1
www.clare.com
DS-LCB120-R6
LCB120 is a 250V, 170mA, 201-Form-B relay. It fea-
tures enhanced peak load current capability and lower
on-resistance.
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Small 6 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750VRMS Input/Output Isolation
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Current Limiting, Surface Mount and Tape & Reel
V ersions A vailable
Applications
Features
Description
Ordering Information
Part # Description
LCB120 6 Pin DIP (50/Tube)
LCB120S 6 Pin Surface Mount (50/Tube)
LCB120STR 6 Pin Surface Mount (1000/Reel)
Pin Configuration
LCB120
Single Pole OptoMOS®Relay
LCB120 Units
Load Voltage 250 V
Load Current 170 mA
Max RON 20
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
Approvals
Switching Characteristics of
Normally Closed (Form B) Devices
CONTROL
10ms
10%
90% 90%
+
+
TON
TOFF
+
LCB120 Pinout
1
3
2
4
5
6
+ Control
– Control
Do Not Use
Load
Do Not Use
Load
AC/DC Configuration
1
3
2
4
5
6
+ Control
Control
Do Not Use
+ Load
Load
DC Only Configuration
LCB120 Pinout
www.clare.com
LCB120
Rev. 6
Absolute Maximum Ratings (@ 25˚ C)
2
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - VRMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Surface Mount Package - - +220 °C
(10 Seconds Max.)
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C
Electrical Characteristics
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - VL- - 250 V
Load Current (Continuous)
AC/DC Configuration - IL- - 170 mA
DC Configuration - IL- - 300 mA
Peak Load Current - IL- - 400 mA
On-Resistance
AC/DC Configuration IL=170mA RON -16 20
DC Configuration IL=300mA RON -5 6
Off-State Leakage Current VL=250V ILEAK -- 1µA
Switching Speeds
Turn-On IF=5mA, VL=10V TON -- 5ms
Turn-Off IF=5mA, VL=10V TOFF -- 5ms
Output Capacitance 50V; f=1MHz COUT -50 - pF
Capacitance
Input to Output - - - 3 - pF
Input Characteristics @ 25°C
Input Control Current IL=170mA IF5- 50mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Voltage - VR-- 5V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O -3 -pF
Input to Output Isolation - VI/O 3750 - - VRMS
LCB120
www.clare.com
Rev. 6 3
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LCB120
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
30
25
20
15
10
5
01.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
Device Count (N)
LCB120
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
35
30
25
20
15
10
5
010.4 10.8 11.2 12.011.6 12.4
On-Resistance ()
Device Count (N)
LCB120
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0291.25 293.75 296.25 298.75 301.25 303.75
Blocking Voltage (V)
Device Count (N)
LCB120
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
0.63 0.81 1.17 1.530.99 1.35
LED Current (mA)
Device Count (N)
30
25
20
15
10
5
0
LCB120
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
35
25
20
15
10
5
00.63 0.99 1.350.45 0.81 1.17
LED Current (mA)
Device Count (N)
LCB120
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
0.42 0.66 0.900.54 0.78
Turn-On (ms)
Device Count (N)
35
30
25
20
15
10
5
00.30
LCB120
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
0.875 1.375 1.8750.625 1.125 1.625
Turn-Off (ms)
Device Count (N)
35
30
25
20
15
10
5
0
LCB120
Typical Load Current vs. Temperature
Temperature (°C)
Load Current (mA)
250
200
150
100
50
0-40 -20 0 20 40 60 80 120100
5mA
LCB120
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
Temperature (°C)
Leakage (µA)
-40
0.030
0.025
0.020
0.015
0.010
0.005
0-20 0 20 40 60 80 100
LCB120
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
Temperature (°C)
Turn-On (ms)
-40
0.12
0.10
0.08
0.06
0.04
0.02
0-20 0 20 40 60 80 100
5mA
LCB120
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
Temperature (°C)
Turn-Off (ms)
-40
2.500
2.000
1.500
1.000
0.500
0-20 0 20 40 60 80 100
5mA
10mA
20mA
www.clare.com
4
LCB120
Rev. 6
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LCB120
Typical LED Forward Voltage Drop
vs. Temperature
Temperature (°C)
LED Forward Voltage Drop (V)
1.8
1.6
1.4
1.2
1.0
0.8-40 -20 0 20 40 60 80 120100
50mA
30mA
20mA
10mA
5mA
LCB120
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
LED Forward Current (mA)
Turn-On (ms)
05 1015202530354045
0.634
0.632
0.630
0.628
0.626
0.624
0.622 50
LCB120
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
Forward Current (mA)
Turn-Off (ms)
05 1015202530354045
1.2
1.0
.8
.6
.4
.2
050
LCB120
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
Temperature (°C)
On-Resistance ()
-40
60.000
50.000
40.000
30.000
20.000
10.000
0-20 0 20 40 60 80 100
LCB120
Typical IF for Switch Operation
vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
Temperature (°C)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0-20 0 20 40 60 80 100
LCB120
Typical IF for Switch Dropout
vs. Temperature
(Load Current = 170mADC)
Temperature (°C)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0-20 0 20 40 60 80 100
LCB120
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C)
IF = 5mADC
Load Voltage (V)
Load Current (mA)
200
150
100
50
0
-50
-100
-150
-200-2.0 -1.5 -1.0 -0.5 0.5 1.0 1.5
02.0
LCB120
Energy Rating Curve
Time
Load Current (A)
1.2
1.0
0.8
0.6
0.4
0.2
010µs 1ms 100ms 10s100µs 10ms 1s 100s
LCB120
www.clare.com 5
Rev. 6
MECHANICAL DIMENSIONS
Dimensions
mm
(inches)
PC Board Pattern
(Top View)
6.350 ± .127
(.250 ± .005)
2.540 ± .127
(.100 ± .005)
7.620 ± .127
(.300 ± .005)
5.080 ± .127
(.200 ± .005)
6-.800 DIA.
