SPECIFICATION
MODEL RS-75-3.3 RS-75-5 RS-75-12 RS-75-15 RS-75-24 RS-75-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
15A 12A 6A 5A 3.2A 1.6A
0~15A 0~12A 0~6A 0~5A 0~3.2A 0~1.6A
49.5W 60W 72W 75W 76.8W 76.8W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
3V~3.6V 4.75~5.5V 10.8~13.2V 13.5~16.5V 22~27.6V 42~54V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5%
0.5%
0.5%
0.5%
0.5% 0.5%
0.5% 0.5%2.0% 1.0%
500ms,20ms,50ms/230VAC1200ms,30ms,10ms/115VACatfullload
88~264VAC125~373VDC(300VACpeak5sec.Nodamage)
47~63Hz
72%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
76% 81% 82% 85% 86%
2A/115VAC1.2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
-20~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
265Khrsmin.MIL-HDBK-217F(25 )
129*97*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:RS-75-SPEC2004-03-12
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
0.41Kg;30pcs/12.3Kg/0.72CUFT
75WSingleOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
Features :
RS-75 seri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
ENVIRONMENT
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note6)
PROTECTION
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
MechanicalSpecification CaseNo.903Unit:mm
FileName:RS-75-SPEC2004-03-12
AMBIENTTEMPERATURE( )
LOAD(%)
-20
-20
0
0
2010 30 40
20
40
80
60
100
6050
5
8.2
4
3
2
1
9 .5
4.5 73.5
9
3 .5
3
8
3 33 3 1
122.5
129
9
8
9
2
-M 3
78 5 .5
1 8
3 -M 3
1 8 .5
9 .5
120
6.5
77
32
3 .5
3 .5
3 .5
70
OutputDeratingVSInputVoltage
INPUTVOLTAGE(VAC)60Hz
88 10095 120115 160140 200180 240220 264
LOAD(%)
Ta=25
90
100
80
70
60
50
40
Others
3.3V,5V
TerminalPin.No Assignment
PinNo. PinNo.
1
2
4
3
5
Assignment Assignment
DCOUTPUT -V
DCOUTPUT +V
FG
AC/L
AC/N
OutputDerating
75WSingleOutputSwitchingPowerSupply RS-75 se ri es