ISO Symbols
Automatic Drain Manual Drain
Olympian
Filter
3/4
"
, 1
",
1 1/4
"
, 1 1/2
"
Port Sizes
Olympian plug in design
High efficiency water and particle removal
Technical Data
Fluid: Compressed air
Maximum pressure:
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Metal bowl: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Partical removal: 5, 25 or 50 µm. Within ISO 8573-1, Class 3 and
Class 5
Typical flow at 6,3 bar (90 psig) inlet pressure and a droop of
0,5 bar (7 psig):
50 µm element: 185 dm3/s (393 scfm)
Automatic drain connection: 1/8
"
Automatic drain operating conditions:
Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm3/s (2 scfm) required to close drain.
Nominal bowl size:
0,5 litre (1 pint US)
Materials:
Body: Aluminium
Yoke: Aluminium
Metal bowl: Aluminium
Sight glass: Pyrex
Element: Sintered bronze
Elastomers: Synthetic rubber
N/AL.8.261.100.02 7/97
Typical Performance Characteristics
F15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
FLOW CHARACTERISTICS
0 50 100 150 200 250 dm3/s
AIR FLOW
0 100 200 300 400 500 600 scfm
0,8
0,6
0,4
0,2
0
PRESSURE DROP
bar g
1
8
6
4
2
0
psig
UNPORTED
50 µm ELEMENT
INLET PRESSURE - bar g (psig)
2,5
(36) 4,0
(58) 6,3
(91) 8,0
(116) 10,0
(150)
Ordering Information. Models listed include ISO G threads, automatic drain, 50 µm element.
For replacement Filter (without yoke) substitute ‘0’ at 4th and ‘O’ at 10th digits eg: F15-000-A3HO.
Port Size Model Weight kg (lb)
G3/4 F15-600-A3HD 2,72 (6.04)
G1 F15-800-A3HD 2,60 (5.78)
G1 1/4 F15-A00-A3HD 2,70 (6.00)
G1 1/2 F15-B00-A3HD 2,54 (5.64)
Alternative Models F 1 -
5 -
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Option Substitute
Standard 0 0
Element Substitute
5 µm 1
25 µm 2
50 µm 3
Drain Substitute
Automatic A
Manual M
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Option Substitute
Standard bowl, with sight glass H
Standard bowl, without sight glass G
Accessories
Wall Mounting Bracket
G3/4 18-001-979
G1 18-001-979
G1 1/4 18-001-978
G1 1/2 N/A
Minimum clearance required to remove bowl.
* 200 mm (7.87) for 1 1/4
"
and 1 1/2
"
models
7/97 N/AL.8.261.100.03
F15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
257 (10.1)†
45 (1.77)
235 (9.25)
61 (2.40)
269 (10.6)†
45 (1.77)
242 (9.53)
61 (2.40)
G1/8 G1/8
G1/8
190 (7.48)*
50 (1.97)
100 (3.94)
112 (4.41)
F15 (automatic drain) F15 (manual drain)
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
N/AL.8.261.100.04 7/97
F15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Service kit Automatic drain F15-100A
Manual drain F15-100M
Replacement 5 µm 5576-97
elements 25 µm 5576-98
50 µm 5576-99
Replacement Pyrex 5872-99
Sight Glass
Replacement Automatic 3000-97
Drains Manual 684-84
Manual drain service kit includes; insert retaining ring, valve spring,
50 µm element, drain cock body, drain cock spindle assembly and
necessary seals and ‘o’ rings.
Automatic drain service kit includes; cap strainer, strainer, valve
spring, 50 µm element and necessary seals and ‘o’ rings.
7/97 N/AL.8.261.105.01
F53
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
It is recommended that an appropriate pre-
filter be fitted upstream of these units to
remove coarse contaminants.
ISO Symbol
Automatic Drain
Olympian
Puraire High Efficiency Coalescing Filter
1/2
"
, 3/4
"
, 1
"
Port Sizes
Olympian plug-in design
Coalescing element removes sub-micron particles
and converts oil and water mist to liquid form to drain
away
Automatic drain is operated by liquid level and also
opens on depressurisation
Oil and dirt contamination in outlet air within
ISO 8573.1 Quality Class 1.7.2
Technical Data
Fluid: Compressed air
Maximum pressure:
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Metal bowl: -20° to +65°C (0° to +150°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Partical removal: 0,01 µm
Maximum remaining oil content: 0,01 ppm at +21°C (+70°F) with
an inlet concentration of 15 ppm.
Maximum flow at 6,3 bar (90 psig) inlet pressure†:
G1/2, CDS15 element: 35 dm3/s (74 scfm)
G3/4, CDS25 element: 35 dm3/s (74 scfm)
G1, CDS25 element: 60 dm3/s (127 scfm)
† To maintain stated oil removal performance
Automatic drain connection: 1/8
"
Automatic drain operating conditions:
Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm3/s (2 scfm) required to close drain.
Nominal bowl sizes:
1 litre (1 quart US)
0,5 litre (1 pint US)
Materials:
Body: Aluminium
Yoke:Aluminium
Metal bowl: Aluminium
Element and activated carbon pack: Composite materials
Elastomers: Synthetic rubber
N/AL.8.261.105.02 7/97
Typical Performance Characteristics
F53
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Accessories
Wall Mounting Bracket
G3/4 18-001-979
G1 18-001-979
G1 1/4 18-001-978
G1 1/2 N/A
Inlet Pressure Maximum Flow*
G1/2 G3/4 G1
CDS15 CDS25 CDS25
bar (psig) dm3/s (scfm) dm3/s (scfm) dm3/s (scfm)
1 (15) 14 (30) 14 (30) 24 (51)
3 (45) 24 (51) 24 (51) 41 (87)
5 (70) 31 (66) 31 (66) 53 (112)
6,3 (90) 35 (74) 35 (74) 60 (127)
7 (100) 36,7 (78) 36,7 (78) 63 (133)
9 (130) 42 (89) 42 (89) 72 (153)
* Maximum flow to maintain stated oil removal performance.
