2W005F....2W10F 2.0 Amp. Glass Passivated Bridge Rectifier Current 2.0 A Voltage 50 V to 1000 V ROUND FEATURES High case dielectric strength High forward surge current capability Ideal for printed circuit boards Solder dip 260C, 40s Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC Typical IR less than 0.1A MECHANICAL DATA Case: ROUND Epoxy meets UL 94V-0 flammability rating. ~ + - ~ Polarity: As marked on body. Terminals: Silver plated leads, solderable per J-STD-002 and JESD22-B102. Consumer grade. TYPICAL APPLICATIONS Used in ac-to-dc bridge full wave rectification for SMPS, lighting ballaster, adapter, battery charger, home appliances, office equipment, and telecommunication applications.. Maximun Ratings and Electrical Characteristics at 25C 2W005F 2W01F 2W02F 2W04F 2W06F 2W08F 2W10F Marking code 2W005F 2W01F 2W02F 2W04F 2W06F 2W08F 2W10F VRRM Peak recurrent reverse voltage (V) 50 100 200 400 600 800 1000 VRMS Maximum RMS voltage (V) 35 70 140 280 420 560 700 VDC Maximum DC blocking voltage (V) 50 100 200 400 600 800 1000 IF (AV) Forward current at Tamb = 25C IFRM Recurrent peak forward current IFSM 10 ms. peak forward surge current I2t I2t value for fusing (t = 10 ms) 15 A2sec Tj Operating temperature range 55 to + 125 C Tstg Storage temperature range 55 to + 150 C R Load C Load (Jedec Method) 2.0 A 1.8 A 10 A 60 A Electrical Characteristics at Tamb = 25 C VF Max. forward voltage drop per element at IF = 2.0 A IR Max. reverse current per element at VRRM www.fagorelectronica.com Document Name: 2wf 1.10 V 5 A Version: Mar-12 Page Number: 1/4 2W005F....2W10F 2.0 Amp. Glass Passivated Bridge Rectifier Ordering information PREFERRED P/N PACKAGE CODE DELIVERY MODE BU 2W06F BULK BASE QUANTITY UNIT WEIGHT (g) 1,000 1.12 Package Outline Dimensions: (mm) ROUND 8.50.5 9.50.5 50.5 Long leads 50.5 W Serie 4.10.5 C Serie Marking code Test sorting code Marking code Year code Week code 301 Year code Week code o0.80.05 www.fagorelectronica.com Document Name: 2wf Version: Mar-12 Page Number: 2/4 2W005F....2W10F 2.0 Amp. Glass Passivated Bridge Rectifier Ratings and Characteristics (Ta 25 C unless otherwise noted) 60 Hz Resistive or Inductive Load 2.0 1.6 60 Peak Forward Surge Current (A) Average Forward Output Current (A) 2.4 P.C.B. 0.375" (9.5 mm) Copper Pads 0.22 x 0.22" (5.5 x 5.5 mm) 1.2 0.8 Capacitive Load I(pk) 5.0 = 10 I(AV) (per Leg) 20 0.4 0 0 25 50 75 100 125 40 30 20 10 1.0 Cycle 0 150 100 Number of Cycles at 60 Hz Figure 1. Derating Curve Output Rectified Current Figure 2. Maximum Non-Repetitive Peak Forward Surge Current Per Diode 100 TJ = 25 C Pulse Width = 300 s 1 % Duty Cycle Junction Capacitance (pF) Instantaneous Forward Current (A) 10 1 Ambient Temperature (C) 100 10 1 0.1 0.01 0.4 0.6 0.8 1.2 1.0 1.4 TJ = 25 C f = 1.0 MHz Vsig = 50 mVp-p 10 1 0.1 1.6 1 10 100 Instantaneous Forward Voltage (V) Reverse Voltage (V) Figure 3. Typical Forward Characteristics Per Diode Figure 5. Typical Junction Capacitance Per Diode 100 Transient Thermal Impedance (C/W) 100 Instantaneous Reverse Current (A) TA = 25 C Single Sine-Wave 50 TJ = 125 C 10 TJ = 100 C 1 0.1 TJ = 25 C 0.01 0 20 40 60 80 100 10 1 0.1 0.01 0.1 1 10 100 Percent of Rated Peak Reverse Voltage (%) t - Heating Time (s) Figure 4. Typical Reverse Leakage Characteristics Per Diode Figure 6. Typical Transient Thermal Impedance www.fagorelectronica.com Document Name: 2wf Version: Mar-12 Page Number: 3/4 2W005F....2W10F 2.0 Amp. Glass Passivated Bridge Rectifier Disclaimer All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. Fagor Electronica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge of typical requirements that are often placed on Fagor products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed therein. Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Fagor product could result in personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their respective owners. www.fagorelectronica.com Document Name: 5wf Version: Mar-12 Page Number: 4/4