Vectron International · www.vectron.com v.2006-11-10 · page 1 of 5
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
C4550 OCXO
Typical Applications Features
Base Stations Surface Mount Package Optional
Test Equipment Reflow Process Compatible Optional
Synthesizers AT-Cut and SC-Cut Crystal Options
Digital Switching Low Profile Compact Package
Previous Vectron Model Numbers 4853, 4853S, 4597, 4597S,
4859, 4859S, 4877, 4877S, OCO500, OC-260
Frequency range 10 MHz – 100 MHz
Standard frequencies 10; 12.8;13; 16.384;20; 32.768MHz; 100Mhz
Frequency stabilities1 [AT Cut Crystal – Standard]
Parameter Min Typ Max. Units Operating temp range
Ordering Code
vs. operating temperature range -50 +50 ppb 0 … +70°C C508
(Referenced to +25°C) -100 +100 ppb -20 … +70°C D107
-150 +150 ppb -40 … +70°C E157
-200 +200 ppb -40 … +85°C F207
Parameter Min Typ Max. Units Condition
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following Years)
-300
-10
-10
-2.0
-500
-250
+300
+10
+10
+2.0
+500
+250
ppb
ppb
ppb
ppb
ppb
ppb
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
Warm-up Time 3 minutes to ± 100ppb of final frequency (1 hour reading) @
+25°C
Frequency stabilities1 [SC Cut Crystal – Option]
Parameter Min Typ Max. Units Operating temp range
Ordering Code
vs. operating temperature range -10 +10 ppb 0 … +70°C C108
(Referenced to +25°C) -20 +20 ppb -20 … +70°C D208
-25 +25 ppb -40 … +70°C E258
-30 +30 ppb -40 … +85°C F308
Parameter Min Typ Max. Units Condition
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following Years)
-100
-5.0
-5.0
-1.0
-100
-50
+100
+5.0
+5.0
+1.0
+100
+50
ppb
ppb
ppb
ppb
ppb
ppb
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
Warm-up Time 3 minutes to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter Min Typ Max. Units Condition Ordering Code
Supply voltage [Standard] 4.75 5 5.25 VDC SV050
Supply voltage [Option] 11.4 12.0 12.6 VDC SV120
Supply voltage [Option] 3.135 3.3 3.465 VDC SV033
Power consumption 3.0 Watts during warm-up
1.0 Watts steady state @ +25°C