Continued from the preceding page.
Murata Code
Capacitance Change from 25°C (%)
–55°C –30°C –10°C
Max. Min. Max. Min. Max. Min.
5C/5G 0.58 –0.24 0.40 –0.17 0.25 –0.11
6C 0.87 –0.48 0.59 –0.33 0.38 –0.21
6P 2.33 0.72 1.61 0.50 1.02 0.32
6R 3.02 1.28 2.08 0.88 1.32 0.56
6S 4.09 2.16 2.81 1.49 1.79 0.95
6T 5.46 3.28 3.75 2.26 2.39 1.44
7U 8.78 5.04 6.04 3.47 3.84 2.21
EIA Code
4C 2.56 –1.88 1.54 –1.13 1.02 –0.75
3P – – 1.65 0.14 1.10 0.09
3R – – 2.03 0.45 1.35 0.30
3S – – 2.63 0.95 1.76 0.63
3T – – 3.40 1.58 2.27 1.05
3U – – 4.94 2.84 3.29 1.89
3C 1.37 –0.90 0.82 –0.54 0.55 –0.36
Murata Code
Capacitance Change from 20°C (%)
–55°C –25°C –10°C
Max. Min. Max. Min. Max. Min.
2C 0.82 –0.45 0.49 –0.27 0.33 –0.18
2P – – 1.32 0.41 0.88 0.27
2R – – 1.70 0.72 1.13 0.48
2S – – 2.30 1.22 1.54 0.81
2T – – 3.07 1.85 2.05 1.23
1X ––––––
oCapacitance Change from each temperature
JIS Code
uCapacitance
Expressed by three-digit alphanumerics. The unit is picofarad
(pF). The first and second figures are significant digits, and the
third figure expresses the number of zeros which follow the two
numbers.If there is a decimal point, it is expressed by the capital
letter "R." In this case, all figures are significant digits.
R50
1R0
100
103
Ex.)
0.5pF
1.0pF
10pF
10000pF
Code Capacitance
yRated Voltage
0E
0G
0J
1A
1C
1E
YA
1H
2A
2D
2E
YD
DC2.5V
DC4V
DC6.3V
DC10V
DC16V
DC25V
DC35V
DC50V
DC100V
DC200V
DC250V
DC300V
Code Rated Voltage
2W
2H
2J
3A
3D
3F
BB
E2
GC
GF
GD
GB
DC450V
DC500V
DC630V
DC1kV
DC2kV
DC3.15kV
DC350V (for Camera Flash Circuit)
AC250V
X1/Y2; AC250V (Safety Standard Certified Type GC)
Y2, X1/Y2; AC250V (Safety Standard Certified Type GF)
Y3; AC250V (Safety Standard Certified Type GD)
X2; AC250V (Safety Standard Certified Type GB)
Code Rated Voltage
Continued on the following page.