(6-.031 DIA.)
6.350 ± .127
(.250 ± .005)
8.382 ± .635
(.330 ± .025)
2.540 ± .127
(.100 ± .005)
9.144
(.360)
.457 ± .076
(.018 ± .003)
6 Pin DIP Through Hole (Standard)
7.239 TYP.
(.285)
3.302
(.130)
7.620 ± .254
(.300 ± .010)
9.144 ± .508
(.360 ± .020)
Tape and Reel Packaging for 6 Pin Surface Mount Package
7.493 ± .102
(.295 ± .004)
12.090
(.476)
330.2 DIA.
(13.00) 1.753 ± .102
(.069 ± .004)
3.987 ± .102
(.157 ± .004)
1.498 ± .102
(.059 ± .004)
6.731 MAX.
(.265) .406 MAX.
(.016)
4.877
(.192)
Top Cover
Tape
2.007 ± .102
(.079 ± .004)
11.989 ± .102
(.472 ± .004)
User Direction of Feed
.050R TYP.
16.002 ± .305
(.630 ± .012)
10.100
(.398)
Embossment
Embossed Carrier
Top Cover
Tape Thickness
.102 MAX.
(.004)
10.100 ± .102
(.398 ± .004) 1.549 ± .102
(.061 ± .004)
16
CLARE LOCATIONS
Clare Headquarters
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
Clare Micronix Division
145 Columbia
Aliso Viejo, CA 92656-1490
Tel: 1-949-831-4622
Fax: 1-949-831-4628
SALES OFFICES
AMERICAS
Americas Headquarters
Clare
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
Eastern Region
Clare
P.O. Box 856
Mahwah, NJ 07430
Tel: 1-201-236-0101
Fax: 1-201-236-8685
Toll Free: 1-800-27-CLARE
Central Region
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Western Region
Clare
1852 West 11th Street, #348
Tracy, CA 95376
Tel: 1-209-832-4367
Fax: 1-209-832-4732
Toll Free: 1-800-27-CLARE
Canada
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
EUROPE
European Headquarters
CP Clare nv
Bampslaan 17
B-3500 Hasselt (Belgium)
Tel: 32-11-300868
Fax: 32-11-300890
France
Clare France Sales
Lead Rep
99 route de Versailles
91160 Champlan
France
Tel: 33 1 69 79 93 50
Fax: 33 1 69 79 93 59
Germany
Clare Germany Sales
ActiveComp Electronic GmbH
Mitterstrasse 12
85077 Manching
Germany
Tel: 49 8459 3214 10
Fax: 49 8459 3214 29
Italy
C.L.A.R.E.s.a.s.
Via C. Colombo 10/A
I-20066 Melzo (Milano)
Tel: 39-02-95737160
Fax: 39-02-95738829
Sweden
Clare Sales
Comptronic AB
Box 167
S-16329 Spånga
Tel: 46-862-10370
Fax: 46-862-10371
United Kingdom
Clare UK Sales
Marco Polo House
Cook Way
Bindon Road
Taunton
UK-Somerset TA2 6BG
Tel: 44-1-823 352541
Fax: 44-1-823 352797
ASIA PACIFIC
Asian Headquarters
Clare
Room N1016, Chia-Hsin,
Bldg II, 10F, No. 96, Sec. 2
Chung Shan North Road
Taipei, Taiwan R.O.C.
Tel: 886-2-2523-6368
Fax: 886-2-2523-6369
http://www.clare.com
Worldwide Sales Offices
Specification: DS-LCB120-R6
©Copyright 2000, Clare, Inc.
OptoMOS®is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
2/6/01
Clare cannot assume responsibility for use of any circuitry other
than circuitry entirely embodied in this Clare product. No circuit
patent licenses nor indemnity are expressed or implied. Clare
reserves the right to change the specification and circuitry, with-
out notice at any time. The products described in this document
are not intended for use in medical implantation or other direct life
support applications where malfunction may result in direct phys-
ical harm, injury or death to a person.