APH-127-10-25-S Peltier cooler module Data sheet Imax Vmax Pc max Tmax A A1 B H L Wire [A] [Vdc] [W] [C] [mm] [mm] [mm] [mm] [mm] AWG 1.9 15.4 17 68 30 30 30 4.5 100 n/a (At hot side temperature Th = 25C / 298K, under dry N2 ). Pc max = Cooling power at T = 0 and I = Imax. Tmax = Temperature difference at I = Imax and Pc = 0. Max hot side temperature Th = 80C for best long term performance. Max mounting pressure: 1.5MPa. Wires: UL-style 1569, 105oC (Unstripped). Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com APH-127-10-25-S Peltier cooler module Data sheet - At hot side temperature 25C 18 16 14 I = 1.25 A 12 I = 1.00 A 10 I = 0.75 A 8 I = 0.50 A 6 I = 1.80 A 40 I = 1.50 A Waste heat (W) Heat removed (W) 45 I = 1.80 A I = 1.50 A 35 I = 1.25 A 30 I = 1.00 A 25 I = 0.75 A 20 I = 0.50 A 15 Max COP 4 10 2 5 0 0 0 20 40 60 80 0 Temperature difference (oC) 40 60 80 Temperature difference (oC) 18 5.0 I = 1.80 A 16 I = 1.50 A 14 I = 0.75 A 8 I = 0.50 A 6 Delta T = 30 C 3.0 Delta T = 40 C 2.5 2.0 Delta T = 50 C 1.5 Delta T = 60 C 4 1.0 2 0.5 0 Delta T = 20 C 3.5 I = 1.00 A 10 Delta T = 10 C 4.0 I = 1.25 A 12 Delta T = 0 C 4.5 COP Input Voltage (V) 20 0.0 0 20 40 60 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 80 0 0.5 1 Current (A) 1.5 2 APH-127-10-25-S Peltier cooler module Data sheet - At hot side temperature 50C 50 I = 1.80 A 20 I = 1.25 A I = 1.00 A 15 I = 0.75 A I = 0.50 A 10 I = 1.80 A 45 I = 1.50 A Waste heat (W) Heat removed (W) 25 Max COP I = 1.50 A 40 I = 1.25 A 35 I = 1.00 A 30 I = 0.75 A 25 I = 0.50 A 20 15 5 10 5 0 0 0 20 40 60 80 0 Temperature difference (oC) 40 60 80 Temperature difference (oC) 20 5.0 I = 1.80 A 18 I = 1.50 A 16 I = 0.75 A 10 I = 0.50 A Delta T = 20 C 3.5 I = 1.00 A 12 Delta T = 10 C 4.0 I = 1.25 A 14 Delta T = 0 C 4.5 Delta T = 30 C 3.0 COP Input Voltage (V) 20 Delta T = 40 C 2.5 2.0 Delta T = 50 C 6 1.5 Delta T = 60 C 4 1.0 2 0.5 8 0 0.0 0 20 40 60 80 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 0 0.5 1 Current (A) 1.5 2 APH-127-10-25-S Peltier cooler module Data sheet - At hot side temperature 75C 60 I = 1.80 A I = 1.50 A 20 I = 1.25 A I = 1.00 A 15 I = 0.75 A I = 0.50 A 10 I = 1.80 A I = 1.50 A 50 Waste heat (W) Heat removed (W) 25 I = 1.25 A 40 I = 1.00 A I = 0.75 A 30 I = 0.50 A 20 Max COP 5 10 0 0 0 20 40 60 80 100 0 Temperature difference (oC) 40 60 80 100 Temperature difference (oC) 25 6.0 I = 1.80 A I = 1.50 A 20 Delta T = 0 C Delta T = 10 C 5.0 I = 1.25 A Delta T = 20 C 4.0 I = 1.00 A 15 I = 0.75 A I = 0.50 A 10 COP Input Voltage (V) 20 Delta T = 30 C Delta T = 40 C 3.0 Delta T = 50 C 2.0 5 Delta T = 60 C 1.0 0 0.0 0 20 40 60 80 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 100 0 0.5 1 Current (A) 1.5 2