Peltier cooler module
APH-127-10-25-S
Data sheet
Adaptive is a registered trademark of European Thermodynamics Limited.
Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com
Imax [A] 1.9
Vmax [Vdc] 15.4
Pc max [W] 17
ΔTmax [°C] 68
A[mm] 30
A1 [mm] 30
B[mm] 30
H[mm] 4.5
L[mm] 100
Wire AWG n/a
(At hot side temperature Th = 25°C / 298K,
under dry N2 ).
Pc max = Cooling power at ΔT = 0 and I =
Imax.
ΔTmax = Temperature difference at I =
Imax and Pc = 0.
Max hot side temperature Th = 80°C for
best long term performance.
Max mounting pressure: 1.5MPa.
Wires: UL-style 1569, 105oC (Unstripped).
Peltier cooler module
APH-127-10-25-S
Data sheet - At hot side temperature 25°C
Adaptive is a registered trademark of European Thermodynamics Limited.
Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com
0
2
4
6
8
10
12
14
16
18
0 20 40 60 80
Heat removed (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
Max COP
0
5
10
15
20
25
30
35
40
45
0 20 40 60 80
Waste heat (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0
2
4
6
8
10
12
14
16
18
0 20 40 60 80
Input Voltage (V)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 0.5 1 1.5 2
COP
Current (A)
Delta T = 0 C
Delta T = 10 C
Delta T = 20 C
Delta T = 30 C
Delta T = 40 C
Delta T = 50 C
Delta T = 60 C
Peltier cooler module
APH-127-10-25-S
Data sheet - At hot side temperature 50°C
Adaptive is a registered trademark of European Thermodynamics Limited.
Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com
0
5
10
15
20
25
0 20 40 60 80
Heat removed (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
Max COP
0
5
10
15
20
25
30
35
40
45
50
0 20 40 60 80
Waste heat (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0
2
4
6
8
10
12
14
16
18
20
0 20 40 60 80
Input Voltage (V)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 0.5 1 1.5 2
COP
Current (A)
Delta T = 0 C
Delta T = 10 C
Delta T = 20 C
Delta T = 30 C
Delta T = 40 C
Delta T = 50 C
Delta T = 60 C
Peltier cooler module
APH-127-10-25-S
Data sheet - At hot side temperature 75°C
Adaptive is a registered trademark of European Thermodynamics Limited.
Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com
0
5
10
15
20
25
0 20 40 60 80 100
Heat removed (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
Max COP
0
10
20
30
40
50
60
0 20 40 60 80 100
Waste heat (W)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0
5
10
15
20
25
0 20 40 60 80 100
Input Voltage (V)
Temperature difference (oC)
I = 1.80 A
I = 1.50 A
I = 1.25 A
I = 1.00 A
I = 0.75 A
I = 0.50 A
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0 0.5 1 1.5 2
COP
Current (A)
Delta T = 0 C
Delta T = 10 C
Delta T = 20 C
Delta T = 30 C
Delta T = 40 C
Delta T = 50 C
Delta T = 60 C