 48 VAC 120 VAC 208 - 240 VAC 380 - 500 VAC 525 - 600 VAC <4 VA <4 VA <2,5 VA <4 VA <6 VA <4,5 VA 4 pole MCCB Right Left Right U< 1/2 AUX U< 1/2 AUX U< 1/2 AS U< 1/2 AS U< 1 AS + 1 AUX U< U< Shunt trip/undervoltage release AUX = Auxiliary switch 24 VDC 48 VDC 120 VDC 220-250 VDC <3,1 W <3,1 W <2,2 W <4 W 1 AS + 1 AUX AS = Alarm switch Accessory alternatives - one of above combinations, insulated accessory chambers www.chscontrols.se 7 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Moulded Case Circuit Breakers for Plant Protection, EG Frame 15 - 160 A, IEC/UL/CSA Breaker Capacity see note 3, 11 Breaker Rated voltage, Ue, VAC type IEC UL/CSA Breaking capacity, kA IEC 60947-2, Icu/Ics, VAC 230 400 690 UL 489/CSA, VAC 240 480 600Y/347 B E S H 25/25 35/35 85/43 100/50 25 35 85 100 18 22 25 500 500, 690 500, 690 500, 690 480 600Y/347 600Y/347 600Y/347 18/18 25/25 40/30 70/35 3/3 4/3 6/3 Catalogue Numbers, 3 Pole MCCB with Thermal-Magnetic Trip Unit see note 12, 13, 14, 15, 16, 17 Rated current In, A Adjustable range Thermal Magnetic Ir, A Im, A Catalogue numbers, complete breakers Type B Type E Type S Type H 15 16 20 25 30 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB3015FFG EGB3016FFG EGB3020FFG EGB3025FFG EGB3030FFG EGE3015FFG EGE3016FFG EGE3020FFG EGE3025FFG EGE3030FFG EGS3015FFG EGS3016FFG EGS3020FFG EGS3025FFG EGS3030FFG EGH3015FFG EGH3016FFG EGH3020FFG EGH3025FFG EGH3030FFG 32 35 40 45 50 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB3032FFG EGB3035FFG EGB3040FFG EGB3045FFG EGB3050FFG EGE3032FFG EGE3035FFG EGE3040FFG EGE3045FFG EGE3050FFG EGS3032FFG EGS3035FFG EGS3040FFG EGS3045FFG EGS3050FFG EGH3032FFG EGH3035FFG EGH3040FFG EGH3045FFG EGH3050FFG 60 63 70 80 90 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB3060FFG EGB3063FFG EGB3070FFG EGB3080FFG EGB3090FFG EGE3060FFG EGE3063FFG EGE3070FFG EGE3080FFG EGE3090FFG EGS3060FFG EGS3063FFG EGS3070FFG EGS3080FFG EGS3090FFG EGH3060FFG EGH3063FFG EGH3070FFG EGH3080FFG EGH3090FFG 100 125 160 20 25 Fixed Fixed Fixed 16-20 20-25 Fixed Fixed Fixed Fixed Fixed EGB3100FFG EGB3125FFG EGB3160FFG EGB3020AFG EGB3025AFG EGE3100FFG EGE3125FFG EGE3160FFG EGE3020AFG EGE3025AFG EGS3100FFG EGS3125FFG EGS3160FFG EGS3020AFG EGS3025AFG EGH3100FFG EGH3125FFG EGH3160FFG EGH3020AFG EGH3025AFG 32 40 50 63 80 25-32 32-40 40-50 50-63 63-80 Fixed Fixed Fixed Fixed Fixed EGB3032AFG EGB3040AFG EGB3050AFG EGB3063AFG EGB3080AFG EGE3032AFG EGE3040AFG EGE3050AFG EGE3063AFG EGE3080AFG EGS3032AFG EGS3040AFG EGS3050AFG EGS3063AFG EGS3080AFG EGH3032AFG EGH3040AFG EGH3050AFG EGH3063AFG EGH3080AFG 100 125 125 160 160 80-100 Fixed 100-125 Fixed Moulded case switch 125-160 Fixed Moulded case switch EGB3100AFG EGB3125AFG EGE3100AFG EGE3125AFG EGS3100AFG EGS3125AFG EGB3160AFG EGE3160AFG EGS316AFFG EGH3100AFG EGH3125AFG EGK3125KSG EGH3160AFG EGK3160KSG 8 www.chscontrols.se 18 25 35 65 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Catalogue Numbers, 4 Pole MCCB with Thermal-Magnetic Trip Unit see note 12, 13, 14, 15, 16, 17, 18 Rated current In, A Adjustable range Thermal Magnetic Ir, A Im, A Catalogue numbers, complete breakers Type B Type E Type S Type H 15 16 20 25 30 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB4015FFG EGB4016FFG EGB4020FFG EGB4025FFG EGB4030FFG EGE4015FFG EGE4016FFG EGE4020FFG EGE4025FFG EGE4030FFG EGS4015FFG EGS4016FFG EGS4020FFG EGS4025FFG EGS4030FFG EGH4015FFG EGH4015FFG EGH4020FFG EGH4025FFG EGH4030FFG 32 35 40 45 50 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB4032FFG EGB4035FFG EGB4040FFG EGB4045FFG EGB4050FFG EGE4032FFG EGE4035FFG EGE4040FFG EGE4045FFG EGE4050FFG EGS4032FFG EGS4035FFG EGS4040FFG EGS4045FFG EGS4050FFG EGH4032FFG EGH4035FFG EGH4040FFG EGH4045FFG EGH4050FFG 60 63 70 80 90 Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed EGB4060FFG EGB4063FFG EGB4070FFG EGB4080FFG EGB4090FFG EGE4060FFG EGE4063FFG EGE4070FFG EGE4080FFG EGE4090FFG EGS4060FFG EGS4063FFG EGS4070FFG EGS4080FFG EGS4090FFG EGH4060FFG EGH4063FFG EGH4070FFG EGH4080FFG EGH4090FFG 100 125 160 20 25 Fixed Fixed Fixed 16-20 20-25 Fixed Fixed Fixed Fixed Fixed EGB4100FFG EGB4125FFG EGB4160FFG EGB4020AFG EGB4025AFG EGE4100FFG EGE4125FFG EGE4160FFG EGE4020AFG EGE4025AFG EGS4100FFG EGS4125FFG EGS4160FFG EGS4020AFG EGS4025AFG EGH4100FFG EGH4125FFG EGH4160FFG EGH4020AFG EGH4025AFG 32 40 50 63 80 25-32 32-40 40-50 50-63 63-80 Fixed Fixed Fixed Fixed Fixed EGB4032AFG EGB4040AFG EGB4050AFG EGB4063AFG EGB4080AFG EGE4032AFG EGE4040AFG EGE4050AFG EGE4063AFG EGE4080AFG EGS4032AFG EGS4040AFG EGS4050AFG EGS4063AFG EGS4080AFG EGH4032AFG EGH4045AFG EGH4050AFG EGH4063AFG EGH4080AFG 100 125 160 80-100 100-125 125-160 Fixed Fixed Fixed EGB4100AFG EGB4125AFG EGB4160AFG EGE4100AFG EGE4125AFG EGE4160AFG EGS4100AFG EGS4125AFG EGS416AFFG EGH4100AFG EGH4125AFG EGH4160AFG Notes 3 MCCBs with "Straight voltage rating" have been tested for use in a circuit where the nominal voltage between any two conductors does not exceed the voltage rating of the MCCB. The slash (/) between the higher and lower voltage ratings indicates that the MCCB has been tested for use in a circuit with higher voltage between phases and with the lower voltage to ground. EG-frame MCCBs have been tested for 600Y/347 and 480 V Straight per UL 489. Contact CHS Controls for application assistance. 11 690 VAC rating only apply to 160 A MCCBs. 