Ordering Information. Models listed include ISO G threads, automatic drain.
For replacement Filter (without yoke) substitute ‘0’ at 4th and ‘O’ at 10th digits eg: F53-025-A0GO.
Port Size Model Weight kg (lb)
G1/2 F53-415-A0GD 2,38 (5.29)
G3/4 F53-625-A0MD 2,72 (6.04)
G1 F53-825-A0MD 2,66 (5.91)
Alternative Models F 5 -
3 -
Port Size Substitute
1/2
"
4*
3/4
"
6
1
"
8
Option Substitute
CDS15, short bowl 1 5*
CDS25, long bowl 2 5
Element Substitute
Oil removal 0
Drain Substitute
Automatic A
Manual M
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Option Substitute
Short bowl, without sight glass G*
Long bowl, without sight glass M
* 1/2 only available with CS15 element and short bowl.
Minimum clearance required to remove bowl.
7/97 N/AL.8.261.105.03
F53
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
CDS25 (long bowl) CDS15 (short bowl)
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
1/2
"
model 18-001-979
Wall Bracket 3/4
"
model 18-001-979
1
"
model 18-001-979
320 (12.6)†
296 (11.7)
G1/8
G1/8
45 (1.77)
190 (7.48)
50 (1.97)
100 (3.94)
112 (4.41)
257 (10.1)†
45 (1.77)
235 (9.25)
G1/8
G1/8
N/AL.8.261.105.04 7/97
F53
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Service kit CDS15 standard bowl F53-100
CDS25 long bowl F53-120
Gasket kit F53-GK
Replacement drain Automatic 3000-04
Service kit includes; element kit and necessary seals and ‘o’ rings.
7/97 N/AL.8.261.110.01
F52
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
It is recommended that an appropriate pre-
filter be fitted upstream of these units to
remove coarse contaminants.
ISO Symbol
Automatic Drain
Olympian
Ultraire Oil Removing Coalescing Filter
1/2
"
, 3/4
"
, 1
"
Port Sizes
Olympian plug-in design
Oil mist contamination in outlet air normally complies
with BS 4275 (1974)†
Provide two stage filtration. Main coalescing filter
element removes sub-micron particles and converts
oil and water mist to liquid form to drain away.
Activated carbon pack in second stage acts as an
adsorbent to assist in the removal of some hydro-
carbon gases and any oil carry-over from previous
stage
Ultra high efficiency, suitable for instrumentation,
paint spraying, food handling and similar demanding
applications
Oil and dirt contamination in outlet air within
ISO 8573.1 Quality Class 1.7.1
These units will not remove carbon monoxide, carbon dioxide
or other toxic gases or fumes.
Technical Data
Fluid: Compressed air
Maximum pressure:
Metal bowl: 17 bar (250 psig)
Operating temperature*: -20° to +65°C (0° to +150°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Partical removal: 0,01 µm.
Maximum remaining oil content: 0,003 ppm at +21°C (+70°F) with
an inlet concentration of 15 ppm
Approximate flow at 6,3 bar (90 psig) inlet pressure†:
G1/2, CDS15 element: 25 dm3/s (53 scfm)
G3/4, CDS25 element: 35 dm3/s (74 scfm)
G1, CDS25 element: 60 dm3/s (127 scfm)
† To maintain stated oil removal performance
Automatic drain connection: 1/8
"
Automatic drain operating conditions:
Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm3/s (2 scfm) required to close drain.
Nominal bowl sizes:
1 litre (1 quart US)
0,5 litre (1 pint US)
Materials:
Body: Aluminium
Yoke:Aluminium
Metal bowl: Aluminium
Sight glass: Pyrex
Element and activated carbon pack: Composite materials
Elastomers: Synthetic rubber
N/AL.8.261.110.02 7/97
Typical Performance Characteristics
F52
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information. Models listed include ISO G threads, automatic drain.
Port Size Model Weight kg (lb)
G1/2 F52-415-AAGD 4,44 (9.87)
G3/4 F52-625-AAMD 5,05 (11.22)
G1 F52-825-AAMD 5,05 (11.22)
Alternative Models F 5 -
2 -
Port Size Substitute
1/2
"
4*
3/4
"
6
1
"
8
Option Substitute
CDS15, short bowl 1 5*
CDS25, long bowl 2 5
Element Substitute
Activated carbon A
Drain Substitute
Automatic A
Manual M
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Option Substitute
Short bowl, without sight glass G*
Long bowl, without sight glass M
Accessories
Wall Mounting Bracket
G1/2 18-001-979
G3/4 18-001-979
G1 18-001-979
Inlet Pressure Maximum Flow*
G1/2 G3/4 G1
CDS15 CDS25 CDS25
bar (psig) dm3/s (scfm) dm3/s (scfm) dm3/s (scfm)
1 (15) 10 (21) 14 (30) 24 (51)
3 (45) 17,25 (37) 24 (51) 41 (87)
5 (70) 22,25 (47) 31 (66) 53 (112)
6,3 (90) 25 (53) 35 (74) 60 (127)
7 (100) 26,25 (56) 36,7 (78) 63 (133)
9 (130) 30 (64) 42 (89) 72 (153)
* Maximum flow to maintain stated oil removal performance.
