SPECIFICATION
150W Single Output Switching Power Supply LRS-150 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION Note.4
LOAD REGULATION
Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT (Typ.)
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
40ms/230VAC 35ms/115VAC at full load
85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)
47 ~ 63Hz
2.8A/115VAC 1.6A/230VAC
COLD STAR 60A/230VAC
<0.75mA / 240VAC
110 ~ 140% rated output power
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-30 ~ +70℃(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
601K hrs min. MIL-HDBK-217F (25 )℃
0.48Kg ; 30pcs/15.4Kg/0.75CUFT
159*97*30mm (L*W*H)
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
PROTECTION
ENVIRONMENT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SAFETY STANDARDS UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1 ,CCC GB4943 approved/- -216
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
SAFETY &
EMC
(Note 7)
EMC IMMUNITY
EMC EMISSION
OVER TEMPERATURE
87.5% 88.5% 89% 90%
12V 15V 24V 48V
12.5A 10A 6.5A 3.3A
0 ~ 12.5A 0 ~ 10A 0 ~ 6.5A 0 ~ 3.3A
150W 150W 156W 158.4W
150mVp-p 150mVp-p 200mVp-p 200mVp-p
±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5%
89%
36V
4.3A
0 ~ 4.3A
154.8W
200mVp-p
±1.0%
±0.5%
±0.5%
13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 43.2 ~ 52.8V
32.4 ~ 39.6V
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power
supplies. (as available on http://www.meanwell.com)
8. The ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m (6500ft).℃
LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-36 LRS-150-48
File Name:LRS-150-SPEC 2015-06-25