12 Contact CHS Controls for 1-pole and 2-pole MCCBs. 13 Replace suffix "G" with "W" for no line and load terminals. Example: EGB3100FAG will be EGB3100FAW 14 The MCCBs are calibrated at 40C ambient temperature. MCCBs calibrated for 50C ambient temperature are also available, add suffix "V" to the end of the catalogue number. Example: EGB3100FAG will be EGB3100FAGV. 50C calibrated MCCBs are not UL/CSA approved. MCCBs with electronic trip units can operate reliably at 50C ambient temperature. 15 16, 32, 63 and 160 A MCCBs as well as MCCBs with adjustable thermal trip are not UL/CSA approved. 16 Moulded case switches are self protected, see page 5 for trip levels. 17 M4 hardware is included. 18 4 pole MCCBs have unprotected neutral. Replace the fourth character by "7" for 100% protected neutral. Example: EGB4100FAG will be EGB7100FAG. www.chscontrols.se 9 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Earth Leakage Modules for EG Frame MCCBs, Side Mounted test reset Rated current In, A Rated voltage Un, VAC Poles Pickup Standard setting, A Time Delay, s Alarm contacts Earth fault level Catalogue numbers 125 125 230-415 3 230-415 4 IEC IEC Inst.-1 Inst.-1 50/100% 50/100% ELEBLE3125W ELEBE4125W 0,03-10 0,03-10 Terminals, Installation Accessories for EG Frame MCCBs see note 19, 20, 21 3T125EF 3TA125EF 3TA160EFK 3TA150EF Endcap kit Multiwire teminal Spreader Description Catalogue numbers Terminals for Cu/Al cond., pressure type, 125 A, 2,5-95 mm2/AWG 14-3/0, kit of 3 Terminals for Cu/Al cond., pressure type, 125 A, 2,5-50 mm2/AWG 14-1/0, kit of 3 Terminals for Cu/Al cond., pressure type, 160 A, 16-70 mm2/AWG 6-3/0, kit of 3 Terminals for Cu/Al cond., pressure type, 160 A, 35-120 mm2/AWG-kcmil 3-250, kit of 3 Terminals for Cu/Al cond., pressure type, 160 A, 35-120 mm2/AWG-kcmil 3-250, kit of 4 3T125EF, included 3TA125EF 3TA150EF, included 3TA160EFK 4TA160EFK Endcap kit for busbar/cable lugs, 3 pole, metric hardware Endcap kit for busbar/cable lugs, 4 pole, metric hardware Endcap kit for busbar/cable lugs, 3 pole, imperial hardware Endcap kit for busbar/cable lugs, 4 pole, imperial hardware Multiwire connectors for Cu cond., 125 A, 3 wires, 2,1-13 mm2/AWG 14-6, kit of 3 EF3RTWK EF4RTWK EF3RTDK EF4RTDK 3TA100E3K Multiwire connectors for Cu cond., 125 A, 6 wires, 2,1-13 mm2/AWG 14-6, kit of 3 Control wire terminal kit, only for use with 3T125EF terminals, 12 pcs per package Spreader, pole cc=35,4 mm, 3 pole, hardware not included, use endcap kit Spreader, pole cc=35,4 mm, 4 pole, hardware not included, use endcap kit Terminal shields, ingress protection IP 30, 3 pole 3TA100E6K GCWTK EFTEW3 EFTEW4 EFTS3K Terminal shields, ingress protection IP 30, 4 pole Terminal end cover, 3 pole, conductor opening 6,4 mm, 10 pcs per package Terminal end cover, 3 pole, conductor opening 10,4 mm, 10 pcs per package Interphase barriers, 2 pcs per package Mounting adapter for 35mm DIN rail, for 3 pole and 4 pole MCCBs EFTS4K EEC3K EEC4K EIPBK EF34DIN GCWTK Interphase barrier Terminal shield Terminal end cover Plug-in Blocks for EG Frame Breakers see note 22 Plug-in block for 3 pole breaker, including breaker terminals and trip-on drawout interlock Plug-in block for 4 pole breaker, including breaker terminals and trip-on drawout interlock PAD3E PAD4E Notes 19 3TA160EFK and 4TA160EFK, terminal cover is included. 20 Multiwire terminals only to be used on 3 pole MCCBs, terminal cover is included. 21 Terminal 3T125EF is made of steel. Terminals 3TA125EF, 3TA150EF, 3TA160EFK and 4TA160EFK are made of aluminium. 22 Plug-in block can be installed either on or partly behind mounting plate. Rear terminal stabs are included. Stabs can be converted to front terminals. 10 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Internal Accessories for EG Frame MCCBs see note 23 Aux/alarm switch Shunt trip Description Catalogue Number Auxiliary contact, 1 change-over contact Auxiliary contact, 2 change-over contacts Alarm contact, 1 change-over contact Alarm contact, 2 change-over contacts Combination auxiliary and alarm contact, 1 change-over contact of each AUX1A1BPK AUX2A2BPK ALM1M1BEPK ALM2M2BEPK AUXALRMEPK Shunt trip, 120 VAC Shunt trip, 240 VAC Shunt trip, 380-600 VAC Shunt trip, 24-48 VDC Undervoltage release, 120 VAC SNT120CPK SNT120CPK SNT480APK SNT060CPK UVR120APK Undervoltage release, 208-240 VAC, 380-500 VAC Undervoltage release, 525-600 VAC Undervoltage release, 24 VAC/VDC Undervoltage release, 48 VAC Undervoltage release, 48 VDC UVR480APK UVR600APK UVR024CPK UVR048APK UVR048DPK Undervoltage release, 120 VDC UVR125DPK Undervoltage release External Accessories for EG Frame MCCBs OFF/O Trip ON/I Direct rotary handle OFF/O Trip ON/I see note 24, 25, 26 Direct (close-coupled) rotary handle Direct (close-coupled) rotary handle with door interlock Rotary through-the-door handle, black - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 609 mm shaft EHMCCB EHMCCBI EHMVD06B EHMVD12B EHMVD24B Rotary through-the-door handle, red - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 609 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 304 mm shaft EHMVD06R EHMVD12R EHMVD24R EHMVD06BX EHMVD12BX Rotary through-the-door handle, black - IP 65/NEMA 4X, 609 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 304 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 609 mm shaft Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 1,2 m wire EHMVD24BX EHMVD06RX EHMVD12RX EHMVD24RX EHMFS04 Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 2,1 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 1,2 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 2,1 m wire Motor operator, 120 VAC Motor operator, 240 VAC EMHFS07I EHMFS04X EHMFS07X EOPEF240C EOPEF240C Motor operator, 24 VDC Motor operator, 48 VDC Motor operator, 120 VDC Handle block for temporary use, padlockable in On/Off position Handle block for temporary use, padlockable in Off position Handle block, fixed mounted on breaker, padlockable in On/Off position Handle block, fixed mounted on breaker, padlockable in Off position EOPEF24D EOPEF48D EOPEF240C EFPHB EFPHBOFF EFPHL EFPHLOFF Discrimination/system design software on CD Contact CHS Controls Rotary through-the-door handle ON OFF Flexshaft mechanism, flange mounted I ON OFF O Motor operator Handle block fixed mounted Handle block temporary use Notes 23 See page 7 for possible installation combinations. 24 Rotary through-the-door handle, see page 24 for min and max enclosure depth. 25 Flexshaft mechanism, additional hardware may be required depending on enclosure type. Contact CHS Controls for more information. 26 Contact CHS Controls for breaker interlock kits and cylinder locks. www.chscontrols.se 11 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Moulded Case Circuit Breakers for Plant Protection, JG Frame 63 - 250 A, IEC/UL/CSA Breaker Capacity Breaker Rated voltage, Ue, VAC type IEC UL/CSA Breaking capacity , kA, VAC IEC 60947-2, Icu/Ics 230 400 690 UL 489/CSA 240 480 600 E S H C 65/65 85/85 100/100 200/150 65 85 100 200 18 25 35 50 690 690 690 690 600 600 600 600 25/25 40/40 70/70 100/75 12/6 12/6 14/7 20/10 25 35 65 100 Catalogue Numbers, MCCBs with Thermal-Magnetic Trip Unit see note 17, 27, 28, 29, 30 Rated current In, A Adjustable range Thermal Magnetic Ir, A Im, A Catalogue numbers Complete breakers Type E Type S Type H Type C Trip unit only 3 pole breakers 70 Fixed 90 Fixed 100 Fixed 125 Fixed 350-700 450-900 500-1000 625-1250 JGE3070FAG JGE3090FAG JGE3100FAG JGE3125FAG JGS3070FAG JGS3090FAG JGS3100FAG JGS3125FAG JGH3070FAG JGH3090FAG JGH3100FAG JGH3125FAG JGC3070FAG JGC3090FAG JGC3100FAG JGC3125FAG JT3070FA JT3090FA JT3100FA JT3125FA 150 175 200 225 250 Fixed Fixed Fixed Fixed Fixed 750-1500 875-1750 1000-2000 1125-2250 1250-2500 JGE3150FAG JGE3175FAG JGE3200FAG JGE3225FAG JGE3250FAG JGS3150FAG JGS3175FAG JGS3200FAG JGS3225FAG JGS3250FAG JGH3150FAG JGH3175FAG JGH3200FAG JGH3225FAG JGH3250FAG JGC3150FAG JGC3175FAG JGC3200FAG JGC3225FAG JGC3250FAG JT3150FA JT3175FA JT3200FA JT3225FA JT3250FA 80 100 125 160 64-80 80-100 100-125 128-160 400-800 500-1000 625-1250 800-1600 JGE3080AAG JGE3100AAG JGE3125AAG JGE3160AAG JGS3080AAG JGS3100AAG JGS3125AAG JGS3160AAG JGH3080AAG JGH3100AAG JGH3125AAG JGH3160AAG JGC3080AAG JGC3100AAG JGC3125AAG JGC3160AAG JT3080AA JT3100AA JT3125AA JT3160AA 200 250 250 250 160-200 1000-2000 200-250 1250-2500 Breaker frame only Moulded case switch JGE3200AAG JGE3250AAG JGE3250NN JGS3200AAG JGS3250AAG JGS3250NN JGH3200AAG JGH3250AAG JGH3250NN JGK3250KSG JGC3200AAG JGC3250AAG JT3200AA JT3250AA 4 pole breakers 70 Fixed 90 Fixed 100 Fixed 125 Fixed 350-700 450-900 500-1000 625-1250 JGE4070FAG JGE4090FAG JGE4100FAG JGE4125FAG JGS4070FAG JGS4090FAG JGS4100FAG JGS4125FAG JGH4070FAG JGH4090FAG JGH4100FAG JGH4125FAG JGC4070FAG JGC4090FAG JGC4100FAG JGC4125FAG JT4070FA JT4090FA JT4100FA JT4125FA 150 175 200 225 250 Fixed Fixed Fixed Fixed Fixed 750-1500 875-1750 1000-2000 1125-2250 1250-2500 JGE4150FAG JGE4175FAG JGE4200FAG JGE4225FAG JGE4250FAG JGS4150FAG JGS4175FAG JGS4200FAG JGS4225FAG JGS4250FAG JGH4150FAG JGH4175FAG JGH4200FAG JGH4225FAG JGH4250FAG JGC4150FAG JGC4175FAG JGC4200FAG JGC4225FAG JGC4250FAG JT4150FA JT4175FA JT4200FA JT4225FA JT4250FA 80 100 125 160 64-80 80-100 100-125 128-160 400-800 500-1000 625-1250 800-1600 JGE4080AAG JGE4100AAG JGE4125AAG JGE4160AAG JGS4080AAG JGS4100AAG JGS4125AAG JGS4160AAG JGH4080AAG JGH4100AAG JGH4125AAG JGH4160AAG JGC4080AAG JGC4100AAG JGC4125AAG JGC4160AAG JT4080AA JT4100AA JT4125AA JT4160AA 200 250 250 250 160-200 1000-2000 200-250 1250-2500 Breaker frame only Moulded case switch JGE4200AAG JGE4250AAG JGE4250NN JGS4200AAG JGS3250AAG JGS4250NN JGH4200AAG JGH4250AAG JGH4250NN JGK7250KSG JGC4200AAG JGC4250AAG JT4200AA JT4250AA 12 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Catalogue Numbers, MCCBs with Digitrip 310 Electronic Trip Unit see note 17, 31, 32, 33 Rated current In, A Catalogue numbers Complete breakers Type E Type S Type H Type C Trip unit only External neutral CT 3 pole breakers 50 LS 50 LSI 50 LSG 50 LSIG JGE305033G JGE305032G JGE305035G JGE305036G JGS305033G JGS305032G JGS305035G JGS305036G JGH305033G JGH305032G JGH305035G JGH305036G JGC305033G JGC305032G JGC305035G JGC305036G JT305033 JT305032 JT305035 JT305036 JGFCT050 JGFCT050 100 100 100 100 160 LS LSI LSG LSIG LS JGE310033G JGE310032G JGE310035G JGE310036G JGE316033G JGS310033G JGS310032G JGS310035G JGS310036G JGS316033G JGH310033G JGH310032G JGH310035G JGH310036G JGH316033G JGC310033G JGC310032G JGC310035G JGC310036G JGC316033G JT310033 JT310032 JT310035 JT310036 JT316033 160 160 160 250 250 LSI LSG LSIG LS LSI JGE316032G JGE316035G JGE316036G