FP Impulse Heat Controller
Ultra-Quick
Heat Up Maintains steady temperature Quick Cool Down
Ultra- Quick
Temperature
Control!
Impulse Heat Controller Example
Using timers to control sealing Impulse heat controller sealing
Features
Beautiful
Finish!
Ultra high-speed 18ms! Suitable for high-speed temperature
control needed for impulse sealers and vacuum packing machines.
Extend the lifetime of your heater
The temperature will not rise higher than needed. This will extend the
lifetime of the heater in comparison to heat control using timers.
Can be used as a PLC
Perform I/O control, save temperature data, and even connect to an HMI.
©2006 Panasonic Electric Works Corp. of America
Panasonic Electric Works Corporation of America
FAX (908) 464-8714 PHONE (908) 464-3550  WEB http://pewa.panasonic.com/acsd/
Phase Detecting Unit Impulse Heat Controller
Dimensions (mm)
Instructions for Use
Connection Diagram
Specications Part Numbers
Impulse Heat Controller
Item
Temp. Input Conversion Time
Temp. Input Range
Temp. Control Input
Temp. Sensor Type
Control Inputs
Control Outputs
Rated Voltage
18ms
30 600°C
1 Input
K-Type Thermocouple
8 Inputs
6 Outputs
24V DC
Impulse Heat Controller
 
AAD010100
 
AAD02010
Impulse Heat Controller Phase Detecting Unit
44.5
48 7.5 70
RUN
PROG.
PROG. RUN
h
F
ms
C
NS
R
LOCK
PV
SV
RUN
PROG.
ERR
AL ARM
I
135
240
SET
MODE
12
25.0
V 0
IN
I 0
COM
COM
OUT
V 1
I 1
V
I
60.0
90.0
10
Using Thermocouples
Isolate from heater using insulating tape.
If you need a quick response from the thermocouple, use a thin
thermocouple and thin insulating tape.
About SSR
Please use non-zero
cross-type SSR. Also, please
select SSR according to load
voltage and current, using a
radiator if necessary
Solid State Relay
( Non-Zero Cross )
Impulse Heat
Controller
OUT+
OUT
-
ACIN
ACIN
NC
NC
FE
Phase Detecting Unit input100-240VAC
24 VDC
24 VDC
ACIN
Zero-Point
Signal
Indicates
Connection
Load Current
10A
15A
20A
25A
40A
Part Number
AQN121
AQN221
AQN321
AQN421
AQN621
SSR Part Number
Power
Connector
Output
Connector
Input
Connector
Phase Detecting Unit
LED types add “L at the end of the part
number. For Varistor, add “V at the end
of the part number.
Specications Product NameProduct Name Part Number
To run the Impulse Heat Controller and to program
it, additional software is required. Please contact us
for more information.
©2006 Panasonic Electric Works Corp. of America
Panasonic Electric Works Corporation of America
FAX (908) 464-8714 PHONE (908) 464-3550  WEB http://pewa.panasonic.com/acsd/
+
-
Start Autotuning
Start PID
Zero Hold Signal
K-Type
Thermocouple
+
-
X2
COM
X0
X1
X4
A1+
A1-
Y0
+
-
+
-