Current
2.0 A
Voltage
50 V to 1000 V
MECHANICAL DATA
ROUND
 High case dielectric strength
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for SMPS,
lighting ballaster, adapter, battery charger, home appliances, office
equipment, and telecommunication applications..
FEATURES
High forward surge current capability
Ideal for printed circuit boards
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Typical IR less than 0.1µA
Maximun Ratings and Electrical Characteristics at 25°C
2.0 Amp. Glass Passivated Bridge Rectifier
Solder dip 260ºC, 40s
V
F
Max. forward voltage drop per
element at IF = 2.0 A
I
R
Max. reverse current per element at VRRM
1.10 V
5 µA
Electrical Characteristics at Tamb = 25 °C
2W005F....2W10F
Peak recurrent reverse voltage (V)
Maximum RMS voltage (V)
Forward current at Tamb = 25°C
V
RRM
V
RMS
I
F (AV)
T
j
T
stg
Operating temperature range
Storage temperature range  55 to + 150 °C
I
FSM
10 ms. peak forward surge current
(Jedec Method)
2.0 A
60 A
 55 to + 125 °C
Marking code
2W01F
200
140
1000
700
10 A
I
2
tI
2
t value for fusing (t = 10 ms)
15 A2sec
Recurrent peak forward current
I
FRM
2W005F
50
35
400
280
600
420
R Load
C Load
2W04F2W02F 2W08F2W06F 2W10F
800
560
100
70
2W01F2W005F 2W04F2W02F 2W08F2W06F 2W10F
Maximum DC blocking voltage (V)
V
DC
200 100050 400 600 800100
1.8 A
-
+~
~
www.fagorelectronica.com
Document Name: 2wf Version: Mar-12
Page Number: 1/4

Case: ROUND

Polarity: As marked on body.

Terminals:
Silver plated leads, solderable per J-STD-002
and JESD22-B102.
Consumer grade.
Epoxy meets UL 94V-0 flammability rating.
Package Outline Dimensions
:
(mm)
2W005F....2W10F
2.0 Amp. Glass Passivated Bridge Rectifier
Ordering information
ROUND
BU BULK 1,000 1.12
2W06F
www.fagorelectronica.com
Document Name: 2wf Version: Mar-12
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
8.5±0.5
ø0.8±0.05
9.5±0.5
5±0.5
5±0.5
4.1±0.5
30±1
Long leads
Test sorting code
Marking code
Marking code
C Serie W Serie
Week code
Year code
Week code
Year code
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
2.0 Amp. Glass Passivated Bridge Rectifier
2W005F....2W10F
Figure 1. Derating Curve Output Rectified Current
025 50 75 100 125 150
0
0.4
0.8
1.2
1.6
2.0
2.4
5.0
10
20
=
I
(pk)
I
(AV)
60 Hz
Resistive or
Inductive Load
Capacitive Load
(per Leg)
Ambient Temperature (°C)
Average Forward Output Current (A)
Copper Pads
0.22 x 0.22"
(5.5 x 5.5 mm)
P. C . B.
0.375"
(9.5 mm)
Figure 2. Maximum Non-Repetitive Peak Forward Surge
Current Per Diode
0
10
20
40
50
60
30
100
10
1
TA = 25 °C
Single Sine-Wave
Number of Cycles at 60 Hz
Peak Forward Surge Current (A)
1.0 Cycle
Figure 3. Typical Forward Characteristics Per Diode
Figure 4. Typical Reverse Leakage Characteristics Per Diode
0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.01
0.1
1
10
100
TJ = 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
020 40 60 80 100
0.01
0.1
1
10
100
Percent of Rated Peak Reverse Voltage (%)
Instantaneous Reverse Current (µA)
T
J
= 100 °C
T
J
= 125 °C
T
J
= 25 °C
Figure 5. Typical Junction Capacitance Per Diode
Figure 6. Typical Transient Thermal Impedance
100
0.1 110
1
10
100
Reverse Voltage (V)
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
Junction Capacitance (pF)
100
0.01 0.1 110 100
0.1
1
10
t - Heating Time (s)
Transient Thermal Impedance (°C/W)
www.fagorelectronica.com
Document Name: 2wf Version: Mar-12
Page Number: 3/4
Disclaimer
2.0 Amp. Glass Passivated Bridge Rectifier
2W005F....2W10F
www.fagorelectronica.com
Document Name: 5wf Version: Mar-12
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.