JGE325033G JGE325032G JGS316032G JGS316035G JGS316036G JGS325033G JGS325032G JGH316032G JGH316035G JGH316036G JGH325033G JGH325032G JGC316032G JGC316035G JGC316036G JGC325033G JGC325032G JT316032 JT316035 JT316036 JT325033 JT325032 250 250 LSG LSIG JGE325035G JGE325036G JGS325035G JGS325036G JGH325035G JGH325036G JGC325035G JGC325036G JT325035 JT325036 JGFCT250 JGFCT250 4 pole breakers 50 LS 50 LSI 50 LSG 50 LSIG JGE405033G JGE405032G JGE405035G JGE405036G JGS405033G JGS405032G JGS405035G JGS405036G JGH405033G JGH405032G JGH405035G JGH405036G JGC405033G JGC405032G JGC405035G JGC405036G JT405033 JT405032 JT405035 JT405036 JGFCT050 JGFCT050 JGFCT050 JGFCT050 100 100 100 100 160 LS LSI LSG LSIG LS JGE410033G JGE410032G JGE410035G JGE410036G JGE416033G JGS410033G JGS410032G JGS410035G JGS410036G JGS416033G JGH410033G JGH410032G JGH410035G JGH410036G JGH416033G JGC410033G JGC410032G JGC410035G JGC410036G JGC416033G JT410033 JT410032 JT410035 JT410036 JT416033 JGFCT100 JGFCT100 JGFCT100 JGFCT100 JGFCT160 160 160 160 250 250 LSI LSG LSIG LS LSI JGE416032G JGE416035G JGE416036G JGE425033G JGE425032G JGS416032G JGS416035G JGS416036G JGS425033G JGS425032G JGH416032G JGH416035G JGH416036G JGH425033G JGH425032G JGC416032G JGC416035G JGC416036G JGC425033G JGC425032G JT416032 JT416035 JT416036 JT425033 JT425032 JGFCT160 JGFCT160 JGFCT160 JGFCT250 JGFCT250 250 250 LSG LSIG JGE425035G JGE425036G JGS425035G JGS425036G JGH425035G JGH425036G JGC425035G JGC425036G JT425035 JT425036 JGFCT250 JGFCT250 Protection JGFCT100 JGFCT100 JGFCT160 JGFCT160 Notes 17 M4 hardware is included. 27 For 2 pole applications, use two outer poles. Contact CHS Controls for 2 pole breakers. 28 MCCBs with adjustable thermal trip are not UL/CSA approved. 29 Terminals are not included in breaker frames, must be ordered separately. 30 4 pole thermal magnetic MCCBs have unprotected neutral. Replace the fourth character by "8" for 0/60% or by "9" for 0/100% protected neutral. Example: JGH4250AAG will be JGH8250AAG. 31 Protection type Ir settings LS Long delay and short delay protection 250 A MCCB 250, 225, 200, 175, 160, 150, 125, 100. LSI Long delay, short delay and instantaneous protection 160 A MCCB 160, 150, 125, 110, 100, 90, 80, 63. LSG Long delay, short delay and earth fault protection 100 A MCCB 100, 90, 80, 70, 63, 50, 45, 40. LSIG Long delay, short delay, instantaneous and earth fault protection 50 A MCCB 50, 45, 40, 32, 30, 25, 20 32 Neutral CT is required for 4-wire systems with protected neutral and for LSG/LSIG trip units. External installation. 33 4 pole electronic trip units MCCBs have unprotected neutral. Replace the fourth character to "6" for 60% or to "7" for 100% protected neutral. Protected neutral is not adjustable. Example: JGH425033G will be JGH725033G. www.chscontrols.se 13 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Earth Leakage Modules for JG Frame MCCBs, bottom mounted WARNING reset test Rated current In, A Rated voltage Un, VAC Poles Pickup Standard setting, A Time Delay, s Alarm contacts Earth fault levels Catalogue numbers 150 150 250 250 150 230-415 230-415 230-415 230-415 120-480 3 4 3 4 3 IEC IEC IEC IEC UL/CSA 0,03-10 0,03-10 0,03-10 0,03-10 0,03-10 Inst.-1 Inst.-1 Inst.-1 Inst.-1 Inst.-1 50/100% 50/100% 50/100% 50/100% 50/100% ELJBE3160W ELJBE4160W ELJBE3250W ELJBE4250W ELJBN3150W 150 250 250 120-480 4 120-480 3 120-480 4 UL/CSA UL/CSA UL/CSA 0,03-10 0,03-10 0,03-10 Inst.-1 Inst.-1 Inst.-1 50/100% 50/100% 50/100% ELJBN4150W ELJBN3250W ELJBN4250W Terminals, Installation Accessories for JG Frame MCCBs see note 20, 34 T250FJ TA250FJ TC250FJ Multiwire terminal Spreader FJCWTK Endcap kit Interphase barrier Description Catalogue numbers Terminal for Cu cond., pressure type, 250 A, 25-185 mm2/AWG 4-350 Terminal for Cu/Al cond., pressure type, 250 A, 25-185 mm2/AWG 4-350 Terminal for Cu/Al cond., pressure type, 250 A, 25-185 mm2/AWG 4-350 Endcap kit for busbar/cable lugs, 3 pole, metric hardware Endcap kit for busbar/cable lugs, 4 pole, metric hardware T250FJ, included TA250FJ TC250FJ FJ3RTWK FJ4RTWK Endcap kit for busbar/cable lugs, 3 pole, imperial hardware Endcap kit for busbar/cable lugs, 4 pole, imperial hardware Multiwire connectors for Cu cond., 250 A, 3 wires, 2,1-13 mm2/AWG 14-6, kit of 3 Multiwire connectors for Cu cond., 250 A, 6 wires, 2,1-13 mm2/AWG 14-6, kit of 3 Control wire terminal kit, only for use with T250FJ terminals, 14 pcs per package FJ3RTDK FJ4RTDK 3TA250J3 3TA250J6 FJCWTK Spreader, pole cc=45 mm, 3 pole, hardware not included, use endcap kit Spreader, pole cc=45 mm, 4 pole, hardware not included, use endcap kit Terminal shields, ingress protection IP 30, 3 pole Terminal shields, ingress protection IP 30, 4 pole Interphase barriers, 6 pcs per package Interphase barriers, 8 pcs per package FJTEW3 FJTEW4 FJTS3K FJTS4K FJIPBK FJIPBK4 Terminal shield Plug-in Blocks for JG Frame MCCBs see note 22 Plug-in block for 3 pole breaker, including breaker terminals and trip-on drawout interlock Plug-in block for 4 pole breaker, including breaker terminals and trip-on drawout interlock PAD3J PAD4J Notes 20 Multiwire terminals only to be used on 3 pole MCCBs, terminal cover is included. 22 Plug-in block can be installed either on or partly behind mounting plate. Rear terminal stabs are included. Stabs can be converted to front terminals. 