SINGLE PHASE 10 AMP BRIDGE RECTIFIERS
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=50 C
Dimensions in inches and (millimeters)
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 5.0A D.C.
Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C
BR1005 BR101 BR102 BR104 BR106 BR108 BR1010 UNITS
50 100 200 400 600 800 1000 V
50 100 200 400 600 800 1000 V
35 70 140 280 420 560 700
10
200
10
200
-65 +150
-65 +125
V
A
A
V
µA
µA
BR1005 BR1010THRU
1.1
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
BR-10
.750
(19.1)
.296(7.5)
.255(6.5)
.520(13.2)
.480(12.2)
.770(19.6)
.730(18.5)
.770(19.6)
.730(18.5)
HOLE FOR
NO. 6 SCREW
MIN.
.052(1.3) DIA.
.048(1.2) TYP.
+
AC
AC
FEATURES
* Low leakage current
* Low forward voltage
* Mounting: Hole thru for #6 screw
* Mounting position: Any
10.0 Amperes
Storage Temperature Range, TSTG
Operating Temperature Range, TJ
C
C
174
0.1
1.0
.01
10
50
RATING AND CHARACTERISTIC CURVES (BR1005 THRU BR1010)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FIG.1-TYPICAL FORWARD CURRENT
AVERAGE FORWARD CURRENT,(A)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
2
4
6
8
10
12
3.0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
DERATING CURVE
0.1
1.0
.01
10
50
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V)
Pulse Width 300us
1% Duty Cycle
0 .2 .4 .6 .8 1.0 1.2 1.4
3.0
REVERSE LEAKAGE CURRENT, ( A)µ
0 25 50 75 100 125 150 175
Tj=25 C
Tj=25 C
0
100
50
150
250
200
NUMBER OF CYCLES AT 60Hz
1 10 5 50 100
Tj=25 C 8.3ms Single Half
Sine Wave
JEDEC method
CASE TEMPERATURE,( C)
0
PEAK FORWARD SURGE CURRENT,(A)
20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
0
175