* 1/2 only available with CS15 element and short bowl.
Minimum clearance required to remove bowl.
7/97 N/AL.8.261.110.03
F52
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
320 (12.6)†
45 (1.77)
G1/8
315 (12.4)
50 (1.97)
100 (3.94)
112 (4.41)
296 (11.7)
G1/8
257 (10.1)†
45 (1.77)
235 (9.25)
G1/8
G1/8
CDS25 (long bowl) CDS15 (short bowl)
334 (13.1)
315 (12.4)
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
1/2
"
model 18-001-979
Wall Bracket 3/4
"
model 18-001-979
1
"
model 18-001-979
N/AL.8.261.110.04 7/97
F52
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Service kit CDS15 standard bowl F52-100
CDS25 long bowl F52-120
Replacement CDS15 standard bowl 665-72
Carbon Element CDS25 long bowl 665-70
Gasket kit F52-GK
Replacement drain Automatic 3000-04
Service kit includes; first stage element kit, second stage element kit
and necessary seals and ‘o’ rings.
7/97 N/AL.8.261.200.01
R15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
ISO Symbols
Relieving Non Relieving
Olympian
Regulator
3/4
"
, 1
",
1 1/4
"
,1 1/2
"
Port Sizes
Olympian plug in design
Robust and compact
High flow unit with large valve and diaphragm
Push to lock adjusting knob with tamper resistant
option
Excellent flow and regulation characteristics
Technical Data
Fluid: Compressed air
Maximum pressure:
20 bar (290 psig)
Operating temperature*:
-20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Typical flow at 10 bar (150 psig) inlet pressure, 6,3 bar
(90 psig) set pressure and a droop of 1 bar (15 psig) from set:
180 dm3/s (381 scfm)
Gauge ports: ISO G1/8
Materials:
Body: Aluminium
Bonnet: Aluminium
Adjusting knob: Acetal resin
Valve: Brass
Optional T-bar adjusting screw: Steel
Yoke:Aluminium
N/AL.8.261.200.02 7/97
Typical Performance Characteristics
R15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
FLOW CHARACTERISTICS
0 50 100 150 200 250 dm3/s
AIR FLOW
0 100 200 300 400 500 600 scfm
8
6
4
2
0
PRESSURE DROP
bar g
100
80
60
40
20
0
psig
UNPORTED
INLET PRESSURE - 10 bar g (150 psig)
RANGE: 0,4 to 8 bar (5 to 120 psig)
Ordering Information. Models listed include ISO G threads, knob adjustment, relieving diaphragm, 0,3 to 10 bar (5 to 150 psig) outlet
pressure adjustment range* without gauge.
For replacement Regulator (without yoke) substitute ‘0’ at 4th and ‘O’ at 10th digits eg: R15-000-RNLO.
Port Size Model Weight kg (lb)
G3/4 R15-600-RNLD 2,04 (4.53)
G1 R15-800-RNLD 2,04 (4.53)
G1 1/4 R15-A00-RNLD 2,08 (4.62)
G1 1/2 R15-B00-RNLD 2,12 (4.71)
Alternative Models
R 1 -
5 -
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Option Substitute
Adjusting knob 0 0
T-bar 0 1**
Max. adjustment 2 0***
Gauge Substitute
With G
Without N
Type Substitute
Relieving R
Non relieving N
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Outlet Pressure Adjustment Range* Substitute
0 to 4 bar (0 to 60 psig) F
0,4 to 8 bar (5 to 120 psig) L
0,7 to 17 bar (10 to 250 psig) S**
* Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
** Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute ‘01’ at the
5th and 6th digits and ‘S’ at the 9th
position.
*** Contact Technical Sales for setting
conditions.
* Reduces by 4 mm (0.16
"
) with knob in locked
position. Add 37 mm (1.46
) for unit with T-handle
Minimum clearance required to remove unit.
** 200 mm (7.87) for 1 1/4
"
and 1 1/2
"
models
7/97 N/AL.8.261.200.03
R15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
222 (8.74)†
60 (2.36)
198 (7.80)*
54 (2.13)
G1/8
190 (7.48)**
50 (1.97)
100 (3.94)
112 (4.41)
Accessories
Ø 50 mm
Wall Mounting Bracket Key Lock Bonnet Pressure Gauge R1/8 Connection 1/8 PTF Connection
G3/4 18-001-979 5803-98 4 bar (60 psig): 18-013-012 18-013-202
G1 18-001-979 10 bar (150 psig): 18-013-013 18-013-204
G1 1/4 18-001-978 25 bar (360 psig): 18-013-014 18-013-206
G1 1/2 N/A
N/AL.8.261.200.04 7/97
R15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Service kit Relieving R15-100R
Non relieving R15-100N
Service kit includes, valve spring, slip ring, valve assembly,
diaphragm assembly and necessary seals and ‘o’ rings.
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
7/97 N/AL.8.261.300.01
B15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
ISO Symbols
Automatic Drain
Relieving Manual Drain
Relieving
Olympian
Filter/Regulator
3/4
"
, 1
",
1 1/4
"
, 1 1/2
"
Port Sizes
Olympian plug in design
High Efficiency water and particle removal
Push to lock adjusting knob with tamper resistant
option
Technical Data
Fluid: Compressed air
Maximum pressure:
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Metal bowl: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Partical removal: 5, 25 or 50 µm. Within ISO 8573-1, Class 3 and
Class 5
Typical flow at 10 bar (150 psig) inlet pressure, 6,3 bar
(90 psig) set pressure and a droop of 1 bar (15 psig) from set:
230 dm3/s (487 scfm)
Automatic drain connection: 1/8
"
Automatic drain operating conditions:
Minimum pressure: 0,7 bar (10 psig).