23 See page 7 for possible installation combinations. 24 Rotary through-the-door handle, see page 24 for min and max enclosure depth. 25 Flexshaft mechanism, additional hardware may be required depending on enclosure type. Contact CHS Controls for more information. 26 Contact CHS Controls for breaker interlock kits and cylinder locks. 34 Terminal T250FJ is made of stainless steel. Terminal TA250FJ is made of aluminium. Terminal TC250FJ is made of copper. 14 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Internal Accessories for JG Frame MCCBs see note 23 Aux/alarm switch Description Catalogue Number Auxiliary contact, 1 change-over contact Auxiliary contact, 2 change-over contacts Alarm contact, 1 change-over contact Alarm contact, 2 change-over contacts Combination auxiliary and alarm contact, 1 change-over contact of each AUX1A1BPK AUX2A2BPK ALM1M1BJPK ALM2M2BJPK AUXALRMJPK Shunt trip, 120 VAC Shunt trip, 240 VAC Shunt trip, 380-600 VAC Shunt trip, 24-48 VDC Undervoltage release, 120 VAC SNT120CPK SNT1200PK SNT480APK SNT060CPK UVR120APK Undervoltage release, 208-240 VAC, 380-500 VAC Undervoltage release, 525-600 VAC Undervoltage release, 24 VAC/VDC Undervoltage release, 48 VAC Undervoltage release, 48 VDC UVR480APK UVR600APK UVR024CPK UVR048APK UVR048DPK Undervoltage release, 120 VDC UVR125DPK Shunt trip Undervoltage release External Accessories for JG Frame MCCBs OFF/O Trip ON/I see note 24, 25, 26 Direct (close-coupled) rotary handle Direct (close-coupled) rotary handle with door interlock Rotary through-the-door handle, black - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 609 mm shaft JHMCCB JHMCCBI FJHMVD06B FJHMVD12B FJHMVD24B Rotary through-the-door handle, red - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 609 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 304 mm shaft FJHMVD06R FJHMVD12R FJHMVD24R FJHMVD06BX FJHMVD12BX Rotary through-the-door handle, black - IP 65/NEMA 4X, 609 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 304 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 609 mm shaft Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 1,2 m wire FJHMVD24BX FJHMVD06RX FJHMVD12RX FJHMVD24RX JHMFS04 Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 2,1 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 1,2 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 2,1 m wire Motor operator, 120 VAC Motor operator, 240 VAC JMHFS07 JHMFS04X JHMFS07X EOPFJ240C EOPFJ240C Motor operator, 24 VDC Motor operator, 48 VDC Motor operator, 120 VDC Handle block for temporary use, padlockable in On/Off position Handle block for temporary use, padlockable in Off position EOPFJ24D EOPFJ48D EOPFJ240C FJPHB FJPHBOFF Handle block, fixed mounted on breaker, padlockable in On/Off position Handle block, fixed mounted on breaker, padlockable in Off position Plug-in test kit for electronic trip units, 120 VAC power supply Plug-in test kit for electronic trip units, 230 VAC power supply Discrimination/system design software on CD FJPHL FJPHLOFF MTST120V MTST230V Contact CHS Controls Direct rotary handle OFF/O Trip ON/I Rotary through-the-door handle ON OFF Flexshaft mechanism, flange mounted I ON OFF O Motor operator Handle block fixed mounted Handle block temporary use www.chscontrols.se 15 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Moulded Case Circuit Breakers for Plant Protection, LG Frame 250 - 630 A, IEC/UL/CSA Breaker Capacity Breaker Rated voltage, Ue, VAC type IEC UL/CSA Breaking capacity , kA, VAC IEC 60947-2, Icu/Ics 230 400 690 UL 489/CSA 240 480 600 E S H C 65/65 85/85 100/100 200/150 65 85 100 200 18 25 35 50 690 690 690 690 600 600 600 600 35/35 50/50 70/70 100/75 12/6 20/10 25/13 35/18 35 50 65 100 Catalogue Numbers, MCCBs with Thermal-Magnetic Trip Unit see note 29, 35, 36 Rated current In, A Adjustable range Thermal Magnetic Ir, A Im, A Catalogue numbers Complete breakers Type E Type S Type H Type C Trip unit only 3 pole breakers 250 Fixed 300 Fixed 350 Fixed 400 Fixed 1250-2500 1500-3000 1750-3500 2000-4000 LGE3250FAG LGE3300FAG LGE3350FAG LGE3400FAG LGS3250FAG LGS3300FAG LGS3350FAG LGS3400FAG LGH3250FAG LGH3300FAG LGH3350FAG LGH3400FAG LGC3250FAG LGC3300FAG LGC3350FAG LGC3400FAG LT3250FA LT3300FA LT3350FA LT3400FA 500 600 250 320 400 Fixed Fixed 200-250 256-320 320-400 2500-5000 3000-6000 1250-2500 1600-3200 2000-4000 LGE3500FAG LGE3600FAG LGE3250AAG LGE3320AAG LGE3400AAG LGS3500FAG LGS3600FAG LGS3250AAG LGS3320AAG LGS3400AAF LGH3500FAG LGH3600FAG LGH3250AAG LGH3320AAG LGH3400AAG LGC3500FAG LGC3600FAG LGC3250AAG LGC3320AAG LGC3400AAG LT3500FA LT3600FA LT3250AA LT3320AA LT3400AA 500 630 630 400 630 400-500 2500-5000 504-630 3150-6300 Breaker frame only Moulded case switch Moulded case switch LGE3500AAF LGE3630AAG LGE3630NN LGS3500AAG LGS3630AAG LGS3630NN LGH3500AAG LGH3630AAG LGH3630NN LGK3400KSG LGK3630KSG LGC3500AAG LGC3630AAG LGC3630NN LT3500AA LT3630AA 4 pole breakers 250 Fixed 300 Fixed 350 Fixed 400 Fixed 1250-2500 1500-3000 1750-3500 2000-4000 LGE4250FAG LGE4300FAG LGE4350FAG LGE4400FAG LGS4250FAG LGS4300FAG LGS4350FAG LGS4400FAG LGH4250FAG LGH4300FAG LGH4350FAG LGH4400FAG LGC4250FAG LGC4300FAG LGC4350FAG LGC4400FAG LT4250FA LT4300FA LT4350FA LT4400FA 500 600 250 320 400 Fixed Fixed 200-250 256-320 320-400 2500-5000 3000-6000 1250-2500 1600-3200 2000-4000 LGE4500FAG