HALOGEN HF FREE MLP1 ESD Suppressor PolySurgTM 0402ESDA-MLP1 Pb Applications The Cooper Bussmann PolySurgTM 0402ESDA-MLP1 ESD Suppressors protect valuable high-speed data circuits from ESD damage without distorting data signals as a result of its ultra-low (0.05pF typical) capacitance. * Computers and peripherals * HDTV Equipment * DVD Players * A/V Equipment * Satellite radio * Cell phones * PDAs * Digital still cameras * Digital camcorders * MP3/Multimedia players * Set top boxes * External storage * DSL Modems * High speed data ports * USB 2.0/3.0 * IEEE 1394b * HDMI 1.3 * DVI * High speed ethernet * Infiniband(R) Features Part Numbering System: 0402 Surface Mount Device Description * * * * * * * * * Halogen free RoHS compliant for global applications Lead free Ultra-low capacitance (0.05pF typ.) ideal for high speed data applications Provides ESD protection with fast response time (<1ns) allowing equipment to pass IEC 61000-4-2 level 4 test Single-line, bi-directional device for placement flexibility Low profile 0402/1005 design for board space savings Low leakage current (<0.1nA typ.) reduces power consumption (Sn) Tin-plated version available ESDA MLP 1 Package Size Product Family Form Designation Designation for Dip Termination Packaging * 10,000 suppressors on paper tape in seven inch (178mm) plastic reel per EIA Standard 481-1. Ordering Information Catalog Number Description 0402ESDA-MLP1 10,000 pieces on paper tape on 7" (178mm) reel - tin plating Specifications Characteristic Rated Voltage Clamping Voltage1 Trigger Voltage2 Capacitance (@1MHz) Attenuation Change (0-6GHz) Leakage Current (@12Vdc) ESD Capability * IEC61000-4-2 Direct Discharge * IEC61000-4-2 Air Discharge ESD Pulse Withstand3 Value 30Vdc maximum 35V typical 300V typical 0.05pF typical, 0.15pF maximum -0.2dB typical <0.1nA typical Design Considerations The location in the circuit for the MLP series has to be carefully determined. For better performance, the device should be placed as close to the signal input as possible and ahead of any other component. Due to the high current associated with an ESD event, it is recommended to use a "0-stub" pad design (pad directly on the signal/data line and second pad directly on common ground). 8kV typical 15kV typical >1000 typical 1 Per IEC61000-4-2, Level 4 waveform (8kV direct, 30A) measured 30ns after initiation of pulse. 2 Trigger measurement made using Transmission Line Pulse (TLP) method. 3 Minor shifting in characteristics may be observed over multiple ESD pulses at very rapid rate 1010 BU-SB101153 Page 1 of 2 Data Sheet 4367 Environmental Specifications Characteristic Load Humidity Dimensions - in (mm) Value 12Vdc per EIA/IS-772 Para. 4.4.2, +85C, 85% RH for 1000 hours EIA/IS-722 Para 4.6, Air-to-Air -55C to +125C, 5 cycles MIL-STD-202G Method 106G, 10 cycles EIA/IS-722 Para. 4.9 EIA/IS-722 Para. 4.10 EIA/IS-722 Para. 4.11 -55C to +125C -55C to +125C Thermal Shock Moisture Resistance Test Mechanical Shock Vibration Resistance to Solvent Operating Temperature Range Storage Temperature Range 0.021 0.003 (0.530 0.076) 0.010 0.004 (0.250 0.100) 0.043 0.004 (1.100 0.100) 0.014 0.003 (0.360 0.076) Soldering Recommendations Temperature (C) * Compatible with lead and lead-free solder reflow processes * Peak reflow temperatures and durations: - IR Reflow = 260C max for 10 sec. max. - Wave Solder = 260C max. for 10 sec. max. * Recommended IR Reflow Profile: Tape and Reel Specifications - mm Time (seconds) Recommended Pad Layout - in (mm) 0.087 (2.20) 0.028 (0.70) A B D E1 0.75 1.25 1.50 1.75 Carrier Dimensions E2 F G P1 6.25 3.50 0.75 4.00 P2 P3 T W 2.00 4.00 0.43 8.00 0.05 0.05 0.10 0.10 0.30 0.05 min. 0.10 0.05 0.05 0.05 0.20 10,000 pieces in paper tape on 7 inch (178mm) plastic reel per EIA Standard 481-1 0.016 (0.40) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. (c) 2010 Cooper Bussmann www.cooperbussmann.com 1010 BU-SB101153 Page 2 of 2 Data Sheet 4367