Drain opens when bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm3/s (2 scfm) required to close drain.
Nominal bowl size:
0,5 litre (1 pint US)
Gauge ports: ISO G1/8
Materials:
Body: Aluminium
Bonnet: Aluminium
Adjusting knob: Acetal resin
Valve: Brass
Optional T-bar adjusting screw: Steel
Yoke: Aluminium
Metal bowl: Aluminium
Sight glass: Pyrex
Element: Sintered bronze
Elastomers: Synthetic rubber
Automatic Drain
Non Relieving Manual Drain
Non Relieving
N/AL.8.261.300.02 7/97
Typical Performance Characteristics
B15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
FLOW CHARACTERISTICS
0 50 100 150 200 250 dm3/s
AIR FLOW
0 100 200 300 400 500 scfm
8
6
4
2
0
PRESSURE DROP
bar g
100
80
60
40
20
0
psig
UNPORTED
INLET PRESSURE - 10 bar g (150 psig)
RANGE: 0,4 to 8 bar (5 to 120 psig)
Ordering Information. Models listed include ISO G threads, knob adjustment, automatic drain, 50 µm element, relieving diaphragm
and 0,3 to 10 bar (5 to 150 psig) outlet pressure adjustment range* without gauge.
For replacement Filter/Regulator (without yoke) substitute ‘0’ at 4th and ‘O’ at 10th digits eg: B15-096-F3LO.
Port Size Model Weight kg (lb)
G3/4 B15-696-F3LD 3,16 (7.02)
G1 B15-896-F3LD 3,12 (6.93)
G1 1/4 B15-A96-F3LD 3,14 (6.98)
G1 1/2 B15-B96-F3LD 3,18 (7.07)
Alternative Models
B 1 -
5 -
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Option Substitute
With sight glass, relieving 9 6
Without sight glass, relieving 2 4
With sight glass, non relieving 9 8
Without sight glass, non relieving 2 6
Element Substitute
5 µm 1
25 µm 2
50 µm 3
Adjustment Substitute
Knob B
T-bar A**
Drain Substitute
Automatic F
Manual B
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Outlet Pressure Adjustment Range* Substitute
0 to 4 bar (0 to 60 psig) F
0,4 to 8 bar (5 to 120 psig) L
0,7 to 17 bar (10 to 250 psig) S**
* Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
** Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute ‘A’ at the
1st digit and ‘S’ at the 9th position.
* Reduces by 4 mm (0.16
"
) with knob in locked
position. Add 37 mm (1.46
"
) for unit with ‘T’ handle
Minimum clearance required to remove bowl.
** 200 mm (7.87) for 1 1/4
"
and 1 1/2
"
models
7/97 N/AL.8.261.300.03
B15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
54 (2.13)
190 (7.48)**
50 (1.97)
100 (3.94)
112 (4.41)
352 (13.9)†
140 (5.51)*
328 (12.9)*
61 (2.40)
G1/8
G1/8
54 (2.13)
364 (14.3)†
140 (5.51)*
340 (12.9)*
61 (2.40)
G1/8
Accessories
Ø 50 mm
Wall Mounting Bracket Key Lock Bonnet Pressure Gauge R1/8 Connection 1/8 PTF Connection
G3/4 18-001-979 5803-98 4 bar (60 psig): 18-013-012 18-013-202
G1 18-001-979 10 bar (150 psig): 18-013-013 18-013-204
G1 1/4 18-001-978 25 bar (360 psig): 18-013-014 18-013-206
G1 1/2 N/A
B15 (automatic drain) B15 (manual drain)
N/AL.8.261.300.04 7/97
B15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Automatic drain, relieving B15-100RA
Service kit Manual drain, relieving B15-100RM
Automatic drain, non relieving B15-100NA
Manual drain, non relieving B15-100NM
Replacement 5 µm 5576-97
elements 25 µm 5576-98
50 µm 5576-99
Replacement Pyrex 5827-99
Sight Glass
Replacement Automatic 3000-97
Drains Manual 684-84
Manual drain service kit includes; insert retaining ring, valve spring,
50 µm element, slip ring, valve assembly, diaphragm assembly,
drain cock body, drain cock spindle assembly and necessary seals
and ‘o’ rings.
Automatic drain service kit includes; cap strainer, strainer, valve
spring, 50 µm element, slip ring, valve assembly, diaphragm
assembly and necessary seals and ‘o’ rings.
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
7/97 N/AL.8.261.400.01
L15
Ordering Information
See
Ordering Information
on the following
pages.
ISO Symbol
Olympian
Micro-Fog and Oil-Fog Lubricator
3/4
"
, 1, 1 1/4
"
, 1 1/2
"
Port Siz es
Olympian plug-in design
Built in flow sensor gives almost consistant oil/air
ratio over a wide range of flows
0,5 and 1 litre (1 pint and 1 quart US) models can be
filled under pressure
Simple and accurate drip rate adjustment, snap
action lock
Ideal for general lubrication applications
Use Micro-Fog models in applications with one or more points of
lubrication.
Use Oil-Fog models to lubricate a single tool, cylinder or other air
driven device.
Use Fixed Venturi for high flow general purpose applications.
