SPECIFICATION
S-150-5 S-150-7.5 S-150-9 S-150-12 S-150-13.5 S-150-15 S-150-24 S-150-27 S-150-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.5
OVERVOLTAGE
ACCURRENT (Typ.)
5V 7.5V 9V 12V 13.5V 15V 24V 27V 48V
30A 20A 16.7A 12.5A 11.2A 10A 6.5A 5.6A 3.2A
0~30A 0~20A 0~16.7A 0~12.5A 0~11.2A 0~10A 0~6.5A 0~5.6A 0~3.2A
150W 150W 150.3W 150W 151.2W 150W 156W 151.2W 153.6W
150mVp-p 150mVp-p 180mVp-p 180mVp-p 180mVp-p 180mVp-p 240mVp-p 240mVp-p 240mVp-p
4.5~5.5V 6~8.3V 8~10.4V 10.6~13.2V 12~15V 13.5~16.5V 21~28V 24~30V 43~53V
2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.3% 0.3% 0.3% 0.3%
0.3% 0.3% 0.3% 0.3%
0.2% 0.2% 0.2%
0.5% 0.5% 0.2% 0.2% 0.2%
100ms,50msatfullload
28msatfullload
88~132VAC/176~264VACselectedbyswitch248~370VDC
47~63Hz
78%
5.75~6.75V
80%
8.63~10.13V
80%
10.35~12.2V
82%
13.8~16.2V
83%
15.53~18.2V
84%
17.25~20.3V
85%
30~34.8V
86%
31.1~36.45V
87%
55.2~64.8V
3.2A/115VAC1.6A/230VAC
COLDSTART 35A
<3.5mA /240VAC
105~150% ratedoutputpower
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
286.7Khrsmin.MIL-HDBK-217F(25 )
199*110*50mm(L*W*H)
0.8Kg;16pcs/13.8Kg/0.95CUFT
FileName:S-150-SPEC2009-03-04
SAFETY STANDARDS UL1012,UL60950-1, TUVEN60950-1,CCCGB4943approved
CompliancetoEN55022(CISPR22)ClassB
HARMONICCURRENT
EMSIMMUNITY
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,lightindustrylevel,criteria A
150WSingleOutputSwitchingPowerSupply S-150 series
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25KHz
2 years warranty
Features :
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
EMICONDUCTION&RADIATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed.