DS27005 Rev. 4 - 2 1 of 3 PR2001G - PR2007G
www.diodes.com ã Diodes Incorporated
PR2001G - PR2007G
2.0A FAST RECOVERY GLASS PASSIVATED RECTIFIER
Features
DO-15
Dim Min Max
A25.40 ¾
B5.50 7.62
C0.686 0.889
D2.60 3.60
All Dimensions in mm
Maximum Ratings and Electrical Characteristics @ TA = 25°C unless otherwise specified
·Glass Passivated Die Construction
·Fast Switching for High Efficiency
·Surge Overload Rating to 80A Peak
·Low Reverse Leakage Current
·Lead Free Finish, RoHS Compliant (Note 4)
Mechanical Data
·Case: DO-15
·Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
·Moisture Sensitivity: Level 1 per J-STD-020C
·Terminals: Finish – Tin. Solderable per MIL-STD-202,
Method 208
·Polarity: Cathode Band
·Marking: Type Number
·Ordering Information: See Page 3
·Weight: 0.4 grams (approximate)
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristic Symbol PR
2001G
PR
2002G
PR
2003G
PR
2004G
PR
2005G
PR
2006G
PR
2007G Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage (Note 5)
VRRM
VRWM
VR
50 100 200 400 600 800 1000 V
RMS Reverse Voltage VR(RMS) 35 70 140 280 420 560 700 V
Average Rectified Output Current
(Note 1) @ TA = 55°CIO2.0 A
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave Superimposed on Rated Load IFSM 80 A
Forward Voltage Drop @ IF = 2.0A VFM 1.3 V
Peak Reverse Current @ TA = 25°C
at Rated DC Blocking Voltage (Note 5) @ TA = 100°CIRM 5.0
100 mA
Reverse Recovery Time (Note 3) trr 150 250 500 ns
Typical Total Capacitance (Note 2) CT35 pF
Typical Thermal Resistance Junction to Ambient RqJA 50 °C/W
Operating and Storage Temperature Range Tj, TSTG -65 to +150 °C
Notes: 1. Valid provided that leads are maintained at ambient temperature at a distance of 9.5mm from the case.
2. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
3. Measured with IF = 0.5A, IR = 1.0A, Irr = 0.25A. See figure 5.
4. RoHS revision 13.2.2003. Glass and high temperature solder exemptions applied, see EU Directive Annex Notes 5 and 7.
5. Short duration pulse test used to minimize self-heating effect.