Technical Data
Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature*: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Start point (i.e. minimum flow required for lubricator operation) at
6,3 bar (90 psig) inlet pressure:
Micro-Fog: 6 dm3/s (13 scfm)
Oil-Fog: 6 dm3/s (13 scfm)
Fixed venturi: 52 dm3/s (110 scfm)
Typical flow at 6,3 bar (90 psig) inlet pressure and 0,5 bar
(7 psig) pressure drop:
Micro-Fog and Oil-Fog: 175 dm3/s (370 scfm)
Fixed venturi: 400 dm3/s (848 scfm)
Nominal bowl sizes:
0,5 litre (1 pint US)
1 litre (1 quart US)
8 litre (2 gallons US)
20 litre (5 gallons US)
Recommended lubricants: See page N/AL.8.900.935
Materials:
Body: Aluminium
Yoke: Aluminium
Bowl, 0,5 litre (1 pint US) and 1 litre (1 quart US): Aluminium
Bowl sight glass: Pyrex
Reservoirs, 8 litre (2 gallons US) and 20 litre (5 gallons US):
Steel
Reservoir sight tube: Polythene
Elastomers: Synthetic rubber
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.261.400.02 7/97
Typical Performance Characteristics
L15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Alternative Models
INLET PRESSURE: bar g (psig)
FLOW CHARACTERISTICS
0 40 80 120 160 200 dm3/s
AIR FLOW
0 80 160 240 320 400 480 scfm
0,8
0,6
0,4
0,2
0
PRESSURE DROP
bar g
10
8
6
4
2
0
psig
MICRO FOG
UNPORTED
2,5
(36) 4,0
(58) 6,3
(91) 8,0
(116) 10,0
(150)
INLET PRESSURE: bar g (psig)
FLOW CHARACTERISTICS
0 100 200 300 400 500 dm3/s
AIR FLOW
0 200 400 600 800 1 000 scfm
0,8
0,6
0,4
0,2
0
PRESSURE DROP
bar g
10
8
6
4
2
0
psig
FIXED VENTURI
PORT SIZE 1 1/2
"
2,5
(36) 4,0
(58) 6,3
(91) 8,0
(116) 10,0
(150)
INLET PRESSURE: bar g (psig)
FLOW CHARACTERISTICS
0 40 80 120 160 200 dm3/s
AIR FLOW
0 80 160 240 320 400 480 scfm
0,8
0,6
0,4
0,2
0
PRESSURE DROP
bar g
10
8
6
4
2
0
psig
OIL FOG
UNPORTED
2,5
(36) 4,0
(58) 6,3
(91) 8,0
(116) 10,0
(150)
Ordering Information. Models listed include ISO G threads, 0,5 litre (1 pint US) reservoir without drain.
Type Port Size Model Weight kg (lb)
G3/4 L15-600-MP9D 2,31 (5.13)
Micro-Fog G1 L15-800-MP9D 2,25 (5.00)
G1 1/4 L15-A00-MP9D 2,29 (5.09)
G1 1/2 L15-B00-MP9D 2,33 (5.18)
Options Substitute
Standard 0
Fixed venturi 1*
Type Substitute
Oil-Fog O*
Micro-Fog M
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel G
Bowl Substitute
0,5 litre (1 pint US), no drain 9
1 litre (1 quart US), no drain 8
0,5 litre (1 pint US) with drain 7
1 litre (1 quart US) with drain D
8 litre (2 gallons US) J
20 litre (5 gallons US) K
L 1 -
50-P
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
* Fixed venturi, Oil Fog only
Wall Mounting Bracket Tamper Resistant Wire Quick Fill Nipple Level Switch Remote Fill Kit
G3/4 18-001-979 2117-01 (pack of 10) 18-011-021 8 litre: 18-007-975 18-027-980
G1 18-001-979 20 litre: 18-007-974
G1 1/4 18-001-978
G1 1/2 N/A
7/97 N/AL.8.261.400.03
L15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
595 (23.4)
305 (12.0)42 (1.65)
490 (19.3)
252 (9.92)42 (1.65)
Dimensions mm (inches)
Minimum clearance required to remove bowl.
* For 1/4 turn manual drain add 16 mm (0.63
"
) on 0,5 and
1 litre bowls.
** 200 mm (7.87
"
) for 1 1/4
"
and 1 1/2
"
models.
0,5 litre
1 litre
8 litre 20 litre
Accessories
N/AL.8.261.400.04 7/97
L15
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Service Kits
Item Type Part Number
Service kit Micro-Fog L15-100M
Oil-Fog L15-100O
Replacement
Sight Glass for Pyrex 5872-99
0,5 litre (1 pint US) bowls
Replacement Drain Manual 684-84
Service kit includes sight dome assembly, screen, filler plug, ball,
threaded cap and necessary seals and o-rings. Oil-Fog service kit
also contains spring.
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
7/97 N/AL.8.261.500.01
V15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
ISO Symbol
Olympian
Pressure Relief Valve
3/4
"
, 1
",
1 1/4
"
, 1 1/2
"
, Port Sizes
Olympian plug in design
Helps protect compressed air systems from over
pressure by retarding excessive pressure build up
High relief capacity, sensitive and accurate
Integral pilot operated design, suitable for in-line or
indirect mounting
Threaded relief port for silencer or piped exhaust
Technical Data
Fluid: Compressed air
Operating temperature*:
-20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Gauge ports: ISO G1/8
Exhaust port: ISO G1
Materials:
Body: Aluminium
Intermediate body: Aluminium
Bonnet: Aluminium
Bottom plug: Aluminium
Adjusting screw: Steel
Elastomers: Synthetic rubber
Yoke: Aluminium
N/AL.8.261.500.02 7/97
Typical Performance Characteristics
V15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
FLOW CHARACTERISTICS
0 50 100 150 200 250 dm3/s
RELIEF AIR FLOW
0 100 200 300 400 500 600 scfm
16
14
12
10
8
6
4
2
0
RELIEF PRESSURE
bar g
200
160
120
80
40
0
psig
UNPORTED
RANGE: 1 to 10 bar (15 to 150 psig)
Ordering Information. Models listed include ISO G threads, 1 to 10 bar (15 to 150 psig) operating adjustment range* without gauge.
Port Size Model Weight kg (lb)
G3/4 V15-603-NNMD 2,21 (4.91)
G1 V15-803-NNMD 2,20 (4.89)
G1 1/4 V15-A03-NNMD 2,22 (4.93)
G1 1/2 V15-B03-NNMD 2,26 (5.02)
Alternative Models V 1 -
5 -
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Option Substitute
Slotted screw 0 3
Relief Pressure Substitute
Not set N Gauge Substitute
With G
Without N
Thread Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Outlet Pressure Adjustment Range* Substitute
0,4 to 4 bar (0 to 60 psig) F
1 to 10 bar (15 to 150 psig) M
0.7 to 17 bar (10 to 250 psig) S
* Relief valve can be adjusted to pressures in
excess of, and less than, those specified.
Do not use these units to control pressures
outside of the specified ranges.
Accessories
Ø 50 mm
Wall Mounting Bracket Pressure Gauge R1/8 Connection 1/8 PTF Connection Silencer
G3/4 18-001-979 4 bar (60 psig): 18-013-012 18-013-202 MB008B (R1)
G1 18-001-979 10 bar (150 psig): 18-013-013 18-013-204
G1 1/4 18-001-978 25 bar (360 psig): 18-013-014 18-013-206
G1 1/2 N/A
* Minimum clearance required to remove unit.
200 mm (7.87) for 1 1/4
"
and 1 1/2
"
models
7/97 N/AL.8.261.500.03
V15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
256 (10.1)*
50 (1.97)
232 (9.13)
190 (7.48)†
50 (1.97)
100 (3.94)
G1/8
Service Kits
Item Part Number
Service kit V15-100
Service kit includes, valve spring, slip ring, valve assembly,
pilot diaphragm assembly and necessary seals and o-rings.
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
N/AL.8.261.500.04 7/97
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
V15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
9/97 N/AL.8.261.600.01
T15
Olympian
Shut-off & Lockout Valves
3/4
"
,1
",
1 1/4
"
, 1 1/2
"
Port Sizes
Olympian plug in design
Quick action 1/4 turn from full flow to exhaust
T15 3-port/2-position shut-off valves with exhaust
Valves can be locked in open or closed position
Use upstream or downstream of air processing units
Low pressure drop ball valve design
Technical Data
Fluid: Compressed air
Maximum Pressure: 17 bar (250 psig)
Operating Temperature*: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Cv factor from IN to OUT ports**: 27,5
Materials:
Body: Aluminium
Handle: Zinc
Seals: PTFE
Ball: Brass
Ordering Information
See
Ordering Information
on the following
page.
ISO Symbols
2-Port/2-Position 3-Port/2-Position
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
-
N/AL.8.261.600.02 9/97
Ordering Information. Models listed have ISO G threads and include screws and seals for yoke connection.
T15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
65 (2.56)15* (0.59)
100 (3.94)
62 (2.44)43 (1.69)
95 (3.74)
20 (0.79)
50 (1.97)
Service Kits
Item Part Number
Service kit T15-800-100
Service kit includes thrust bearing, Teflon seats, stem seal, gland,
stem nut, and necessary o-rings.
3-Port/2-Position 2-Port/2-Position
Port Size Threaded Exhaust Port (M5) Weight kg (lbs) No Exhaust Outlet Weight kg (lbs)
G3/4 T15-600-E2AD 1,00 (2.21) T15-600-B2AD 1,00 (2.21)
G1 T15-800-E2AD 0,96 (2.12) T15-800-B2AD 0,87 (1.92)
G1 1/4 T15-A00-E2AD 0,94 (2.07) T15-A00-B2AD 1,00 (2.21)
G1 1/2 T15-B00-E2AD 0,98 (2.16) T15-B00-B2AD 0,98 (2.16)
T 1 5 0-20 A
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Ball Type Substitute
Non exhaust B
Exhaust E
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel D
Alternative Models
* 20 mm (0.79
) for
G1 1/2 model.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
8/97 N/AL.8.261.700.01
Accessories
Olympian Series 15
System Accessories
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Olympian Series 15 System Components
Bracket and Connector Kits
Tamper Resistant Kits
Lubricator Fill Devices
Porting Block
Silencers
Nuts held captive in yoke
– no spanner required.