LGE4600FAG LGE4250AAG LGE4320AAG LGE4400AAG LGS4500FAG LGS4600FAG LGS4250AAG LGS4320AAG LGS4400AAG LGH4500FAG LGH4600FAG LGH4250AAG LGH4320AAG LGH4400AAG LGC4500FAG LGC4600FAG LGC4250AAG LGC4320AAG LGC4400AAG LT4500FA LT4600FA LT4250AA LT4320AA LT4400AA 500 630 630 400 630 400-500 2500-5000 504-630 3150-6300 Breaker frame only Moulded case switch Moulded case switch LGE4500AAG LGE4630AAG LGE4630NN LGS4500AAG LGS4630AAG LGS4630NN LGH4500AAG LGH4630AAG LGH4630NN LGK4400KSG LGK4630KSG LGC4500AAG LGC4630AAG LGC4630NN LT4500AA LT4630AA 16 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Catalogue Numbers, MCCBs with Digitrip 310 Electronic Trip Unit see note 35, 36, 38, 39 Rated current In, A Catalogue numbers Complete breakers Type E Type S Type H Type C Trip unit only External neutral CT 3 pole breakers 250 LS 250 LSI 250 LSG 250 LSIG LGE325033G LGE325032G LGE325035G LGE325036G LGS325033G LGS325032G LGS325035G LGS325036G LGH325033G LGH325032G LGH325035G LGH325036G LGC325033G LGC325032G LGC325035G LGC325036G LT325033 LT325032 LT325035 LT325036 LGFCT250 LGFCT250 400 400 400 400 600 LS LSI LSG LSIG LS LGE340033G LGE340032G LGE340035G LGE340036G LGE360033G LGS340033G LGS340032G LGS340035G LGS340036G LGS360033G LGH340033G LGH340032G LGH340035G LGH340036G LGH360033G LGC340033G LGC340032G LGC340035G LGC340036G LGC360033G LT340033 LT340032 LT340035 LT340036 LT360033 600 600 600 630 630 LSI LSG LSIG LS LSI LGE360032G LGE360035G LGE360036G LGE363033G LGE363032G LGS360032G LGS360035G LGS360036G LGS363033G LGS363032G LGH360032G LGH360035G LGH360036G LGH363033G LGH363032G LGC360032G LGC360035G LGC360036G LGC363033G LGC363032G LT360032 LT360035 LT360036 LT363033 LT363032 630 630 LSG LSIG LGE363035G LGE363036G LGS363035G LGS363036G LGH363035G LGH363036G LGC363035G LGC363036G LT363035 LT363036 LGFCT630 LGFCT630 4 pole breakers 250 LS 250 LSI 250 LSG 250 LSIG LGE425033G LGE425032G LGE425035G LGE425036G LGS425033G LGS425032G LGS425035G LGS425036G LGH425033G LGH425032G LGH425035G LGH425036G LGC425033G LGC425032G LGC425035G LGC425036G LT425033 LT425032 LT425035 LT425036 LGFCT250 LGFCT250 LGFCT250 LGFCT250 400 400 400 400 600 LS LSI LSG LSIG LS LGE440033G LGE440032G LGE440035G LGE440036G LGE460033G LGS440033G LGS440032G LGS440035G LGS440036G LGS460033G LGH440033G LGH440032G LGH440035G LGH440036G LGH460033G LGC440033G LGC440032G LGC440035G LGC440036G LGC460033G LT440033 LT440032 LT440035 LT440036 LT460033 LGFCT400 LGFCT400 LGFCT400 LGFCT400 LGFCT600 600 600 600 630 630 LSI LSG LSIG LS LSI LGE460032G LGE460035G LGE460036G LGE463033G LGE463032G LGS460032G LGS460035G LGS460036G LGS463033G LGS463032G LGH460032G LGH460035G LGH460036G LGH463033G LGH463032G LGC460032G LGC460035G LGC460036G LGC463033G LGC463032G LT460032 LT460035 LT460036 LT463033 LT463032 LGFCT600 LGFCT600 LGFCT600 LGFCT630 LGFCT630 630 630 LSG LSIG LGE463035G LGE463036G LGS463035G LGS463036G LGH463035G LGH463036G LGC463035G LGC463036G LT463035 LT463036 LGFCT630 LGFCT630 Protection LGFCT400 LGFCT400 LGFCT600 LGFCT600 Notes 29 Terminals are not included in breaker frames, must be ordered separately. 32 Neutral CT is required for 4-wire systems with protected neutral and for LSG/LSIG trip units. External installation. 35 M5 hardware is included. 36 630 A MCCBs as well as MCCBs with adjustable thermal trip are not UL/CSA approved. 37 4 pole thermal magnetic MCCBs have unprotected neutral. Replace the fourth character by "7" for 100%, by "8" for 0-60% or by "9" for 0-100% protected neutral. Example: LGH4630AAG will be LGH7630AAG. 38 Protection type Ir settings LS Long delay and short delay protection 630 A MCCB 630, 600, 500, 400, 350, 315, 300, 250. LSI Long delay, short delay and instantaneous protection 600 A MCCB 600, 500, 450, 400, 350, 315, 300, 250. LSG Long delay, short delay and earth fault protection 400 A MCCB 400, 350, 315, 300, 300, 250, 225, 200, 160. LSIG Long delay, short delay, instantaneous and earth fault protection 250 A MCCB 250,225, 200, 175, 160, 150, 125, 100. 39 4 pole electronic trip units MCCBs have unprotected neutral. Replace the fourth character by "6" for 60% or by "7" for 100% protected neutral. Protected neutral is not adjustable. Example: LGH463033G will be LGH763033G. www.chscontrols.se 17 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Earth Leakage Modules for LG Frame MCCBs, bottom mounted WARNING reset test Rated current In, A Rated voltage Un, VAC Poles Pickup Standard setting, A Time Delay, s Alarm contacts Earth fault levels Catalogue numbers 400 400 630 630 400 230-415 230-415 230-415 230-415 120-480 3 4 3 4 3 IEC IEC IEC IEC UL/CSA 0,03-10 0,03-10 0,03-10 0,03-10 0,03-10 Inst.-1 Inst.-1 Inst.-1 Inst.-1 Inst.-1 50/100% 50/100% 50/100% 50/100% 50/100% ELLBE3400W ELLBE4400W ELLBE3630W ELLBE4630W ELLBN3400W 400 600 600 120-480 4 120-480 3 120-480 4 UL/CSA UL/CSA UL/CSA 0,03-10 0,03-10 0,03-10 Inst.-1 Inst.-1 Inst.