R SRPs- 1p5-0105 0s e0r i e ss e r i e s 1 5 0 0 W S i n g l e O utput Power Supply 1500WSingleOutputPowerSupply SPECIFICATION MODEL OUTPUT RSP-1500-5 RSP-1500-12 RSP-1500-15 RSP-1500-24 RSP-1500-27 RSP-1500-48 DCVOLTAGE 5V 12V 15V 24V 27V 48V RATEDCURRENT 240A 125A 100A 63A 56A 32A CURRENTRANGE 0~240A 0~125A 0~100A 0~63A 0~56A 0~32A RATEDPOWER 1200W 1500W 1500W 1512W 1512W 1536W RIPPLE&NOISE(max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ.RANGE 10~13.5V 13.5~16.5V 20~26.4V VOLTAGETOLERANCE Note.3 INPUT 4.5~5.5V 2.0% 24~30V 43~56V 1.0% 1.0% 1.0% 1.0% 1.0% LINEREGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOADREGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP,RISETIME 1500ms,100msatfullload HOLDTIME (Typ.) 10msatfullload VOLTAGERANGE 90~264VAC127~370VDC FREQUENCY RANGE 47~63Hz POWERFACTOR (Typ.) 0.95/230VAC0.98/115VACatfullload 14msatfullload 87% EFFICIENCY (Typ.) 80% ACCURRENT (Typ.) INRUSHCURRENT (Typ.) 17A/115VAC8A/230VAC 30A/115VAC60A/230VAC LEAKAGECURRENT <2.0mA /240VAC 87% 16msatfullload 90% 90% 91% 105~135% ratedoutputpower OVERLOAD Note.5 PROTECTION OVERVOLTAGE OVERTEMPERATURE Protectiontype:Constantcurrentlimitingunitwillshutdowno/pvoltageafter5sec.Re-powerontorecover 5.75~6.75V 13.8~16.8V 17~20.5V 27.6~32.4V 31~36.5V AUXILIARY POWER(AUX) Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown 12A@0.1A(OnlyforRemoteON/OFFcontrol) REMOTEON/OFFCONTROL PleaseseetheFunctionManual FUNCTION ALARMSIGNAL OUTPUT OUTPUTVOLTAGETRIM PleaseseetheFunctionManual PleaseseetheFunctionManual CURRENTSHARING PleaseseetheFunctionManual WORKINGTEMP. -20~+70 WORKINGHUMIDITY ENVIRONMENT STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTANDVOLTAGE 57.6~67.2V Protectiontype:Shutdowno/pvoltage,re-powerontorecover 95 5 (TSW2)Detectonheatsinkofpowertransistor (Refertooutputloadderatingcurve) 20~90%RHnon-condensing -40~+85 ,10~95%RH 0.05%/ (0~50 ) 10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes UL60950-1, TUVEN60950-1 Approved I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC SAFETY & ISOLATIONRESISTANCE EMICONDUCTION&RADIATION CompliancetoEN55022(CISPR22) EMC (Note4) HARMONICCURRENT Complianceto EN61000-3-2,-3 EMSIMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,Lightindustrylevel,criteria A 62.6Khrsmin.MIL-HDBK-217F(25 278*127*83.5mm(L*W*H) 2.6Kg;6pcs/16.6Kg/1.75CUFT ) FileName:RSP-1500-SPEC2005-08-16 WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 RRSsPp- -11550000s esrei er ise s 1 5 0 0 W S i n g l e O1500WSingleOutputPowerSupply utput Power Supply MechanicalSpecification CaseNo.943A Unit:mm 11.2 22.7 240 4-M4L=5 16 83.5 38.1 38 278 11.2 240 4 17.5 OUTPUT +V 4-M4L=5 -V CN1 CN2 CN3 86 42 86 42 64 2 75 31 75 31 53 1 I/P LED 93 127 1 SVR 10 Airflow direction 13 2 3 ACInput TerminalPin.No. Assignment PinNo. 1 2 3 ControlPin.No Assignment(CN1,CN2): PinNo. Assignment FG AC/N AC/L 1 2 3,5,7 Assignment RCG RC2 -S PinNo. 4 6 8 Terminal Assignment MatingHousing TRIM HRSDF11 HRSDF11 LS(CurrentShare) orequivalent orequivalent +S RCG:RemoteON/OFFGround TRIM: AdjustmentofOutputVoltage RC2: RemoteON/OFFLS:LoadShare -S:-RemoteSensing+S:+RemoteSensing ControlPin.No Assignment(CN3): PinNo. 1 2 3 Assignment P OKGND P OK RCG PinNo. 