www.kavlico.com 6
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of
contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use
or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for
the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition,
deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not
been expressly agreed by us prior to the sale of our products.
How to Order
Example:
PTE5000 -060 - 2 - B - 1 - A
Description:
PTE5000 Sensor, 0 - 60 Bar Gage, 0.5 - 4.5 VDC Ratiometric Electrical Output, Flourocarbon FKM (Viton) External O-
Ring, G1/4” A DIN 3582-E Pressure Connection, with Built-in Connector Compatible with DIN175301-803 A (18mm)
060PTE5000 2 B 1 A
Pressure Ranges Bar
006 0 – 6
010 0 – 10
016 0 – 16
025 0 – 25
040 0 – 40
060 0 – 60
100 0 – 100
160 0 – 160
250 0 – 250
400 0 – 400
600 0 – 600
Built-in Electrical Connection
A Compatible with DIN 175301-803 A (18 mm)
Sensor delivered without mating connector
B GDS 307 Industrial Standard (9.4 mm)
Sensor delivered without mating connector
C M12 - 4 pole
Sensor delivered without mating connector
D Packard Metri-Pack 150
Sensor delivered without mating connector
Pressure Connection (port)
1 G1/4”A DIN 3852-E
2 7/16”-20 UNF-2B (female) SAE J1926/1 (modified)
with 45° cone and schrader. only for pressure range 006 - 060
3 7/16”-20 UNF-2A (male) SAE J1926/2 (modified)
with 45° cone, only for pressure range 006 - 060
4 G1/4”A DIN 3852-A
Output
1 4 - 20 mA
2 0.5 – 4.5 VDC ratiometric
3 0 – 5 VDC
4 0 –10 VDC
External O-ring
A None
B Fluorocarbon FKM (Viton)
only for pressure port option 1
lower temperature limited to -20°C
C Aluminium Washer G1/4
only for pressure port option
washer will be fixed with plastic cap
D Copper Washer G1/4
only for pressure port option
washer will be fixed with plastic cap
Data Sheet PTE5000