-1 50/100% 50/100% 50/100% ELLBN4400W ELLBN3600W ELLBN4600W Terminals, Installation Accessories for LG Frame MCCBs see note 40, 41 TA632LK T632LK TA631LK T631LK TA350LK T350LK Endcap kit Spreader Interphase barrier Description Catalogue numbers Terminal for Cu/Al cond., pressure type, 400 A, 35-240 mm2/AWG 2-500 Terminal for Cu cond., pressure type, 400 A, 35-240 mm2/AWG 2-500 Terminals for Cu/Al cond., pressure type, 400 A, 240-380 mm2/kcmil 500-750, kit of 3 Terminals for Cu cond., pressure type, 400 A, 240-380 mm2/kcmil 500-750, kit of 3 Terminals for Cu/Al cond., pressure type, 400 A, 240-380 mm2/kcmil 500-750, kit of 4 TA350LK, included T350LK 3TA631LK 3T631LK 4TA631LK Terminals for Cu cond., pressure type, 400 A, 240-380 mm2/kcmil 500-750, kit of 4 Terminals for Cu/Al cond., pressure type, 630 A, 2*35-240 mm2/AWG 2*2-500, kit of 3 Terminals for Cu cond., pressure type, 630 A, 2*35-240 mm2/AWG 2*2-500, kit of 3 Terminals for Cu/Al cond., pressure type, 630 A, 2*35-240 mm2/AWG 2*2-500, kit of 4 Terminals for Cu cond., pressure type, 630 A, 2*35-240 mm2/AWG 2*2-500, kit of 4 4T631LK 3TA632LK, included 3T632LK 4TA632LK, included 4T632LK Endcap kit for busbar/cable lugs, 3 pole, metric hardware Endcap kit for busbar/cable lugs, 4 pole, metric hardware Endcap kit for busbar/cable lugs, 3 pole, imperial hardware Endcap kit for busbar/cable lugs, 4 pole, imperial hardware Spreader, pole cc=54 mm, 3 pole, hardware not included, use endcap kit L3RTWK L4RTWK L3RTDK L4RTDK LGTEW3 Spreader, pole cc=54 mm, 4 pole, hardware not included, use endcap kit Terminal shields, ingress protection IP 30, 3 pole Terminal shields, ingress protection IP 30, 4 pole Interphase barriers, 2 pcs per package LGTEW4 LTS3K LTS4K IPB3 Terminal shield Plug-in Blocks for LG Frame MCCBs see note 22 Plug-in block for 3 pole breaker, including breaker terminals and trip-on drawout interlock Plug-in block for 4 pole breaker, including breaker terminals and trip-on drawout interlock PAD3L PAD4L Notes 22 Plug-in block can be installed either on or partly behind mounting plate. Rear terminal stabs are included. Stabs can be converted to front terminals. 23 See page 7 for possible installation combinations. 24 Rotary through-the-door handle, see page 24 for min and max enclosure depth. 25 Flexshaft mechanism, additional hardware may be required depending on enclosure type. Contact CHS Controls for more information. 26 Contact CHS Controls for breaker interlock kits and cylinder locks. 40 Terminal cover is included for terminals 3TA631LK, 3T631LK, 4TA631LK, 4T631LK, 3TA632LK, 3T632LK, 4TA632LK and 4T632LK. 41 Terminals TA350LK, 3TA631LK, 4TA631LK, 3TA632LK and 4TA632LK are made of aluminium. Terminals T350LK, 3T631LK, 4T631LK, 3T632LK and 4T632LK are made of copper. 18 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Internal Accessories for LG Frame MCCBs see note 23 Aux/alarm switch Description Catalogue Number Auxiliary contact, 1 change-over contact Auxiliary contact, 2 change-over contacts Alarm contact, 1 change-over contact Alarm contact, 2 change-over contacts Combination auxiliary and alarm contact, 1 change-over contact of each AUX1A1BPK AUX2A2BPK ALM1M1BJPK ALM2M2BJPK AUXALRMJPK Shunt trip, 120 VAC Shunt trip, 240 VAC Shunt trip, 380-600 VAC Shunt trip, 24-48 VDC Undervoltage release, 120 VAC SNT120CPK SNT1200PK SNT480APK SNT060CPK UVR120APK Undervoltage release, 208-240 VAC, 380-500 VAC Undervoltage release, 525-600 VAC Undervoltage release, 24 VAC/VDC Undervoltage release, 48 VAC Undervoltage release, 48 VDC UVR480APK UVR600APK UVR024CPK UVR048APK UVR048DPK Undervoltage release, 120 VDC UVR125DPK Shunt trip Undervoltage release External Accessories for LG Frame MCCBs see note 24, 25, 26 OFF/O Trip ON/I Direct (close-coupled) rotary handle Direct (close-coupled) rotary handle with door interlock Rotary through-the-door handle, black - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, black - IP 54/NEMA 12, 609 mm shaft LHMCCB LHMCCBI KLHMVD06B KLHMVD12B KLHMVD24B Rotary through-the-door handle, red - IP 54/NEMA 12, 152 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 304 mm shaft Rotary through-the-door handle, red - IP 54/NEMA 12, 609 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, black - IP 65/NEMA 4X, 304 mm shaft KLHMVD06R KLHMVD12R KLHMVD24R KLHMVD06BX KLHMVD12BX Rotary through-the-door handle, black - IP 65/NEMA 4X, 609 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 152 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 304 mm shaft Rotary through-the-door handle, red - IP 65/NEMA 4X, 609 mm shaft Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 1,2 m wire KLHMVD24BX KLHMVD06RX KLHMVD12RX KLHMVD24RX LHMFS04 Flexshaft mechanism, flange mounted handle - IP 54/NEMA 12, 2,1 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 1,2 m wire Flexshaft mechanism, flange mounted handle - IP 65/NEMA 4X, 2,1 m wire Motor operator, 120 VAC Motor operator, 240 VAC LMHFS07 LMHFS04X LMHFS07X EOPLG240C EOPLG240C Motor operator, 24 VDC Motor operator, 48 VDC Motor operator, 120 VDC Handle block for temporary use, padlockable in On/Off position Handle block for temporary use, padlockable in Off position EOPLG24D EOPLG48D EOPLG240C LBHP LBHPOFF Handle block, fixed mounted on breaker, padlockable in On/Off position Handle block, fixed mounted on breaker, padlockable in Off position Plug-in test kit for electronic trip units, 120 VAC power supply Plug-in test kit for electronic trip units, 230 VAC power supply Discrimination/system design software on CD LPHL LPHLOFF MTST120V MTST230V Contact CHS Controls Direct rotary handle OFF/O Trip ON/I Rotary through-the-door handle ON OFF Flexshaft mechanism, flange mounted I ON OFF O Motor operator Handle block fixed mounted Handle block temporary use