(7/22)
• All specifications are subject to change without notice.
001-02 / 20110925 / e531_vls
Inductors for Power Circuits
Wound/STD • Magnetic Shielded
VLS Series VLS2012E
FEATURES
• Miniature size
Mount area: 2×2mm
Height: 1.2mm max.
• Generic use for portable DC to DC converter line.
• High magnetic shield construction should actualize high
resolution for EMC protection.
• Available for automatic mounting in tape and real package.
• The products do not contain lead and support lead-free
soldering.
APPLICATIONS
Cellular phones, DVCs, DSCs, PDAs, LCD displays, HDDs, etc.
SHAPES AND DIMENSIONS
RECOMMENDED PC BOARD PATTERN
ELECTRICAL CHARACTERISTICS
∗Rated current: Value obtained when current flows and the temperature has risen to 40°C or when DC current flows and the nominal value of inductance
has fallen by 30%, whichever is smaller.
• Operating temperature range: –40 to +105°C (Including self-temperature rise)
TYPICAL ELECTRICAL CHARACTERISTICS
INDUCTANCE vs. DC SUPERPOSITION CHARACTERISTICS
VLS2012ET-R47N VLS2012ET-R68N
Conformity to RoHS Directive
2.0±0.1
2.0±0.1
1.2max.
Dimensions in mm
0.65
0.7
0.65
2.0
Dimensions in mm
Part No. Inductance
(µH)
Inductance
tolerance
(%)
Test frequency
(MHz)
DC resistance
(Ω)
Rated current(A)∗
Based on inductance change Based on
temperature rise
typ.
max. typ. max. typ.
VLS2012ET-R47N 0.47 ±30 1.0 0.059 0.049 2.05 2.25 2.00
VLS2012ET-R68N 0.68 ±30 1.0 0.066 0.055 1.70 1.90 1.85
VLS2012ET-1R0N 1.0 ±30 1.0 0.086 0.071 1.45 1.65 1.65
VLS2012ET-1R5N 1.5 ±30 1.0 0.108 0.090 1.20 1.30 1.45
VLS2012ET-2R2M 2.2 ±20 1.0 0.153 0.127 1.00 1.10 1.25
VLS2012ET-3R3M 3.3 ±20 1.0 0.228 0.190 0.84 0.93 1.00
VLS2012ET-4R7M 4.7 ±20 1.0 0.336 0.280 0.70 0.78 0.84
VLS2012ET-6R8M 6.8 ±20 1.0 0.498 0.415 0.57 0.64 0.69
VLS2012ET-100M 10 ±20 1.0 0.834 0.695 0.47 0.52 0.53
VLS2012ET-150M 15 ±20 1.0 1.062 0.885 0.40 0.44 0.47
VLS2012ET-220M 22 ±20 1.0 1.764 1.470 0.33 0.37 0.35
0.0
0.3
0.2
0.1
0.4
0.6
0.5
0 1.510.5 2
Inductance(µH)
DC current(A)
0.0
0.3
0.2
0.1
0.4
0.8
0.5
0.6
0.7
0 1.510.5 2
Inductance(µH)
DC current(A)
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.