INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R03
PLB190
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC (Unless Otherwise Noted)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Blocking Voltage 400 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output (60 sec.) 5000 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current (Continuous)
AC/DC Configuration IF=0mA IL
- - 130 mArms / mADC
DC Configuration - - 250 mADC
Peak Load Current t=10ms ILPK - - ±400 mAP
On-Resistance 1
AC/DC Configuration IF=0mA, IL=130mA RON
--25
DC Configuration IF=0mA, IL=250mA - - 10
Off-State Leakage Current IF=2mA, VL=400VPILEAK -- 1 A
Switching Speeds
Turn-On IF=5 mA, VL=10V ton -- 1 ms
Turn-Off toff - - 2.5
Output Capacitance IF=5mA, VL=50V, f=1MHz COUT -11 - pF
Input Characteristics
Input Control Current to Activate2IL=130mA IF- 0.38 2 mA
Input Control Current to Deactivate - IF0.2 0.35 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3 - pF
1 Measurement taken within 1 second of on-time.
2 For high temperature operation (>60ºC), a LED current of 4mA is recommended.