www.chscontrols.se 19 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Moulded Case Circuit Breakers for Motor Starters EG - LG Frame 3 - 600 A, IEC/UL/CSA Combination Ratings see note 42 Breaker Rated voltage, Ue, VAC frame IEC UL/CSA Combination ratings with Eaton's Cutler-Hammer starters, kA, VAC IEC 60947-4-1 UL 489/CSA 230 400 240 480 600 EG JG LG 100/65 65 65 25 25 25 690 690 690 600Y/347 600 600 100/65 65 65 100 100 100 100 100 100 Catalogue Numbers, 3 Pole MCCBs with Magnetic Trip Unit for Starter Combinations see note 43, 44, 45, 46 Rated current In, A Adjustable settings Magnetic Im, A Catalogue numbers Complete circuit breakers EG Frame JG Frame 3 7 15 30 9, 15, 21, 27, 30, 33 21, 35, 49, 63, 70, 77 45, 75, 105, 135, 150, 165 90, 150, 210, 270, 300, 330 HMCPE003A0C HMCPE007C0C HMCPE015E0C HMCPE030H1C 50 70 100 100 250 150, 250, 350, 450, 500 ,550 210, 350 ,490, 630, 700, 770 300, 500, 700, 900, 1000, 1100 500, 750, 1000, 1250, 1375, 1500 500-1000 HMCPE050K2C HMCPE070M2C HMCPE100R3C HMCPE100T3C 250 250 250 250 250 625-1250 750-1500 875-1750 1000-2000 1125-2250 HMCPJ250F5L HMCPJ250G5L HMCPJ250J5L HMCPJ250K5L HMCPJ250L5L 250 600 600 600 600 1250-2500 1125-2250 1500-3000 1750-3500 2000-4000 HMCPJ250W5L 600 600 600 2250-4500 2500-5000 3000-6000 LG Frame HMCPJ250D5L HMCPL600L HMCPL600N HMCPL600R HMCPL600X HMCPL600Y HMCPL600P HMCPL600M Notes 42 Combination ratings per IEC 60947-4-1, Type 2 coordination, are based on combination use with Eaton's Cutler-Hammer IT Starters. The UL/CSA approval is based on combination use with Eaton's Cutler-Hammer IT and Freedom Series starters. Contact CHS Controls for coordination information. 43 The MCCBs can be used for DC applications, max 250 VDC. 44 Trip levels for DC applications, actual trip level is approximately 40% higher than values shown. 45 Contact CHS Controls for MCCBs for thermal magnetic motor protection MCCBs according to IEC 60947-4. 46 For accessories see page 10 for EG frame, 14 for JG frame and page 18 for LG frame. 20 www.chscontrols.se Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Dimensions, Moulded Case Circuit Breakers, mm 25,4 cc poles see note 47, 48 25,4 cc poles 140 140 140 14 102 76 EG Frame, 3 pole, Front View 76 EG Frame, 4 pole, Front View EG Frame, Side View 35,5 cc poles 35,5 cc poles 178 178 105 178 140 JG Frame, 3 pole, Front View 43,5 cc poles 23 JG Frame, 4 pole Front View 90 JG Frame, Side View 43,5 cc poles 257 139 LG Frame, 3 pole, Front View 257 183 LG Frame, 4 pole Front View 257 27 109 LG Frame, Side View Notes 47 EG frame mounted on DIN rail increases depth with 9 mm. 48 Terminal shields on EG frame add 46 mm to line/load side, terminal shields on JG frame add 48 mm to line/load side and terminal shields on LG frame add 54 mm to line/load side. www.chscontrols.se 21 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Dimensions, MCCBs with Earth Leakage Protection Modules, mm see note 47, 48, 49 25,4 cc poles 25,4 cc poles 140 140 140 14 204 178 EG Frame, 3 pole, Front View 35,5 cc poles EG Frame, 4 pole, Front View EG Frame, Side View 35,5 cc poles 286 286 105 286 23 140 JG Frame, 3 pole, Front View 43,5 cc poles JG Frame, 4 pole, Front View 90 JG Frame, Side View 43,5 cc poles 390 139 LG Frame, 3 pole, Front View 22 76 390 183 LG Frame, 4 pole, Front View www.chscontrols.se 390 27 111 LG Frame, Side View Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Dimensions, Moulded Case Circuit Breaker Plug-In Blocks, mm 15 see note 50 90 15 65 172 65 120 4 120 14 25,4 76 60 25,4 78 103 EG Frame, 3 pole Bottom View EG Frame, 4 pole Bottom View 15 EG Frame, Side View 123 220 15 90 90 140 140 5 23 35 90 70 35 142 107 JG Frame, 3 pole Bottom View JG Frame, 4 pole Bottom View JG Frame, Side View 170 310 15 15 121 121 181 181 10 27 44 109 90 44 142 LG Frame, 3 pole Bottom View 186 LG Frame, 4 pole Bottom View LG Frame, Side View Notes 47 EG frame mounted on DIN rail increases depth with 9 mm. 48 Terminal shields on EG frame add 46 mm to line/load side, terminal shields on JG frame add 48 mm to line/load side and terminal shields on LG frame add 54 mm to line/load side. 49 Earth leakage protection module for EG frame, interconnection cables are included. Load terminals are located at the bottom of earth leakage protection module. 50 Plug-in block can be installed partly behind mounting plate (as illustrated) or on mounting plate. Stabs can be converted to front terminals, contact CHS Controls for dimensions. www.chscontrols.se 23 Eaton's Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A Dimensions, Moulded Case Circuit Breakers with Rotary Handle Mechanisms, mm 152 mm shaft: Max 245 305 mm shaft: Max 398 610 mm shaft: Max 703 152 mm shaft: Max 276 305 mm shaft: Max 400 610 mm shaft: Max 734 50 JG Frame, Direct Rotary Handle 152 mm shaft: Max 314 305 mm shaft: Max 467 610 mm shaft: Max 772 LG Frame, Rotary Through-the-Door handle LG Frame, Direct Rotary Handle nglig - Alltid o pp tillga e tl id n! www.chscontrols.se Alw CHS Controls AB Florettgatan 33 SE-254 67 Helsingborg, Sweden Phone +46 42 386100, fax +46 42 386129 chs@chscontrols.se www.chscontrols.se 208 ay op s av ailable - Always Catalogue PM1043E April 2005 JG Frame, Rotary Through-the-Door handle 171 ! 50 EG Frame, Direct Rotary Handle en EG Frame, Rotary Through-the-Door handle 131 Al 50