N/AL.8.261.700.02 8/97
OLYMPIAN SERIES 15 ACCESSORIES
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Single Yoke
Part Number: 5519-98
125 (4.92)
50 (1.97)
100 (3.94)
DoubleYoke
Part Number: 5519-51
50 (1.97)
250 (9.84)
100 (3.94)
Single Unidaptor
Port Size
G1/2 Y15-400-10DD
G3/4 Y15-600-10DD
G1 Y15-800-10DD
G1 1/4 Y15-A00-10DD
G1 1/2 Y15-B00-10DD
Rc1/2 Y15-400-10BB
Rc3/4 Y15-600-10BB
Rc1 Y15-800-10BB
Rc1 1/4 Y15-A00-10BB
Rc1 1/2 Y15-B00-10BB
N.P.T. 1/2 Y15-400-10AA
N.P.T. 3/4 Y15-600-10AA
N.P.T. 1 Y15-800-10AA
N.P.T. 1 1/4 Y15-A00-10AA
N.P.T. 1 1/2 Y15-B00-10AA
50 (1.97)
190 (7.48)
100 (3.94)
Double Unidaptor
Port Size
G1/2 Y15-400-20DD
G3/4 Y15-600-20DD
G1 Y15-800-20DD
G1 1/4 Y15-A00-20DD
G1 1/2 Y15-B00-20DD
Rc1/2 Y15-400-20BB
Rc3/4 Y15-600-20BB
Rc1 Y15-800-20BB
Rc1 1/4 Y15-A00-20BB
Rc1 1/2 Y15-B00-20BB
N.P.T. 1/2 Y15-400-20AA
N.P.T. 3/4 Y15-600-20AA
N.P.T. 1 Y15-800-20AA
N.P.T. 1 1/4 Y15-A00-20AA
N.P.T. 1 1/2 Y15-B00-20AA
50 (1.97)
334 (13.1)*
100 (3.94)
Single Shut-off Unidaptor
Port Size
G1/2 Y15-400-1EDD
G3/4 Y15-600-1EDD
G1 Y15-800-1EDD
G1 1/4 Y15-A00-1EDD
G1 1/2 Y15-B00-1EDD
Rc1/2 Y15-400-1EBB
Rc3/4 Y15-600-1EBB
Rc1 Y15-800-1EBB
Rc1 1/4 Y15-A00-1EBB
Rc1 1/2 Y15-B00-1EBB
N.P.T. 1/2 Y15-400-1EAA
N.P.T. 3/4 Y15-600-1EAA
N.P.T. 1 Y15-800-1EAA
N.P.T. 1 1/4 Y15-A00-1EAA
N.P.T. 1 1/2 Y15-B00-1EAA
51 (2.01)
237 (9.33)**
100 (3.94)
Double Shut-off Unidaptor
Port Size
G1/2 Y15-400-2EDD
G3/4 Y15-600-2EDD
G1 Y15-800-2EDD
G1 1/4 Y15-A00-2EDD
G1 1/2 Y15-B00-2EDD
Rc1/2 Y15-400-2EBB
Rc3/4 Y15-600-2EBB
Rc1 Y15-800-2EBB
Rc1 1/4 Y15-A00-2EBB
Rc1 1/2 Y15-B00-2EBB
N.P.T. 1/2 Y15-400-2EAA
N.P.T. 3/4 Y15-600-2EAA
N.P.T. 1 Y15-800-2EAA
N.P.T. 1 1/4 Y15-A00-2EAA
N.P.T. 1 1/2 Y15-B00-2EAA
51 (2.01)
362 (14.3)**
100 (3.94)
End Connector Kit
Note: Two kits are required per
unidaptor. Each kit contains end
connector, screws, nuts and o-ring.
Port Size
G1/2 5524-58
G3/4 5524-55
G1 5524-52
G1 1/4 5523-52
G1 1/2 5523-93
Rc1/2 5524-57
Rc3/4 5524-54
Rc1 5524-51
Rc1 1/4 5523-51
Rc1 1/2 5523-94
N.P.T. 1/2 5524-56
N.P.T. 3/4 5524-53
N.P.T. 1 5524-50
N.P.T. 1 1/4 5523-50
N.P.T. 1 1/2 5523-95
Mounting Bracket
Brackets slip over end connectors
and are bolted to Unidaptor with
nuts and screws provided.
Note: Each kit contains 6 screws
(2 x 80 mm and 4 x 35 mm) and
4 nuts.
Part Number
G1/2, G3/4, G1 18-001-979
G1 1/4 18-001-978
Yoke Connecting Kit
Comprising seal, screws and nuts.
Part Number 18-026-987
Porting Block
A top take-off porting block may be
fitted to end connectors or shut-off
valves. This can serve several
purposes but is particularly
convienient if instrument or other air
is required to be piped away for
auxilliary use prior to lubricator.
A porting block adds 29 mm (1.14")
to the overall length of a combination
unit.
Part Number 18-026-986
G1/2
G1/4
8/97 N/AL.8.261.700.03
OLYMPIAN SERIES 15 ACCESSORIES
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Pressure Gauges
50 mm Pressure Gauge
R 1/8 Connection
4 bar (60 psig) 18-013-011
10 bar (150 psig) 18-013-013
25 bar (360 psig) 18-013-014
1/8 PTF Connection
4 bar (60 psig) 18-013-202
10 bar (150 psig) 18-013-204
25 bar (360 psig) 18-013-206
Key Lock Bonnet
Part Number 5803-98
Shut-off Valve
Port Size 3 Port/2 Position
G3/4 T15-600-E2AD
G1 T15-800-E2AD
G1 1/4 T15-A00-E2AD
G1 1/2 T15-B00-E2AD
Rc3/4 T15-600-E2AD
Rc1 T15-800-E2AD
Rc1 1/4 T15-A00-E2AD
Rc1 1/2 T15-B00-E2AD
N.P.T. 3/4 T15-600-E2AD
N.P.T. 1 T15-800-E2AD
N.P.T. 1 1/4 T15-A00-E2AD
N.P.T. 1 1/2 T15-B00-E2AD
For optional 2 Port/2 Position (no
exhaust) models substitute ‘
B’
for
E’
at the 7th digit.
e.g. T15-600-
B
2AD.
