Low Power V.22 bis Modem CMX868A
© 2008 CML Microsystems Plc 43 D/868A/3
Rx Modem S1 Pattern Detector
(DPSK and QAM modes) Notes Min. Typ. Max. Units
Will detect S1 pattern lasting for 90.0 – – ms
Will not detect S1 pattern lasting for – – 72.0
Hold time (minimum detector ‘On’ time) 5.0 – – ms
Rx Modem Energy Detector Notes Min. Typ. Max. Units
Detect threshold (‘Off’ to ‘On) 10,11 – – -43.0 dBm
Undetect threshold (‘On’ to ‘Off’) 10,11 -48.0 – – dBm
Hysteresis 10,11 2.0 – – dB
Detect (‘Off’ to ‘On’) response time
QAM and DPSK modes 10,11 10.0 – 35.0 ms
300 and 1200 baud FSK modes 10,11 8.0 – 30.0 ms
150 and 75 baud FSK modes 10,11 16.0 – 60.0 ms
Undetect (‘On’ to ‘Off’) response time
QAM and DPSK modes 10,11 10.0 – 55.0 ms
300 and 1200 baud FSK modes 10,11 10.0 – 40.0 ms
150 and 75 baud FSK modes 10,11 20.0 – 80.0 ms
Rx Answer Tone Detectors Notes Min. Typ. Max. Units
Detect threshold (‘Off’ to ‘On) 10,12 – – -43.0 dBm
Undetect threshold (‘On’ to ‘Off’) 10,12 -48.0 – – dBm
Hysteresis 10,12 2.0 – – dB
Detect (‘Off’ to ‘On’) response time 10,12 30.0 33.0 45.0 ms
Undetect (‘On’ to ‘Off’) response time 10,12 7.0 18.0 25.0 ms
2100Hz detector
‘Will detect’ frequency 2050 – 2160 Hz
‘Will not detect’ frequency – – 2000 Hz
2225Hz detector
‘Will detect’ frequency 2160 – 2285 Hz
‘Will not detect’ frequency 2335 – – Hz
Rx Call Progress Energy Detector Notes Min. Typ. Max. Units
Bandwidth (-3dB points) See Figure 7a 275 – 665 Hz
Detect threshold (‘Off’ to ‘On) 10,13 – – -37.0 dBm
Undetect threshold (‘On’ to ‘Off’) 10,13 -42.0 – – dBm
Detect (‘Off’ to ‘On’) response time 10,13 30.0 36.0 45.0 ms
Undetect (‘On’ to ‘Off’) response time 10,13 6.0 8.0 50.0 ms
Notes: 10. Rx 2 or 4-wire line signal level assuming 1dB loss in line coupling transformer with Rx
Gain Control block set to 0dB and external components as section 4.2.
11.Thresholds and times measured with random data for QAM and DPSK modes, continuous
binary ‘1’ for all FSK modes. Fixed compromise line equaliser enabled. Signal switched
between off and -33dBm.
12. ‘Typical’ value refers to 2100Hz or 2225Hz signal switched between off and -33dBm.
Times measured wrt. received line signal.
13. ‘Typical’ value refers to 400Hz signal switched between off and -33dBm.