LBR106 thru LBR110 REVERSE VOLTAGE - 600 to 1000 Volts FORWARD CURRENT - 1.0 Ampere LEADLESS SURFACE MOUNT BRIDGE RECTIFIER LBR FEATURES * Low profile package - 1.00mm * Low power loss & high efficiency * High current capability MECHANICAL DATA * Case: Packed with FRP substrate and epoxy underfilled * Case Material: "Green" molding compound, UL flammability classification 94V-0, (No Br. Sb. Cl.) Moisture Sensitivity: Level 1 per J-STD-020C * * Terminals: Lead Free Plating, solder per J-STD-002 and Dim. Min. Max. A 5.20 5.40 B 4.10 4.30 C 5.70 5.90 D 1.00 1.20 E 0.85 0.95 0.86 1.16 F All dimensions in millimeter JESD22-B102 Component in accordance to RoHs 2002/95/EC * * ESD performance - 4000V human body model (JESD22-A114) -400V machine model (JESD22-A115) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25C ambient temperature unless otherwise specified. PARAMETER SYMBOL LBR106 LBR108 LBR110 UNIT Device marking code Note 106 108 110 --- Maximum Repetitive Peak Reverse Voltage VRRM 600 800 1000 V Maximum RMS Voltage VRMS 420 560 700 V Maximum DC Blocking Voltage VDC 600 800 1000 V Average Rectified Output Current @TA=55C Peak Forward Surge Current 8.3ms single half sine-wave Operating junction temperature range Storage temperature range PARAMETER TEST CONDITIONS I(AV) 1.0 A IFSM 30 A TJ -55 to +175 C TSTG -55 to +175 C SYMBOL Max. UNIT Forward Voltage (1) IF=1.0A Tj=25C VF 1.0 V Leakage Current (1) VR=VDC Tj=25C Tj=125C IR 5.0 500 uA SYMBOL Typical UNIT CJ 25 pF Typical thermal resistance _ Junction to Case (3) RJC 50 C/W Typical thermal resistance _ Junction to Ambient (3) RJA 100 C/W Typical thermal resistance _ Junction to Lead (3) RJL 15 C/W THERMAL CHARACTERISTIC Typical junction capacitance (2) Note : REV. 1, Sep-2010, KBDB03 (1) (2) (3) 300us Pulse width, 2% Duty cycle. Measured at 1.0MHz and applied reverse voltage of 4.0V DC. Thermal Resistance test performed in accordance with JESD-51. Unit mounted on PC board with 5.0mm2 (0.03mm thick) land areas. RJL is measured at the lead of cathode band, RJC is measured at the top centre of body. RATING AND CHARACTERISTIC CURVES LBR106 thru LBR110 FIG.1- FORWARD CURRENT DERATING CURVE FIG.2- MAXIMUM NON-REPETITIVE SURGE CURRENT 35 PEAK FORWARD SURGE CURRENT, (A) A VERAGE FORWARD CURRENT, (A) 1.2 30 1 25 0.8 20 0.6 15 0.4 10 60Hz resistive or inductive load 0.2 8.3ms Single Half-Wave 5 0 0 0 25 50 75 100 125 150 1 175 FIG.3- TYPICAL FORWORD CHARACTERISTICS FIG.4- TYPICAL JUNCTION CAPACITANCE CAP ACI TANCE, (pF) INSTANTANEOUS FORWARD CURRENT, (A) 100 100 10 1 0.1 10 Tj=25C Tj=25C, f=1MHz 0.01 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 INSTANTANEOUS FORWARD VOLTAGE, (V) FIG.5- TYPICAL REVERS E CHARACTERISTICS Tj=100C 1 0.1 Tj=25C 0.01 0 20 40 60 80 100 PERCENT OF RATED PEAK REVERSE VOLTAGE, (V) 0.1 1 10 REVERSE VOLTAGE, (V) 10 INSTANTANEOUS REVERSE CURRENT, (uA) 10 NUMBER OF CYCLES AT 60Hz AMBIENT TEMPERATURE, () 120 100 Mechanics drawing LBR106 thru LBR110 Fig.6 Recommended Foot Print of LBR Marking: LBR=Series code 1=1.0A 06=600V 08=800V 10=1000V Y=Last digit of the year WW=Mfg. week O Legal Disclaimer Notice LBR106 thru LBR110 Important Notice and Disclaimer LSC reserves the right to make changes to this document and its products and specifications at any time without notice. Customers should obtain and confirm the latest product information and specifications before final design, purchase or use. LSC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does LSC assume any liability for application assistance or customer product design. LSC does not warrant or accept any liability with products which are purchased or used for any unintended or unauthorized application. No license is granted by implication or otherwise under any intellectual property rights of LSC. LSC products are not authorized for use as critical components in life support devices or systems without express written approval of LSC.