Silencer
Part Number MB008B (R1)
Treble Unidaptor
Port Size
G1/2 Y15-400-30DD
G3/4 Y15-600-30DD
G1 Y15-800-30DD
G1 1/4 Y15-A00-30DD
G1 1/2 Y15-B00-30DD
Rc1/2 Y15-400-30BB
Rc3/4 Y15-600-30BB
Rc1 Y15-800-30BB
Rc1 1/4 Y15-A00-30BB
Rc1 1/2 Y15-B00-30BB
N.P.T. 1/2 Y15-400-30AA
N.P.T. 3/4 Y15-600-30AA
N.P.T. 1 Y15-800-30AA
N.P.T. 1 1/4 Y15-A00-30AA
N.P.T. 1 1/2 Y15-B00-30AA
50 (1.97)
479 (18.9)
100 (3.94)
Treble Shut-off Unidaptor
Port Size
G1/2 Y15-400-3EDD
G3/4 Y15-600-3EDD
G1 Y15-800-3EDD
G1 1/4 Y15-A00-3EDD
G1 1/2 Y15-B00-3EDD
Rc1/2 Y15-400-3EBB
Rc3/4 Y15-600-3EBB
Rc1 Y15-800-3EBB
Rc1 1/4 Y15-A00-3EBB
Rc1 1/2 Y15-B00-3EBB
N.P.T. 1/2 Y15-400-3EAA
N.P.T. 3/4 Y15-600-3EAA
N.P.T. 1 Y15-800-3EAA
N.P.T. 1 1/4 Y15-A00-3EAA
N.P.T. 1 1/2 Y15-B00-3EAA
51 (2.01)
487 (19.2)**
100 (3.94)
Tamper Resistant Wire
Part Number 2117-01
(pack of 10)
Quick Fill Nipple
Part Number 18-011-021
Liquid Level Switch
Part Number
8 litre: 18-007-975
20 litre: 18-007-974
Remote Fill Kit
Part Number 18-027-980
N/AL.8.261.700.04 8/97
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
OLYMPIAN SERIES 15 ACCESSORIES
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
7/97 N/AL.8.261.925.01
CS15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information
See
Ordering Information
on the following
pages.
ISO Symbol
Automatic Drain
Olympian
Coalescing Exhaust Silencers
3/4
"
, 1
",
1 1/4
"
, 1 1/2
"
Port Sizes
Olympian plug in design
Effectively reduce noise emission of multi valve and
cylinder systems
Remove oil mist and sub-micron particles from
exhaust air
Single or double units for high flow rates
Flow in either direction
Helps to meet noise at work directive
Technical Data
Fluid: Compressed air
Operating temperature*:
Metal bowl: -20° to +50°C (0° to +122°F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2°C
(+35°F).
Materials:
Body: Aluminium
Yoke: Aluminium
Cage: Aluminium
Bowl: Polypropylene
Element: Composite materials
Elastomers: Synthetic rubber
N/AL.8.261.925.02 7/97
Typical Performance Characteristics
CS15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
PRESSURE DR0P vs AIR FLOW
CS15-800
010203040dm
3/s
AIR FLOW
0 20 40 60 80 100 scfm
1 000
900
800
700
600
500
400
300
200
100
0
PRESSURE DROP
mbar g
14
12
10
8
6
4
2
0
psig
SILENCER COMPARED WITH OPEN LINE
CS15-800
Open line
10 100 1 000 10 000
FREQUENCY - Hz
120
100
80
60
SOUND PRESSURE LEVEL - dB
Ordering Information. Models listed include ISO G threads.
For replacement silencer without yoke substitute ‘0’ at the 5th, 8th, 10th and 11th digits eg:CS15-000-0000.
Port Size Single Weight kg (lb) Double Weight kg (lb)
G3/4 CS15-600-10DD 2,34 (5.20) CS15-600-20DD 4,26 (9.47)
G1 CS15-800-10DD 2,29 (5.09) CS15-800-20DD 4,21 (9.36)
G1 1/4 CS15-A00-20DD 4,27 (9.49)
G1 1/2 CS15-B00-20DD 4,28 (9.51)
Alternative Models SC 1 -
50-00
Port Size Substitute
3/4
"
6
1
"
8
1 1/4
"
A
1 1/2
"
B
Option Substitute
Single yoke 1
Double yoke 2
Port Option Substitute
PTF threaded A A
ISO G threaded D D
ISO Rc threaded B B
One main outlet plugged (PTF) A X
One main outlet plugged (ISO G) D X
One main outlet plugged (ISO Rc) B X
Accessories
Wall Mounting Bracket
G3/4 18-001-979
G1 18-001-979
G1 1/4 18-001-978
G1 1/2 N/A
Minimum clearance required to remove bowl.
* 200 mm (7.87) for 1 1/4
"
and 1 1/2
"
models
7/97 N/AL.8.261.925.03
CS15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Dimensions mm (inches)
354 (13.9)†
45 (1.77)
190 (7.48)
50 (1.97)
100 (3.94)
110 (4.33)
330 (13.0)
354 (13.9)†
45 (1.77)
315 (12.4)
50 (1.97)
100 (3.94)
110 (4.33)
330 (13.0)
Single unit Double unit
208 (8.19)*
190 (7.48)*
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
334 (13.1)
315 (12.4)
8,5 (0.33)
100 (3.94) 72 (2.84)
15 (0.59)
50 (1.97)
Bracket Mounting
Use 4 mm (5/32
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Type Part Number
3/4
"
model 18-001-979
Wall Bracket 1
"
model 18-001-979
1 1/4
"
model 18-001-978
1 1/2
"
model N/A
N/AL.8.261.925.04 7/97
CS15
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Part Number
Service kit CS15RK
Replacement elements 5576-97
Service kit includes: bowl, drain plug and drain retainer.