Additional Resources: Product Page | 3D Model date 12/14/2020 page 1 of 6 SERIES: VGS-100D DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES * * * * * * * * wide input range (85 ~ 305 VAC) available with conformal coating or terminal cover options active Power Factor Correction (PFC) certified to IEC/EN/UL 62368 designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943 output over voltage, over current, over temperature, short circuit protection CISPR/EN55032 Class B radiated/conducted emissions input over voltage category III for fixed installations MODEL output voltage output current output power ripple and noise2 efficiency3 max (A) max (W) max (mVp-p) typ (%) (Vdc) range1 (Vdc) 5 4.75 ~ 5.5 20.0 100.0 100 86 VGS-100D-12 12 11.4 ~ 13.8 8.5 102.0 100 85 VGS-100D-15 15 14.3 ~ 16.5 6.7 100.5 100 86 VGS-100D-24 24 22.8 ~ 27.6 4.2 100.8 150 86 VGS-100D-48 48 45.6 ~ 55.2 2.1 100.8 250 87 VGS-100D-5 Notes: 1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage and output power do not exceed stated limits. 2. Ripple & noise are measured at 20 MHz BW with 47 F aluminum electrolytic capacitor and 0.1 F ceramic capacitor on the output. 3. Measured at 230 Vac PART NUMBER KEY VGS-100D - XX - X Base Number Output Voltage cui.com A - with terminal cover B - with conformal coating Additional Resources: Product Page | 3D Model CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY date 12/14/2020 page 2 of 6 INPUT parameter conditions/description min max units 5 Vdc output model 85 120 264 373 Vac Vdc all other output models 85 120 305 430 Vac Vdc 47 63 Hz 1.7 1.3 0.7 A A A voltage frequency current at 85 Vac at 115 Vac at 230 Vac inrush current at 115 Vac, cold start at 230 Vac, cold start leakage current at 240 Vac power factor at 115 Vac, full load at 230 Vac, full load 0.97 0.92 parameter conditions/description min capacitive load 5 Vdc output 12 Vdc output 15 Vdc output 24 Vdc output 48 Vdc output initial set point accuracy at full load 5, 12 & 15 Vdc output 24 & 48 Vdc output typ 25 45 A A 2 mA max units 5,000 5,000 5,000 4,200 2,200 F F F F F OUTPUT line regulation load regulation 0%~100% load 5 Vdc output model all other output models hold-up time at 230 Vac 2 1 % % 0.5 % 1.0 0.5 % % 0.05 %/C 16 temperature coefficient remote on/off (CTRL) typ ms turn on (0 ~ 0.8 Vdc) turn off (4 ~ 10 Vdc) PROTECTIONS parameter conditions/description min over voltage protection 5 Vdc output model, hiccup 12 Vdc output model, hiccup 15 Vdc output model, hiccup 24 Vdc output model, hiccup 48 Vdc output model, hiccup over current protection constant current, auto-recovery over temperature protection1 over temperature protection activation over temperature protection deactivation short circuit protection constant current, continuous, auto-recovery Note: 1. Over temperature protection thresholds under full load conditions. cui.com typ 105 50 max units 7.5 16.8 20.25 32.4 60.0 Vdc Vdc Vdc Vdc Vdc 150 % 85 C C Additional Resources: Product Page | 3D Model CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY date 12/14/2020 page 3 of 6 SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to ground, 1 min, <10mA input to output, 1 min, <10mA output to ground, 1 min, <5mA min typ safety approvals certified to 62368: IEC, EN, UL designed to meet 60335: EN designed to meet 61558: EN designed to meet GB4943 safety class Class I conducted emissions CISPR32/EN55032 CLASS B radiated emissions CISPR32/EN55032 CLASS B harmonic current IEC/EN61000-3-2 voltage flicker IEC/EN 61000-3-3 ESD IEC/EN 61000-4-2 Contact 6KV/Air 8KV perf. Criteria A radiated immunity IEC/EN61000-4-3 3V/m perf. Criteria B EFT/burst IEC/EN61000-4-4 2KV perf. Criteria A surge IEC/EN61000-4-5 line to line 1kV/line to ground 2kV perf. Criteria A conducted immunity IEC/EN61000-4-6 10Vr.m.s perf. Criteria A voltage dips and interruptions IEC/EN61000-4-11 0%, 70% perf. Criteria B MTBF as per MIL-HDBK-217F at 25C RoHS yes max 2,000 4,000 500 units Vac Vac Vac 300,000 hours ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature typ max units -30 70 C -40 85 C operating humidity non-condensing 20 90 % storage humidity non-condensing 10 95 % cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY date 12/14/2020 page 4 of 6 MECHANICAL parameter conditions/description dimensions 179 x 99 x 30 weight 5 Vdc output model all other models cooling natural convection case material metal (AL1100, SGCC) min 530 460 units: mm [inch] tolerance: 1.0 [0.039] wire range: 22-12 AWG connector tightening torque: M3.5, 0.8 N*m PIN CONNECTIONS Function 1 +Vo 2 +Vo 3 -Vo 4 -Vo 5 6 AC(N) 7 AC(L) Note: At least one hole position, 1 ~ 6 , must be securely connected to Protective Earth (PE). CN1: KANGDAO TJC3-NAWD-2P PIN FUNCTION CONNECTOR TERMINAL 1 RC+ 2 RC- KANGDAO XI-25001-2Y KANGDAO XH2.54-TE POSITION SCREW SPEC L (MAX) TORQUE (MAX) 1~6 M4 4mm 0.9N*m max units mm MECHANICAL DRAWING PIN typ cui.com g g Additional Resources: Product Page CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY | 3D Model date 12/14/2020 page 5 of 6 DERATING CURVE EFFICIENCY CURVES cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY date 12/14/2020 page 6 of 6 REVISION HISTORY rev. 1.0 description date initial release 12/14/2020 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.