4-35
Absolute Maximum Ratings
For ratings of individual members of a series, see Device Ratings and Specifications chart.
ZA SERIES UNITS
Continuous:
Steady State Applied Voltage:
AC Voltage Range (V
M(AC)RMS
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Voltage Range (V
M(DC)
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 to 460
5.5 to 615
V
V
Transient:
Peak Pulse Current (I
TM
)
For 8/20
µ
s Current Wave (See Figure 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Pulse Energy Range (Note 1)
For 10/1000
µ
s Current Wave (W
TM
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50 to 6500
0.1 to 52
A
J
Operating Ambient Temperature Range (T
A
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 85
o
C
Storage Temperature Range (T
STG
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 125
o
C
Temperature Coefficient (
α
V) of Clamping Voltage (V
C
) at Specified Test Current . . . . . . . . . . . . . . . . . <0.01 %/
o
C
Hi-Pot Encapsulation (Isolation Voltage Capability) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
(Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) . . . .
Insulation Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 M
Ω
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied..
Device Ratings and Specifications
(Note 1)
VDE Certified. License Number 116895E
ZA Series Varistors are listed under UL File No. E135010 as a UL recognized component.
PART
NUMBER
MODEL
SIZE
DISC
DIA. (mm) BRAND
MAXIMUM RATING (85
o
C) SPECIFICATIONS (25
o
C)
CONTINUOUS TRANSIENT
VARISTOR VOLT-
AGE AT 1mA DC
TEST CURRENT
MAXIMUM
CLAMPING
VOLTAGE
8 x 20
µ
s
TYPICAL
CAPACI-
TANCE
f = 1MHzV
RMS
V
DC
ENERGY 10
x 1000
µ
s
PEAK
CURRENT
8 x 20
µ
s
V
M(AC)
V
M(DC)
W
TM
I
TM
V
NOM
MIN
V
NOM
MAX V
C
I
PK
C
(V) (V) (J) (A) (V) (V) (A) (pF)
V8ZA05 5 Z08 4 5.5 0.1 50 6 11 30 1 1400
V8ZA1 7 08Z1 4 5.5 0.4 100 6 11 22 2.5 3000
V8ZA2 10 08Z2 4 5.5 0.8 250 6 11 20 5 7500
V12ZA05 5 Z12 6 8 0.14 50 9 16 37 1 1200
V12ZA1 7 12Z1 6 8 0.6 100 9 16 34 2.5 2500
V12ZA2 10 12Z2 6 8 1.2 250 9 16 30 5 6000
V18ZA05 5 Z18 10 14 0.17 100 14.4 21.6 36 1 1000
V18ZA1 7 18Z1 10 14 0.8 250 14.4 21.6 36 2.5 2000
V18ZA2 10 18Z2 10 14 1.5 500 14.4 21.6 36 5 5000
V18ZA3 14 18Z3 10 14 3.5 1000 14.4 21.6 36 10 11000
V18ZA40 20 18Z40 10 14 80 (Note 2) 2000 14.4
(Note 3)
21.6 37 20 22000
V22ZA05 5 Z22 14 18 0.2 100 18.7 26 43 1 800
V22ZA1 7 22Z1 14 18 0.9 250 18.7 26 43 2.5 1600
V22ZA2 10 22Z2 14 18 2 500 18.7 26 43 5 4000
V22ZA3 14 22Z3 14 18 4 1000 18.7 26 43 10 9000
V24ZA50 20 24Z50 14 18
(Note 4)
100 (Note 2) 2000 19.2
(Note 3)
26 43 20 18000
V27ZA05 5 Z27 17 22 0.25 100 23 31.1 53 1 600
V27ZA1 7 27Z1 17 22 1 250 23 31.1 53 2.5 1300
V27ZA2 10 27Z2 17 22 2.5 500 23 31.1 53 5 3000
V27ZA4 14 27Z4 17 22 5 1000 23 31.1 53 10 7000
V27ZA60 20 27Z60 17 22 120 (Note 2) 2000 23
(Note 3)
31.1 50 20 13000
ZA Series