SPECIFICATION
MODEL RQ-125B RQ-125C RQ-125D
DCVOLTAGE
RATEDCURRENT
OUTPUT VOLTAGE ADJ.RANGE
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V -5V 5V 15V -5V 12V-15V 24V5V -12V-12V
11A 4.5A 1A 10A 4A 1A 2.5A0.5A 2A8A 0.5A0.5A
2~12A
0.5~4.5A
0.1~1A 2~12A 0.5~4A 0.1~1A 0.5~4A0~1A
0.1~2.5A
2~12A 0~1A0~1A
120W 122.5W 124W
80mVp-p
120mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
120mVp-p
80mVp-p
150mVp-p
80mVp-p 80mVp-p80mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V CH1:4.75~5.5V
2.0% +8,-3% +6,-10% 2.0% +8,-3% +6,-10% +8,-3% 8.0%5.0% 2.0% 5.0%5.0%
0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 1.0%1.0% 1.0%0.5% 1.0%1.0%
1.0% 3.0% 6.0% 1.0% 3.0% 6.0% 3.0%2.0% 5.0%1.0% 2.0%2.0%
500ms,20ms,20ms/230VAC1200ms,30ms,10ms/115VACatfullload
47~63Hz
79% 82%80%
CH1:5.75~6.75V
3A/115VAC2A/230VAC
COLDSTART 50A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
-20~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
203.1Khrsmin.MIL-HDBK-217F(25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
FileName:RQ-125-SPEC2004-03-25
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
199*98*38mm(L*W*H)
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
125WQuadOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
Features :
RQ-125 seri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
CURRENTRANGE Note.6
RATEDPOWER Note.6
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note7)
88~132VAC/176~264VACselectedbyswitch248~373VDC(300VACpeak5sec.Nodamage)
0.7Kg;20pcs/14Kg/0.72CUFT