4 5 6 P OKGND:PowerOKGround P OK:PowerOKSignal RCG:RemoteON/OFFGround Terminal Assignment MatingHousing AUXG HRSDF11 HRSDF11 RC1 orequivalent orequivalent AUX AUXG: AuxiliaryGround RC1:RemoteON/OFF AUX: AuxiliaryOutput PFCfosc:70KHz PWMfosc:100KHz BlockDiagram +S I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC POWER SWITCHING RECTIFIERS & FILTER +V -V -S PFC CONTROL O.T.P. O.V.P. O.L.P. PWM CONTROL LOAD SHARING AUX POWER DETECTION CIRCUIT P OK REMOTE CONTROL RC LS FAN RECTIFIERS & FILTER AUXPOWER (12V/0.1A) FileName:RSP-1500-SPEC2005-08-16 WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 RRSsPp--11550000 1 5 0 0 W S i n g l e 1500WSingleOutputPowerSupply O utput Power Supply DeratingCurve sseerriieess StaticCharacteristics Ta=25 100 Others +12V,+15V 80 100 90 50 +5V LOAD(%) LOAD(%) 60 40 20 -20 80 70 60 0 10 20 30 40 45 50 AMBIENTTEMPERATURE( 60 70 90 100 120 140 150 160 180 200 220 240 264 INPUTVOLTAGE(V)60Hz ) FunctionManual 1.RemoteON/OFF (1)RemoteON/OFFcontrolbecomesavailablebyapplyingvoltageinCN1&CN2&CN3 (2)Table1.1showsthespecificationofRemoteON/OFFfunction (3)Fig.1.2showstheexampletoconnectRemoteON/OFFcontrolfunction Table1.1SpecificationofRemoteON/OFF Fig.1.2(A) ConnectionMethod Outputon SWOpen SWLogic Outputoff SWClose Fig.1.2(B) SWOpen SWClose Fig.1.2(C) SWClose SWOpen Fig.1.2ExamplesofconnectingremoteON/OFF (A)Usingexternalvoltagesource (B)Usinginternal12Vauxiliaryoutput AUX AUX 2.2K 2.2K RC1 150 12Vtyp. 5V 150 RC2 12Vtyp. 620 RCG RC1 RC2 SW RCG SW AUXG AUXG (C)Usinginternal12Vauxiliaryoutput AUX 2.2K 150 12Vtyp. RC1 RC2 SW RCG AUXG WWW.ASTRODYNE.COM 300 Myles StandishFileName:RSP-1500-SPEC2005-08-16 Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 RRSsPp--11550000 1500WSingleOutputPowerSupply 1 5 0 0 W S i n g l e O utput Power Supply 2.AlarmSignalOutput (1)Alarmsignalissentoutthrough"P OK"&"P OKGND"pins (2)Anexternalvoltagesourceisrequiredforthisfunction. Themaximumappliedvoltage is50Vandthemaximumsinkcurrentis10mA (3)Table2.1explainthealarmfunctionbuilt-inthepowersupply Function Description Outputofalarm(P OK) Thesignalis"Low"whenthepowersupplyis above Low 65%oftheratedoutputvoltage-PowerOK (0.5Vmaxat10mA) P OK Highoropen Thesignalturnstobe"High"whenthepowersupply (Externalappliedvoltage isunder65%oftheratedoutputvoltage-PowerFail 10mA max.) sseerriieess P OK R 0.1uF 100K V P OKGND ExternalvoltageandR (Themax.Sinkis10mA and50V) Fig.2.2InternalcircuitofP OK(Opencollectormethod) Table2.1Explanationofalarm 3.OutputVoltageTRIM (1)Adjustmentofoutputvoltageispossiblebetween70~100%(Typ.)oftheratedoutputwhichisshowninFig.3.1 (2)Connectingaresistorexternallybetween TRIMand-SonCN1orCN2thatisshowninFig.3.2. Vout 100% CN1 90% TRIM R(0.5W) or 80% CN2 -S 70% R Fig.3.2Outputvoltagetrimming 0 470 1.8K OPEN Fig.3.1ExternalResistor(Typical) 4.CurrentSharing (1)Paralleloperationisavailablebyconnectingtheunitsshownasbelow (+S,-SandLSareconnectedmutuallyinparallel): (2)Thevoltagedifferenceamongeachoutputshouldbeminimizedthatlessthan 2%isrequired (3)Thetotaloutputcurrentmustnotexceedthevaluedeterminedbythefollowingequation (Outputcurrentatparalleloperation)=(Theratedcurrentperunit)x(Numberofunit)x0.9 (4)Inparalleloperation4unitsisthemaximum,pleaseconsultthemanufactureforother applications (5)Whenremotesensingisusedinparalleloperation,thesensingwiremustbeconnectedonly tothemasterunit No.1(Master) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N No.2(Slave) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N +S No.3(Slave) V+ +S -S CN1 LS -S +V -V Load V+S -S CN2 LS AC/L AC/N No.4(Slave) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N WWW.ASTRODYNE.COM 300 Myles StandishFileName:RSP-1500-SPEC2005-08-16 Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181