LPT60-M Series Data Sheet
Ordering Information
Model Number Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air Peak Load1Regulation2Ripple
P/P (PARD)3
LPT62-M
+5 V
+12 V
-12 V
0.7 A
0.3 A
0 A
7 A
3 A
0.7 A
8 A
3.5 A
1 A
10 A
6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
120 mV
LPT63-M
+5 V
+15 V
-15 V
0.7 A
0.3 A
0 A
7 A
2.8 A
0.7 A
8 A
3.3 A
1 A
10 A
4 A
1.5 A
±2%
±5%
±5%
50 mV
150 mV
150 mV
Environmental Specications
Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C startup
Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to
500 Hz, operational
Storage temperature -40 °C to 85 °C
Temperature coefcient ±.04% per °C
MTBF demonstrated >550,000 hours at full load and 25 °C ambient conditions
Power Derating Curve
Output
Power
(Watts)
0°C
20W
40W
60W
80W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
0W
Natural
Convection
Cooling
40W
30W
30 CFM Forced Air Cooling
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
5.
This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as
a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System
Integrators, including through Distribution Channels. It is not intended for sale to End Users.