SPECIFICATION
120W PWM output LED power supply PWM-120 series
File Name:PWM-120-SPEC 2015-05-08
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME Note.2
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
12V 24V 36V 48V
10A 5A 3.4A 2.5A
120W 120W 122.4W 120W
0 ~ 100%
300Hz
±4.0% ±4.0% ±2.0% ±1.0%
500ms, 80ms 230VAC / 115VAC at full load
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88% 90% 90% 90.5%
<0.25mA / 277VAC
108 ~ 120% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
228.7K hrs min. MIL-HDBK-217F (25 )℃
191*63*37.5mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
Protection type : Shut down o/p voltage, re-power on to recover
DIMMING RANGE
PWM FREQUENCY (Typ.)
VOLTAGE TOLERANCE
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V
1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC
PWM-120-12 PWM-120-24 PWM-120-36 PWM-120-48
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge L-N : 2KV), criteria A
EMC EMISSION
COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
μ
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
0.97Kg; 15pcs/15.6Kg/0.74CUFT
UL8750, CSA C22.2 No. 250. , ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN60335-113-12
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed