MW MEAN WELL 150W Single Output Switching Power Supply RS-1 50 series @ Features : * Protections: Short circuit / Overload / Over voltage * Cooling by free air convection * LED indicator for power on * 100% full load burn-in test All using 105C long life electrolytic capacitors Withstand 300VAC surge input for 5 second * High operating temperature up to 70C Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty CB IAICE SPECIFICATION coven 368-1 1EC62368-1 TPTCO04 MODEL RS-150-3.3 RS-150-5 RS-150-12 RS-150-15 RS-150-24 RS-150-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 30A 26A 12.5A 10A 6.5A 3.3A CURRENT RANGE 0~30A 0~26A 0~12.5A 0~10A 0~6.5A 0~3.3A RATED POWER 99W 130W 150W 150W 156W 158.4W RIPPLE & NOISE (max.) Note.2| 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p OUTPUT | VOLTAGE ADJ. RANGE 3.2V ~ 3.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 14.25 ~ 16.5V 22.8 ~ 26.4V 45.6 ~52.8V VOLTAGE TOLERANCE Note.3| +3.0% +2.0% +1.0% +1.0% +1.0% +1.0% LINE REGULATION Note.4] +0.5% +0.5% +0.5% +0.5% +0.5% +0.5% LOAD REGULATION _ Note.5| +2.0% +1.0% +0.5% +0.5% +0.5% +0.5% SETUP, RISE TIME 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 28ms/230VAC 20ms/115VAC at full load VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY(Typ.) 74% 78% 83% | 84% 86% 86% AC CURRENT (Typ.) 3A/115VAC 2A/230VAC INRUSH CURRENT (Typ.) COLD START 40A/230VAC LEAKAGE CURRENT <2mA/ 240VAC 110 ~ 150% rated output power PROTECTION OVERLOAD Note.8 Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V | 5.75 ~6.75V | 13.8 ~ 16.2V [ 17.25~20.25V | 27.6~32.4V 55.2 ~ 64.8V eerie Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -25 ~ +70C (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/C (0 ~ 50C) VIBRATION 10 ~ 500Hz, 5G 10min./cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV EN62368-1, EAC TP TC 004 approved SAFETY 8 | WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC EMC ISOLATION RESISTANCE \/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25C/ 70% RH (Note 6) EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteriaA, EAC TP TC 020 MTBF 244KHrs min. | MIL-HDBK-217F (25C) OTHERS /|DIMENSION 199*98*38mm (L*W*H) PACKING 0.7Kg; 20pcs/14Kg/0.8CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. . Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. . Tolerance : includes set up tolerance, line regulation and load regulation. . Load regulation is measured from 0% to 100% rated load. 2 3 4. Line regulation is measured from low line to high line at rated load. 5 6 . The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http:/Avww.meanwell.com) N . Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 8. Extra consideration should be taken when selecting output wiring for 3.3V and 5V models. This is to prevent the protection modes for overload and short circuit from becoming constant power. 9. The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft) File Name:RS-150-SPEC 2019-07-11MW 150W Single Output Switching Power Supply RS-1 50 series MEAN WELL i Mechanical Specification Case No.902A Unit:mm 197 | SSS +j>>>>>5>5>5>55>55-755- 55 550 5 I se | Jae i (e + O9 e rt Taall, 3 HEA st E | 2 | | m1 Laat | ha | LS | 4 3 e| [1 6! 5 HS N ah ! yy? ey v4 L Kn ) _ W WH o@ Kz ! BH t ie ut 45.| | 57.5 | 120 199 6.5. 190 | | D D> 2 Terminal Pin No. Assignment Xe = 3 Pin No. | Assignment | Pin No. Assignment oe 1 pg | =| j.|8 1 ACIL 4,5 | DCOUTPUT-V = = = g 2 ACIN 67 | DCOUTPUT+V co co co a 3 FG + [22 157 Block Diagram 230 115 fosc : 60KHz EMI RECTIFIERS POWER 3 RECTIFIERS 0 4V IP oO & | & FILTER : . FILTER SWITCHING FILTER ] ov x DETECTION FG LE | Ae % CIRCUIT CONTROL mL] x see O.V.P. Hi Derating Curve Hi Static Characteristics +00 | 100 + Others 90 F | 80 4 ! 80 + + 60 1 70 4 ~ | sf | Ss r 7 = 40 | x < ! < 50 | | =_l 4 20 ! - 40 |. | 1 | VERTICAL 1 1 1 1 1 1 1 1 1 1 2 0 1 422 3 440 #4250 460 70 88 95 400 145 120 439 2 0 HORIZONTAL) 176 190 200 230 240 264 AMBIENT TEMPERATURE (C) INPUT VOLTAGE (VAC) 60Hz File Name:RS-150-SPEC 2019-07-11